Skip to content
Milwaukee MA9062 1382 ppm TDS Conductivity Solution Bottle Milwaukee Instruments
Milwaukee MA9062 1382 ppm TDS Conductivity Solution Bottle Milwaukee Instruments

Milwaukee MA9062 1382 ppm TDS Conductivity Solution Bottle

$16.68

    SKU: MA9062

    UPC: 810666009688

    MPN: MA9062

    Size: 230 mL

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Ensure accurate conductivity measurements with the Milwaukee MA9062 1382 ppm TDS Conductivity Solution. This laboratory-grade solution is specifically designed to recalibrate your conductivity meter or tester, maintaining precision in your readings. By using a standard prepared against a NIST traceable potassium chloride solution, this product guarantees reliability and compliance with industry standards.

Over time, residue buildup and aging can affect the performance of conductivity probes. The Milwaukee MA9062 solution helps mitigate these effects by providing a reliable recalibration standard. Make sure to refer to your meter's manual to select the correct calibration standard to use with this solution.

Temperature can significantly influence conductivity readings. To aid in achieving optimal accuracy, each bottle of the MA9062 includes a temperature chart that displays the actual µS/cm value at varying temperatures. This necessary information enables you to make the appropriate adjustments during your measurements.

The Milwaukee MA9062 is packaged in a secure, tamper-proof bottle which is air-tight to maintain the integrity of the solution. Furthermore, each 230 mL bottle is clearly labeled with the lot number and expiration date, ensuring quality with a five-year shelf life.

  • Fundamental for precise conductivity measurement and essential for laboratory applications.
  • Factory calibrated using NIST 2202 Standard Reference Material to ensure compliance with ISO 3696/BS3978 standards.
  • Temperature chart printed on each bottle for easy reference.
  • Clear labeling with lot number and expiration date for quality assurance.
  • Sealed with an air-tight cap to prevent contamination.

Choose the Milwaukee MA9062 1382 ppm TDS Conductivity Solution for all your calibration needs. Benefit from accuracy, reliability, and a comprehensive understanding of your conductivity levels.

    Specification Detail
    Description: 1382 ppm TDS conductivity calibration solution
    Package: Bottle - size 230 mL
    Quantity: 1

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat