Skip to content
Hanna HI83314 Wastewater Multiparameter Photometer with COD & pH Meter Multiparameter Photometer Hanna Instruments
Hanna HI83314 Wastewater Multiparameter Photometer with COD & pH Meter Multiparameter Photometer Hanna Instruments
Hanna HI83314 Wastewater Multiparameter Photometer with COD & pH Meter Multiparameter Photometer Hanna Instruments
Hanna HI83314 Wastewater Multiparameter Photometer with COD & pH Meter Multiparameter Photometer Hanna Instruments

Hanna HI83314 Wastewater Multiparameter Photometer with COD & pH Meter

$1,659.99

    The Hanna HI83314 is a compact, lab-grade photometer designed for wastewater professionals who need precision across multiple parameters. With 20 methods covering COD, ammonia, Total Nitrogen, and Phosphorus, it delivers reliable results using an advanced optical system that minimizes error. Its dual functionality as a digital pH meter saves bench space while streamlining lab workflows.

    • Measures COD, ammonia, nitrogen, phosphorus, and more with high accuracy

    • Combines photometric and pH testing in one compact benchtop unit

    • Ideal for wastewater labs, nutrient monitoring, and custom absorbance curve development

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Key On-Screen Features

Method Selection

Method Selection

Quickly access 20 measurement methods and four absorbance modes using the dedicated METHOD button.

Data Logging

Advanced Data Logging

Store up to 1000 readings with user and sample IDs for comprehensive tracking and recall.

pH Measurement Mode

Professional pH Measurement

Use the photometer as a professional pH meter with automatic temperature compensation, two-point calibration, and GLP tools.


Digestion Parameters Features

Cuvette Adapter

Cuvette Adapter

Supplied 16 mm adapter accepts digestion vials for COD, nitrogen, and phosphorus workflows.

Digestion Vials

Digestion Vial Methods

Compatible with COD (EPA, ISO, mercury-free), nitrogen, and phosphorus reagents packaged in 16 mm vials. Reagents sold separately.

COD Reactor

COD Reactor

The HI839800 reactor heats digestion vials to setpoints for required durations—an essential accessory for complete wastewater monitoring.


Advanced Optical System

Innovative Design

Dual-detector stability: A beam splitter directs light to both the absorbance and reference detectors, compensating for drift and ensuring consistent performance.

High Efficiency LED Source

Bright, cool, efficient: LEDs provide high luminous output with low heat, delivering excellent performance across visible wavelengths.

Narrow Band Interference Filters

Accurate and efficient: ±1 nm wavelength accuracy and up to 95% light transmission yield stable, precise readings.

Reference Detector

Reliable consistency: Monitors light output to stabilize blank and sample measurements, even with temperature or power fluctuations.

Large Cuvette Size

25 mm path length: Larger cuvette size improves sensitivity, particularly in low absorbance samples.

Focusing Lens

Maximized light yield: Lens gathers and directs light to the detector, minimizing cuvette imperfections and eliminating indexing.

    Specification Detail
    SKU HI83314-01
    Wavelength Accuracy ±1 nm
    Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
    Spectral Bandwidth 8 nm
    Input Channels 1 pH electrode input and 5 photometer wavelengths
    pH Electrode Digital pH electrode (not included)
    Logging Type Log on demand with user name and sample ID optional input
    Logging Memory 1000 readings
    Connectivity USB-A host for flash drive, micro-USB-B for power and computer connectivity
    GLP Calibration data for connected pH electrode
    Display 128 x 64 pixel LCD with backlight
    Battery Type / Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
    Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
    Environment 0 to 50.0 °C (32 to 122.0 °F), 0 to 95% RH, non-condensing
    Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)
    Weight 1.0 kg (2.2 lbs.)
    Photometer Light Detector Silicon photodetector
    Cuvette Type Round, 24.6 mm
    Number of Methods 128 max.
    Ordering Information Supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable, power adapter, and instruction manual
    Warranty 2 years
    Note *Reagents are not included

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI83314 Wastewater Photometer Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat