Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments
Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments
Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments
Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments
Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments
Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments
Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments
Apera PC400 Portable pH/Conductivity/TDS Kit (AI413) Portable Multi-Parameter Meter Apera Instruments

Apera PC400 Portable pH/Conductivity/TDS Kit (AI413)

$499.00

    Bring pH and conductivity workflows into one portable kit. Includes 201T-S and 2301T-S electrodes with the matching standards and carrying case.

    • pH: ±0.01 pH ±1 digit; EC: ±1.0% F.S. ±1 digit
    • Measurement-focused standard model; no supported USB logger
    • IP57 meter with separate 8-pin electrode connection

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PC400 / AI413

Two measurement workflows.
One portable meter.

Carry pH and conductivity capability in one case. PC400 includes separate 201T-S pH/temperature and 2301T-S conductivity/temperature electrodes, with calculated TDS and parameter-specific calibration in a portable IP57 meter.

Choose AI413 when you need both workflows but not the recording and USB features of PC400S. Connect the appropriate electrode and select the measurement rather than assuming simultaneous dual-channel testing.

Apera PC400 portable meter and standard supplied electrode
Apera PC400 · AI413 standard kit

0.01 pH

pH resolution

±0.01 pH ±1 digit

pH + EC/TDS

Two supplied probes

Use the correct method for each parameter

IP57

Meter enclosure

Portable measurement-focused kit

Apera PC400 kit and calibration supplies
Standard-kit illustration. The text checklist identifies the included parts; optional electrodes and extra standards are separate.

Know what is in the case.

The AI413 standard kit brings together the meter, its specified electrodes and the matching calibration supplies. It is not a meter-only order.

PC400 meter, 201T-S pH/temperature and 2301T-S conductivity/temperature electrodes, pH 4.00, 7.00 and 10.01 buffers and 84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards, carrying case and instructions.

Specified electrodes

201T-S pH/temperature and 2301T-S conductivity/temperature electrodes

Calibration supplies

pH 4.00, 7.00 and 10.01 buffers; 84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards; 50 mL per listed bottle

Carry and connect

Carrying case and instructions

START WITH THE SAMPLE AND THE WORKFLOW

Where PC400 fits your work.

Water and process sampling

Move between pH and conductivity checks with the appropriate supplied electrode. Keep sample preparation and calibration records clear for each parameter.

Nutrient-solution monitoring

Use pH alongside EC or calculated TDS to answer different questions about the same solution. Neither reading identifies individual nutrients or replaces the other.

Teaching laboratories

Demonstrate how glass pH sensing differs from conductivity sensing. The two probes require different standards and different storage liquids.

A complete kit starts with the correct two probes.

PC400 supplies the 201T-S pH electrode and 2301T-S conductivity cell, not two interchangeable tips. Both use the meter’s 8-pin connection. The display shows the selected measurement with temperature; the kit is not substantiated as simultaneous pH-plus-EC acquisition.

Use pH 4.00, 7.00 and 10.01 buffers for pH work and 84 µS/cm, 1413 µS/cm and 12.88 mS/cm standards for conductivity. Keep each standard clean and never substitute pH buffers for EC calibration.

Apera 201T-S pH electrode sensing tip
Use the supplied probe for suitable samples and the correct 8-pin connector.
Apera 2301T-S conductivity and temperature sensor
The conductivity sensor uses a different calibration and storage routine from the pH electrode.

Two probes deserve two care routines.

Use the 201T-S for pH and the 2301T-S for conductivity-derived measurements. Each has a built-in temperature sensor; change the connected probe and measurement rather than assuming simultaneous pH/EC capture.

Keep the 201T-S pH glass hydrated in KCl. Follow the dedicated 2301T-S instructions for distilled/DI water in its storage cap. Do not use a shared storage liquid for convenience.

PC400 or PC400S: which do I need?

Choose the data workflow and parameter set, not the suffix alone. S does not mean a different standard probe or automatically better sample compatibility.

PC400

A measurement-focused pH and EC/TDS kit. 1-3 point pH calibration. 1-4 point EC calibration. No supported measurement logger or USB function is documented for this standard model.

PC400S

Timestamped memory, manual/timed recording and USB/PC-Link. 1000 groups per US manual. Up to five pH calibration points. Salinity/resistivity modes added. The standard supplied electrode models remain the same.

A steady display is not a data logger.

Stable-reading indication and automatic HOLD help you capture a reading consistently. Record the result in your chosen workflow. The standard PC400 is not the recording/USB version of the family; choose PC400S when its documented memory and connected-data functions are required.

A repeatable routine, from setup to storage.

01

Calibrate pH with the right family

For USA buffers, start at pH 7.00 and add pH 4.00 and/or 10.01 as appropriate. Use clean buffers, wait for stability and keep pH calibration separate from conductivity standards. The standard model supports 1-3 automatic pH calibration points.

02

Calibrate the conductivity basis

Use suitable points from 84 µS/cm, 1413 µS/cm and 12.88 mS/cm. The recognized 111.8 mS/cm point is optional. Calibrate low to high and document the reference temperature, coefficient and any TDS factor.

03

Measure with the correct probe

Rinse before and after samples, avoid bubbles at the sensor and wait for stability. Keep connectors dry. The meter’s electronic range and compensation interval do not override the supplied electrode’s sample limits.

04

Store by electrode type

Keep pH glass in its KCl-based storage system, never pure water. For 2301T-S, follow its dedicated instructions for distilled/DI water in the cap. Do not rub sensing surfaces or improvise aggressive cleaning treatments.

Which 400-series meter do I need?

pH-focused · PH400 / PH400S

For a dedicated pH routine with a separate 201T-S electrode. ORP needs a separately sold compatible electrode.

EC-focused · EC400 / EC400S

For conductivity and calculated TDS. S adds salinity/resistivity readouts and data functions.

Combined · PC400 / PC400S

For both pH and EC-derived workflows with two supplied probes, used in their appropriate modes.

Need a different portable format?

A pocket tester can suit a different handling preference. Compare the measurement requirements, sensor and recording needs before switching formats; these are alternative instruments, not compatible plug-in accessories.

Alternative format: Apera EC60 pocket conductivity/TDS/salinity tester

Related workflow: Apera PC60 multi-parameter pocket tester

PC400 buyer questions

What is included in PC400 AI413?

The standard kit includes PC400, 201T-S pH/temperature electrode, 2301T-S conductivity/temperature electrode, three pH buffers, three conductivity standards, carrying case and instructions. Each listed calibration bottle is 50 mL. The power requirement is four AA batteries.

Does PC400 measure pH and conductivity simultaneously?

It supports both through the appropriate separate electrodes and measurement modes. Simultaneous dual-channel pH and EC acquisition is not established. The simultaneous display described by Apera is selected parameter plus temperature.

What are its pH and conductivity specifications?

Meter pH range is 0.00-14.00 with 0.01 resolution and ±0.01 pH ±1 digit accuracy. Conductivity extends to 200 mS/cm with ±1.0% F.S. ±1 digit accuracy. Supplied-probe suitability remains a separate requirement.

PC400 or PC400S: which fits recording work?

PC400 is measurement-focused. PC400S adds documented 1000-group timestamped memory, timed recording, USB/PC-Link and salinity/resistivity modes, along with S-series pH functions. Both standard kits supply 201T-S and 2301T-S.

How many calibration points are available?

PC400 supports automatic 1-3 point pH calibration and 1-4 point conductivity calibration. The kit supplies three standards for each parameter; the 111.8 mS/cm fourth conductivity standard is separate.

Is TDS a separate sensor measurement?

No. TDS is calculated from conductivity using the selected conversion factor. The adjustable factor is 0.40-1.00, default 0.71. Calibrate conductivity and choose a factor appropriate to the established method.

Is an ORP electrode supplied?

No. ORP requires the separately sold 301Pt-S 8-pin electrode. The pH and conductivity electrodes listed in AI413 are not an included ORP probe.

Can I store both electrodes in the same liquid?

No. The 201T-S pH glass needs KCl-based storage and must not be stored in pure water. The dedicated 2301T-S instructions specify distilled/DI water in its conductivity storage cap. Keep the two care routines distinct.

Choose the workflow. Confirm the kit.

Review the PC400 specifications and supplied parts, then return to the price and ordering controls. Blue Tiger Scientific can help you compare the meter, probe and recording requirements for your application.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Model / catalog numberPC400 / AI413
    Supplied electrodes201T-S pH / temperature and 2301T-S conductivity / temperature electrodes
    Connector8-pin; use compatible electrode
    Meter enclosureIP57
    DisplayBacklit LCD; selected parameter and temperature
    Power requirement4 × 1.5 V AA batteries
    Measurement data memoryNo supported measurement logger documented
    RecordingDisplay HOLD is not saved measurement history
    USB / PC-LinkNot documented for standard model
    Temperature resolution0.1°C
    Temperature accuracy±0.5°C ±1 digit

    pH and mV specifications

    SpecificationDetail
    Meter pH range0.00 to 14.00 pH
    pH resolution0.01 pH
    pH accuracy±0.01 pH ±1 digit
    pH calibrationAutomatic 1-3 points
    Supplied pH buffers4.00, 7.00 and 10.01; 50 mL each
    Meter pH compensation interval0-100°C, automatic/manual; not a supplied-probe sample limit
    mV range±1000 mV
    mV resolution1 mV
    mV accuracy±0.2% F.S. ±1 digit
    Optional ORP electrode301Pt-S, 8-pin; not included

    Conductivity-derived measurements

    SpecificationDetail
    Meter conductivity range0-200 mS/cm; automatic ranges
    EC resolution by range0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm
    EC accuracy±1.0% F.S. ±1 digit
    Calculated TDS range0-100 g/L
    TDS factorAdjustable 0.40-1.00; default 0.71
    EC calibrationAutomatic 1-4 points
    Supplied EC standards84 µS/cm; 1413 µS/cm; 12.88 mS/cm; 50 mL each
    Optional fourth EC standard111.8 mS/cm; not included
    Supplied cell constantK=1.0
    Supported cell constantsK=0.1 / 1 / 10; other cells are optional
    Meter EC compensation interval0-50°C, automatic/manual
    Reference temperature15-30°C adjustable; default 25°C
    Temperature coefficient0.00-9.99%/°C; default 2.00%/°C

    Meter ranges and compensation intervals describe the electronics, not an unrestricted operating range for the supplied electrode. Match the exact probe and sample conditions to the method.

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI413
    Standard kitPC400 meter, 201T-S pH / temperature and 2301T-S conductivity / temperature electrodes, pH 4.00, 7.00 and 10.01 buffers and 84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards, carrying case and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    Apera PC400 documents

    Use the US meter manual and dedicated electrode instructions for the supplied kit. The English European brochure is supplemental regional literature. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat