Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments
Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G) pH Meter Apera Instruments

Apera GroStar GS2 Gen II Soil pH Pen Kit (AI102G)

$262.00

    Root-zone pH with the right spear and preparation tools. GroStar GS2 Gen II combines its model-specific sensor setup with a practical calibration routine and TruRead session summaries.

    • Direct prepared moist media or separate slurry method
    • GS2-E / AI802G replaceable configuration
    • Supplied dibber, brush, buffers and KCl care solution

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA GROSTAR / GS2 / GEN II / AI102G

Measure the root zone.
Not just the reservoir.

A soil/media pH pen is a sampling tool, not a drilling stake. GS2 Gen II combines a replaceable spear-glass electrode, soil-oriented PTFE junction, dibber and brush with TruRead summaries for measurements at multiple locations.

Choose GS2 for direct moist-soil or growing-media pH, or its separately prepared slurry method. Start with moisture and a pre-formed path so the sample reaches the sensor without forcing the glass.

Apera GroStar GS2 manufacturer product photograph
Manufacturer reference photograph. Use the Gen II guide for current controls; image revisions may differ.

Spear + dibber

Prepared media contact

Wet sample; gentle insertion

±0.1 pH

pH accuracy

0.1 pH resolution

TruRead

Several sampling spots

Session average, maximum and minimum

Find your GroStar modelClick or tap to compare all 6 modelsChoose a model below - click or tap here to close

Wet media first.
Dibber first. Glass second.

A soil spear is still glass. For direct testing, the manual requires wet soil and a dibber-made pathway. Take several measurements at comparable depth and angle instead of selecting the single most convenient result.

1 · Prepare

Remove the surface layer as the method directs. If dry, add suitable water and allow equilibration; the manual ideally waits 24 hours.

2 · Make a path

Use the dibber before the glass. Do not drill or force the sensor through hard particles.

3 · Measure consistently

Insert gently into the prepared path, wait for stability and repeat at comparable locations.

4 · Rinse and protect

Remove soil from the PTFE ring without rubbing the spear, then return it to KCl storage.

Apera’s field method describes about 5 cm of surface removal and a 10-15 cm pathway. Follow the full method and adapt safely to the actual bed or container; do not assume those depths fit every pot.

Direct soil and slurry are different methods.

Direct prepared moist media

Keep moisture, depth, angle and locations comparable. The dibber protects the glass and establishes the pathway.

Separate 1:5 slurry by mass

Apera’s full method mixes 20 g soil with 100 g distilled/DI water, agitates, rests overnight, remixes and settles before testing.

Do not substitute a quick 1:1 mix or compare direct and slurry values as though their preparation were identical. The Gen II manual contains the full collection, drying, mixing and settling procedure.

What arrives with AI102G?

GS2 pen with GS2-E spear probe and cap, pH 4.00 and 7.00 buffers (50 mL each), 3M KCl soaking solution (10 mL), dibber, probe-cleaning brush, four installed AAA batteries, lanyard and instructions.

The supplied-fluid list is separate from optional compatibility: pH 10.01 and any optional ORP head are separate.

Manufacturer GS2 kit or supplied-probe reference
Manufacturer contents reference. Outer packaging can vary; the text checklist identifies the supplied working items.

WHAT THIS MODEL IS BUILT TO ANSWER

Where GS2 belongs in the routine.

Direct moist soil

Make a path with the dibber before inserting the rinsed spear. Use comparable depth and angle across locations; dry, stony or hard material is not a place to force glass.

Coco coir and growing media

Choose an appropriate prepared-moist-media procedure. Keep moisture and sampling method consistent before comparing values between pots or locations.

A separate slurry workflow

Apera describes a 1:5 soil-to-water method by mass with overnight preparation. It is not the same procedure as direct insertion, and the results should not be treated as automatically interchangeable.

Choose the contact, not just the model number.

Supplied probe: GS2-E / AI802G. This is the soil/media spear with a PTFE ring junction, not the general liquid-pH bulb.

Replaceability gives the worn sensor a maintenance path; it is not an unlimited service-life guarantee. Install, condition and calibrate the correct head according to its instructions.

GroStar GS2 supplied sensing probe detail
Sensing surfaces and care instructions are probe-specific.

A SESSION SUMMARY, NOT A CLOUD LOGGER

Read several spots.
See the spread, not just one number.

In the documented Gen II TruRead workflow, a reading that has stayed stable for seven seconds is recorded for the session. Review the average, maximum and minimum after collecting your measurements. Seven seconds of stability is not the same as a fixed seven-second sampling interval.

6.2 pH

Illustrative minimum

6.3 pH

Illustrative average

6.4 pH

Illustrative maximum

The three illustrative values explain the summary; they do not prescribe a fixed sample count. The reviewed instructions do not establish retained history, timestamps or export. Use a suitable logger if those are requirements.

Calibrate the sensor you are actually using.

Complete pH 7.00 then 4.00 calibration before soil work, without switching off between the points. Calibrate in clean buffers, not in the soil or in a fertilizer solution. pH 10.01 is a separate optional point.

Rinse

Rinse between standards and samples to limit carryover. Remove excess water and bubbles, then wait for stability.

Check

Use fresh, correct standards. A calibration reminder or electrode-condition display supports the routine; it does not replace checking the method.

The right routine, shown by Apera.

Watch the manufacturer’s family tutorial alongside the current Gen II manual. The video is a practical family reference, not proof that every photographed control or accessory is identical across revisions.

Apera soil-measurement demonstration. Follow the current GS2 Gen II manual for the full method.

Keep the spear wet in KCl.

Keep the GS2 spear in 3M KCl whenever it is not in use, with the cap about one-third full and tightened. Rinse after sampling and remove soil from the white PTFE ring with the brush in water. Do not rub or wipe the blue glass spear.

A reading will not settle in dry media

Check sample moisture and preparation first. Wet the soil as the manual directs and allow equilibration instead of pressing the glass harder.

The junction is stained after soil use

Remove particles from the white PTFE ring without rubbing the spear. Slight brown coloration alone is not proof that the sensor has failed; follow cleaning and calibration checks.

Read the slope, not a “life remaining” gauge.

The pH condition figure shown after calibration describes electrode response. It is not a battery indicator, soil-health score or guaranteed percentage of service life left. Use the manual’s cleaning, conditioning and calibration checks before deciding whether to replace the probe.

Calibration markers remind you about the routine. Their disappearance after the documented reminder period is not evidence that the pen has automatically erased calibration.

When a separate field-meter format makes more sense.

If the job is a cabled-probe water-testing workflow rather than a pocket grower pen, compare the alternatives below. These are separate instruments, not plug-in accessories or direct-soil replacements for GS2.

Alternative format: Hanna HI99300 portable liquid EC/TDS meter

Related workflow: Hanna HI98195 portable water pH/ORP/EC meter

GS2 buying and ownership questions

Can I push GS2 straight into dry soil?

No. The soil must be wet, and the dibber prepares the pathway. The tip is glass, even though it is designed for soil work. Do not use the probe to drill through dry, hard or stony material.

What comes in GS2 AI102G?

The kit includes GS2 with GS2-E spear probe, pH 4.00 and 7.00 buffers, KCl soaking solution, dibber, cleaning brush, four installed AAA batteries, lanyard and instructions.

How is direct sampling prepared?

The manual removes about 5 cm of top soil, requires wet soil and uses a dibber-made path before gentle insertion. It calls for multiple consistent locations. Follow the full method and adapt depth safely to the actual bed or container.

What is Apera’s separate slurry method?

The manual combines 20 g soil with 100 g distilled/DI water, mixes, rests overnight and then remixes/settles before measurement. It is a distinct preparation method, not an unsourced quick 1:1 mix or a direct-reading equivalent.

How does TruRead help with soil sampling?

It records after a reading has stayed stable for seven seconds, then reports session average, maximum and minimum. Several comparable locations are more informative than a cherry-picked reading. No permanent logging/export feature is established.

Does GS2 measure soil EC or fertility?

The supplied GS2-E is a pH spear, not an EC or nutrient-identification sensor. A pH result alone does not quantify fertility or establish a fertilizer dose.

How should I clean and store the spear?

Rinse after tests, brush particles from the white PTFE ring without rubbing the blue glass, and keep the spear in 3M KCl when not used. Never leave it stored in tap, RO, distilled or DI water.

Is the GS2 probe replaceable?

Yes. The model-specific replacement is GS2-E, catalog AI802G. Follow the correct conditioning and calibration instructions; replaceability does not make the glass tip unbreakable.

Choose the measurement.
Confirm the supplied probe.

Review the GS2 kit and specifications, then return to the price and ordering controls. Blue Tiger Scientific can help you match the measurement, sensor and routine before ordering.

Back to price and ordering ↑
    SpecificationDetail
    Brand / familyApera Instruments / GroStar
    Model / catalog numberGS2 / AI102G
    GenerationGen II; current base-pen guide linked below
    Supplied probe configurationGS2-E / AI802G
    Probe replacementReplaceable
    As-supplied measurementpH and temperature
    pH range0.0-14.0 pH
    pH resolution0.1 pH
    pH accuracy±0.1 pH
    pH calibrationAutomatic 1-3 recognized points; follow at least 7.00 then 4.00 routine
    Supplied pH buffers7.00 and 4.00; 10.01 separate
    Optional ORPGS5-E separate; not supplied in this base kit
    Temperature measurement range0-50°C (32-122°F)
    Temperature resolution0.1°C / 0.1°F
    TruReadStable for 7 seconds then session collection; average/max/min
    Persistent log / exportNot established by reviewed Gen II instructions
    Reading HOLDManual
    Display colorsWhite measurement; green calibration; red calibration error
    ProtectionIP67; close battery cap/O-ring correctly
    Power4 AAA alkaline batteries; installed
    Idle shutoff10 minutes; see manual for disabling
    Storage routineKeep the GS2 spear in 3M KCl whenever it is not in use, with the cap about one-third full and tightened. Rinse after sampling and remove soil from the white PTFE ring with the brush in water. Do not rub or wipe the blue glass spear.

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI102G
    Working kitGS2 pen with GS2-E spear probe and cap, pH 4.00 and 7.00 buffers (50 mL each), 3M KCl soaking solution (10 mL), dibber, probe-cleaning brush, four installed AAA batteries, lanyard and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and ONE YEAR for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    GroStar GS2 documents

    Use the current Gen II guide for controls, sampling and care. The US catalog adds family/probe/kit comparison; it is not a replacement for the operator instructions. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat