$4,017.88

    Elevate your molecular biology research with the Accuris Smart-Q Fluorometers. These powerful instruments offer precise and reliable quantification of DNA, RNA, and protein samples, ensuring accurate results for critical applications such as NGS, PCR, and Western blotting. With their advanced fluorescence detection technology and compatibility with a wide range of kits, the Smart-Q Fluorometers are the ideal choice for demanding laboratory needs.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

The Accuris™ Smart-Q™ 100 and Smart-Q™ 800 Fluorometers are expertly designed to accurately quantify DNA, RNA, and protein samples. These fluorometers leverage well-established fluorescence detection methodologies, offering superior specificity and enhanced accuracy compared to traditional UV-absorbance methods. Precise results are essential for workflows such as:

  • Next Generation Sequencing
  • PCR
  • Transfection
  • Western Blotting
  • Immunoassays

The Smart-Q Fluorometers are optimized for use with Accuris' Fluorescent DNA Quantification Kits and assay tubes but are also compatible with a variety of kits from other suppliers.

Intuitive Usability

Each instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick & effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.

Accurate Quantification

The Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.

The Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.

The concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.

Options for Throughput

The Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:

The Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.

The Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.

Accuris DNA Quantification Kits

Accuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.

High Sensitivity dsDNA Assay Kit
The Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng/ul, providing detection of 0.1 to 100 ng

Broad Range dsDNA Assay Kit
The Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng/µL, providing a detection range of 4−2,000 ng.

    Feature Details
    Display 7.0-inch, color touch screen
    Dynamic Range 4 orders of magnitude
    Light Source Blue and Red LED
    Excitation Wavelengths Blue: 460 ± 20nm and Red: 625 ± 20nm
    Emission Wavelengths Green: 525 – 570nm and Red: 670 – 725nm
    Stability ≤ 1.5%
    Detector Photodiodes (300-1000nm)
    Measurement Speed ≤ 6 seconds
    Consumable Type 0.2mL assay tubes (single and 8-tube strip)
    Input Voltage 24 VDC 2A
    Dimensions (WxDxH) 16.1 x 28.7 x 7.6cm / 6.34 x 11.30 x 3.0in.
    Weight 2.0kg / 4.4lbs

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY