{"product_id":"winpact-fs-05-parallel-bioreactor","title":"Major Science Winpact FS-05 Parallel Bioreactor","description":"\u003carticle aria-label=\"Winpact FS-05 parallel bioreactor product guide\" class=\"wp-story\"\u003e\n\u003csection aria-labelledby=\"wp-title\" class=\"wp-hero\" id=\"wp-overview\"\u003e\n\u003cdiv class=\"wp-hero-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eBlue Tiger Scientific · Winpact\u003c\/p\u003e\n\u003ch1 id=\"wp-title\"\u003eWinpact FS-05 Parallel Bioreactor\u003c\/h1\u003e\n\u003cp class=\"wp-lead\"\u003ePut your next two experiments side by side.\u003c\/p\u003e\n\u003cp\u003eCompare culture conditions, explore a new feed strategy or run different vessel configurations from one controller. The FS-05 brings two independently controlled vessels together on a shared platform, with a clear touchscreen and dedicated pumping capacity for each run.\u003c\/p\u003e\n\u003cdiv class=\"wp-actions\"\u003e\n\u003cbutton class=\"wp-button\" data-wp-open=\"\" type=\"button\"\u003eRequest a Configured Quote\u003c\/button\u003e\u003ca class=\"wp-text-link\" href=\"#wp-vessels\"\u003eExplore vessel choices \u003cspan aria-hidden=\"true\"\u003e↓\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eConfigured for your process—not a fixed bundle of every vessel pictured.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"wp-hero-image\"\u003e\u003cimg alt=\"Winpact FS-05 controller with touchscreen, eight pump heads and two flowmeters\" height=\"1000\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-hero.webp?v=1792798224\" width=\"1000\"\u003e\n\u003cfigcaption\u003eThe FS-05 controller: one interface, two vessel channels.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/section\u003e\n\u003cdiv aria-label=\"FS-05 at a glance\" class=\"wp-spec-band\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e2 vessels\u003c\/strong\u003e\u003cspan\u003eper controller\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e0.5–20 L\u003c\/strong\u003e\u003cspan\u003eworking-volume family*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e8 pumps\u003c\/strong\u003e\u003cspan\u003e4 per vessel\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e10.4-inch\u003c\/strong\u003e\u003cspan\u003ecolour touchscreen\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-band-note\"\u003e*Available working volumes depend on vessel type and heating arrangement; not one adjustable 0.5–20 L vessel.\u003c\/p\u003e\n\u003csection aria-labelledby=\"wp-paired-title\" class=\"wp-section wp-split\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003cimg alt=\"Example FS-05 two-vessel arrangement\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-ai_system-v2.webp?v=1792811356\" width=\"1200\"\u003e\n\u003cfigcaption\u003eExample FS-05 two-vessel arrangement. Vessel sizes and accessories are selected for your project.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eTwo runs. One workspace.\u003c\/p\u003e\n\u003ch2 id=\"wp-paired-title\"\u003eMake comparison part of the workflow.\u003c\/h2\u003e\n\u003cp\u003eRun the same experiment in both vessels or give each a different task. Compatible sizes and vessel types can differ, helping you plan paired studies without requiring identical hardware on both sides.\u003c\/p\u003e\n\u003cp\u003eDuo heating supports two thermostat-heated runs, two dry-heated runs, or one of each. Choose the arrangement around your culture and utilities rather than assuming every vessel uses the same temperature-control method.\u003c\/p\u003e\n\u003cul class=\"wp-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia development:\u003c\/strong\u003e compare formulations under defined control settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeed optimisation:\u003c\/strong\u003e investigate substrate delivery and process responses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCulture development:\u003c\/strong\u003e select stirred, air-lift or solid-state configurations to suit the work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-parallel-title\" class=\"wp-section wp-tint\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eThe parallel concept\u003c\/p\u003e\n\u003ch2 id=\"wp-parallel-title\"\u003eShared controller. Separate experiments.\u003c\/h2\u003e\n\u003cp\u003eFour built-in pump heads per vessel can be assigned to acid, base, antifoam and substrate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csvg aria-labelledby=\"wp-diagram-title wp-diagram-desc\" class=\"wp-diagram\" role=\"img\" viewbox=\"0 0 960 250\"\u003e\u003ctitle id=\"wp-diagram-title\"\u003eFS-05 two-vessel control concept\u003c\/title\u003e\n\u003cdesc id=\"wp-diagram-desc\"\u003eOne FS-05 controller connects to vessel A and vessel B. Each vessel has four built-in pump heads assigned to its channel. Compatible vessel sizes and heating methods can differ.\u003c\/desc\u003e\u003cg fill=\"none\" stroke=\"#235c86\" stroke-width=\"3\"\u003e\u003cpath d=\"M350 105H235V65H175M610 105H725V65H785\"\u003e\u003c\/path\u003e\u003crect fill=\"white\" height=\"155\" rx=\"18\" width=\"260\" x=\"350\" y=\"42\"\u003e\u003c\/rect\u003e\u003cpath d=\"M110 40v145q0 25 35 25h40q35 0 35-25V40M740 40v145q0 25 35 25h40q35 0 35-25V40\"\u003e\u003c\/path\u003e\u003cpath d=\"M110 135h110M740 135h110\" stroke=\"#245B45\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003cg fill=\"#13314e\" font-family=\"Arial, sans-serif\" text-anchor=\"middle\"\u003e\u003ctext font-size=\"26\" font-weight=\"700\" x=\"480\" y=\"90\"\u003eFS-05\u003c\/text\u003e\u003ctext font-size=\"18\" x=\"480\" y=\"121\"\u003eOne controller\u003c\/text\u003e\u003ctext font-size=\"16\" x=\"480\" y=\"153\"\u003e10.4-inch touchscreen\u003c\/text\u003e\u003ctext font-size=\"23\" font-weight=\"700\" x=\"165\" y=\"96\"\u003eA\u003c\/text\u003e\u003ctext font-size=\"23\" font-weight=\"700\" x=\"795\" y=\"96\"\u003eB\u003c\/text\u003e\u003ctext font-size=\"17\" x=\"165\" y=\"239\"\u003e4 pump heads\u003c\/text\u003e\u003ctext font-size=\"17\" x=\"795\" y=\"239\"\u003e4 pump heads\u003c\/text\u003e\u003c\/g\u003e\u003c\/svg\u003e\n\u003cp class=\"wp-small wp-center\"\u003eConcept diagram, not a piping schematic or a performance comparison.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-vessel-title\" class=\"wp-section\" id=\"wp-vessels\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eStart with the culture\u003c\/p\u003e\n\u003ch2 id=\"wp-vessel-title\"\u003eChoose the vessel—not just the litre number.\u003c\/h2\u003e\n\u003cp\u003eWorking volume is the intended culture volume; total volume includes headspace. Two vessels labelled “5 L working” can have different total capacities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-vessel-photo-guide\"\u003e\n\u003cp class=\"wp-guide-intro\"\u003eFive vessel approaches. See the hardware, then compare how each fits your process.\u003c\/p\u003e\n\u003cdiv class=\"wp-vessel-photo-cards\"\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-A family jacketed vessel, cropped from manufacturer FS-05 system photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_jacketed-v2.webp?v=1792811351\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-A family jacketed vessel, cropped from manufacturer FS-05 system photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_jacketed-v2.webp?v=1792811351\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-A family\u003c\/p\u003e\n\u003ch3\u003eJacketed glass\u003c\/h3\u003e\n\u003cp\u003eA jacketed vessel option for thermostat-based temperature control. Select the working volume and culture requirements together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-B family vessel with heating blanket, manufacturer photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_blanket-v2.webp?v=1792811351\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-B family vessel with heating blanket, manufacturer photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_blanket-v2.webp?v=1792811351\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-B family\u003c\/p\u003e\n\u003ch3\u003eBlanket heating\u003c\/h3\u003e\n\u003cp\u003eA single-wall vessel with an external heating blanket. Available capacities depend on the selected vessel configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-C053 single-wall air-lift vessel, 5 L working volume, manufacturer catalogue photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_airlift-v2.webp?v=1792811352\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-C053 single-wall air-lift vessel, 5 L working volume, manufacturer catalogue photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_airlift-v2.webp?v=1792811352\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-C053 example\u003c\/p\u003e\n\u003ch3\u003eAir-lift mixing\u003c\/h3\u003e\n\u003cp\u003eGas circulation rather than an agitation motor. This 5 L single-wall example has no temperature control; jacketed options differ.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-D family vessel with heating base, manufacturer photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_base-v2.webp?v=1792811352\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-D family vessel with heating base, manufacturer photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_base-v2.webp?v=1792811352\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-D family\u003c\/p\u003e\n\u003ch3\u003eBase heating\u003c\/h3\u003e\n\u003cp\u003eA plain-bottom vessel and heating base. Match the selected capacity, heating method and cooling arrangement to the process.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-SA05P 5 L solid-state vessel, original manufacturer photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_solid-v2.webp?v=1792811353\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-SA05P 5 L solid-state vessel, original manufacturer photograph\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_solid-v2.webp?v=1792811353\" width=\"1200\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-SA05P · 5 L\u003c\/p\u003e\n\u003ch3\u003eSolid-state culture\u003c\/h3\u003e\n\u003cp\u003eA specialist vessel and handling assembly for solid substrates. Sensing and handling requirements differ from liquid culture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003ePhotographs show configuration examples, not a five-vessel package. Liquid colors are illustrative. Each selected vessel has its own working and total capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection aria-labelledby=\"wp-vessel-overview-heading\" class=\"wp-supplied-overview\" data-wp-addition=\"vessel-overview\"\u003e\u003ch3 id=\"wp-vessel-overview-heading\"\u003eWinpact bioreactor vessel formats, side by side\u003c\/h3\u003e\n\u003cp\u003eUse this overview to orient yourself, then match the vessel family, working volume and heating approach to your process.\u003c\/p\u003e\n\u003cfigure class=\"wp-supplied-wide\"\u003e\u003ca aria-label=\"Open larger Winpact vessel illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-overview.webp?v=1792813449\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Winpact bioreactor vessel-format overview: stirred, air-lift, heated and solid-state examples\" decoding=\"async\" height=\"848\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-overview.webp?v=1792813449\" width=\"2336\"\u003e\u003c\/a\u003e\u003cfigcaption\u003eVessel-format overview. Examples are not drawn to scale and are not a package of included vessels.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv class=\"wp-supplied-mobile\"\u003e\n\u003cfigure class=\"wp-supplied-detail\"\u003e\u003ca aria-label=\"Open larger Winpact vessel illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-liquid-detail.webp?v=1792813449\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Detail of stirred and air-lift vessel examples in the Winpact vessel overview\" decoding=\"async\" height=\"848\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-liquid-detail.webp?v=1792813449\" width=\"930\"\u003e\u003c\/a\u003e\u003cfigcaption\u003eDetail: stirred glass and air-lift vessel examples.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cfigure class=\"wp-supplied-detail\"\u003e\u003ca aria-label=\"Open larger Winpact vessel illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-heated-solid-detail.webp?v=1792813450\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Detail of heated and solid-state vessel examples in the Winpact vessel overview\" decoding=\"async\" height=\"848\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-heated-solid-detail.webp?v=1792813450\" width=\"1406\"\u003e\u003c\/a\u003e\u003cfigcaption\u003eDetail: heated and solid-state vessel examples.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cul class=\"wp-vessel-legend\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e1–2:\u003c\/strong\u003e Stirred glass vessel examples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3–4:\u003c\/strong\u003e Air-lift vessel examples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5:\u003c\/strong\u003e Heating-blanket format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6:\u003c\/strong\u003e Heating-base format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7:\u003c\/strong\u003e Solid-state format\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"wp-small\"\u003eThe positioning angles shown apply to the illustrated 5 L solid-state design. Available sizes, heating and sensing depend on the selected configuration.\u003c\/p\u003e\u003c\/section\u003e\n\u003cdiv class=\"wp-table-wrap\"\u003e\n\u003ctable data-wp-mobile-table=\"true\"\u003e\n\u003ccaption\u003eIllustrative 5 L working-volume choices\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eVessel configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWorking \/ total\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSelection consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eJacketed dish-bottom\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.8 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eThermostat-based temperature control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eSingle-wall + blanket\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.8 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eDry heating; family extends to 20 L working\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eAir-lifter\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 7 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eDraft tube and micro-sparger; no agitation motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003ePlain-bottom + heating base\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.7 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eBase-heated arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eSolid-state\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.8 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eSpecialist configuration; confirm sensing and handling needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eSingle-wall air-lifters have no temperature control; jacketed versions are available. Vessel bodies are borosilicate glass with 316L stainless-steel headplates and fittings.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-solid-visual-title\" class=\"wp-section wp-tint\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eA different cultivation format\u003c\/p\u003e\n\u003ch2 id=\"wp-solid-visual-title\"\u003eTake a closer look at solid-state fermentation.\u003c\/h2\u003e\n\u003cp\u003eThe 5 L FS-V-SA05P is a specialist alternative to the liquid-culture vessels. Its assembly supports vessel positioning and harvesting as well as mixing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-two-cards\"\u003e\n\u003cdiv class=\"wp-solid-visual\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: FS-V-SA05P 5 L solid-state vessel and handling assembly\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-ai_solid-v2.webp?v=1792811357\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-SA05P 5 L solid-state vessel and handling assembly\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-ai_solid-v2.webp?v=1792811357\" width=\"1200\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eFS-V-SA05P 5 L solid-state vessel and handling assembly.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-solid-visual\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: Manufacturer feature graphic of FS-V-SA05P solid-state tilting and harvesting positions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-solid_motion-v2.webp?v=1792811355\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Manufacturer feature graphic of FS-V-SA05P solid-state tilting and harvesting positions\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-solid_motion-v2.webp?v=1792811355\" width=\"1200\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eManufacturer feature graphic: the illustrated 5 L design supports 0–90° culture positioning and 120° harvesting. This does not describe every solid-state size.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-solid-caption\"\u003e\n\u003ch3\u003eSpecify the material and handling needs.\u003c\/h3\u003e\n\u003cp\u003eTell us the substrate characteristics, intended capacity and mixing needs. pH and DO sensing are optional in the published solid-state configuration, rather than assumed liquid-culture inclusions.\u003c\/p\u003e\n\u003cbutton class=\"wp-button\" data-wp-open=\"\" type=\"button\"\u003eDiscuss solid-state options\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-heating-title\" class=\"wp-section wp-split wp-reverse\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003cimg alt=\"FS-05 with two glass vessels, one fitted with a red heating blanket\" height=\"1000\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-mixed.webp?v=1792798227\" width=\"1000\"\u003e\n\u003cfigcaption\u003eA mixed arrangement illustrates different heating approaches on the same controller.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eMake the specification practical\u003c\/p\u003e\n\u003ch2 id=\"wp-heating-title\"\u003ePlan the complete bench setup.\u003c\/h2\u003e\n\u003cp\u003eMost listed controlled vessel configurations operate from 5°C above coolant temperature to 60°C; base-heated vessels extend to 90°C. These are configuration-specific ranges, not a universal 5–90°C claim.\u003c\/p\u003e\n\u003cp\u003eThe FS-05 requires 210–230 V, 50–60 Hz supply. Plan for dry, oil-free, filtered air at 0.5–2 bar and water at 0.4–1 bar. Supplied cooling water must be at least 15°C below the operating setpoint.\u003c\/p\u003e\n\u003cp\u003eController dimensions are 400 × 549 × 740 mm (W × L × H). Add space for both vessels, tubing, utilities and access—and check autoclave clearance with the condenser attached.\u003c\/p\u003e\n\u003cbutton class=\"wp-button wp-button-secondary\" data-wp-open=\"\" type=\"button\"\u003eCheck my bench and utilities\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-controls-title\" class=\"wp-section wp-split\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003cimg alt=\"Annotated FS-05 controller showing screen, pumps, USB connection, power switch and flowmeters\" height=\"1182\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-anatomy.webp?v=1792798228\" width=\"1000\"\u003e\n\u003cfigcaption\u003eController anatomy: A touchscreen; B pumps; C USB; D power; E flowmeters; F front panel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eControl with context\u003c\/p\u003e\n\u003ch2 id=\"wp-controls-title\"\u003eKeep routine adjustments close at hand.\u003c\/h2\u003e\n\u003cp\u003eThe touchscreen brings process settings and pump control into one interface. Built-in pumps run at 0–65 rpm in 1 rpm increments; 15-step programming supports structured process sequences.\u003c\/p\u003e\n\u003cp\u003eUSB export and Ethernet remote communication help connect bench work with review. An external PC can network up to 16 FS-05 controllers for up to 32 vessels—not 32 vessels directly connected to one controller.\u003c\/p\u003e\n\u003cp\u003eChoose advanced capabilities deliberately: EZScript, external pumps and additional analytical devices are options to discuss with your configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-pump-detail-title\" class=\"wp-section wp-split wp-detail-feature\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: FS-05 eight built-in pump heads and two flowmeters, original detail\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-pump_detail-v2.webp?v=1792811354\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-05 eight built-in pump heads and two flowmeters, original detail\" height=\"456\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-pump_detail-v2.webp?v=1792811354\" width=\"466\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eFS-05 close-up: eight pump heads, with four assigned to each vessel channel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eLook at the details\u003c\/p\u003e\n\u003ch2 id=\"wp-pump-detail-title\"\u003eDedicated feeds for each experiment.\u003c\/h2\u003e\n\u003cp\u003eThe two banks of four built-in pump heads give each vessel its own pumping capacity. Assign them to acid, base, antifoam and substrate according to the selected process.\u003c\/p\u003e\n\u003cp\u003eTell us how many separate feeds you expect to use. If your work needs additional feeds, external pumps are a configuration discussion—not something to infer from the photograph.\u003c\/p\u003e\n\u003cbutton class=\"wp-button wp-button-secondary\" data-wp-open=\"\" type=\"button\"\u003ePlan my feeds\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-software-title\" class=\"wp-section wp-software\"\u003e\n\u003ch2 id=\"wp-software-title\"\u003eSee the controls, one screen at a time.\u003c\/h2\u003e\n\u003cp\u003eExplore the shared Winpact interface with individual views instead of a compressed screenshot strip.\u003c\/p\u003e\n\u003cdiv class=\"wp-interface-cards\"\u003e\n\u003carticle class=\"wp-interface-card\"\u003e\n\u003cfigure class=\"wp-screen-photo\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact manual-control screen, original manufacturer screenshot\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_manual-v2.webp?v=1792811357\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact manual-control screen, original manufacturer screenshot\" height=\"269\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_manual-v2.webp?v=1792811357\" width=\"333\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact interface view.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eManual process control\u003c\/h3\u003e\n\u003cp\u003eA view of individual process parameters and their control settings.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-interface-card\"\u003e\n\u003cfigure class=\"wp-screen-photo\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact sequence-control screen, original manufacturer screenshot\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_sequence-v2.webp?v=1792811358\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact sequence-control screen, original manufacturer screenshot\" height=\"269\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_sequence-v2.webp?v=1792811358\" width=\"333\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact interface view.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSequence planning\u003c\/h3\u003e\n\u003cp\u003eA view of programmed steps for a structured process sequence.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-interface-card\"\u003e\n\u003cfigure class=\"wp-screen-photo\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact pump-control screen, original manufacturer screenshot\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_pumps-v2.webp?v=1792811359\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact pump-control screen, original manufacturer screenshot\" height=\"269\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_pumps-v2.webp?v=1792811359\" width=\"334\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact interface view.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePump settings\u003c\/h3\u003e\n\u003cp\u003eA view of pump controls and feed settings for the selected process.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eShared interface examples. Optional functionality, including EZScript, is selected with the configuration. Open any screen image for its full-size source view.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-remote-view-title\" class=\"wp-section wp-split\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact remote interface, manufacturer screenshot; computer not included\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-remote_screen-v2.webp?v=1792811354\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact remote interface, manufacturer screenshot; computer not included\" height=\"381\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-remote_screen-v2.webp?v=1792811354\" width=\"645\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact remote-interface view. External PC and network equipment are not included.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eConnect the bench to review\u003c\/p\u003e\n\u003ch2 id=\"wp-remote-view-title\"\u003eA closer look at remote monitoring.\u003c\/h2\u003e\n\u003cp\u003eFS-05 supports Ethernet remote communication. The published architecture allows an external PC to connect up to 16 FS-05 controllers, representing up to 32 vessel channels.\u003c\/p\u003e\n\u003cp\u003eInclude your networking and data-review needs in the enquiry so that software, interfaces and any required external equipment can be scoped together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-package-title\" class=\"wp-section wp-tint\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eA clear scope of supply\u003c\/p\u003e\n\u003ch2 id=\"wp-package-title\"\u003eSpecify what you need. Know what is optional.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-two-cards\"\u003e\n\u003cdiv class=\"wp-card\"\u003e\n\u003ch3\u003eBasic liquid-culture configuration\u003c\/h3\u003e\n\u003cp\u003eController, rotameter and built-in pumps; selected vessel assembly; pH, DO, temperature and foam\/level sensing. Stirred vessels specify a brushless motor, impellers and baffles, with condenser and sparger.\u003c\/p\u003e\n\u003cp\u003eA start-up kit lists silicone tubing, clamps, metal connector and autoclavable disc filters. Final quantities follow the agreed two-vessel bill of materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-card\"\u003e\n\u003ch3\u003eConfigure separately\u003c\/h3\u003e\n\u003cp\u003eVessel sizes and heating arrangements; water circulator\/chiller; ORP, optical density, gas mixing, oxygen enrichment, mass-flow control, off-gas analysis, lighting, external pumps and EZScript.\u003c\/p\u003e\n\u003cp\u003eBlankets or bases accompany the correspondingly named vessel configuration—not every vessel. Solid-state sensing differs from liquid-culture configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-card\" data-wp-brochure-refinement=\"process-options\" style=\"margin-top:24px\"\u003e\n\u003ch3\u003eMatch the options to the job\u003c\/h3\u003e\n\u003cul class=\"wp-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen-control needs:\u003c\/strong\u003e describe whether the process uses air, oxygen enrichment or mixed gases. External oxygen and gas mixing require the appropriate optional hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent feeds:\u003c\/strong\u003e list acid, base, antifoam and nutrient feeds separately. FS-05 provides four built-in pump heads per vessel; additional feeding lines require a configured expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional monitoring:\u003c\/strong\u003e tell us if ORP, off-gas measurements, optical density, lighting or remote monitoring are needed. These are separate selection decisions, not blanket standard inclusions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferent conditions in each vessel:\u003c\/strong\u003e specify both working volumes and any differences in temperature, mixing, gas strategy and sensing so that both channels can be quoted together.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-compare-title\" class=\"wp-section\" id=\"wp-compare\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFind your fit\u003c\/p\u003e\n\u003ch2 id=\"wp-compare-title\"\u003eFS-05, FS-06 or FS-07?\u003c\/h2\u003e\n\u003cp\u003eChoose by experimental layout, vessel range and expansion needs—not model number alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-card\" data-wp-brochure-refinement=\"model-selection\" style=\"margin:24px 0\"\u003e\n\u003ch3\u003eChoose the controller around the experiment\u003c\/h3\u003e\n\u003cul class=\"wp-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFS-05 Parallel:\u003c\/strong\u003e two independently controlled vessels from one controller. Choose it when paired runs are central to your work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFS-06 One:\u003c\/strong\u003e one vessel, three built-in pumps and a narrower controller footprint, with compatible working-volume options up to 10 L. Basic liquid-culture sensing is included in the published standard package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFS-07 Evo:\u003c\/strong\u003e one vessel with four built-in pumps, compatible working-volume options up to 20 L and a published solid-state configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMore than one FS-06 or FS-07 can be used when separate controllers are appropriate. Tell us both the total vessel count and whether you need two vessels operated from a single controller.\u003c\/p\u003e\n\u003ch3\u003eWhen FS-06 needs the EPM expansion module\u003c\/h3\u003e\n\u003cp\u003eThe FS-06 brochure identifies selected pH-Stat and DO-Stat feeding functions, expanded oxygen\/gas control, ORP, a second external pump, and pump flow\/total-volume calculation as expansion-module-dependent. The relevant devices must also be specified. Ordinary onboard programmable control is not the same as this optional expansion.\u003c\/p\u003e\n\u003cp\u003eShare the capabilities you need; the final quote will identify the controller, module and accessory combination rather than assume every illustrated accessory is compatible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-table-wrap\"\u003e\n\u003ctable data-wp-mobile-table=\"true\"\u003e\n\u003ccaption\u003eWinpact controller comparison\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFS-05 Parallel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFS-06 One\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFS-07 Evo\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eVessels per controller\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e2\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e1\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eWorking-volume family\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e0.5–20 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e0.5–10 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e0.5–20 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eTouchscreen \/ built-in pumps\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e10.4 in \/ 8\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e8 in \/ 3\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e10.4 in \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eController W × L × H, mm\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e400 × 549 × 740\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e250 × 510 × 500\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e400 × 600 × 740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eSolid-state configuration\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003eAvailable\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003eNot supported\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eMass-flow \/ off-gas analysis\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003eNot supported\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eFS-06 includes basic process sensing; some other expansions require its optional EPM module. EPM does not add a second vessel or extend it to 20 L.\u003c\/p\u003e\n\u003csection aria-labelledby=\"wp-fs06-image-heading\" class=\"wp-fs06-comparison-visual\" data-wp-addition=\"fs06-comparison\"\u003e\u003cp class=\"wp-eyebrow\"\u003eAlternative model · FS-06 One\u003c\/p\u003e\n\u003ch3 id=\"wp-fs06-image-heading\"\u003eConsidering a single-vessel Winpact bioreactor?\u003c\/h3\u003e\n\u003cp\u003eThe FS-06 One controls one vessel and has three built-in pumps. The FS-05 Parallel controls two vessels with eight built-in pumps. Use the comparison above to choose the experimental layout you need.\u003c\/p\u003e\n\u003cfigure\u003e\u003ca aria-label=\"Open full FS-06 One vessel and networking illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-fs06-overview.webp?v=1792813451\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cpicture\u003e\u003csource media=\"(max-width:760px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-fs06-controller-detail.webp?v=1792813451\"\u003e\u003cimg alt=\"Winpact FS-06 One single-vessel bioreactor system illustration\" decoding=\"async\" height=\"1104\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-fs06-overview.webp?v=1792813451\" width=\"1792\"\u003e\u003c\/picture\u003e\u003c\/a\u003e\u003cfigcaption\u003eFS-06 One illustrated with vessel-format and networking examples. Vessel sizes and options vary by controller.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cp class=\"wp-small wp-fs06-mobile-note\"\u003eController detail shown for phone readability. Open the image to view the full vessel and networking illustration.\u003c\/p\u003e\u003c\/section\u003e\n\u003cfigure class=\"wp-media wp-size\"\u003e\u003cimg alt=\"Front-profile comparison of FS-05, FS-06 and FS-07 controller widths and heights\" height=\"750\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-size.webp?v=1792798230\" width=\"1000\"\u003e\n\u003cfigcaption\u003eFront profiles only; use the dimension table for controller depth and allow additional installed-system space.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-actions\"\u003e\n\u003cbutton class=\"wp-button wp-button-secondary\" data-model=\"FS-06\" data-wp-open=\"\" type=\"button\"\u003eAsk about FS-06\u003c\/button\u003e\u003cbutton class=\"wp-button wp-button-secondary\" data-model=\"FS-07\" data-wp-open=\"\" type=\"button\"\u003eAsk about FS-07\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-resources-title\" class=\"wp-section wp-tint\" id=\"wp-resources\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eLook closer\u003c\/p\u003e\n\u003ch2 id=\"wp-resources-title\"\u003eWatch the system. Review the details.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-video\"\u003e\u003ciframe loading=\"lazy\" src=\"https:\/\/www.youtube.com\/embed\/SdttlanNEV0\" title=\"Winpact Parallel Fermentation System — official Major Science video\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eOfficial Major Science overview of the Winpact Parallel Fermentation System.\u003c\/p\u003e\n\u003cdiv class=\"wp-two-cards\"\u003e\n\u003ca class=\"wp-resource\" href=\"https:\/\/www.majorsci.com\/rwd1661\/store\/F1\/FS-05.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan class=\"wp-eyebrow\"\u003ePDF · FS-05\u003c\/span\u003e\n\u003ch3\u003eFS-05 product brochure \u003cspan aria-hidden=\"true\"\u003e↗\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eReview controller specifications and vessel choices.\u003c\/p\u003e\n\u003c\/a\u003e\u003ca class=\"wp-resource\" href=\"https:\/\/www.majorsci.com\/rwd1661\/store\/F1\/Brochure-004-Fermentor.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan class=\"wp-eyebrow\"\u003ePDF · Brochure 004\u003c\/span\u003e\n\u003ch3\u003eBioreactor \u0026amp; fermentor guide \u003cspan aria-hidden=\"true\"\u003e↗\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eCompare the wider Winpact controller family.\u003c\/p\u003e\n\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-faq-title\" class=\"wp-section\" id=\"wp-faq\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eBefore you configure\u003c\/p\u003e\n\u003ch2 id=\"wp-faq-title\"\u003eQuestions worth asking.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-faq-grid\"\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eCan both vessels run different experiments?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Each vessel can run the same or a different experiment, using compatible sizes, types and heating arrangements. Specify both channels together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eDoes 5 L mean total vessel capacity?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. Here, 5 L means working volume. Total capacity varies: 6.7 L for a plain-bottom base-heated vessel, 6.8 L for dish-bottom examples and 7 L for an air-lifter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWhich setup suits gentle mixing?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eDiscuss air-lift vessels or pitched-blade impellers for your culture. Air-lifters use gas circulation without an agitation motor; stirred-vessel speed ranges depend on size and impeller choice.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWhat gets sterilised in the autoclave?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe selected vessels are autoclavable, not the controller. This is not an in-situ SIP system. The PT100 temperature probe is non-autoclavable; confirm the preparation procedure and chamber clearance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWill I need a separate chiller?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThat depends on your setpoint and available cooling water. Check the required coolant temperature, flow arrangement and heat load; an external circulator\/chiller is a separately configured option.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eAre all software features included?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eOnboard control, USB export and Ethernet communication are documented. Advanced EZScript is optional. Confirm remote software and external PC requirements in the quotation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eAre these PDFs operating manuals?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo: they are product brochures. Manufacturer instruction and service manuals are accessed through its Member Download Center; request the appropriate documentation for your configured system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWhat should I send for a useful quotation?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eShare organism or culture type, working volume for each vessel, agitation and temperature needs, gas strategy, sensing, available utilities and autoclave dimensions. Include any feed or analysis options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-next-title\" class=\"wp-closing\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eYour next experiment starts with the right configuration\u003c\/p\u003e\n\u003ch2 id=\"wp-next-title\"\u003eTell us what you want to compare.\u003c\/h2\u003e\n\u003cp\u003eBlue Tiger Scientific can help frame a two-vessel specification around your culture, bench and process goals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbutton class=\"wp-button\" data-wp-open=\"\" type=\"button\"\u003eRequest configuration advice\u003c\/button\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Major Science","offers":[{"title":"2 × 0.5 L jacketed vessel kits · 220 V","offer_id":53155427320106,"sku":"BTS-FS05-2XAS5P-220","price":58512.0,"currency_code":"USD","in_stock":true},{"title":"2 × 1 L jacketed vessel kits · 220 V","offer_id":53217828864298,"sku":"BTS-FS05-2XA01P-220","price":58544.0,"currency_code":"USD","in_stock":true},{"title":"2 × 3 L jacketed vessel kits · 220 V","offer_id":53217828897066,"sku":"BTS-FS05-2XA03P-220","price":59827.0,"currency_code":"USD","in_stock":true},{"title":"2 × 5 L jacketed vessel kits · 220 V","offer_id":53217828929834,"sku":"BTS-FS05-2XA05P-220","price":65331.0,"currency_code":"USD","in_stock":true},{"title":"2 × 10 L jacketed vessel kits · 220 V","offer_id":53217828962602,"sku":"BTS-FS05-2XA10P-220","price":69543.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-hero.webp?v=1792798224","url":"https:\/\/bluetigerscientific.com\/products\/winpact-fs-05-parallel-bioreactor","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}