{"product_id":"serialized-glass-thermometers","title":"Serialized Glass Thermometers","description":"\u003cdiv class=\"bts-h20o-guide\" style=\"max-width:1080px;margin:auto;color:#26332c;font:400 16px\/1.7 Open Sans,sans-serif\"\u003e\n\u003cnav aria-label=\"Buying guide navigation\" style=\"display:flex;flex-wrap:wrap;gap:6px 18px;border-bottom:1px solid #B7D0BF;padding:10px 0;\"\u003e\u003ca href=\"#bts-hs-9806840103210-guide\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806840103210-guide')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eBuying guide\u003c\/a\u003e\u003ca href=\"#bts-hs-9806840103210-fit\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806840103210-fit')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eFit and selection\u003c\/a\u003e\u003ca href=\"#bts-hs-9806840103210-specs\" onclick=\"var t=document.querySelector('label[for=\u0026quot;pf-tab-ef5c5c09-1\u0026quot;]');if(t){t.click();setTimeout(function(){var e=Array.from(document.querySelectorAll('#bts-hs-9806840103210-specs')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});},80);return false;}\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eSpecs\u003c\/a\u003e\u003ca href=\"#bts-hs-9806840103210-faq\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806840103210-faq')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eFAQs\u003c\/a\u003e\u003ca href=\"#bts-order-options\" onclick=\"var e=document.getElementById('bts-order-options');if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eCompare models\u003c\/a\u003e\u003c\/nav\u003e\u003ch2 id=\"bts-hs-9806840103210-guide\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eChoose a thermometer for your temperature log\u003c\/h2\u003e\n\u003cp style=\"line-height:1.7\"\u003eFor a temperature log, record the serial number on the instrument as well as the reading. Then a later check can be traced to the same thermometer, even if several on the bench have identical scales.\u003c\/p\u003e\n\u003cfigure style=\"display:flex;align-items:center;flex-wrap:wrap;gap:14px 24px;padding:16px;margin:20px 0;border:1px solid #B7D0BF;border-radius:8px\"\u003e\u003cimg alt=\"Representative VEE GEE plain glass thermometer, full-length view\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-SERIALIZED-GLASS-THERMOMETERS-_1629__09229.1717551597.jpg?v=1749333456\" style=\"width:150px;height:300px;max-width:100%;object-fit:contain\"\u003e\u003cfigcaption style=\"flex:1 1 210px\"\u003eFull-length family photograph. The gallery close-up shows the blue bulb, liquid column and etched stem of a representative instrument. Scale markings and immersion design depend on the model.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch2 id=\"bts-hs-9806840103210-fit\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eMatch the immersion method, then the scale\u003c\/h2\u003e\n\u003ch3 style=\"font:600 18px\/1.4 Open Sans,sans-serif;color:#245b45\"\u003eOne range, two different ways to immerse\u003c\/h3\u003e\n\u003cp style=\"font:400 16px\/1.7 Open Sans,sans-serif\"\u003eFor a −20 to 110°C bath, both 80707 and 80907 have 1°C marks. Choose 80707 when the method calls for the bulb and liquid column to be at bath temperature up to the point of reading. Choose 80907 when the bath level must meet the marked immersion line. An identical range does not make these instruments interchangeable.\u003c\/p\u003e\n\u003ch3 style=\"font:600 18px\/1.4 Open Sans,sans-serif;color:#245b45\"\u003eCheck the vessel as well as the upper limit\u003c\/h3\u003e\n\u003cp style=\"font:400 16px\/1.7 Open Sans,sans-serif\"\u003eFor Fahrenheit work up to 230°F, 80702 and 80902 are 12 inches long and read in 2°F steps. If a partial-immersion method needs to reach 250°F, 80910 extends from −10 to 250°F and measures 15.38 inches overall. A longer stem needs more clearance; its overall length is not its immersion depth.\u003c\/p\u003e\n\u003ch2 id=\"bts-hs-9806840103210-faq\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eBuyer FAQs\u003c\/h2\u003e\n\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"line-height:1.7;font-weight:300;color:#333\"\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow do I choose between total and partial immersion?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eUse the design specified in your procedure. For total immersion, expose the bulb and the liquid column up to the reading to the medium, leaving enough of the column visible to read. For partial immersion, bring the medium to the line marked on the stem.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich Celsius model can read below −20°C?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003e80706 (total) and 80906 (partial) cover −35 to 50°C. If your work goes above 50°C, check the upper limit too: the −20 to 110°C and −20 to 150°C pairs do not extend down to −35°C.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich plain model covers 500°F?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003e80905 covers 20 to 500°F in 2°F steps. It is a 15.38-inch partial-immersion thermometer. There is no total-immersion option at that range in this plain series.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes one thermometer show both Celsius and Fahrenheit?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eNo. Each catalog number has one scale. The Celsius models have 1°C subdivisions and the Fahrenheit models have 2°F subdivisions. Choose the scale your record or procedure uses.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes a serial number mean a calibration certificate is included?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eThe number identifies the individual thermometer for your records. It is not a calibration result. If your procedure requires a certificate, specified test points or traceability to a particular standard, confirm those requirements before ordering.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs there a protective coating or a metal guard?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eThese are plain borosilicate glass thermometers with an etched scale and blue fill against a white background. They are not the FEP-encapsulated or armored series. If containment or a guard is required, select a different construction.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat do I receive, and will it fit my setup?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eOne thermometer in the range and immersion type listed for your catalog number. Most models are 12 inches long; 80905 and 80910 are 15.38 inches. Check stem clearance and the required immersion method separately.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Heathrow Scientific","offers":[{"title":"-30 to 120°F \/ 2°F \/ Total","offer_id":50280253423914,"sku":"BTS-80701","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-30 to 120°F \/ 2°F \/ Partial","offer_id":53719718920490,"sku":"BTS-80901","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-4 to 230°F \/ 2°F \/ Total","offer_id":50280253522218,"sku":"BTS-80702","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-4 to 230°F \/ 2°F \/ Partial","offer_id":53719718953258,"sku":"BTS-80902","price":29.0,"currency_code":"USD","in_stock":true},{"title":"0 to 300°F \/ 2°F \/ Total","offer_id":50280253587754,"sku":"BTS-80703","price":29.0,"currency_code":"USD","in_stock":true},{"title":"0 to 300°F \/ 2°F \/ Partial","offer_id":53719718986026,"sku":"BTS-80903","price":29.0,"currency_code":"USD","in_stock":true},{"title":"20 to 500°F \/ 2°F \/ Partial","offer_id":50280253653290,"sku":"BTS-80905","price":36.0,"currency_code":"USD","in_stock":true},{"title":"-35 to 50°C \/ 1°C \/ Total","offer_id":50280253686058,"sku":"BTS-80706","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-35 to 50°C \/ 1°C \/ Partial","offer_id":53719719018794,"sku":"BTS-80906","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-20 to 110°C \/ 1°C \/ Total","offer_id":50280253751594,"sku":"BTS-80707","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-20 to 110°C \/ 1°C \/ Partial","offer_id":53719719051562,"sku":"BTS-80907","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-20 to 150°C \/ 1°C \/ Total","offer_id":50280253817130,"sku":"BTS-80708","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-20 to 150°C \/ 1°C \/ Partial","offer_id":53719719084330,"sku":"BTS-80908","price":29.0,"currency_code":"USD","in_stock":true},{"title":"-10 to 250°F \/ 2°F \/ Partial","offer_id":50280253915434,"sku":"BTS-80910","price":36.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/plain-serialized-thermometer-detail.jpg?v=1795471436","url":"https:\/\/bluetigerscientific.com\/products\/serialized-glass-thermometers","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}