{"product_id":"mtc-bio-microinjection-microcapillary-pipette-tips","title":"MTC Bio Microinjection and Microcapillary Pipette Tips","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-resume30-microinjection-1.jpg?v=1790660545\" alt=\"MTC Bio P5710 manufacturer product image\" style=\"width: 100%; max-width: 440px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%);\"\u003e\n\u003ch3 style=\"font-size: 1.15rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eBack-load glass microinjection capillaries with control.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eP5710 flexible microcapillary pipette tips provide a 0.5–20 µL capacity and an ultra-fine 0.33 mm end. Supplied sterile in a rack of 96, they are tools for filling glass capillaries—not glass injection needles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e0.5–20 µL\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eCapacity\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e0.33 mm\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eFine tip diameter\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e83 mm\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eOverall length\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e96\/pack\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eOne rack\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eDesigned for Your Workflow\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 28px 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eFine flexible end\u003c\/strong\u003e\u003cbr\u003eDesigned for filling glass microinjection capillaries.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eSmall-volume format\u003c\/strong\u003e\u003cbr\u003eA 0.5–20 µL capacity supports controlled small-volume transfer.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003ePipettor selection\u003c\/strong\u003e\u003cbr\u003eFor universal 2 and 10 µL pipettors; 20 µL use requires manual removal.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eSterile rack\u003c\/strong\u003e\u003cbr\u003eOne 96-tip rack is supplied per pack.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 400px; min-width: min(280px, 100%); text-align: center; order: 1;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-resume30-microinjection-2.jpg?v=1790660545\" alt=\"MTC Bio microinjection product detail\" style=\"width: 100%; max-width: 420px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); order: 2;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eSelect the Right Format\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eThe current manufacturer table lists a 56 mm capillary, while the workbook description says 50 mm. Confirm this dimension before any clearance-critical purchase. Do not treat this filling tip as an OEM glass injection needle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eConfigurations and Ordering Units\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px;\"\u003e\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eP5710\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Microinjection \/ Microcapillary Pipette Tips, 0.5 - 20µl capacity, sterile, 83mm length, 56mm capillary (current manufacturer table), fits 2, 10, and 20µL universal pipettors, for use with Femtotips® and other glass capillaries, one rack of 96 tips, 96\/pk\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eOrder unit:\u003c\/strong\u003e 96 per pack\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; columns: 2 260px;\"\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eGlass-capillary back-loading\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eMicroinjection preparation\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eSmall-volume liquid transfer\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eFine gel-loading workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f9f9f9; border: 1px solid #e0e0e0; border-radius: 8px; padding: 24px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eSelection and Use Tip\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003eThe current manufacturer table lists a 56 mm capillary, while the workbook description says 50 mm. Confirm this dimension before any clearance-critical purchase. Do not treat this filling tip as an OEM glass injection needle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs P5710 a glass injection needle?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. It is a flexible pipette tip for filling glass microinjection capillaries and transferring small volumes. The glass capillary is separate.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich pipettors fit?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eMTC Bio specifies universal 2 and 10 µL pipettors. It also states that 20 µL pipettors can be used, but the tip must be removed manually.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat volume range is supported?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe tip capacity is 0.5–20 µL. Use a suitable pipettor and validate the transfer method for your sample.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan it be used with Femtotips?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eMTC Bio describes back-loading glass Femtotips and other glass capillaries. This describes a filling workflow, not OEM status, endorsement or guaranteed interchangeability with every capillary model.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow does it compare with LoadWell P5720?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eP5710 has a 0.33 mm fine end and 0.5–20 µL capacity. LoadWell P5720 has a 0.7 mm orifice and a 200 µL gel-loading format. Choose by capillary access, pipettor fit and volume rather than treating them as equivalent.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat are the overall and capillary lengths?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eOverall length is 83 mm. The current manufacturer ordering table lists a 56 mm capillary; an older workbook description says 50 mm. Confirm the dimension if exact reach is critical.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eAre the tips sterile and how are they packed?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThey are supplied sterile, 96 tips in one rack per pack.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the fine tip guarantee better cell viability?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo outcome guarantee is made here. Cell viability depends on the full preparation and injection method, sample and equipment.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MTC Bio","offers":[{"title":"P5710 | Microinjection Pipette Tips, 10µL, 96 per Rack | 96\/pack","offer_id":52789969158442,"sku":"BTS-P5710","price":119.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-resume30-microinjection-1.jpg?v=1790660545","url":"https:\/\/bluetigerscientific.com\/products\/mtc-bio-microinjection-microcapillary-pipette-tips","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}