{"product_id":"mtc-bio-glass-coated-plates","title":"MTC Bio Glass-Coated Plates – SiO₂ 96 \u0026 384-Well, Shallow \u0026 Deep-Well, ILP","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; background: #fff;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-ILP-DP22VS-9-GC10.jpg\" alt=\"MTC Bio ILP DP22VS-9-GC10 glass-coated 96 square well 2.2 mL V-bottom deep-well plate\" style=\"width: 100%; max-width: 440px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%);\"\u003e\n\u003ch3 style=\"font-size: 1.15rem; font-weight: 400; margin: 0 0 20px 0;\"\u003e\u003cstrong\u003eGlass-Like Surfaces, Plastic Convenience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003e\u003cstrong\u003eWhen your samples are in organic solvent, ordinary polypropylene can leach plasticizers and other extractables into them.\u003c\/strong\u003e These ILP plates carry a thin quartz-glass (SiO\u003csub\u003e2\u003c\/sub\u003e) coating inside every well, so samples touch a glass-like surface while the plate keeps the light weight, toughness, and SBS footprint of plastic.\u003c\/p\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003e\u003cstrong\u003eChoose your plate format in the menu\u003c\/strong\u003e: shallow or deep 96-well round, 96-well square, or 384-well square. Every plate matches the dimensions of a standard ILP plate, so it drops into the same autosamplers, racks, and liquid handlers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003eSiO₂\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eGlass well coating\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e−80 to 80 °C\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003eStable range\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e12 Formats\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003e96 and 384-well\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 180px; min-width: min(160px, 100%); text-align: center; border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px 12px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1.6rem; font-weight: 600; color: #1f6fb2; margin: 0 0 6px 0;\"\u003e10\u003c\/p\u003e\n\u003cp style=\"font-size: 0.9rem; line-height: 1.4; margin: 0;\"\u003ePlates per pack\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eWhy Labs Choose Glass-Coated Plates\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 28px 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eLow Extractables\u003c\/strong\u003e\u003cbr\u003eThe glass layer cuts leachables that can show up as background peaks in LC-MS and GC runs.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eNo Glass Inserts\u003c\/strong\u003e\u003cbr\u003eSkip vial inserts: load samples straight into the plate for high-density storage and injection.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eReduced Oxygen Transmission\u003c\/strong\u003e\u003cbr\u003eThe coating slows oxygen transfer through the plate for more stable samples.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eThermally Stable\u003c\/strong\u003e\u003cbr\u003eChemically and thermally stable from −80 °C to 80 °C.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eAutosampler Ready\u003c\/strong\u003e\u003cbr\u003eStandard SBS footprint for common autosamplers, stackers, and robots.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; min-width: min(260px, 100%); border-left: 3px solid #1f6fb2; padding: 4px 0 4px 16px;\"\u003e\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003e\u003cstrong\u003eFamiliar Formats\u003c\/strong\u003e\u003cbr\u003eSame well shapes and heights as our uncoated ILP plates.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eWhich Plate Do I Need?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eMatch the plate to the height and well format your autosampler or method calls for.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eShallow 96 Round\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eVolumes:\u003c\/strong\u003e 300–500 µL\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 14.4–14.75 mm\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e Autosampler injection and small sample sets\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eDeep 96 Round\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eVolumes:\u003c\/strong\u003e 1.0–2.0 mL\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 31.5–45.3 mm\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e Extractions, dilutions, and larger volumes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003eDeep 96 Square\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eVolumes:\u003c\/strong\u003e 2.0 or 2.2 mL\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 41.2–41.6 mm\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e Maximum volume and mixing\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 240px; min-width: min(240px, 100%); border: 1px solid #e0e0e0; border-radius: 8px; padding: 20px; background: #f9f9f9;\"\u003e\n\u003cp style=\"font-size: 1rem; margin: 0 0 12px 0;\"\u003e\u003cstrong\u003e384 Square\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eVolumes:\u003c\/strong\u003e 120 or 190 µL\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 14.4 or 24.9 mm\u003c\/p\u003e\n\u003cp style=\"font-size: 0.95rem; line-height: 1.6; margin: 0 0 6px 0;\"\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e High-density compound and sample storage\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 400px; min-width: min(280px, 100%); text-align: center; order: 1;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-ILP-DP35UR-9-GC10.jpg\" alt=\"MTC Bio ILP DP35UR-9-GC10 glass-coated 96 round well 500 µL U-bottom plate\" style=\"width: 100%; max-width: 420px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); order: 2;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eBuilt for LC-MS and Solvent Work\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003e\u003cstrong\u003ePlastic extractables are a common source of ghost peaks and ion suppression in mass spectrometry.\u003c\/strong\u003e A glass-coated plate keeps solvent-based samples off bare polypropylene, without the cost and handling of glass vials.\u003c\/p\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eUse them for sample prep, injection, and storage in methods where standard plates add background.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; gap: 40px; border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1 1 400px; min-width: min(280px, 100%); text-align: center; order: 2;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-ILP-DP120-SQ-384-GC10.jpg\" alt=\"MTC Bio ILP DP120-SQ-384-GC10 glass-coated 384 square well 120 µL V-bottom plate\" style=\"width: 100%; max-width: 420px; height: auto; object-fit: contain; border-radius: 8px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 500px; min-width: min(300px, 100%); order: 1;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eSame Footprint as Our Standard Plates\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003e\u003cstrong\u003eEach glass-coated plate is the coated version of a standard ILP plate.\u003c\/strong\u003e If you already run the uncoated plate, the coated one uses the same deck positions, and the same sealing mats should fit.\u003c\/p\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0 0 14px 0;\"\u003eUncoated versions: \u003ca href=\"\/products\/mtc-bio-96-well-storage-plates-0-5ml\" style=\"color: #1f6fb2; font-weight: 600;\"\u003e96-well 0.3–0.5 mL storage plates\u003c\/a\u003e, \u003ca href=\"\/products\/mtc-bio-96-well-deep-well-plates-1ml\" style=\"color: #1f6fb2; font-weight: 600;\"\u003e96-well 1 mL deep-well plates\u003c\/a\u003e, \u003ca href=\"\/products\/mtc-bio-96-well-deep-well-plates-2ml\" style=\"color: #1f6fb2; font-weight: 600;\"\u003e96-well 2 mL deep-well plates\u003c\/a\u003e, and \u003ca href=\"\/products\/mtc-bio-384-well-deep-well-plates\" style=\"color: #1f6fb2; font-weight: 600;\"\u003e384-well deep-well plates\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e0e0e0; padding-bottom: 40px; margin-bottom: 40px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; columns: 2 260px;\"\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eLC-MS and GC-MS sample preparation\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eAutosampler injection plates\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eOrganic solvent extractions\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eCompound library storage in DMSO\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eLeachable-sensitive bioanalysis\u003c\/li\u003e\n\u003cli style=\"font-size: 1rem; line-height: 1.6; margin-bottom: 6px;\"\u003eReplacing glass vials and inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f9f9f9; border: 1px solid #e0e0e0; border-radius: 8px; padding: 24px;\"\u003e\n\u003ch4 style=\"font-size: 1.05rem; font-weight: 400; margin: 0 0 16px 0;\"\u003e\u003cstrong\u003eTip for Sealing Solvent Samples\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"font-size: 1rem; line-height: 1.6; margin: 0;\"\u003ePair a glass-coated plate with a seal that suits your solvent. Our \u003ca href=\"\/products\/mtc-bio-silicone-sealing-mats\" style=\"color: #1f6fb2; font-weight: 600;\"\u003ePTFE-coated silicone sealing mats\u003c\/a\u003e add a chemically resistant, pierceable barrier for autosampler injection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eAre these a good alternative to Thermo Scientific™ WebSeal Plate+ glass-coated plates?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes, for most applications. They are polypropylene plates with an SiO\u003csub\u003e2\u003c\/sub\u003e glass well coating in 96- and 384-well formats, U- and V-bottom, with a standard SBS footprint. Confirm dimensions against your instrument before switching. Thermo Scientific™ and WebSeal Plate+ are trademarks of their respective owners; Blue Tiger Scientific is not affiliated.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is the coating?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eA thin layer of silicon dioxide (quartz glass) on the well surfaces. It gives the wells properties similar to glass while the plate body stays polypropylene.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhy use a glass-coated plate instead of a standard plate?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe coating reduces extractables and leachables and slows oxygen transmission, which matters for solvent-based samples and sensitive LC-MS or GC-MS work.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat temperatures can they handle?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThey are chemically and thermally stable from −80 °C to 80 °C.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow many plates come in a pack?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003e10 plates per pack.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDo standard sealing mats fit?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe plates match the uncoated ILP formats, so mats that fit the uncoated plate should fit the coated one. See our \u003ca href=\"\/products\/mtc-bio-silicone-sealing-mats\" style=\"color: #1f6fb2; font-weight: 600;\"\u003esilicone sealing mats\u003c\/a\u003e.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MTC Bio","offers":[{"title":"96 Round · 300 µL · V-Bottom · 14.6 mm","offer_id":52794615628074,"sku":"BTS-DP36VR-9-GC10","price":614.2,"currency_code":"USD","in_stock":true},{"title":"96 Round · 335 µL · U-Bottom · 14.75 mm","offer_id":52794615660842,"sku":"BTS-DP04UR-9-GC10","price":614.2,"currency_code":"USD","in_stock":true},{"title":"96 Round · 500 µL · U-Bottom · 14.4 mm","offer_id":52794615693610,"sku":"BTS-DP35UR-9-GC10","price":614.2,"currency_code":"USD","in_stock":true},{"title":"96 Round · 1.0 mL · V-Bottom · 33.0 mm","offer_id":52794615726378,"sku":"BTS-DP11VR-9-GC10","price":614.2,"currency_code":"USD","in_stock":true},{"title":"96 Round · 1.1 mL · U-Bottom · 33.0 mm","offer_id":52794615759146,"sku":"BTS-DP10UR-9-GC10","price":614.2,"currency_code":"USD","in_stock":true},{"title":"96 Round · 1.2 mL · U-Bottom · 31.5 mm","offer_id":52794615791914,"sku":"BTS-DP12UR-9-GC10","price":614.2,"currency_code":"USD","in_stock":true},{"title":"96 Round · 1.2 mL · U-Bottom · 42.5 mm","offer_id":52794615824682,"sku":"BTS-DP1M-RD-96-GC10","price":568.7,"currency_code":"USD","in_stock":true},{"title":"96 Round · 2.0 mL · U-Bottom · 45.3 mm","offer_id":52794615857450,"sku":"BTS-DP2M-RD-96-GC10","price":568.7,"currency_code":"USD","in_stock":true},{"title":"96 Square · 2.0 mL · U-Bottom · 41.6 mm","offer_id":52794615890218,"sku":"BTS-DP21US-9-GC10","price":568.7,"currency_code":"USD","in_stock":true},{"title":"96 Square · 2.2 mL · V-Bottom · 41.2 mm","offer_id":52794615922986,"sku":"BTS-DP22VS-9-GC10","price":568.7,"currency_code":"USD","in_stock":true},{"title":"384 Square · 120 µL · V-Bottom · 14.4 mm","offer_id":52794615955754,"sku":"BTS-DP120-SQ-384-GC10","price":614.2,"currency_code":"USD","in_stock":true},{"title":"384 Square · 190 µL · V-Bottom · 24.9 mm","offer_id":52794615988522,"sku":"BTS-DP24VS-384-GC10","price":614.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BTS-ILP-DP36VR-9-GC10.jpg?v=1790712047","url":"https:\/\/bluetigerscientific.com\/products\/mtc-bio-glass-coated-plates","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}