{"product_id":"meiji-techno-emz-5-binocular-zoom-stereo-body","title":"Meiji Techno EMZ-5 Stereo Zoom Microscope Body (0.7–4.5x)","description":"\u003cdiv id=\"bts-meiji-emz5-guide\" style=\"font-family:'Open Sans',Arial,sans-serif;font-weight:300;color:#26332C;max-width:1400px;margin:0 auto;box-sizing:border-box;padding:20px;\"\u003e\n\u003csection style=\"padding:26px;box-sizing:border-box;background:#13314E;border-radius:12px;margin-bottom:24px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.8rem;letter-spacing:.12em;color:#B7D0BF;font-weight:600;\"\u003eMEIJI TECHNO · MODULAR STEREO INSPECTION\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:2rem;line-height:1.2;color:white;font-weight:600;margin:14px 0;\"\u003eSee the detail.\u003cbr\u003eKeep room to work.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:white;\"\u003eBuild a stereo inspection station around the EMZ-5 binocular zoom body. With a separate MA502 10x eyepiece pair, move from a 7x overview to 45x detail without swapping objectives.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;padding:12px;background:#fff;color:#13314E;border-radius:6px;font-weight:600;line-height:1.6;\"\u003eBody only. Eyepieces, stand, focusing holder and light are separate unless you already own a compatible setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca data-meiji-zoom=\"true\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-body.jpg?v=1793833911\" rel=\"noopener\" style=\"display:block;\" target=\"_blank\"\u003e\u003cimg alt=\"EMZ-5 body only. Eyepieces, stand and lighting are not included.\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-body.jpg?v=1793833911\" style=\"display:block;width:100%;max-width:440px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eEMZ-5 body only. Eyepieces, stand and lighting are not included. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003e0.7–4.5x optical zoom\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e7–45x total magnification with the optional MA502 10x pair; the body does not include eyepieces.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003e93 mm working distance\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eClearance between the standard objective and specimen at focus. It is not the stand height or focus travel.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eTwo-eye stereo view\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eGreenough optics provide an erect, unreversed stereo image for surface inspection and hands-on work.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eStart here: replacing a body or building a workstation?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eI already have an EM-series setup\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose the body after confirming your holder, eyepieces and illumination. The manufacturer pairs EMZ-5 with its F holder; a similar-looking generic holder is not automatically compatible.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eI need a compact bench microscope\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse EMZ-5 + MA502 pair + P stand + MA302 adapter + MA961D\/S\/ESD light. The P stand already includes the F holder.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eI need more access around a large part\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse EMZ-5 + MA502 pair + F holder + S-4100 or S-4200 + MA302 adapter + MA961D\/S\/ESD light. Choose one stand, not both.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe setup examples below are component shopping lists, not a claim that the body-only price includes a complete microscope. Order the body above and the selected components in the accessory grids.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose your EMZ-5 setup by the work you do\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003eThe same stereo zoom body can serve different benches. Start with the task and specimen, then choose support, clearance and illumination. The examples below use the standard 7–45x configuration with the separately selected MA502 10x pair.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:18px;align-items:stretch;\"\u003e\n\u003carticle style=\"flex:1 1 270px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#fff;\"\u003e\u003cfigure style=\"margin:0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-emz5-application-electronics.webp?v=1793892490\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-emz5-application-electronics.webp?v=1793892490\" alt=\"Original illustration of a circuit board and precision tweezers; electronics application context only\" width=\"1000\" height=\"750\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;object-fit:contain;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.78rem;line-height:1.5;padding:8px 16px;color:#526358;\"\u003eApplication illustration—not an EMZ-5 microscope image. Select to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv style=\"padding:18px;box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.15rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 14px;\"\u003eElectronics \u0026amp; precision assembly\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eFor boards, connections and small assemblies.\u003c\/strong\u003e Use stereo depth perception to examine accessible solder joints, component placement and surface condition, or to position tools during assembly and rework.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eChoose your support:\u003c\/strong\u003e consider a boom for positioning over larger boards; the compact P route suits work that fits comfortably on its base.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eCheck before ordering:\u003c\/strong\u003e confirm tool clearance and lighting. MA517 trades magnification for clearance; check light mounting again when adding it. An ESD-rated illuminator does not certify the entire workstation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 270px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#fff;\"\u003e\u003cfigure style=\"margin:0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-emz5-application-biology.webp?v=1793892492\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-emz5-application-biology.webp?v=1793892492\" alt=\"Original illustration of a beetle, plant leaflet, seeds and tweezers on a sorting tray; biological application context only\" width=\"1000\" height=\"750\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;object-fit:contain;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.78rem;line-height:1.5;padding:8px 16px;color:#526358;\"\u003eApplication illustration—not an EMZ-5 microscope image. Select to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv style=\"padding:18px;box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.15rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 14px;\"\u003eBiological dissection \u0026amp; specimen sorting\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eFor dissection and larger biological specimens.\u003c\/strong\u003e Examine external insect structures, sort seeds and plant material, or manipulate a specimen while retaining a three-dimensional view.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eChoose your support:\u003c\/strong\u003e consider P for small specimens on its reversible black\/white plate. A boom leaves more freedom to position larger trays and tools beneath the body.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eCheck before ordering:\u003c\/strong\u003e the selected ring-light routes illuminate from above; they do not include transmitted light. This is not a substitute for a compound microscope for high-power slides or an inverted cell-culture instrument.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 270px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#fff;\"\u003e\u003cfigure style=\"margin:0;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-emz5-application-qc.webp?v=1793892491\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-emz5-application-qc.webp?v=1793892491\" alt=\"Original illustration of a metal sleeve, brass fitting and molded connector housing; quality-control application context only\" width=\"1000\" height=\"750\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;object-fit:contain;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.78rem;line-height:1.5;padding:8px 16px;color:#526358;\"\u003eApplication illustration—not an EMZ-5 microscope image. Select to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv style=\"padding:18px;box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.15rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 14px;\"\u003eManufacturing \u0026amp; component QC\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eFor manufactured parts and precision components.\u003c\/strong\u003e Inspect accessible surfaces, edges, alignment and assembly condition, including appropriate medical-device components during manufacturing—not clinical diagnosis or treatment.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eChoose your support:\u003c\/strong\u003e use the compact route for small parts; consider the boom route for larger assemblies or repeated access around the workpiece.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003e\u003cstrong\u003eCheck before ordering:\u003c\/strong\u003e illumination and visibility depend on the material and geometry. The standard setup does not provide certified measurements, automated defect detection or visibility inside hidden joints.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;line-height:1.75;font-weight:300;margin:0 0 14px;\"\u003eThese are application examples, not sample images captured with the microscope. Product and configuration photographs elsewhere on this page are authentic Meiji imagery. Order the body and selected setup components separately.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eSetup 1 · A compact, illuminated bench station\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca data-meiji-zoom=\"true\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-compact.jpg?v=1793833990\" rel=\"noopener\" style=\"display:block;\" target=\"_blank\"\u003e\u003cimg alt=\"Manufacturer configuration example: EMZ-5 + MA502 + P + MA302 + MA961D\/S\/ESD. Components ordered separately.\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-compact.jpg?v=1793833990\" style=\"display:block;width:100%;max-width:600px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer configuration example: EMZ-5 + MA502 + P + MA302 + MA961D\/S\/ESD. Components ordered separately. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eFor small parts and routine bench inspection.\u003c\/strong\u003e This manufacturer-listed configuration puts the specimen on a compact base rather than suspending the body from a boom. The P stand has a 150 × 230 mm base, a reversible black\/white plate and stage clips.\u003c\/p\u003e\n\u003cul style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;padding-left:22px;\"\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eEMZ-5 binocular zoom body\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eMA502 10x eyepieces — one pair\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eP plain pole stand — F focus holder already included\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eMA302 ring-light adapter\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eMA961D\/S\/ESD ring light — supplied controller and power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eAvoid a duplicate purchase:\u003c\/strong\u003e do not add another F holder when choosing the P stand. The stand already supplies it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose your eyepieces and support\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSelect the MA502 pair and one support route. A boom route also needs F; the P route does not need an extra F. Prices below come directly from each accessory’s current selling price.\u003c\/p\u003e\n\u003cdiv data-bts-accessory-slot=\"emz5-support\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eSetup 2 · Put the work under the microscope, not on a small base\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eFor larger boards, parts and assemblies.\u003c\/strong\u003e The boom arrangement lets you position the optical body above a work area and swing it aside when the station is needed for another task. Both stands use a 530 mm horizontal arm; S-4200 adds vertical positioning room, not extra reach.\u003c\/p\u003e\n\u003cul style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;padding-left:22px;\"\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eEMZ-5 binocular zoom body\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eMA502 10x eyepieces — one pair\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eF coarse-focus holder\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eOne boom stand: S-4100 or S-4200\u003c\/li\u003e\n\u003cli style=\"font-family:'Open Sans',Arial,sans-serif;\"\u003eMA302 adapter + MA961D\/S\/ESD light system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe F holder provides 55 mm of coarse-focus travel. Set the stand height for the specimen first, then focus with the holder. Keep the support stable and secure the stand and body according to the manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca data-meiji-zoom=\"true\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-boom.jpg?v=1793833910\" rel=\"noopener\" style=\"display:block;\" target=\"_blank\"\u003e\u003cimg alt=\"Manufacturer EMZ-5 + MA502 + F + S-4200 example. No ring light is pictured; lighting is separate.\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-boom.jpg?v=1793833910\" style=\"display:block;width:100%;max-width:600px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer EMZ-5 + MA502 + F + S-4200 example. No ring light is pictured; lighting is separate. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eS-4100 or S-4200? Choose height, not a bigger zoom range\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eS-4100 · 400 mm vertical pole\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eStandard-height boom choice with a 530 mm horizontal arm. Add the separate F holder for this EMZ-5 route.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eS-4200 · 610 mm vertical pole\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAdds 210 mm of vertical pole height. The horizontal arm is still 530 mm; the standard optical working distance stays 93 mm.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eCheck the specimen’s height, the bench position, the full arm sweep and overhead clearance. Pole length is not a guarantee of usable specimen clearance; the complete head, holder and lighting arrangement also occupy space.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eLight the surface you actually need to inspect\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca data-meiji-zoom=\"true\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-ring.jpg?v=1793833912\" rel=\"noopener\" style=\"display:block;\" target=\"_blank\"\u003e\u003cimg alt=\"MA961D\/S\/ESD ring-light photograph. The controller and power supply are supplied but not pictured.\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-ring.jpg?v=1793833912\" style=\"display:block;width:100%;max-width:350px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA961D\/S\/ESD ring-light photograph. The controller and power supply are supplied but not pictured. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eExternal illumination is part of a usable setup.\u003c\/strong\u003e The EMZ-5 body has no built-in lamp. The manufacturer-listed MA961D\/S\/ESD daylight ring light uses the MA302 adapter on the standard EMZ body and includes its controller and power supply.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eStart with moderate brightness and adjust the light and specimen position to reveal surface detail. Highly reflective parts may require a different illumination strategy; more light does not automatically mean more visible detail.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe mounting adapter is specific to the selected light arrangement. Do not assume every ring light uses MA302, or that fitting an auxiliary lens leaves the same mounting arrangement unchanged.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eAdd lighting—or change the clearance deliberately\u003c\/h2\u003e\n\u003cdiv data-bts-accessory-slot=\"emz5-lighting\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 22px;margin-bottom:24px;border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eNeed more tool clearance? Know what 0.5x changes\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eThe MA517 is an optional optical tradeoff, not a stand extension.\u003c\/strong\u003e With the MA502 10x pair, it changes total magnification from 7–45x to 3.5–22.5x and increases working distance to nominally 150 mm. Meiji’s optical chart lists 148 mm for this EMZ-5 combination; use that figure when checking close clearances.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose it when access matters more than maximum magnification. Retain the standard optics when you need the top end of the normal range. Confirm the ring-light mounting arrangement before ordering a combined auxiliary-lens and lighting setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca data-meiji-zoom=\"true\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-aux.jpg?v=1793833989\" rel=\"noopener\" style=\"display:block;\" target=\"_blank\"\u003e\u003cimg alt=\"MA517 auxiliary lens: two manufacturer views of one lens, not a two-lens pack.\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-aux.jpg?v=1793833989\" style=\"display:block;width:100%;max-width:440px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-family:'Open Sans',Arial,sans-serif;font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA517 auxiliary lens: two manufacturer views of one lens, not a two-lens pack. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eUnderstand the three numbers competitors often mix together\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eMagnification\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eOptical body zoom × eyepiece power × auxiliary-lens factor. Standard example: 0.7–4.5 × 10 = 7–45x.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eWorking distance\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSpace from the objective to the specimen at focus: 93 mm in the standard setup. It changes with auxiliary optics.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eStand height and focus travel\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe stand positions the body; F provides 55 mm of fine positioning through its coarse-focus mechanism. Neither number is the optical working distance.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eEMZ-5, EMZ-5D or EMZ-5TR?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eEMZ-5 · Visual inspection\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThis binocular body is the straightforward choice when the work is viewed through two eyepieces. The base model does not supply a trinocular photo port or click-stop detents.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eEMZ-5D · Return to zoom settings\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA different body with detent stops for repeatable magnification settings. It is not a feature added to this base EMZ-5 by selecting different eyepieces.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eEMZ-5TR · Plan imaging from the start\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA different trinocular body for camera integration. A suitable camera and adapter are separate. Its splitter diverts the left optical path to the photo tube; do not assume simultaneous stereo viewing while photographing.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eWhat comes with this order—and what does not\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eBody-only order\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eEMZ-5 binocular stereo zoom body. The EMZ-5 product data sheet also lists MA600 paired eyeshields and MA703 vinyl dust cover.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eSelect separately\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eEyepieces, support stand, focus holder when not part of the chosen stand, illumination, mounting adapter and any auxiliary lens. Cameras and imaging adapters are not included.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe gallery and setup examples intentionally show both the body and assembled configurations. Captions distinguish the orderable body from separately selected components.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eSet up once, then inspect comfortably\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003e1 · Stabilize and position\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSecure the stand and focus holder following the manual. Start with the body above the specimen and low zoom; do not use the focus knob to compensate for an incorrectly positioned stand.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003e2 · Match the two views\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSet the interpupillary spacing for one circular field. Use the manual’s focus and individual diopter procedure; both eyetubes provide diopter adjustment.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.1rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003e3 · Set lighting, then zoom\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAdjust illumination for the surface. Move from overview to detail with the side zoom controls; refocus when specimen height changes. Keep optics clean and covered between sessions.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:26px 0;margin-bottom:24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose a different microscope when the job changes\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe EMZ-5 is a stereo surface-inspection platform—not an inverted cell-culture microscope or a high-power compound microscope for thin slides.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor a different application, compare our \u003ca href=\"\/products\/meiji-techno-tc-5400l-trinocular-contrast-biological-microscope\" style=\"color:#245B45;\"\u003eMeiji TC-5400L inverted phase-contrast microscope\u003c\/a\u003e for cell-culture observation. It is an alternative instrument type, not an EMZ-5 accessory.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;padding-top:24px;line-height:1.15;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eEMZ-5 buying questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs the EMZ-5 a complete microscope?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. This listing is for the EMZ-5 body. A complete usable setup also needs a matched eyepiece pair, suitable stand and focusing holder, and external illumination. The P stand already includes F; the S-4100 and S-4200 routes require it separately.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhy does the body say 0.7–4.5x while the setup says 7–45x?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe first number is the optical body zoom. Multiplying by a separate 10x eyepiece pair gives 7–45x total magnification. Changing eyepieces or adding an auxiliary lens changes total magnification.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eHow many MA502 eyepieces should I order?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eOrder quantity 1 of MA502 for one paired set of two 10x eyepieces. The standard EMZ-5 setup does not use the MA522 pair intended for high-eyepoint H-series heads.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eDo I need both the P stand and F holder?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo additional F is needed with the P plain pole stand because it includes that holder. For an EMZ-5 setup on S-4100 or S-4200, order the separate F holder.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eDoes S-4200 give more working distance than S-4100?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. It has a taller vertical pole: 610 mm instead of 400 mm. Both use a 530 mm horizontal arm. The standard EMZ-5 optics retain 93 mm working distance; changing stand height does not change that optical specification.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eCan I attach a camera to this binocular EMZ-5?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThis body does not have the dedicated trinocular photo port of EMZ-5TR. If imaging is essential, choose the imaging body and verify the exact camera\/adapter pairing before ordering rather than adding a C-mount adapter to this binocular body.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhat does the MA517 auxiliary lens change?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIt halves magnification: the 7–45x setup with 10x eyepieces becomes 3.5–22.5x. It provides nominal 150 mm working distance; Meiji’s chart lists 148 mm for EMZ-5. Check lighting fit again when adding it.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"font-family:'Open Sans',Arial,sans-serif;padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eCan I request a quote for the body and selected parts?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eYes. Use the page’s quote controls for the selected items and review the exact components and quantities in the Quote Cart before submitting. Each component is a separate order line; the body price does not include the accessory grid. Shipping, availability and the requested configuration are confirmed with the quote.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49438098882858,"sku":"Meiji Techno EMZ-5","price":1410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-emz5-body.jpg?v=1793833911","url":"https:\/\/bluetigerscientific.com\/products\/meiji-techno-emz-5-binocular-zoom-stereo-body","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}