{"product_id":"major-science-winpact-wp-cos-co2-resistant-orbital-shaker","title":"Winpact WP-COS CO2-Resistant Orbital Shaker","description":"\u003cdiv id=\"bts-major-wp-cos\" style=\"width:100%;max-width:1400px;margin:0 auto;padding:16px clamp(0px,1vw,12px);box-sizing:border-box;background:#fff;color:#26332C;font-family:'Open Sans',sans-serif;font-size:1rem;font-weight:300;line-height:1.75;\"\u003e\n\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;font-size:.85rem;letter-spacing:.06em;\"\u003e\u003cstrong\u003eMAJOR SCIENCE · WINPACT · WP-COS\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eAdd orbital motion to your incubator workflow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe Winpact WP-COS is an orbital shaker designed for use inside a suitable CO2 incubator. It is not an incubator and does not provide its own temperature, humidity or CO2 control. Major Science specifies corrosion-resistant construction to help protect internal components in high-CO2, humid conditions.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA brushless motor drives a 20 mm orbit across the 300 x 300 mm platform. The separate 12-inch color touch controller provides speed adjustment and continuous, timed or programmable operation, allowing you to select the run style that fits your protocol.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:620px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-shaker-and-touch-controller.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-shaker-and-touch-controller.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-shaker-and-touch-controller.webp?v=1792864030\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-shaker-and-touch-controller.webp?v=1792864030\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-shaker-and-touch-controller.webp?v=1792864030\u0026amp;width=1400 1400w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 620px\" width=\"2000\" height=\"1117\" alt=\"Winpact WP-COS orbital shaker base and separate 12-inch touch controller; flask and blue sticky pad are illustrative, not included accessories\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer WP-COS photograph. The flask, liquid and blue sticky pad illustrate a setup and are not the stated flat-mat package. Display settings are examples.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e1 to 300 rpm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eShaking speed\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e20 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eOrbital diameter\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e300 x 300 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003ePlatform\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e5.2 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMaximum load\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWhy laboratories choose this format\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eIncubator-based mixing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAdd a purpose-designed orbital shaker to a suitable host CO₂ incubator, instead of assuming an ordinary bench shaker is suitable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eSeparate touch control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse the 12-inch panel for continuous, timed or programmable operation. Agree controller placement and cable routing for the site.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eDefined mixing format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA brushless motor, 20 mm orbit and 300 × 300 mm platform provide clear parameters for a fit and load review.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWhich Winpact shaking format do I need?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eSI-910\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eRefrigerated, non-CO₂ format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e25 mm orbit; 10–300 rpm; 4–60°C at 23–25°C ambient. No CO₂ or humidity control specified.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eSI-960\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eRefrigerated CO₂ format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e50 mm orbit; 10–180 rpm; 4–60°C at 23–25°C ambient. 0.1–20% CO₂; 50–95% RH; HEPA optional.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;padding:20px;border:2px solid #245B45;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eWP-COS · Current model\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eShaker for an existing incubator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e20 mm orbit; 1–300 rpm; 300 × 300 mm platform. Requires a suitable host incubator for environmental control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;font-size:.88rem;\"\u003eThese are different instrument formats, not interchangeable configurations or upgrade promises. Select the complete system around the conditions your protocol requires.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eCheck the chamber before choosing the shaker\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe base measures approximately 310 x 310 x 97 mm including the tray platform. Use these dimensions as the starting point for a fit check, then account for vessel height, holders, orbital movement, ventilation and cable routing. The published base dimensions are not a minimum incubator chamber specification.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConfirm the incubator shelf loading limit against the base mass of approximately 7.15 kg plus the planned load. The controller measures 320 x 102 x 246 mm and weighs approximately 4.65 kg. Controller placement, cable access and required clearances should be agreed for the installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:560px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-platform-alternate-view.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-platform-alternate-view.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-platform-alternate-view.webp?v=1792864030\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-platform-alternate-view.webp?v=1792864030\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-platform-alternate-view.webp?v=1792864030\u0026amp;width=1400 1400w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 560px\" width=\"1508\" height=\"1001\" alt=\"Elevated manufacturer view of the WP-COS platform, shaker base and touch controller with an illustrative flask and optional blue pad\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer alternate view. Base dimensions do not include the clearance needed for your vessels, holders, movement and cable.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:420px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-touchscreen-example.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-touchscreen-example.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-touchscreen-example.webp?v=1792864030\u0026amp;width=491 491w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 420px\" width=\"491\" height=\"370\" alt=\"Manufacturer WP-COS touchscreen illustration with example speed and time settings; display values do not establish timer or program limits\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer interface illustration. Values shown are examples, not a published maximum timer range or program-step count.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eSelect speed and run mode at the touch panel\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe 12-inch color touch panel supports continuous, timed and programmable modes. Shaking speed is adjustable from 1 to 300 rpm in 1 rpm steps, and the specification also lists a 0 rpm setting.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor protocols that depend on a particular timing range, sequence length or saved-program workflow, confirm those details before purchase. The public specification does not define program-step limits, stored recipe capacity or the full timer range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eMatch vessel retention to your experiment\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe 300 x 300 mm platform has a 316L top plate. Major Science lists strip springs, a 200 x 200 mm sticky pad, 300 x 300 mm dimpled and flat mats, and flask holders in nominal sizes from 50 to 2000 mL as accessories for this model.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose retention accessories around the actual vessel geometry, working load and intended speed. Holder size is not a claim about how many vessels fit on the platform or how much culture volume the shaker can process. Confirm the accessory arrangement rather than using photographs as a packing list.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:760px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-accessory-overview.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-accessory-overview.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-accessory-overview.webp?v=1792864030\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-accessory-overview.webp?v=1792864030\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-accessory-overview.webp?v=1792864030\u0026amp;width=1000 1000w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 760px\" width=\"1000\" height=\"417\" alt=\"Manufacturer WP-COS accessory diagram showing strip springs, sticky pad, dimpled mat, flat mat and flask holders; selected separately as required\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer accessory overview. The flat-mat platform is in the listed configuration; sticky pad, dimpled mat, springs and holders are separate selections.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eConfirm the environmental operating envelope\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe WP-COS is specifically described as a CO2-resistant orbital shaker for incubator use. The reviewed public manufacturer materials do not state numerical temperature, relative-humidity or CO2 concentration limits for this model.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eProvide the proposed incubator model and operating conditions when confirming suitability. Cable length, feed-through compatibility, controller placement and any cleaning or decontamination requirements also need to be checked. Do not assume compatibility with every incubator or its sterilization cycle.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eSpecify the complete configuration\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe listed WP-COS configuration combines the orbital shaker, 12-inch color touch controller and flat-mat platform. A blue sticky pad is a different retention option, not the stated flat-mat configuration.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConfirm the supplied cable and its length, the final platform assembly and any additional vessel-retention accessories when defining the order. An incubator, glassware, blue sticky pad and pictured flask holders are not part of that stated configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:300px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-optional-sticky-pad-detail.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-optional-sticky-pad-detail.webp?v=1792864030\u0026amp;width=263 263w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 300px\" width=\"263\" height=\"239\" alt=\"Optional PPL-04-SI-SI-200-3 sticky pad detail from the WP-COS accessory diagram; different from the supplied flat-mat platform\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eOptional sticky pad PPL-04-SI-SI-200-3, 200 × 200 mm. This is not the flat-mat platform stated in the WP-COS ordering configuration.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eA practical incubator fit check\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e1 · Space and access\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eStart with the approximately 310 × 310 × 97 mm base envelope, then add your vessel height, retaining hardware, motion clearance and access.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e2 · Shelf and load\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eCheck the host shelf rating for the approximately 7.15 kg base plus the planned load. The shaker maximum load is 5.2 kg.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e3 · Conditions and cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConfirm temperature, humidity, CO₂ conditions, cable reach and routing. Published base size does not establish a universal incubator fit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003ePlanning tip:\u003c\/strong\u003e A nominal 2000 mL holder size does not establish platform vessel count, culture working volume or compatibility with a particular incubator.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eSee the WP-COS manufacturer demonstration\u003c\/h2\u003e\n\u003cdiv style=\"position:relative;width:100%;aspect-ratio:16\/9;max-width:900px;margin:0 auto;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/MoQdNF4d5M8\" title=\"Major Science Winpact WP-COS CO2-resistant orbital shaker demonstration\" loading=\"lazy\" allow=\"accelerometer; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen style=\"display:block;width:100%;height:100%;border:0;\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;font-size:.87rem;\"\u003eExact-model manufacturer demonstration. Any labware and optional retention accessories shown are illustrative. No additional timer, programming or environmental limits are inferred from the display.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eOther laboratory workflows\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;padding:18px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eAlternative format\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/products\/major-science-orbital-shaker-ms-nor-30-ms-nor-3001?variant=50042155139370\" style=\"color:#245B45;font-weight:600;text-decoration:underline;\"\u003eMS-NOR-3001 anti-moisture orbital shaker\u003c\/a\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA different orbital format for a separately defined bench or chamber workflow. Review its lower published speed range and different load rating; it is not an integrated incubator or a like-for-like replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;padding:18px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eRelated workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/products\/major-science-digital-peristaltic-pump-mu-d?variant=50042105692458\" style=\"color:#245B45;font-weight:600;text-decoration:underline;\"\u003eMU-D01 digital peristaltic pump\u003c\/a\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eExplore a separate liquid-transfer step. Tubing and flow requirements are selected independently; no mechanical, electrical or automated integration with this shaker is implied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; line-height:1.15; box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eWP-COS buyer questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs the WP-COS an incubator?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. It is an orbital shaker intended for use inside a suitable CO2 incubator. The incubator supplies the controlled environment; the WP-COS supplies the shaking motion.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWill it fit my CO2 incubator?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eFit must be checked for your chamber. The base is approximately 310 x 310 x 97 mm including the tray platform. Allow additional space for vessels, holders, orbital movement and cable routing, and check the shelf load limit against the approximately 7.15 kg base plus the planned load.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat speeds and orbit does it provide?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe WP-COS provides a 20 mm orbital diameter and shaking speeds from 1 to 300 rpm in 1 rpm steps. The manufacturer also lists a 0 rpm setting. Its published maximum load is 5.2 kg.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes it support timed or programmed operation?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. Continuous, timed and programmable modes are specified through the 12-inch color touch panel. The public specification does not confirm timer limits, program-step counts or stored-program capacity.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat comes with the WP-COS?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe listed WP-COS configuration includes the orbital shaker with a 12-inch color touch controller and flat-mat platform. Confirm the supplied cable and its length and any additional retention accessories on your quotation. The incubator, glassware, blue sticky pad and pictured holders are not established as included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich vessel accessories are available?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eListed options include 265 mm strip springs, a 200 x 200 mm sticky pad, 300 x 300 mm dimpled and flat mats, and flask holders sized from 50 to 2000 mL. Confirm fit for your specific vessels and intended speed. The listing does not establish vessel counts or total culture volume.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat temperature, humidity and CO2 levels can it withstand?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNumerical limits are not stated in the reviewed public manufacturer specifications. The manufacturer describes corrosion-resistant construction for high-CO2, humid conditions, but suitability for your operating conditions and any incubator decontamination cycle needs confirmation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs it the same product as the MS-NOR-3001 anti-moisture shaker?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. The WP-COS is a separate Winpact model with a brushless motor, 12-inch touch controller and a stated 1 to 300 rpm shaking range. MS-NOR-3001 belongs to the MS orbital shaker range. Do not transfer package contents, capacities or environmental limits between these models.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Major Science","offers":[{"title":"Default Title","offer_id":53217562263850,"sku":"BTS-WP-COS","price":3372.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-wp-cos-shaker-and-touch-controller.webp?v=1792864030","url":"https:\/\/bluetigerscientific.com\/products\/major-science-winpact-wp-cos-co2-resistant-orbital-shaker","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}