{"product_id":"major-science-winpact-si-970-co2-incubator-shaker-dry-heat","title":"Winpact SI-970 CO2 Incubator Shaker | Dry Heat","description":"\u003cdiv id=\"bts-major-si-970\" style=\"width:100%;max-width:1400px;margin:0 auto;padding:16px clamp(0px,1vw,12px);box-sizing:border-box;background:#fff;color:#26332C;font-family:'Open Sans',sans-serif;font-size:1rem;font-weight:300;line-height:1.75;\"\u003e\n\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 24px;border-bottom:1px solid #E9CDA8;background:#FFF4E6;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;font-size:.85rem;letter-spacing:.06em;\"\u003e\u003cstrong\u003eMAJOR SCIENCE · WINPACT · SI-970\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eBring dry-heat treatment into the shaker workflow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe Winpact SI-970 is the dry-heat model in the stackable CO₂ incubator shaker family. Its manufacturer-listed 180°C dry-heat treatment sets it apart from SI-950 moist heat and the UV function on SI-960, while retaining 50 mm orbital shaking at 10 to 180 rpm.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor culture runs, incubation remains ambient to 60°C at 23 to 26°C ambient. SI-970 has no refrigeration and no UV germicidal lamp. The dry-heat temperature describes a separate treatment function, not a wider incubation range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:620px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-single-module-family.webp?v=1792943710\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-single-module-family.webp?v=1792943710\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-single-module-family.webp?v=1792943710\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-single-module-family.webp?v=1792943710\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-single-module-family.webp?v=1792943710\u0026amp;width=1400 1400w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 620px\" width=\"1450\" height=\"767\" alt=\"Winpact stackable incubator-shaker family reference showing a single module; supplied quantity and labware are confirmed for the order\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer family reference showing a single-module arrangement. The order determines supplied module count and accessories; labware shown is illustrative.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003e180°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eDry Heat treatment\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003e50 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eOrbit diameter\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eAmbient to 60°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIncubation at 23 to 26°C ambient\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003e0.1 to 20%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eCO₂ control range\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eWhy laboratories choose this format\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eDefined treatment choice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose 180°C dry heat as a separate manufacturer-listed chamber treatment, not a wider incubation range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eControlled chamber atmosphere\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eCO₂ 0.1–20% and a 50–95% RH specification support selection against an existing protocol. HEPA is optional.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eAccessible working area\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA 91 × 50 cm slide-out platform, glide-up door and touchscreen support daily setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eWhich SI model fits my workflow?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eSI-910 · Refrigerated \/ UV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e25 mm orbit; 10–300 rpm. No CO₂ or humidity control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eSI-960 · Refrigerated \/ CO₂ \/ UV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e50 mm orbit; 10–180 rpm. CO₂ and humidity capabilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eSI-950 · Non-refrigerated \/ moist heat\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e50 mm orbit; 10–180 rpm. Separate 90°C moist-heat treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eSI-970 · Current model · Non-refrigerated \/ dry heat\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e50 mm orbit; 10–180 rpm. Separate 180°C dry-heat treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSI-910 and SI-960 specify refrigerated incubation at 4–60°C. SI-950 and SI-970 specify ambient–60°C incubation, not incubation at their heat-treatment temperatures. Each range has stated ambient test conditions. These are different model choices, not upgrade promises.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 24px;border-bottom:1px solid #E9CDA8;background:#FFF4E6;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eChoose dry heat without changing the incubation range\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSI-970 lists a 180°C dry-heat treatment rather than the SI-950's 90°C moist-heat method. This is the main selection difference between the two non-refrigerated CO₂ models; their current shaking, orbit and incubation specifications are the same.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eReview the manufacturer's preparation, removal and cooling instructions before operating the heat function. The published temperature does not establish a cycle duration, permission to heat loaded labware or a validated sterility guarantee. Routine incubation is still limited to ambient to 60°C under the stated conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:560px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-heat-method-guide.webp?v=1792943710\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-heat-method-guide.webp?v=1792943710\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-heat-method-guide.webp?v=1792943710\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-heat-method-guide.webp?v=1792943710\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-heat-method-guide.webp?v=1792943710\u0026amp;width=1200 1200w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 560px\" width=\"1200\" height=\"1120\" alt=\"Blue Tiger Scientific specification guide: SI-950 90°C moist heat versus SI-970 180°C dry heat; both incubate from ambient to 60°C under stated conditions\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eBlue Tiger Scientific specification comparison. Treatment temperatures are separate from incubation. This schematic is not a validated treatment procedure.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eMatch CO₂, humidity and motion to your process\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA 50 mm orbit and 10 to 180 rpm shaking range pair with CO₂ control from 0.1 to 20%. The infrared CO₂ sensor has manufacturer-listed accuracy of ±0.1% and stability of ±0.5%. Relative humidity is specified from 50 to 95% RH.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eHEPA filtration is an option, not a standard inclusion. Confirm the gas and water requirements for the final configuration rather than assuming service hardware is supplied.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:600px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-chamber-detail.webp?v=1792943710\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-chamber-detail.webp?v=1792943710\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-chamber-detail.webp?v=1792943710\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-chamber-detail.webp?v=1792943710\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-chamber-detail.webp?v=1792943710\u0026amp;width=1000 1000w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 600px\" width=\"1000\" height=\"415\" alt=\"Detail of the Winpact incubator-shaker family chamber with illustrative flask arrangement; holders and labware are not established as supplied\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer family chamber detail. Listed layouts are alternatives, not supplied flask or holder quantities.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eCheck the flask layout before choosing holders\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe 91 × 50 cm slide-out platform and glide-up door provide access for routine loading. The platform and inner chamber are SUS316L stainless steel, and internal illumination supports visual checks.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFamily maximum-capacity examples are 50 × 250 mL, 32 × 500 mL, 18 × 1000 mL or 15 × 2000 mL. These are alternative layouts, not supplied quantities. Check flask dimensions, retaining hardware and permitted speed together; larger or different vessels can change the usable layout.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #e0e0e0; table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background: #f5f5f5; text-align: left; padding: 12px; font-weight: 700;width:50%;\"\u003eNominal flask size\u003c\/th\u003e\n\u003cth style=\"background: #f5f5f5; text-align: left; padding: 12px; font-weight: 700;width:50%;\"\u003eAlternative family maximum\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e250 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e50 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e500 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e32 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e1000 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e18 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e2000 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e15 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eUse touchscreen control without assuming a fixed recipe\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA 10-inch capacitive LCD touchscreen supports PID control and a manually editable program. The manufacturer specifies a timer of 9999 minutes or 9999 hours, a servo motor and forced internal air circulation.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose operating settings around your process. The published specification does not establish a number of program steps or a heat-treatment duration; use the model-specific operating procedure for those details.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 24px;border-bottom:1px solid #E9CDA8;background:#FFF4E6;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003ePlan the room, power and stack arrangement\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe specified operating ambient range is 20 to 27°C. Electrical supply is single-phase 110 V or 220 V, 50\/60 Hz. Confirm the required voltage and final connection details before ordering; the 800 W heating-power figure is not a total electrical-input rating.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eStacking can help organize capacity vertically, but the illustrated three-module arrangement is not a package statement. Confirm supplied modules, stacking hardware, final installation dimensions, floor loading and service clearances for your order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:420px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-stack-illustration.webp?v=1792943710\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-stack-illustration.webp?v=1792943710\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-stack-illustration.webp?v=1792943710\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-stack-illustration.webp?v=1792943710\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-stack-illustration.webp?v=1792943710\u0026amp;width=1200 1200w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 420px\" width=\"1200\" height=\"1200\" alt=\"Manufacturer Winpact three-module stack illustration; not a supplied package quantity or exact-model nameplate photograph\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eIllustrative manufacturer three-module stack, not the supplied quantity, an installation drawing or a shipping-weight statement.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eTypical application fit\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eCO₂-controlled shaking\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor workflows requiring regulated chamber CO₂ with 50 mm orbital shaking. Confirm the intended vessels, load and culture conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eChamber treatment planning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor laboratories evaluating 180°C dry heat against their approved equipment-care procedure. No cycle duration or sterility validation is inferred.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eStacked-capacity planning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003ePlan modules, utilities, floor loading and service access together. A stack photograph is not a complete system bill of materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eFrom selection to a defined order\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003e1 · Match the process\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConfirm incubation conditions, orbit, speed and the appropriate separate treatment method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003e2 · Define the supplied system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConfirm module quantity, voltage, compatible holders, HEPA selection and all supplied components.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#FFF4E6;border:1px solid #E9CDA8;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003e3 · Plan delivery and support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAgree freight, unloading, installation, training and service responsibilities before purchase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003ePlanning tip:\u003c\/strong\u003e Keep incubation temperature, heat-treatment temperature and room operating conditions separate when comparing instruments. None replaces the current manufacturer operating procedure.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 24px;border-bottom:1px solid #E9CDA8;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#8A490B;margin:0 0 18px;\"\u003eOther laboratory workflows\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;border:1px solid #E9CDA8;border-radius:8px;padding:18px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eAlternative format\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/products\/major-science-orbital-shaker-ms-nor-30-ms-nor-3001?variant=50042155139370\" style=\"color:#8A490B;font-weight:600;text-decoration:underline;\"\u003eMS-NOR-3001 orbital shaker\u003c\/a\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSeparate orbital equipment, not an integrated CO₂ incubator or a like-for-like replacement. Review its own environmental and loading limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;border:1px solid #E9CDA8;border-radius:8px;padding:18px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#8A490B;\"\u003e\u003cstrong\u003eRelated workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/products\/major-science-digital-peristaltic-pump-mu-d?variant=50042105692458\" style=\"color:#8A490B;font-weight:600;text-decoration:underline;\"\u003eMU-D01 digital peristaltic pump\u003c\/a\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIndependent liquid-transfer workflow. Tubing and flow selection are separate; no integrated control or physical compatibility is implied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; line-height:1.15; box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eSI-970 buyer questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow is SI-970 different from SI-950?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eSI-970 uses the manufacturer-listed 180°C dry heat treatment; SI-950 lists 90°C moist heat. Both are non-refrigerated CO₂ models with a 50 mm orbit, 10 to 180 rpm shaking, ambient-to-60°C incubation and no UV lamp. Choose the heat method around the approved cleaning procedure, not an assumed increase in incubation temperature.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan SI-970 cool below room temperature?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. SI-970 is non-refrigerated and its incubation range is ambient to 60°C at 23 to 26°C ambient. For refrigeration with CO₂ control, compare SI-960, specified at 4 to 60°C at 23 to 25°C ambient. SI-910 is also refrigerated but has a 25 mm orbit, a 300 rpm maximum and no CO₂ control in the current specification.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the 180°C function mean I can incubate at 180°C?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. 180°C is the listed dry heat treatment temperature, not the incubation range. The public specification does not establish a treatment duration, permitted load or validated sterility outcome. Use the manufacturer's model-specific procedure and keep incubation settings within the stated ambient-to-60°C range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat atmosphere controls are specified, and is HEPA included?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eCO₂ control is 0.1 to 20% with an infrared sensor, ±0.1% accuracy and ±0.5% stability. Relative humidity is specified from 50 to 95% RH. HEPA filtration is optional, not standard. Confirm the gas and water requirements and any supporting hardware for the selected configuration.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow many flasks can I run at once?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe manufacturer lists alternative family maximums of 50 × 250 mL, 32 × 500 mL, 18 × 1000 mL or 15 × 2000 mL on the 91 × 50 cm platform. These are not included quantities or a guarantee for every flask design. Confirm vessel dimensions, holder compatibility and the permitted speed for your load.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the order include the pictured stack, holders and labware?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe photographs illustrate the family in single-module and stacked arrangements. Public specifications do not establish the supplied module count, holders, labware or complete accessory package. Confirm the order contents explicitly; the illustrated three-module stack is not a statement of what is included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat should I check before installation?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003ePlan for a 20 to 27°C operating ambient and single-phase 110 V or 220 V, 50\/60 Hz power. Confirm voltage, final electrical requirements, installation dimensions, stacking hardware, floor loading and service clearances for the actual arrangement. The specified 800 W is heater power, not total input power.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan I program a run from the touchscreen?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe 10-inch capacitive touchscreen supports PID control and a manually editable program. A timer of 9999 minutes or 9999 hours is listed. The current specification does not establish a program-step count or heat-cycle duration, so confirm those details against the operating procedure rather than treating the timer limit as a cycle recipe.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Major Science","offers":[{"title":"Default Title","offer_id":53246519116074,"sku":"BTS-SI-970","price":47003.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-950-si-970-single-module-family.webp?v=1792943710","url":"https:\/\/bluetigerscientific.com\/products\/major-science-winpact-si-970-co2-incubator-shaker-dry-heat","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}