{"product_id":"major-science-winpact-si-960-co2-refrigerated-stackable-incubator-shaker","title":"Winpact SI-960 CO2 Stackable Incubator Shaker","description":"\u003cdiv id=\"bts-major-si-960\" style=\"width:100%;max-width:1400px;margin:0 auto;padding:16px clamp(0px,1vw,12px);box-sizing:border-box;background:#fff;color:#26332C;font-family:'Open Sans',sans-serif;font-size:1rem;font-weight:300;line-height:1.75;\"\u003e\n\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;font-size:.85rem;letter-spacing:.06em;\"\u003e\u003cstrong\u003eMAJOR SCIENCE · WINPACT · SI-960\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eCO₂-controlled incubation in a stackable format\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe Winpact SI-960 brings refrigerated incubation, orbital shaking and CO₂ control together for workflows that need a defined chamber atmosphere. Its 50 mm orbit and 10 to 180 rpm shaking range distinguish it from the faster, non-CO₂ SI-910.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA 10-inch capacitive touchscreen, slide-out SUS316L platform and glide-up door support day-to-day setup. Choose the module arrangement and labware configuration around your process, rather than treating the illustrated stack as a supplied package.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:620px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-single-module-family.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-single-module-family.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-single-module-family.webp?v=1792864030\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-single-module-family.webp?v=1792864030\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-single-module-family.webp?v=1792864030\u0026amp;width=1400 1400w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 620px\" width=\"1450\" height=\"767\" alt=\"Winpact SI-910 and SI-960 family reference showing a single incubator-shaker module; final configuration and pictured labware require confirmation\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer family reference showing a single-module arrangement. Final module count and accessories are defined for the order; labware shown is illustrative.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e50 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eOrbit diameter\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e180 rpm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMaximum specified speed\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e4 to 60°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAt 23 to 25°C ambient\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e0.1 to 20%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eCO₂ control range\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWhy laboratories choose this format\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eAccess the working area\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA slide-out platform, glide-up door and chamber illumination support loading and visual checks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eControl the run\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA 10-inch capacitive touchscreen brings PID temperature control, a manually editable program and timer settings together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eChoose the right atmosphere\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSpecify SI-960 for its stated CO₂ and humidity capabilities. HEPA remains an optional selection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWhich Winpact shaking format do I need?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eSI-910\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eRefrigerated, non-CO₂ format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e25 mm orbit; 10–300 rpm; 4–60°C at 23–25°C ambient. No CO₂ or humidity control specified.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;padding:20px;border:2px solid #245B45;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eSI-960 · Current model\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eRefrigerated CO₂ format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e50 mm orbit; 10–180 rpm; 4–60°C at 23–25°C ambient. 0.1–20% CO₂; 50–95% RH; HEPA optional.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eWP-COS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eShaker for an existing incubator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e20 mm orbit; 1–300 rpm; 300 × 300 mm platform. Requires a suitable host incubator for environmental control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;font-size:.88rem;\"\u003eThese are different instrument formats, not interchangeable configurations or upgrade promises. Select the complete system around the conditions your protocol requires.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eMatch the chamber atmosphere to the workflow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSI-960 specifies CO₂ control from 0.1 to 20% with an infrared sensor, ±0.1% CO₂ accuracy and ±0.5% CO₂ stability. Its relative humidity specification is 50 to 95% RH.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eHEPA filtration is optional, not standard. Confirm the gas supply, regulator, connections and water-service requirements when defining the installation. These supporting services and accessories should not be inferred from the product photograph.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:620px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-family-chamber-detail.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-family-chamber-detail.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-family-chamber-detail.webp?v=1792864030\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-family-chamber-detail.webp?v=1792864030\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-family-chamber-detail.webp?v=1792864030\u0026amp;width=1000 1000w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 620px\" width=\"1000\" height=\"415\" alt=\"Detail of the Winpact incubator-shaker family chamber and illustrative flask arrangement; flask and holder counts are not supplied quantities\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer family chamber detail. The listed layouts are alternative maximums, not supplied flasks or holders.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003ePlan the load, not just the flask count\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe 91 × 50 cm slide-out platform gives you access to the working area without reaching to the back of the chamber. A glide-up door and internal illumination support routine loading and visual checks.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eManufacturer family capacity examples are 50 × 250 mL, 32 × 500 mL, 18 × 1000 mL or 15 × 2000 mL. These are alternative maximum layouts. Flask shape, retaining hardware and operating speed need to be checked together; the figures are not an included accessory list.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #e0e0e0; table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background: #f5f5f5; text-align: left; padding: 12px; font-weight: 700;width:50%;\"\u003eNominal flask size\u003c\/th\u003e\n\u003cth style=\"background: #f5f5f5; text-align: left; padding: 12px; font-weight: 700;width:50%;\"\u003eAlternative family maximum\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e250 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e50 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e500 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e32 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e1000 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e18 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003e2000 mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e15 flasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eSet the run from a 10-inch touchscreen\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe capacitive LCD touchscreen works with PID control, a manually editable program and a timer specified to 9999 minutes or 9999 hours. Servo-driven shaking and forced internal air circulation are shared features of the platform.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTemperature uniformity is specified as ±0.5°C at 37°C. The 4–60°C control range is stated at 23–25°C ambient; do not treat the broader operating ambient range as the test condition.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:520px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-orbit-selection-guide.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-orbit-selection-guide.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-orbit-selection-guide.webp?v=1792864030\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-orbit-selection-guide.webp?v=1792864030\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-orbit-selection-guide.webp?v=1792864030\u0026amp;width=1200 1200w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 520px\" width=\"1200\" height=\"1160\" alt=\"Blue Tiger Scientific specification schematic comparing SI-910 25 mm orbit and 10–300 rpm with SI-960 50 mm orbit and 10–180 rpm\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eBlue Tiger Scientific specification comparison, schematic only. The facts are also stated in HTML and the specifications tab.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) clamp(12px,3vw,20px);margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:clamp(14px,3vw,24px);\"\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:440px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-three-module-stack.webp?v=1792864030\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-three-module-stack.webp?v=1792864030\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-three-module-stack.webp?v=1792864030\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-three-module-stack.webp?v=1792864030\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-three-module-stack.webp?v=1792864030\u0026amp;width=1200 1200w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 440px\" width=\"1200\" height=\"1200\" alt=\"Manufacturer Winpact stackable incubator-shaker family illustration with three modules; not a statement of supplied unit count\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer three-module installation illustration. A pictured stack is not a supplied module quantity or an approved installation drawing.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eDefine the configuration before installation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose the module count and labware arrangement around your workload and available space. Manufacturer photographs show possible configurations, not a promise that a pictured stack, its holders or labware is included. Your confirmed quotation must identify the supplied modules and accessories.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSpecify 110 V or 220 V single-phase power and review the final stack arrangement, support hardware, floor loading and service clearances. The manufacturer lists 50\/60 Hz and 1800 W for these refrigerated models. Confirm the electrical connection for each module rather than assuming a complete stack uses one supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eUnderstand the UV function\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSI-960 includes a UV germicidal lamp in the manufacturer specification. It is not the 90°C moist-heat or 180°C dry-heat model in this family. Use the manufacturer’s operating and cleaning procedure, and do not treat the listed UV feature as a validated sterility claim.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eTypical application fit\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eControlled-atmosphere culture\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor workflows that specify CO₂ control together with refrigerated orbital shaking.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eHumidity-sensitive workflows\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eEvaluate the specified 50–95% RH range against your protocol and required site services.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eMulti-module planning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eDefine module count, culture vessels and utilities together for a planned stacked installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eA better starting point for your quotation\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e1 · Define the process\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSpecify the temperature, orbit, speed, atmosphere and vessel geometry required by your existing protocol.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e2 · Define the configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAgree module count, holders, optional filtration and the actual supplied components.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:clamp(12px,3vw,20px);\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e3 · Define the installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConfirm the current installation drawing, voltage, services, floor loading, freight and support responsibilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003ePlanning tip:\u003c\/strong\u003e Maximum flask count is not a guarantee of working culture volume or full-speed operation with every vessel layout. Verify the actual loaded configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:clamp(16px,4vw,24px) 0px;margin:0 0 clamp(16px,4vw,24px);border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eOther laboratory workflows\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;padding:18px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eAlternative format\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/products\/major-science-orbital-shaker-ms-nor-30-ms-nor-3001?variant=50042155139370\" style=\"color:#245B45;font-weight:600;text-decoration:underline;\"\u003eMS-NOR-3001 anti-moisture orbital shaker\u003c\/a\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA different orbital format for a separately defined bench or chamber workflow. Review its lower published speed range and different load rating; it is not an integrated incubator or a like-for-like replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;padding:18px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eRelated workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/products\/major-science-digital-peristaltic-pump-mu-d?variant=50042105692458\" style=\"color:#245B45;font-weight:600;text-decoration:underline;\"\u003eMU-D01 digital peristaltic pump\u003c\/a\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eExplore a separate liquid-transfer step. Tubing and flow requirements are selected independently; no mechanical, electrical or automated integration with this shaker is implied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; line-height:1.15; box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eSI-960 buyer questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat distinguishes SI-960 from SI-910?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eSI-960 combines a 50 mm orbit and 10 to 180 rpm shaking with CO₂ control and a specified humidity range. SI-910 uses a 25 mm orbit and 10 to 300 rpm shaking without those atmosphere-control features. Both are refrigerated models with a UV germicidal lamp.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat CO₂ and humidity specifications are listed?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eCO₂ control is specified from 0.1 to 20% using an infrared sensor, with ±0.1% accuracy and ±0.5% stability. Relative humidity is specified from 50 to 95% RH. Confirm the gas supply, regulator, connection and water-service requirements for the selected configuration; these service accessories are not established as included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs SI-960 refrigerated, and what is its temperature range?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. Current manufacturer information specifies 4 to 60°C at 23 to 25°C ambient, with temperature uniformity of ±0.5°C at 37°C. SI-960 should not be confused with the ambient-to-60°C SI-950 and SI-970 models.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow many flasks will fit?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe family maximums are 50 × 250 mL, 32 × 500 mL, 18 × 1000 mL or 15 × 2000 mL. These are alternative layouts, not included quantities. Confirm flask dimensions, holder compatibility and the permitted speed for the planned load.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs the illustrated stack and its labware included?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eTreat the single-module and three-module photographs as installation examples, not a bundle promise. The supplied module count, platforms, holders and labware must be identified on the confirmed quotation. A photograph alone does not define the package.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat should be checked before stacking and installation?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe manufacturer presents single-, double- and triple-layer arrangements. Confirm the final assembly, support hardware, floor loading, clearances, ventilation and CO₂ services before installation. Electrical options are single-phase 110 V or 220 V, 50\/60 Hz, with a listed 1800 W rating; verify each module’s supply and circuit requirements.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs HEPA filtration standard on SI-960?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. HEPA is listed as optional. Request it when defining the configuration and confirm the supplied filter arrangement. The CO₂ sensor and humidity specification do not themselves establish HEPA inclusion.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes SI-960 use UV or heat sterilization?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eSI-960 is listed with a UV germicidal lamp and UV sterilization. The 90°C moist-heat and 180°C dry-heat methods belong to SI-950 and SI-970, respectively. Follow the manufacturer’s operating and cleaning instructions; do not treat the UV feature as a validated sterility guarantee.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Major Science","offers":[{"title":"Default Title","offer_id":53217549353258,"sku":"BTS-SI-960","price":28067.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-winpact-si-910-si-960-single-module-family.webp?v=1792864030","url":"https:\/\/bluetigerscientific.com\/products\/major-science-winpact-si-960-co2-refrigerated-stackable-incubator-shaker","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}