{"product_id":"ika-t-25-digital-ultra-turrax-disperser-drive","title":"IKA T 25 digital ULTRA-TURRAX Disperser, 100–120 V, Drive Only","description":"\u003cdiv id=\"bts-ika-t25\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:24px;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;color:#245B45;letter-spacing:.07em;\"\u003eIKA T 25 DIGITAL ULTRA-TURRAX • 0003725001 • US 100–120 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);line-height:1.15;color:#13314E;font-weight:600;\"\u003eHigh-shear preparation starts with the right drive. Results depend on the right tool.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eTurn a nonuniform liquid sample into a workable research preparation with rotor-stator dispersion. The classic IKA T 25 digital ULTRA-TURRAX gives you an LED speed readout, stepless adjustment from 3,000 to 25,000 rpm and electronic speed control for batch homogenizing, emulsifying and dispersing.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eThis listing is for the drive only.\u003c\/strong\u003e Choose a compatible dispersing tool, stand, clamp and suitable vessel separately. The guide below explains three reusable tool choices so you do not mistake a broad 1–2,000 mL water-based range for the working range of one universal shaft.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507 1200w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1200\" height=\"1200\" alt=\"IKA T 25 digital ULTRA-TURRAX classic drive with a separately sold dispersing tool shown in the manufacturer photograph\" style=\"width:100%;max-width:420px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer photograph. The fitted dispersing tool shown is not included. This order is the T 25 digital drive, not a complete stand-and-tool system.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e3,000–25,000 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eStepless speed adjustment\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1–2,000 mL\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eH₂O range across suitable tools\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e800 W \/ 500 W\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eMotor input \/ output rating\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e100–120 V\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003e50\/60 Hz US configuration\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat are you buying, and what completes the setup?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIncluded: the drive\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eOne IKA T 25 digital ULTRA-TURRAX, catalog 0003725001. The manual also lists its extension arm, hexagon socket screw, DIN 911 screwdriver and operating instructions. This is not a preconfigured stand-and-tool kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose separately: the tool\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA compatible S 25 dispersing tool is required. Choose its water-based working range, head diameter, immersion requirements, seal and wetted materials for your method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose separately: support\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse suitable support and vessel restraint for the setup. IKA lists stands, a boss-head clamp and a strap clamp as accessories. They are not included in this drive-only order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhere the T 25 digital earns its place\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eLiquid sample homogenization\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA fit for research preparations that need intensive local shear rather than simple bulk circulation. Tool selection and the starting sample determine the achievable result.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eEmulsions and dispersions\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse an appropriate rotor-stator element to work on liquid-liquid emulsions or solid-liquid dispersions. Confirm chemistry and process limits instead of selecting by RPM alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eEnvironmental and formulation research\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA identifies wastewater homogenization and laboratory-research dispersion among the applications. Develop a suitable method for sample volume, viscosity, heat sensitivity and the selected tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHow the tool creates high shear\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789 1200w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1200\" height=\"1000\" alt=\"Simplified rotor-stator principle: sample enters axially and exits radially through the stator slots while the rotor turns inside\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal explanatory schematic based on the manufacturer’s rotor-stator description. Not an exact-tool cutaway or dimensional drawing.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe motor turns the rotor inside a stationary stator. Sample is drawn axially into the head, then forced radially through the rotor-stator arrangement. Strong shear develops in the narrow working gap.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThat is why a disperser is not interchangeable with a magnetic stirrer. A stirrer is often appropriate for dissolving or bulk mixing; a rotor-stator disperser is chosen when the preparation calls for intensive shear, dispersion or emulsification.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eIntake: sample enters along the tool axis.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eProcessing: the rotating rotor works inside the fixed stator.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eOutflow: processed liquid exits radially and recirculates in the vessel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSpeed, head design, solids, sample volume and processing time work together. A high RPM value alone does not establish the final particle or droplet size.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhich dispersing tool do I need?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThese are three manufacturer-listed reusable S 25 N options for the classic T 25 digital. They are not included, are not interchangeable at every volume, and are not selectable purchase variants of this drive listing. Water-based ranges are starting points, not universal guarantees for every sample.\u003c\/p\u003e\n\u003cdiv style=\"border:1px solid #B7D0BF;border-radius:8px;padding:20px;margin:0 0 18px;box-sizing:border-box;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"600\" alt=\"S 25 N - 8 G dispersing head, catalog 0001024200, optional tool sold separately\" style=\"width:100%;max-width:480px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer close-up: S 25 N - 8 G. Optional tool, not included with the drive.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eS 25 N - 8 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCatalog 0001024200\u003c\/strong\u003e\u003cbr\u003eWorking volume: 1–50 mL H₂O\u003cbr\u003eStator diameter: 8 mm\u003cbr\u003eImmersion depth: 27–85 mm\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eSmall-volume preparations.\u003c\/strong\u003e A useful starting point when your water-like sample volume is small and the vessel allows the specified immersion. Do not substitute the larger 25 mm head just because the drive is rated up to 2 L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #B7D0BF;border-radius:8px;padding:20px;margin:0 0 18px;box-sizing:border-box;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"600\" alt=\"S 25 N - 18 G dispersing head, catalog 0000593400, optional tool sold separately\" style=\"width:100%;max-width:480px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer close-up: S 25 N - 18 G. Optional tool, not included with the drive.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eS 25 N - 18 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCatalog 0000593400\u003c\/strong\u003e\u003cbr\u003eWorking volume: 10–1,500 mL H₂O\u003cbr\u003eStator diameter: 18 mm\u003cbr\u003eImmersion depth: 40–165 mm\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eA broad middle range.\u003c\/strong\u003e Consider this middle-size tool when its range, immersion and vessel geometry match your method. The overlapping volume range with other heads does not make their performance identical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #B7D0BF;border-radius:8px;padding:20px;margin:0 0 18px;box-sizing:border-box;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"600\" alt=\"S 25 N - 25 G dispersing head, catalog 0001713300, optional tool sold separately\" style=\"width:100%;max-width:480px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer close-up: S 25 N - 25 G. Optional tool, not included with the drive.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eS 25 N - 25 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCatalog 0001713300\u003c\/strong\u003e\u003cbr\u003eWorking volume: 50–2,000 mL H₂O\u003cbr\u003eStator diameter: 25 mm\u003cbr\u003eImmersion depth: 40–165 mm\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eLarger research batches.\u003c\/strong\u003e This example reaches the drive family’s 2 L water-based upper range. Check the sample depth, clearance, viscosity and required circulation rather than choosing solely by vessel capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe immersion values above are published tool specifications, not a universal startup instruction. Follow the drive and tool manuals together. For operation near a tool’s lower published immersion limit, have IKA confirm your vessel and fill geometry before use. Maintain at least 10 mm between the tool and vessel bottom, as required by the drive manual.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAll three examples list AISI 316L stainless steel and PTFE as medium-contact materials. Their N-type construction is not rated for vacuum operation. A vacuum or pressure process requires a specifically suitable sealed tool and complete system, not just a different speed setting.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFibrous material?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eEvaluate the separately listed saw-tooth ST tools for cutting and tearing fibrous material. Do not assume the ordinary G examples shown above have the same geometry or suitability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFine emulsions or closed systems?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFine F tools and sealed KV\/KD designs have different application limits. Review the exact element data with IKA before choosing a tool for a specific fineness, vacuum or pressure requirement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBuild a supported, restrained setup\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"1000\" alt=\"IKA R 1825 plate stand, catalog 0003160000, optional support not included\" style=\"width:100%;max-width:360px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eR 1825 plate stand, catalog 0003160000. Optional, not included. Manufacturer photograph with surrounding white space normalized.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSupport the drive and secure the vessel\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive’s extension arm is 13 mm in diameter and 160 mm long. IKA’s accessory selection includes the R 1825 plate stand, the R 182 boss-head clamp and the RH 3 strap clamp. Confirm the complete mounting arrangement for your vessel and tool before ordering.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis instrument is for stand-mounted operation, not handheld use. The R 1825 stand supports the assembly; the R 182 boss-head clamp accommodates its 16 mm rod and the drive’s 13 mm arm. The RH 3 is a separate vessel-restraint accessory. The manual requires glass vessels to be secured, and at least 10 mm of clearance between the tool and vessel bottom.\u003c\/p\u003e\n\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"462\" alt=\"IKA R 182 boss-head clamp, catalog 0002657700, optional accessory\" style=\"width:100%;max-width:440px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eR 182 boss-head clamp, catalog 0002657700. Optional, not included. RH 3 strap clamp, catalog 0003008600, is a separate vessel-restraint choice.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical workflow for repeatable preparation\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e1 • Match the method\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDefine sample volume, viscosity, solids, materials compatibility and temperature sensitivity. Select the shaft and vessel as a pair, using the tool’s immersion limits rather than the drive’s overall capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e2 • Assemble with power isolated\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFollow the instrument and selected tool instructions for mounting and installation. Check that the tool is secured, the support is stable and the vessel cannot rotate or move.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e3 • Use short, controlled runs\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003ePlace the tool correctly in the liquid before operating. Start at the lowest speed and increase as needed without splashing. The three S 25 N tool manuals limit a run to one minute; seconds may be sufficient. Record tool, volume, RPM and time for repeatability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e4 • Stop, cool and clean\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eHigh shear introduces heat. Monitor temperature-sensitive preparations and stop when the method requires. Switch off and disconnect power before disassembly or cleaning, then follow the tool-specific cleaning instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAvoid the three most common selection mistakes\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eDrive duty is not tool run time.\u003c\/strong\u003e The drive is rated for 100% ON time, but the S 25 N tools shown here are not intended for continuous operation. Their manuals specify a maximum one-minute run. Do not use the motor’s duty rating to justify a longer tool run.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDo not run the dispersing tool dry. The circulation opening must remain in the medium, with the specified immersion maintained.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDo not confuse the drive’s 5–40 °C ambient rating with a tool’s medium-temperature limit. Chemistry, seals, vessel and tool all have their own limits.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDo not keep extending run time to chase a guaranteed fineness. Temperature rise, air entrainment and tool wear may become the limiting factors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse only within the instrument and tool manuals. This page is for research laboratory use, not clinical or diagnostic use. Do not use this drive in explosive atmospheres.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eClassic T 25 digital or an EASY CLEAN model?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThis page: classic T 25 digital\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCatalog 0003725001. LED speed display, 3,000–25,000 rpm and 800 W input \/ 500 W output. Choose a separately supplied, compatible S 25 tool. This is the established classic drive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eEASY CLEAN digital \/ control\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThese are separate instruments. Do not transfer their brushless-motor, cleaning, interface or temperature-sensing claims to this classic model. If your workflow needs those functions, request an exact-model comparison before buying.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRelated equipment for the preparation bench\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-c-mag-hs-7-digital-magnetic-hotplate-stirrer\" style=\"color:#245B45;font-weight:600;\"\u003eIKA C-MAG HS 7 digital hotplate stirrer\u003c\/a\u003e supports heated magnetic mixing in a separate workflow. It does not replace the T 25’s high-shear action and is not offered here as a compatible disperser support.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/heathrow-scientific-glass-beakers-durable-borosilicate-lab-beakers\" style=\"color:#245B45;font-weight:600;\"\u003eHeathrow borosilicate glass beakers\u003c\/a\u003e provide vessel options to review. Check the chosen vessel’s internal dimensions, condition and method suitability; no blanket fit with every S 25 tool is implied.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:40px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:20px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included with T 25 digital ULTRA-TURRAX 0003725001?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThis listing supplies the classic T 25 digital drive in the US 100–120 V configuration. The dispersing tool is not included. Stands, clamps, vessel restraints and vessels must be selected separately; this is not a complete stand-and-tool kit.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhich tool lets the T 25 work with small sample volumes?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA lists the S 25 N - 8 G, catalog 0001024200, for 1–50 mL of water-based sample. Its stator diameter is 8 mm and specified immersion depth is 27–85 mm. The actual sample and vessel must allow suitable immersion and circulation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan a single shaft process the entire 1–2000 mL range?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The drive’s range covers suitable different tools. Examples are S 25 N - 8 G 0001024200 for 1–50 mL, S 25 N - 18 G 0000593400 for 10–1500 mL and S 25 N - 25 G 0001713300 for 50–2000 mL, all specified for H₂O.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan this setup run continuously because the drive is rated 100% ON time?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Drive duty and tool run time are separate limits. The manuals for S 25 N - 8 G, -18 G and -25 G specify non-continuous operation and a maximum one-minute run. Follow the more restrictive tool and sample limits, even though the motor’s permissible ON time is 100%.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs the classic T 25 digital the same as T 25 EASY CLEAN?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. They are different IKA instruments. This page is for classic catalog 0003725001. Do not assume EASY CLEAN brushless, interface, cleaning or temperature-sensing features are included. Tool compatibility must be checked for the exact drive and element.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan the S 25 N tools shown here run under vacuum?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. IKA marks the S 25 N - 8 G, -18 G and -25 G examples as unsuitable for vacuum operation. A vacuum or pressure method requires an appropriately rated sealed tool, vessel and complete setup. The drive alone does not establish a system pressure rating.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan the tool run dry or touch the vessel bottom?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eDo not run the dispersing tool dry. Keep the circulation opening and the required length of the tool immersed, and keep the head clear of the vessel wall and bottom. Switch off before removing the tool from the liquid or changing the setup, following the manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow do I prevent heating and cross-contamination between samples?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eHigh-shear processing adds heat, so monitor temperature and develop a suitable speed and run time for the sample. Clean reusable tools according to their instructions and your laboratory procedure. Separately selected disposable tools are single-use, not a reason to promise zero contamination in every workflow.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53396356563242,"sku":"BTS-0003725001","price":3010.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507","url":"https:\/\/bluetigerscientific.com\/products\/ika-t-25-digital-ultra-turrax-disperser-drive","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}