{"product_id":"ika-rc-2-green-control-recirculating-chiller-115v-0025007404","title":"IKA RC 2 GREEN control Recirculating Chiller, 115 V","description":"\u003cdiv id=\"bts-ika-rc2-green\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:20px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.04em;color:#245B45;\"\u003eIKA RC 2 GREEN CONTROL • 0025007404 • US 115 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eA dedicated cooling loop with the controls to match your method.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRemove heat from a suitable external circuit with the \u003cstrong\u003eIKA RC 2 GREEN control\u003c\/strong\u003e. This compact recirculating chiller combines a \u003cstrong\u003espeed-controlled compressor\u003c\/strong\u003e, adjustable PEEK pressure\/suction pump and removable \u003cstrong\u003eWiCo controller\u003c\/strong\u003e. The \u003cstrong\u003ePT 100.30 external temperature sensor is included\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eExact US order \u003cstrong\u003e0025007404\u003c\/strong\u003e is the \u003cstrong\u003e115 V, 50\/60 Hz\u003c\/strong\u003e version. Its working range is \u003cstrong\u003e−30°C to room temperature\u003c\/strong\u003e, with \u003cstrong\u003e800 W cooling at +20°C\u003c\/strong\u003e and less capacity at colder targets. It is a cooling-only instrument, not a heating\/cooling circulator.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eSpecify the complete loop.\u003c\/strong\u003e Connecting hoses, coolant, any additional fittings and the external application equipment are separate selections. Supplied hose olives are not a complete connection kit or proof that every reactor, condenser or shaker setup is ready to run.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Genuine manufacturer photograph of RC 2 GREEN control recirculating chiller with WiCo\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-system.webp?v=1793908990\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-system.webp?v=1793908990\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-system.webp?v=1793908990\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-system.webp?v=1793908990 1000w\" style=\"width:100%;max-width:620px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer photograph. Displayed cold setpoints are illustrative chiller settings, not recommended KS 4000 ic inlet settings. External equipment, connecting hoses and coolant are not included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e800 W at +20°C\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eCooling reference, not at every temperature\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e−30°C to ambient\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eCooling-only working range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003ePT 100.30\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eExternal sensor included\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003eWiCo control\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eLocal operation without a required PC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIs RC 2 GREEN control right for your application?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYou need to remove heat\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose a recirculating chiller when the job is cooling a compatible external circuit. If the method also requires active heating, select a separately specified heating\/cooling system instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYou can size at the actual target\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse the cooling-capacity reference at your target temperature and account for process heat, ambient gain, tubing and pull-down requirements. The lowest setpoint does not carry the highest cooling power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYou have a defined hydraulic circuit\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eMatch pressure, flow resistance, materials, hose sizes and fluid limits across the complete loop. An adjustable pump does not make every external device compatible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYou want local controls and process feedback\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eWiCo supports local settings, timer\/counter functions and programs. The included external sensor can support an appropriately configured external-control method; its presence does not validate that method automatically.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat is included in US order 0025007404?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Manufacturer photograph of PT 100.30 temperature sensor, part 0004284700\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-probe.webp?v=1793908990\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-probe.webp?v=1793908990\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-probe.webp?v=1793908990\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-probe.webp?v=1793908990 1000w\" style=\"width:100%;max-width:560px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003ePT 100.30 is explicitly included in the current RC 2 GREEN control delivery list. Its component temperature rating does not extend the chiller’s operating limits.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChiller, WiCo, external sensor and listed connection hardware\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eRC 2 GREEN control with WiCo wireless controller.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eTwo DN 8 hose olives and two DN 12 hose olives.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUSB-A to Micro-B cable, 2 m.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003ePT 100.30 temperature sensor.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eWiCo charger.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe operating manual also identifies power cables, WH 10 WiCo holder, OS 1.0 power supply, an additional USB lead, connector caps and documentation. Where a specific regional packing detail matters, confirm the current order configuration rather than treating an interface as proof that every cable or fitting is supplied.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eSeparate selections:\u003c\/strong\u003e connecting hoses and clamps, suitable coolant, any additional adapters or pressure safeguards, the external process device and an optional software license. DN 10 olives are a manufacturer-listed option, not an extra pair included with the supplied DN 8\/DN 12 hardware.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCooling capacity changes with the target temperature\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Cooling reference at 4000 rpm: 800 W at 20, 700 W at 10, 500 W at zero, 400 W at minus 10, 200 W at minus 20 and 90 W at minus 30 degrees Celsius\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-capacity.webp?v=1793908990\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-capacity.webp?v=1793908990\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-capacity.webp?v=1793908990\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-capacity.webp?v=1793908990 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal guide based on manufacturer DIN 12876 data at 4,000 rpm. These reference capacities are not guaranteed process cooling rates.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSize the duty, not just the minimum setpoint\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe current reference values are \u003cstrong\u003e800 W at +20°C, 700 W at +10°C, 500 W at 0°C, 400 W at −10°C, 200 W at −20°C and 90 W at −30°C\u003c\/strong\u003e. A heat-generating process at a low target may need more cooling capacity even when its setpoint lies within the chiller’s stated range.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eInclude external heat input, ambient conditions, tubing losses and required time to target. The 1.4–4.0 L bath-fill range is internal thermofluid volume, not a universal sample-capacity rating.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA describes up to 2.5 L available for the external circuit without refilling. Treat that as a fluid-management reference, not proof that any 2.5 L process will reach the target or that a larger sample is automatically unsuitable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSelect the pump operating point and the actual fittings\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMaximum flow and maximum pressure are different limits\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe speed-controlled PEEK pressure\/suction pump adjusts from 2,000 to 4,000 rpm. Its \u003cstrong\u003e21 L\/min maximum flow is at zero back pressure\u003c\/strong\u003e; the \u003cstrong\u003e0.5 bar maximum pressure is at zero discharge flow\u003c\/strong\u003e. The suction reference is 0.25 bar at zero flow. Do not combine those maxima into one performance promise.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eConnections are M16×1. The supplied DN 8 and DN 12 hose olives need matching, temperature-rated hoses and secure clamps. Select the operating point from the actual circuit resistance and the manufacturer’s pump curve, while respecting the connected device’s pressure limit.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor a 10 mm-ID connection route, the manufacturer lists \u003cstrong\u003eDN 10 hose olives \/ 0020004568\u003c\/strong\u003e as an optional two-piece adapter set. It is not included here and is not, by itself, a complete KS 4000 ic installation. Review both ends of the loop, hose material, clamps, pressure protection and thermal duty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-circuit_phone.webp?v=1793908993\" width=\"720\"\u003e\u003cimg alt=\"Hydraulic planning guide distinguishing maximum flow and pressure, supplied DN8\/DN12 olives and the KS 4000 ic 10 mm connection requirement\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-circuit.webp?v=1793908990\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-circuit.webp?v=1793908990\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-circuit.webp?v=1793908990\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-circuit.webp?v=1793908990 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal selection guide. Not a piping drawing or confirmation of a complete adapter\/hosing configuration.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWiCo control and an included external temperature probe\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Actual RC 2 GREEN control WiCo display and fluid-level detail from the manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-controls.webp?v=1793908990\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-controls.webp?v=1793908990\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-controls.webp?v=1793908990\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-controls.webp?v=1793908990 1000w\" style=\"width:100%;max-width:450px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eActual control-panel crop. Displayed negative temperatures are examples, not settings for a KS 4000 ic whose inlet must remain above 3°C.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eControl the cooling method, not just the display number\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eWiCo provides local operation, timer\/counter functions and ten temperature programs with up to ten steps each. Programs remain limited by this cooling-only system’s available duty; selecting a warmer setpoint does not add an active heater.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe PT 100.30 connects to the external PT 100\/LEMO interface for an appropriately configured external-control method. It is not the KS shaker’s PT 1000.60 sensor, and those sensor functions must not be interchanged by name alone.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual lists \u003cstrong\u003e±0.15 K internal temperature stability\u003c\/strong\u003e under DIN reference conditions and \u003cstrong\u003e±0.5 K internal\/external absolute measurement accuracy\u003c\/strong\u003e, adjustable by calibration. Display resolution of 0.01 K is not 0.01 K accuracy.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eWireless operation is building-dependent, up to 15 m per the manual. Review communication timeout, safe-speed and safe-temperature settings; loss of the WiCo link or battery is not a universal automatic shutdown. USB and RS-232 support separately configured software workflows; no software license or validated electronic-recordkeeping compliance is implied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA manufacturer-named cooling option for KS 4000 ic\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"KS 4000 ic shown as a separately sold external-cooling application\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width:600px) 100vw, 500px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182 1000w\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eKS 4000 ic is a separate instrument, not included with the chiller. Its holder and the complete cooling installation are also separate selections.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eKeep the shaker’s limits even when the chiller can go colder\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe current KS 4000 ic manual names RC 2 GREEN basic\/control as examples of external cooling units. That manufacturer relationship is useful, but it is not a guarantee that every load, hose arrangement or target temperature is already validated.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-ks-4000-ic-control-incubator-shaker-115v-0003510101?variant=53469664444714\" style=\"font-weight:600;color:#245B45;\"\u003eKS 4000 ic control with its separately specified cooling installation\u003c\/a\u003e. The shaker requires coolant inlet above 3°C, a maximum 1 bar circuit pressure, its 10 mm-ID connection route, the permitted water\/antifreeze coolant and condensate drainage under its manual.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not use this chiller’s −30°C lower limit as permission to send sub-zero coolant into the shaker. The shaker manual recommends pressure protection; this listing does not waive that recommendation based on a pump headline. Appropriate adapters, hoses, clamps, flow and heat-load sizing still need review.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe heating-only KS 4000 i has no ic cooling circuit. Adding a chiller does not convert that different model into an ic system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose the fluid and installation for the complete circuit\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003ePrepare the loop before commissioning\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDefine target temperature, process heat load and the external equipment’s limits.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSelect compatible fluid, hoses, adapters and safeguards for the coldest and warmest conditions.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUse the manual’s filling, venting, leak-check and level-control procedures; never run without sufficient fluid.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSet suitable control, program and communication-loss behavior, then verify the actual method under load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe fluid’s maximum stated viscosity is 50 mm²\/s at the lowest operating temperature. Ordinary water is not a suitable assumption for operation at −30°C. Connected equipment may impose stricter fluid and temperature requirements, as KS 4000 ic does.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual requires at least a 9 m³ room, adequate ventilation, 20 cm free space at front and rear, and at least one hour settling after positioning before operation. R290 is flammable; it is not an explosion-proof instrument. Keep the filter and ventilation paths accessible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-workflow_phone.webp?v=1793908993\" width=\"720\"\u003e\u003cimg alt=\"Cooling-loop workflow from thermal duty and fittings to fluid selection and manual commissioning\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-workflow.webp?v=1793908990\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-workflow.webp?v=1793908990\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-workflow.webp?v=1793908990\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-workflow.webp?v=1793908990 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal planning overview, not an installation procedure or substitute for the chiller and connected-equipment manuals.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRC cooling only or an active heating\/cooling system?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-selection_phone.webp?v=1793908993\" width=\"720\"\u003e\u003cimg alt=\"Selection guide comparing cooling-only RC 2 GREEN control with separately specified heating\/cooling equipment and stricter KS shaker limits\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-selection.webp?v=1793908990\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-selection.webp?v=1793908990\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-selection.webp?v=1793908990\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-selection.webp?v=1793908990 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal buyer guide. The chiller’s capabilities do not override the temperature, coolant or pressure limits of the connected application.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThis RC 2 GREEN control\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose it when the job is cooling and circulating fluid, with the actual target-duty and hydraulic limits checked. Its working range is −30°C to ambient.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eNeed active heating as well?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse an appropriately selected heating\/cooling circulator. The RC table’s 70°C maximum with external heating is a permitted externally heated operating limit, not a supplied heater or a 70°C heating function.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eNeed lower-temperature duty under load?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCompare capacity at the target, not just minimum temperature. A larger refrigeration system may be needed when the heat load or time-to-target exceeds this model’s actual capability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eAlternative format:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-hrc-2-green-control-heating-cooling-circulator-115v-0020128747?variant=53456197321002\" style=\"font-weight:600;color:#245B45;\"\u003eHRC 2 GREEN control for a separately specified heating-and-cooling workflow\u003c\/a\u003e. It is a different order with its own supplied scope and application limits, not an extra heater included here.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCare, warranty and delivery planning\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eInspect hoses, fittings and fluid condition, maintain the accessible front filter and follow the manual before draining or moving the unit. Isolate power for accessory changes or maintenance. Only the manufacturer should open or repair the sealed refrigeration circuit.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual states a 24-month baseline warranty with exclusions for wear, improper use and inadequate care. Any registration extension depends on current IKA exact-model terms; no unconditional period is promised for every accessory. Blue Tiger handles purchases and return requests; IKA handles manufacturer warranty assessment, technical support, calibration and repairs.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eShipping uses a documented 75 lb provisional RC-package allowance, not the 26.5 kg device mass as measured packed gross. Manufacturer availability, dispatch, actual cartons, carrier handling requirements and optional delivery services need order-specific confirmation. The store inventory setting is not a supplier warehouse-stock statement.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:22px;margin:24px 0;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;box-sizing:border-box;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSpecify the cooling duty and the connection route\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor \u003cstrong\u003eRC 2 GREEN control \/ US 115 V \/ 0025007404\u003c\/strong\u003e, tell Blue Tiger the target temperature, expected heat load, connected equipment, fluid, hose sizes\/lengths and pressure limits. We can coordinate current configuration and application questions with IKA.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIf the application is KS 4000 ic, name that shaker explicitly. Its inlet, fluid, pressure and drainage rules still apply, and neither a complete hose kit nor the shaker itself is supplied in this chiller order.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block;max-width:100%;padding:12px 16px;box-sizing:border-box;border-radius:6px;background:#245B45;color:white;text-decoration:none;font-size:1rem;font-weight:600;line-height:1.4;\"\u003eConfirm my cooling-loop requirements\u003c\/a\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:30px;padding-top:20px;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes US RC 2 GREEN control 0025007404 include the external sensor and hoses?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003ePT 100.30 is explicitly included, along with WiCo, charger, two DN 8 olives, two DN 12 olives and the listed USB-A to Micro-B cable. Connecting hoses, coolant and additional application fittings are separate selections. Hose olives are adapters, not a complete installation kit.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes it provide 800 W cooling at −30°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. DIN 12876 references at 4,000 rpm are 800 W at +20°C, 700 W at +10°C, 500 W at 0°C, 400 W at −10°C, 200 W at −20°C and 90 W at −30°C. Size the cooling system for the target-temperature duty and actual external heat load.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan RC 2 GREEN control actively heat a bath to 70°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIt is a cooling-only chiller with a −30°C to ambient working range. The 70°C maximum with external heating is not an included heater or active heating function. If the method needs both directions, choose a separately specified heating\/cooling circulator.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan its pump deliver 21 L\/min at 0.5 bar simultaneously?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo combined promise is made. The 21 L\/min maximum is at zero back pressure; 0.5 bar maximum pressure is at zero discharge flow. Use the actual circuit resistance and the pump curve, while respecting the connected device’s limits.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs this a manufacturer-named cooling option for KS 4000 ic?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes. The current KS 4000 ic manual names RC 2 GREEN basic\/control as external-cooling examples. The complete installation still needs review: shaker inlet above 3°C, maximum 1 bar, appropriate water\/antifreeze, matching 10 mm-ID connection route, pressure protection and condensate drain. This is not a turnkey shaker\/chiller bundle.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhich fittings do I need for a 10 mm hose route?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe chiller has M16×1 connections and supplies DN 8\/DN 12 olives. IKA lists optional DN 10 hose olives, catalog 0020004568, as a two-piece set. They are not supplied here, and a complete installation still needs correctly selected hoses, clamps, other fittings and safeguards. Do not assume every proposed adapter solves the full loop.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 0.01 K display mean 0.01 K accuracy?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The manual lists ±0.15 K internal stability under DIN reference conditions and ±0.5 K internal\/external absolute measurement accuracy, adjustable by calibration. Display resolution, stability, probe tolerance and actual method accuracy are different concepts.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDo I need a PC or an unlimited-range wireless connection?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eLocal operation does not require a PC. WiCo provides timer\/counter functions and ten temperature programs with up to ten steps each. The manual’s up-to-15 m wireless distance depends on the building. Review communication-loss and power-return settings; no universal shutdown, cloud connection, software license or unlimited wireless reach is promised.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53472112247082,"sku":"BTS-0025007404","price":6195.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-rc2-green-control-system.webp?v=1793908990","url":"https:\/\/bluetigerscientific.com\/products\/ika-rc-2-green-control-recirculating-chiller-115v-0025007404","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}