{"product_id":"ika-lr-1000-control-laboratory-reactor-system-115v-0025001992","title":"IKA LR 1000 control 1 L Laboratory Reactor System, 115 V","description":"\u003cdiv id=\"bts-ika-lr1000\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:20px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.04em;color:#245B45;\"\u003eIKA LR 1000 CONTROL SYSTEM • 0025001992 • US 115 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eTurn a beaker trial into a controlled formulation workflow.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBring \u003cstrong\u003eanchor mixing, heating, sample-temperature sensing and process visibility\u003c\/strong\u003e to one compact benchtop. The IKA LR 1000 control System is a 1 L laboratory reactor for developing suitable viscous formulations, including creams and lotions in cosmetic and pharmaceutical research.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUS catalog \u003cstrong\u003e0025001992\u003c\/strong\u003e supplies the Control base, \u003cstrong\u003eLR 1000.3 reactor vessel\u003c\/strong\u003e, anchor stirrer with PEEK scrapers and a PT 100.30 temperature sensor. Its TFT interface adds onboard weighing, relative torque-trend display and a connection for a separately selected pH electrode.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStart with a defined factory system, then add only the cooling, vacuum or high-shear equipment your method needs. Cooling, vacuum and high-shear equipment are separate selections, not items included with this order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"IKA LR 1000 control laboratory reactor, front view with supplied vessel and anchor-stirring assembly\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115 1000w\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer photograph. Display readings are illustrative. Order scope follows the supplied-parts checklist; optional external instruments are not included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1 L\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum useful volume\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e10–150 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eAnchor-stirring speed range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e100,000 mPa·s\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum published viscosity rating\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e120°C\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eMaximum working temperature of the medium\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection id=\"bts-lr1000-buyer-fit\" style=\"padding:24px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003cp style=\"font-size:.83rem;font-weight:600;letter-spacing:.04em;color:#245B45;margin:0 0 8px;\"\u003eA QUICK BUYING DECISION\u003c\/p\u003e\n\u003ch2 style=\"font-size:1.5rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 14px;\"\u003eIs this the right system for your lab?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 18px;\"\u003eThe strongest reason to choose LR 1000 control is a defined formulation workflow, not simply a higher-priced stirrer. Match the batch, process measurements and supplied equipment to the work you need to do.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eDevelop suitable creams, lotions and viscous blends\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eChoose this 1 L platform when your R\u0026amp;D work calls for anchor mixing and controlled heating of a suitable viscous formulation. Its 300–1,000 mL useful range without a disperser makes the intended batch scale clear before you choose the system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eFollow the batch, not just the speed dial\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eUse the TFT view to follow medium temperature and relative torque changes at constant set speed. Pause heating and stirring to use onboard weighing. Add a suitable pH electrode separately if pH measurement belongs in your method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eStart with the core hardware already selected\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eThe Control base, LR 1000.3 vessel, PEEK-scraper anchor and PT 100.30 sensor are specified together under US order code 0025001992. You can distinguish the core system from optional cooling, vacuum or dispersing equipment instead of budgeting for an undefined collection of parts.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 calc(50% - 12px);min-width:min(280px,100%);box-sizing:border-box;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:18px;\"\u003e\n\u003ch3 style=\"font-size:1.12rem;line-height:1.3;font-weight:600;color:#13314E;margin:0 0 12px;\"\u003eChoose Control for functions you will actually use\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0;\"\u003eControl is the choice when its TFT interface, weighing, relative torque trend and pH connection support your workflow. If those functions are unnecessary, compare Basic instead. Both versions share the stated 1 L maximum volume and 120°C medium limit; Control does not buy a larger vessel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px;padding:16px;border:1px solid #D9C49B;border-radius:8px;background:#FFF9EF;box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-size:1.05rem;font-weight:600;color:#57482D;margin:0 0 9px;\"\u003eChoose another platform when the limits do not fit\u003c\/h3\u003e\n\u003cp style=\"font-size:.97rem;line-height:1.65;margin:0;\"\u003eNeed less than 300 mL without a disperser, more than 1 L, positive-pressure reaction service or a medium temperature above 120°C? This is not that configuration. With an optional disperser, the separate minimum is 500 mL. For calibrated absolute viscosity, select a suitable viscometer rather than treating torque trend as a viscosity result.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat comes with the US Control system?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Close-up of the LR 1000 reactor vessel, lid ports and anchor assembly from the manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-vessel.webp?v=1793763115 1000w\" style=\"width:100%;max-width:440px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eActual photograph detail, not a second vessel. The Control vessel uses FFKM O-ring material and PEEK scrapers; suitability still depends on the medium and conditions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe vessel, stirrer and temperature sensor are part of the system\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000 control base, US 115 V, 50\/60 Hz.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000.3 laboratory reactor vessel.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eLR 1000.10 anchor stirrer with PEEK scrapers, listed in the current US system scope.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003ePT 100.30 temperature sensor and the supplied sensor receptacle, listed as LR 1000.62 in the current US order scope.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSilentstream, support rod and two hose connectors.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUSB A to Micro-B cable, 2 m. The operating manual also identifies a mains cable and tool kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNot listed as supplied:\u003c\/strong\u003e a pH electrode, T 25 disperser and reactor-specific dispersing tool, external chiller or other cooling supply, vacuum pump, reflux condenser or labworldsoft software license. Select those separately when the application needs them.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual covers both Basic and Control and includes shared installation illustrations. Use the Control column and the actual supplied components; a shared drawing is not proof that every illustrated accessory is in this package.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMix viscous formulations with a defined batch window\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAnchor mixing for suitable viscous media\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe supplied anchor and PEEK scrapers support mixing within the 10–150 rpm range. The published maximum viscosity is 100,000 mPa·s. This is a selection limit, not a promise of identical performance at every fill, speed, temperature or formulation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWork at a useful laboratory scale\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manufacturer specifies 300–1,000 mL without a dispersing tool and 500–1,000 mL when an appropriate dispersing tool is fitted. Do not treat the 1 L maximum as a universal recommended charge or assume it is a micro-volume reactor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose chemistry against the contact materials\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Control configuration includes stainless steel, borosilicate glass 3.3, PTFE, PEEK and FFKM in the documented wetted assembly. Check chemical, seal and temperature compatibility for the actual formulation; the material list is not blanket solvent approval.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSee the process, not just the speed setting\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Genuine detail of the LR 1000 control TFT display and rotary controls\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-controls.webp?v=1793763115 1000w\" style=\"width:100%;max-width:440px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eA crop of the real manufacturer photograph. Readings are illustrative, not a recipe, calibration reference or recommended operating settings.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eTFT operation with useful formulation measurements\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eControl brings the main operating values together on a color TFT display, with rotary\/push controls and an intuitive menu. Follow sample temperature and stirring settings, use the integrated weighing function and observe relative torque changes during your method.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eWeighing:\u003c\/strong\u003e the specified range is 3–2,000 g with 1 g resolution. Heating and stirring must be deactivated for weighing, as the manual requires. It can simplify formulation additions in the reactor, but it does not replace an analytical balance when your method requires finer or certified mass measurement.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eTorque trend:\u003c\/strong\u003e this is a relative process indicator. Use a constant set speed for torque-trend measurement; the manual says it cannot be combined with intermittent mode. A change may help you see how a formulation develops under consistent conditions, but the reactor does not report a calibrated absolute viscosity in mPa·s.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003epH:\u003c\/strong\u003e the integrated BNC connection and TFT display support pH measurement with a suitable separately selected electrode. A probe is not in the listed standard delivery. Calibrate the selected electrode before measurement; the manual requires an inserted temperature sensor for calibration. Chemical compatibility and the applicable probe instructions still matter.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUSB and RS 232 support a separately configured PC workflow. IKA labworldsoft is optional software, not a license included with this system. No automatic electronic-record, audit-trail or regulatory-compliance claim is made.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHeat the medium within its working-temperature limit\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e120°C working temperature is not the same as the heater rating\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe integrated heating block supplies heat through the vessel base. The external PT 100 temperature sensor measures the medium so heating can be controlled around the process temperature rather than an assumed hotplate setting.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eThe maximum working temperature of the medium is 120°C.\u003c\/strong\u003e A separate 180°C heating-block specification appears in the manufacturer’s data; it is not permission to operate the formulation at 180°C.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual requires the external temperature sensor to remain immersed in the medium, with at least 20 mm insertion depth. Set the adjustable safety circuit appropriately for the medium and method, and account for residual heat before handling or removing the vessel.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe equipment shuts off stirring and heating when the vessel or lid is removed during operation. These protections do not replace operator supervision, a suitable risk assessment or the full safety instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"LR 1000 control with its vessel seated on the integrated heated base\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115 1000w\" style=\"width:100%;max-width:500px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eHeating is integrated in the base. No external hotplate is required for the specified heating function, and no external cooling instrument is supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAdd external cooling when the method calls for it\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Manufacturer rear view of the LR 1000 control showing cooling and electrical connections\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-rear.webp?v=1793763115 1000w\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eRear-view photograph. Cooling connections serve the base’s cooling coils; this is not an included chiller or a general-purpose pressurized jacket circuit.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCooling connections are built in. The cooling supply is separate.\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFlow-through cooling uses integrated cooling coils in the base. Connect an appropriate external cooling arrangement when your method needs controlled heat removal or a cooling step. The system is not supplied with a recirculating chiller.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manufacturer lists a \u003cstrong\u003e3°C minimum cooling-medium temperature\u003c\/strong\u003e and \u003cstrong\u003e1 bar maximum permissible cooling-medium pressure\u003c\/strong\u003e. The operating instructions also require an unpressurized cooling arrangement. Do not connect an unrestricted pressurized supply or treat the 1 bar limit as a recommendation to pressurize the circuit.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSecure the hoses, provide the specified outlet\/drain arrangement and follow the manual’s connection instructions. The optional MV1 valve is installed only on the cooling inlet and must be selected and connected correctly.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor planning, separate the desired sample temperature from cooling-medium temperature, flow and available cooling capacity. A compatible connection alone does not guarantee the required cooling time for every batch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical formulation workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1260\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-workflow_phone.webp?v=1793763118\" width=\"720\"\u003e\u003cimg alt=\"Original LR 1000 formulation planning guide: define the batch, mix and control heat, follow process values, cool and document\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-workflow.webp?v=1793763115 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal planning guide. With an optional disperser, use the separate 500–1,000 mL useful-volume range. This diagram does not replace installation or safety instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBuild the method around the batch and its limits\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDefine the medium, target batch, contact-material compatibility and required mixing or dispersing route.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect the glass vessel, lid, seals, anchor and temperature sensor. Install and lock the equipment as the manual directs.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUse an appropriate charge and keep the PT 100 sensor immersed. Start stirring at a suitable low setting and adjust within the method’s limits.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eControl heat against the measured medium temperature. Follow relative torque and use weighing or a separately configured pH measurement where relevant.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUse the selected cooling arrangement when required. Stop, allow safe handling temperatures, isolate power for cleaning and record the method before changing the next batch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA visible torque change can be a useful process observation, but it is not proof of a particular viscosity, emulsion quality or validated endpoint. Establish and document your own acceptance criteria.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhich LR 1000 setup should I choose?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-selection_phone.webp?v=1793763118\" width=\"720\"\u003e\u003cimg alt=\"Original selection guide distinguishing this Control system from optional disperser, cooling, vacuum and pH additions\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-selection.webp?v=1793763115 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThis order is the 115 V Control system, not a bundle with every optional instrument. Separate hardware shown or described in family literature is not automatically supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose Control for additional process visibility\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis system adds the TFT interface, weighing function, relative torque-trend display, pH-electrode connection and MV1 control interface. Choose it when these functions contribute to your formulation workflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eConsider Basic when those extra functions are unnecessary\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe Basic and Control manual lists the same 1 L maximum volume, 10–150 rpm speed range and 120°C medium limit. Basic uses LED displays and does not supply Control’s weighing, pH or torque-trend functions. Control is not a higher-volume reactor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAdd high-shear dispersion as a separate configuration\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA lists the T 25 digital with reactor-specific S 25 KV-25 F or S 25 KV-25 G elements in the manual. The drive, appropriate tool and required fitting must be selected together. A generic T 25 shaft is not automatically the correct reactor tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eVacuum-capable does not mean pressure-reactor service\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe LR 1000 is designed for vacuum operation down to \u003cstrong\u003e25 mbar\u003c\/strong\u003e under the applicable equipment and process conditions. A suitable external vacuum arrangement is a separate selection; no vacuum pump is included in this system.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eIt is not designed for overpressure operation.\u003c\/strong\u003e At normal pressure, the reactor must remain appropriately ventilated to prevent pressure buildup. Volatile processes may also require a suitable condenser, containment and laboratory ventilation selected for the method.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not infer that the cooling-circuit pressure limit is an allowable reaction-vessel pressure. The system is not explosion-protected, and it must not be operated in an explosive atmosphere. Trained staff must assess hazardous media and follow the complete operating instructions.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCleaning and care that support the next batch\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eLet the equipment cool safely\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe heating block, vessel and lid can remain hot after the process stops. Stop stirring and isolate the electrical supply before accessory changes or cleaning, following the specified safe-removal procedure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eInspect the wetted assembly\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCheck the glass for damage and inspect the scraper, O-rings, shaft seal and connections. Wear and residue can affect both operation and process observations. Select cleaning agents that suit the actual materials and contamination risks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eProtect the electrical base\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not immerse the drive or wash it as if it were an empty glass vessel. The manual identifies product-contacting components as suitable for laboratory dishwashers, while electrical equipment and handles must not be immersed. Follow the separate component and cleaning-agent instructions; this is not an autoclave or sterilization claim.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor product return requests, start with Blue Tiger Scientific. IKA handles manufacturer technical support, warranty assessment, calibration where applicable and repairs under its terms. The operating manual states a 24-month warranty, with exclusions including wear, improper use and insufficient care.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBuild out the workflow selectively\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCompatible accessory:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-t-25-digital-ultra-turrax-disperser-drive?variant=53396356563242\" style=\"font-weight:600;color:#245B45;\"\u003eIKA T 25 digital drive, US 100–120 V\u003c\/a\u003e. IKA lists this drive as a reactor accessory. It is drive-only: select the reactor-specific S 25 KV tool and required mounting\/fitting separately. The S 25 N-18 G tool sold for other T 25 work is not established here as the reactor tool.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-multidrive-basic-m20-successor-package-0010010968?variant=53420411814186\" style=\"font-weight:600;color:#245B45;\"\u003eMultiDrive basic M20 Successor Package for a separate dry-sample preparation step\u003c\/a\u003e. Use only when its specified dry-grinding method and sample limits fit the broader workflow; this is not a reactor attachment or permission for solvent milling.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-rv-10-digital-pro-v-c-complete-115v-0010012821?variant=53420242895146\" style=\"font-weight:600;color:#245B45;\"\u003eRV 10 digital pro V-C Complete for separate rotary evaporation\u003c\/a\u003e. This is a distinct concentration\/solvent-removal system, not a vacuum-pump accessory included with the LR 1000.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-lr1000-purchase-guide\" style=\"padding:22px;margin:24px 0;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;box-sizing:border-box;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 14px;\"\u003eReady to specify your LR 1000 control?\u003c\/h2\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;color:#13314E;margin:0 0 10px;\"\u003eOrdering the standard 115 V system\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 16px;\"\u003eChoose catalog \u003cstrong\u003e0025001992\u003c\/strong\u003e when the supplied vessel, scraper anchor and temperature-sensing setup match your method. Review the included-parts checklist and the delivery options shown with your order. Optional external instruments are not included in the standard system.\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;color:#13314E;margin:0 0 10px;\"\u003eNeed options or procurement confirmation?\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eTell Blue Tiger your target batch volume, formulation type and whether you need dispersion, cooling, vacuum or pH measurement. Ask us to confirm the order scope, request current manufacturer availability and dispatch information, and coordinate any manufacturer application questions before a time-critical purchase.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block;max-width:100%;padding:12px 16px;box-sizing:border-box;border-radius:6px;background:#245B45;color:white;text-decoration:none;font-size:1rem;font-weight:600;line-height:1.4;\"\u003eAsk about options or availability\u003c\/a\u003e\u003cp style=\"font-size:.9rem;line-height:1.6;margin:12px 0 0;color:#526158;\"\u003eMention LR 1000 control and catalog 0025001992. Manufacturer stock and dispatch are confirmed separately. The checkout weight allowance is provisional, and automated arrival dates are not a confirmed supplier lead time.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:30px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:18px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included with IKA LR 1000 control System 0025001992?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe US 115 V system includes the Control base, LR 1000.3 reactor vessel, LR 1000.10 anchor stirrer with PEEK scrapers, PT 100.30 sensor and supplied receptacle, Silentstream, support rod, two hose connectors and a USB cable. The manual also identifies the mains cable and tool kit. A pH electrode, disperser, external chiller, vacuum pump and labworldsoft software license are separate selections.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhy choose LR 1000 control rather than LR 1000 basic?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eChoose Control for its TFT operation, integrated weighing, pH-electrode connection, relative torque-trend display and MV1 valve interface. Both versions share the manual’s 1 L maximum useful volume, 10–150 rpm range and 120°C medium limit. Control adds instrumentation and workflow functions, not a larger reactor capacity.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow small a batch can I run in the LR 1000 control?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA specifies 300–1,000 mL without a dispersing tool and 500–1,000 mL with an appropriate dispersing tool. For 0025001992, choose the charge against the installed configuration and keep the temperature sensor immersed at least 20 mm as the manual requires. Do not assume the 1 L system supports arbitrary micro-volume batches.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I operate the formulation at 180°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The maximum working temperature of the medium is 120°C. The separate 180°C figure is a heating-block specification, not an allowable 180°C sample temperature. Follow the medium limit, immersed sensor requirement, material compatibility and adjustable safety-circuit instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 100,000 mPa·s rating mean it measures viscosity?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The LR 1000 control has a maximum published viscosity rating of 100,000 mPa·s and a relative torque-trend display. The display indicates changes under the method’s conditions; it is not a calibrated absolute viscosity reading or a substitute for a suitable viscometer. Performance still depends on the formulation, charge, stirrer and operating conditions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs a chiller included, and can I connect ordinary pressurized tap water?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eA chiller is not included. Cooling uses the base’s integrated coils and a separately selected supply. The data lists a 3°C minimum cooling-medium temperature and 1 bar maximum permissible cooling-medium pressure; the manual also requires an unpressurized cooling arrangement. Do not connect an unrestricted pressurized supply. Follow the inlet, outlet and hose instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan the LR 1000 control be used under vacuum or positive pressure?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIt is designed for vacuum operation down to 25 mbar with an appropriate separately selected setup. It is not designed for overpressure use. At normal pressure, the reactor must be appropriately ventilated to prevent pressure buildup. Cooling-circuit pressure is not a reaction-vessel pressure rating. No vacuum pump is included in 0025001992.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I add a T 25 digital disperser, and will any S 25 tool fit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA lists T 25 digital as an accessory, and the reactor manual identifies S 25 KV-25 F and S 25 KV-25 G dispersing elements. Select the correct drive, reactor-specific tool and fitting together. The generic S 25 N-18 G sold for other T 25 work must not be assumed to fit this reactor. Dispersion requires the separate 500–1,000 mL useful-volume range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53447374733610,"sku":"BTS-0025001992","price":18133.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-lr1000-control-system.webp?v=1793763115","url":"https:\/\/bluetigerscientific.com\/products\/ika-lr-1000-control-laboratory-reactor-system-115v-0025001992","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}