{"product_id":"ika-ks-4000-ic-control-incubator-shaker-115v-0003510101","title":"IKA KS 4000 ic control Incubator Shaker, 115 V","description":"\u003cdiv id=\"bts-ika-ks4000ic\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:20px;border:1px solid #B9CADA;border-radius:10px;background:#F3F6FA;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.04em;color:#245B45;\"\u003eIKA KS 4000 ic CONTROL • 0003510101 • US 115 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;margin:0 0 20px;\"\u003eOrbital incubation with an external-cooling route when heating alone is not enough.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose the \u003cstrong\u003eIKA KS 4000 ic control\u003c\/strong\u003e when a suitable vessel-shaking method needs the KS 4000 format with a built-in circuit for \u003cstrong\u003eexternal-fluid cooling\u003c\/strong\u003e. It combines a \u003cstrong\u003e20 mm orbit\u003c\/strong\u003e, heating and electronic speed\/time controls within a \u003cstrong\u003e90 L chamber\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUS catalog \u003cstrong\u003e0003510101\u003c\/strong\u003e is the \u003cstrong\u003e115 V ic version\u003c\/strong\u003e. Current technical data states \u003cstrong\u003e12–80°C with coolant inlet temperature above 3°C\u003c\/strong\u003e. Actual below-ambient operation depends on the external cooling supply, load, room conditions and method.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eTwo separate selections matter:\u003c\/strong\u003e a compatible vessel-holding attachment is required, and cooled operation needs an appropriate external cooling unit and installation. Neither is included. The ic is \u003cstrong\u003enot a self-contained compressor refrigerator\u003c\/strong\u003e or a ready-to-run, fully accessorized culture system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Genuine manufacturer photograph of IKA KS 4000 ic control incubator shaker\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182 1000w\" style=\"width:100%;max-width:620px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer illustration of the ic instrument. External cooler, vessel holder, vessels and sample material are not included. Display readings are examples, not method recommendations.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e12–80°C\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eConditioned range; coolant inlet above 3°C\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e90 L chamber\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eNot a liquid sample-capacity rating\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e20 mm orbit\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003e10–500 rpm, with load-dependent limits\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 145px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003eExternal cooling\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;line-height:1.5;\"\u003eSeparate cooling unit and setup needed\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIs the KS 4000 ic the right incubator shaker?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYour method needs a cooling route\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe ic has a built-in circuit connected to an external cooling unit. Choose it when heating-only, ambient-relative operation does not meet the method. Do not infer below-ambient capability from the i model’s similar appearance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYour vessels fit a defined attachment\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSelect a compatible holder for the actual vessel shape, number, fill and clearance. AS 4000.1 is a manufacturer-listed universal option, sold separately. A chamber is not itself a vessel-restraint system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYour load fits the speed envelope\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe 20 kg maximum includes attachment, vessels and contents. It is not a promise of 20 kg at 500 rpm. Secure and balance the layout, and select speed from the current manual’s load guidance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eYou can provide the cooling installation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSpecify coolant, hoses, pressure protection and drainage for the application. This base instrument does not arrive with an external cooler, a complete tubing\/limiter kit or a confirmed cooling-capacity calculation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat comes with US order 0003510101?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Actual chamber detail cropped from the KS 4000 ic manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-chamber.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-chamber.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-chamber.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-chamber.webp?v=1793904182 1000w\" style=\"width:100%;max-width:560px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThe empty chamber is not a supplied vessel-holding attachment. The 90 L figure describes enclosure volume, not a 90 L batch.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eInstrument, sensor and mounting hardware\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eKS 4000 ic control incubator shaker, US 115 V, 50\/60 Hz.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003ePT 1000.60 stainless-steel temperature sensor.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eFour short clamping screws and two long clamping screws.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eThe current manual additionally lists the mains cable, operating instructions, two cooling-hose connecting pieces and unlocking handle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eNot listed as supplied:\u003c\/strong\u003e a vessel attachment, vessels, external cooling unit, cooling hoses, pressure limiter, labworldsoft license or RS-232 cable. A built-in circuit and two connection pieces are not a complete external cooling installation.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe live US product list is shorter than the manual’s packing list; both identify the same ic instrument. We do not add an RS-232 cable from older cached descriptions or infer a specific cable\/plug configuration merely from an accessory listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eExternal cooling: select the circuit, not just a low setpoint\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe ic circuit transfers heat to a separately specified cooling unit\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe current manual confirms a cooler built into this ic variant, connected through the rear inlet\/outlet fittings to an external unit. It gives IKA RC 2 GREEN basic\/control as examples, not a complete application-sizing or delivery list.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eWater is the only permitted coolant, with antifreeze (for example, ethylene glycol), as specified by the manual. Do not substitute an arbitrary heat-transfer fluid. The cited instruction does not specify an antifreeze concentration.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eThe supplied connection pieces accept 10 mm interior-diameter hose. Confirm the temperature\/pressure suitability of the actual hoses and connections.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eKeep coolant inlet temperature above 3°C and observe the maximum permissible 1 bar pressure. The manual recommends a pressure limiter as a safeguard.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eRoute the drain hose to an appropriate drain as instructed; accumulated condensate needs a defined drainage route.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe published 12–80°C range is conditioned on the cooling supply and operating setup. No minimum flow or complete cooling-capacity sizing is established by the current instrument table. Confirm the cooler, pressure protection and heat-load requirements before treating a proposed combination as validated.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAnother cooler appearing in the Blue Tiger catalog, including HRC 2 GREEN control, does not by itself establish compatibility. This listing does not bundle a cooler or promise a specific circulator pairing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-cooling_phone.webp?v=1793904186\" width=\"720\"\u003e\u003cimg alt=\"Original cooling requirements guide: separate external cooler, permitted water and antifreeze, 10 mm hose, inlet above 3 degrees and maximum 1 bar, condensate drain\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-cooling.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-cooling.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-cooling.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-cooling.webp?v=1793904182 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003ePlanning requirements only, not a piping drawing or installation procedure. Read the current ic instructions and the selected cooling unit’s manual.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose the holder before counting vessel capacity\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"AS 4000.1 universal attachment shown as a separate compatible accessory\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width:600px) 100vw, 500px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-as4000-1-system.webp?v=1793829884\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-as4000-1-system.webp?v=1793829884\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-as4000-1-system.webp?v=1793829884\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-as4000-1-system.webp?v=1793829884 1000w\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eAS 4000.1 is a separate purchase, not part of the ic instrument order. Confirm the delivered roll configuration and required vessel layout.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAS 4000.1 is compatible, but it is not included\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA’s current ic accessory list identifies \u003cstrong\u003eAS 4000.1 \/ 0008022200\u003c\/strong\u003e as a compatible universal attachment. Its adjustable restraint format can support different suitable vessel layouts; the actual rolls, spacing and secured load must be reviewed for the intended vessels.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCompatible accessory:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-as-4000-1-universal-attachment-0008022200?variant=53455928820010\" style=\"font-weight:600;color:#245B45;\"\u003eAS 4000.1 universal attachment for the KS 4000 family\u003c\/a\u003e. Order it separately if it is the appropriate holding format for your vessels.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDo not turn a nominal vessel-layout example into a working-liquid or maximum-speed guarantee. The holder is not automatically supplied with a specific maximum-layout roll count simply because a brochure illustrates that layout. Fixing-clip and dish formats are separate attachment choices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSelect speed for the entire secured moving load\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Load guidance from the current manual: 6 kg at 500 rpm, 12 kg at 400 rpm, 15 kg at 300 rpm and 20 kg at 120 rpm\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-load.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-load.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-load.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-load.webp?v=1793904182 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal presentation of manufacturer standard-value guidance. Count attachment, vessels and contents. Balance and secure the load and reduce speed if operation is uneven.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e20 kg and 500 rpm are not a combined operating promise\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe instrument’s speed range is 10–500 rpm. The current manual gives load guidance of \u003cstrong\u003e6 kg at 500 rpm, 12 kg at 400 rpm, 15 kg at 300 rpm and 20 kg at 120 rpm\u003c\/strong\u003e. These refer to the complete moving load, not liquid mass alone.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eHolder geometry, vessel shape, center of gravity, fill and securing method affect smooth operation. Begin with an appropriate setting and reduce frequency if unstable. Disturbance monitoring is not a substitute for correct restraint or protection against every spill.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe 90 L chamber and 440 × 440 × 352 mm operating area are enclosure references. Vessel clearance, safe fill, holder layout and total moving load determine the actual usable setup. No universal chamber-to-liquid-capacity conversion is implied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eTemperature sensing and controls for the actual method\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMeasure the medium without merging different performance figures\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe supplied PT 1000.60 connects inside the chamber under the manual’s instructions. Its stainless-steel sensor can measure the medium; maintain at least 20 mm immersion and route the cable so shaking is not obstructed and the vessel cannot be tipped or damaged.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA reports control accuracy, temperature stability and temperature homogeneity under different defined vessel, water-load, room and target-temperature tests. A ±0.05 K stability reference is not unconditional accuracy or uniformity for every vessel arrangement.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe LED interface provides local speed, temperature and time settings, timed or continuous operation, and an RS-232 interface for separately configured software use. Core local control does not require a PC or labworldsoft purchase. A USB interface, RS-232 cable and software license are not promised.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eHood-open protection stops heating and shaking, but mechanical coast-down must finish before handling the load. Power-restoration behavior depends on the selected operating mode; do not assume every mode prevents restart. Review the temperature safety limit and method settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg alt=\"Actual KS 4000 ic LED controls cropped from the manufacturer photograph\" height=\"1000\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-controls.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-controls.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-controls.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-controls.webp?v=1793904182 1000w\" style=\"width:100%;max-width:450px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1000\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eGenuine panel detail. Displayed readings are illustrative, not recommended shaking or incubation conditions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eKS 4000 i or ic: choose the temperature architecture\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-selection_phone.webp?v=1793904185\" width=\"720\"\u003e\u003cimg alt=\"Selection guide comparing heating-only KS 4000 i and externally cooled KS 4000 ic, with separate holder requirements\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-selection.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-selection.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-selection.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-selection.webp?v=1793904182 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eThis order is ic, not the heating-only i. Neither the holder nor an external cooling unit is included in this ic instrument order.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThis ic order adds the external-fluid cooling circuit\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eChoose it when the cooling installation and the conditioned 12–80°C range meet the actual method. Below-ambient operation depends on external coolant supply, not a built-in compressor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThe separate i is heating-only\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe i model is specified for ambient +5°C to 80°C. It has no ic cooling circuit; simply buying an external chiller does not convert an i instrument into an ic.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHolder selection remains a separate decision\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBoth models need suitable vessel restraint. The extra temperature-control capability does not automatically supply or validate an attachment, vessel layout or maximum working fill.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eAlternative format:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-ks-4000-i-control-incubator-shaker-115v-0003510001?variant=53455885304106\" style=\"font-weight:600;color:#245B45;\"\u003eKS 4000 i control for a separately specified heating-only workflow\u003c\/a\u003e. Compare the actual temperature requirement before selecting the model.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical cooled-incubation setup workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eDefine the holder and cooling supply before choosing settings\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSpecify vessels, count, working fill, target temperature and total moving load.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eChoose and mount the appropriate holder; secure and balance every vessel.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSpecify the external cooler, permitted coolant, hoses, pressure safeguard and condensate drain for the application.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSelect load-appropriate speed, conditioned temperature, safety limit, timer and restart mode.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eObserve stable operation and verify the method; wait for complete stop and safe handling temperature before opening or removing the load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAllow the manual’s at least 100 mm clearance on all sides, plus access for the hood, ventilation, cooling connections, drainage and safe handling. Published body dimensions are not the complete installation-space allowance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cpicture\u003e\u003csource height=\"1320\" media=\"(max-width: 600px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-workflow_phone.webp?v=1793904185\" width=\"720\"\u003e\u003cimg alt=\"Planning workflow: choose attachment, specify external cooling, select appropriate conditions, route condensate and stop before handling\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 600px) 100vw, 600px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-workflow.webp?v=1793904182\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-workflow.webp?v=1793904182\u0026amp;width=350 350w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-workflow.webp?v=1793904182\u0026amp;width=600 600w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-workflow.webp?v=1793904182 1200w\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" width=\"1200\"\u003e\u003c\/picture\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003ePlanning overview only. The instrument, attachment and selected cooling-unit instructions govern installation and operation; this is not a culture protocol.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSafety, care, delivery and warranty\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis instrument is not a CO₂-controlled incubator, sterilizer, biosafety enclosure or explosion-proof system. Choose appropriate process safeguards, media, fill and temperature conditions. Do not treat control-surface antimicrobial marketing as protection of the sample.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIsolate power before fitting accessories, cleaning or service. Inspect holders, fasteners, vessels, hoses and drains; follow cleaning\/decontamination instructions after spills or broken glass. Plan suitable handling for a 55 kg instrument rather than treating it as a light bench accessory.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual states a two-year baseline warranty with exclusions for wear, improper use and inadequate care. Current IKA KS 4000 registration terms provide eligible extension coverage subject to their conditions; no unconditional period is promised for every holder, cooler or consumable. Blue Tiger Scientific handles purchases and return requests. IKA handles warranty assessment, technical support, calibration and repairs.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eShipping uses a disclosed 180 lb provisional equipment-packing allowance, not the 55 kg device mass as measured packed gross. Manufacturer stock, dispatch timing, actual cartons and any special delivery services require order-specific confirmation. The external cooler and holder are separate items, not hidden inside this weight allowance.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:22px;margin:24px 0;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;box-sizing:border-box;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSpecify the ic instrument, holder and cooling installation separately\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor \u003cstrong\u003eUS 115 V KS 4000 ic control \/ 0003510101\u003c\/strong\u003e, tell Blue Tiger the vessel type, size, count, working fill, target temperature, total moving load and available cooling arrangement. We can coordinate application and current configuration questions with IKA.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAS 4000.1 \/ 0008022200 is a separately ordered compatible holder option. The external cooler, hoses and pressure-protection arrangement need their own selection. No supplier-stock quantity, fixed dispatch date or validated cooler bundle is established by the store inventory setting.\u003c\/p\u003e\n\u003ca href=\"https:\/\/bluetigerscientific.com\/pages\/contact\" style=\"display:inline-block;max-width:100%;padding:12px 16px;box-sizing:border-box;border-radius:6px;background:#245B45;color:white;text-decoration:none;font-size:1rem;font-weight:600;line-height:1.4;\"\u003eConfirm my cooled-shaking setup\u003c\/a\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:30px;padding-top:20px;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes KS 4000 ic control 0003510101 include a cooler and vessel holder?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo external cooling unit or vessel-holding attachment is included. The ic has a built-in external-fluid cooling circuit. The US scope includes the instrument, PT 1000.60 and mounting screws; the manual also lists mains cable, instructions, two hose connection pieces and unlocking handle. A suitable holder and cooling installation are separate selections.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs the ic a self-contained refrigerated shaker?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo compressor refrigerator is supplied inside this order. The ic circuit connects to a separate external cooling unit. Current data states 12–80°C with coolant inlet above 3°C, within specified ambient conditions; the actual result depends on coolant supply, load and method. Do not interpret ic as an unqualified negative-temperature rating.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat cooling connections and limits must I account for?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe current manual specifies 10 mm interior-diameter hose connection, water as the only coolant (with antifreeze, for example ethylene glycol), inlet above 3°C and maximum 1 bar pressure. It recommends a pressure limiter and requires a condensate drainage route. Cooler flow, cooling capacity and the complete installation must be checked for the actual application.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan it shake 20 kg at 500 rpm?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eDo not combine those maxima. The load includes attachment, vessels and contents. Current standard-value guidance is 6 kg at 500 rpm, 12 kg at 400 rpm, 15 kg at 300 rpm and 20 kg at 120 rpm. Secure and balance the load and reduce frequency if unstable; these are not universal working-liquid guarantees.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs AS 4000.1 compatible with this ic model?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes. The current manufacturer ic accessory list identifies AS 4000.1 \/ 0008022200 as a compatible universal attachment. It is sold separately. Confirm the current delivered roll configuration and actual vessel layout; a maximum-count brochure layout does not prove the required rolls or vessels are included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow does 0003510101 differ from the heating-only KS 4000 i?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe ic adds the built-in circuit for external-fluid cooling and has a conditioned 12–80°C range. The separate i \/ 0003510001 is heating-only, ambient +5°C to 80°C. Both need a separate vessel holder. Buying a chiller does not give an i unit an ic cooling circuit.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes ±0.05 K mean every sample is controlled to that accuracy?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. IKA lists separate control accuracy, stability and homogeneity tests. The ±0.05 K stability reference uses one 0.5 L vessel, room 25°C and target 37°C; it is not universal accuracy or uniformity for every load. Use the supplied sensor correctly and verify the actual method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs HRC 2 GREEN control automatically compatible as the external cooler?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo automatic HRC 2 GREEN compatibility is established here. Any proposed cooler must be reviewed for coolant, pressure, flow, connections and thermal duty. The current manual gives RC 2 GREEN basic\/control as examples, not a ready-made system guarantee. A separately listed circulator is not part of this instrument order.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53469664444714,"sku":"BTS-0003510101","price":10767.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-ks4000ic-system.webp?v=1793904182","url":"https:\/\/bluetigerscientific.com\/products\/ika-ks-4000-ic-control-incubator-shaker-115v-0003510101","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}