{"product_id":"ika-c-mag-hs-7-digital-magnetic-hotplate-stirrer","title":"IKA C-MAG HS 7 digital Magnetic Hotplate Stirrer, 120 V","description":"\u003cdiv id=\"bts-ika-hs7\" style=\"font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;max-width:1400px;margin:0 auto;width:100%;box-sizing:border-box;\"\u003e\n\u003csection style=\"padding:24px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:10px;\"\u003e\u003cp style=\"font-size:.85rem;color:#245B45;letter-spacing:.08em;font-weight:600;\"\u003eIKA • C-MAG HS 7 DIGITAL • 0003487001 • 120 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);line-height:1.15;color:#13314E;font-weight:600;\"\u003eHeat the plate. Control the liquid. Know the difference.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:22px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBring controlled heating and magnetic mixing to routine research preparation. The IKA C-MAG HS 7 digital pairs a chemically resistant ceramic surface with an included PT 1000.60 sensor, so you can regulate temperature in the liquid rather than relying on the hotplate setting alone.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor one vessel at a time, with stirring capacity up to 10 L of water. This US configuration includes three IKAFLON stirring bars, making the instrument, sensor and starter bar selection a single clearly defined purchase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:1 1 280px;min-width:0;margin:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"638\" alt=\"IKA C-MAG HS 7 digital ceramic hotplate stirrer with LCD temperature display and separate temperature and speed controls\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.5;margin-top:8px;\"\u003eManufacturer photograph of the instrument. Included sensor and stirring bars are listed below, but are not shown.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e10 L\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eMaximum stirring volume, water\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e50–500 °C\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eHeating plate range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e100–1,500 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eStirring speed range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e180 × 180 mm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eCeramic plate\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWhat arrives with catalog 0003487001?\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;margin:10px 0;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKA C-MAG HS 7 digital, 120 V \/ 50–60 Hz\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × PT 1000.60 stainless-steel temperature sensor\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKAFLON 20 magnetic stirring bar\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKAFLON 30 magnetic stirring bar\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKAFLON 40 magnetic stirring bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eVessels, a sensor-support stand and clamp, and other accessories are not listed in IKA’s standard delivery scope. Arrange secure sensor positioning appropriate to your vessel. MINISTAR and MICROSTAR overhead stirrers are separate instruments, not included parts or verified add-on accessories for this hotplate.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eChoose it for the job, not just the maximum temperature\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eRoutine heated preparation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA practical fit for research buffer and reagent preparation when your liquid, vessel and process are suitable for magnetic stirring and hotplate heating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eTemperature-sensitive workflows\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse the supplied PT 1000.60 to control the liquid temperature. IKA specifies ±0.5 K control accuracy in the medium with PT1000; actual results still depend on a suitable, well-mixed setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eLow-viscosity mixing\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe 10 L rating is based on water. Viscosity, vessel geometry and stir-bar coupling determine usable capacity. For difficult, viscous loads, evaluate a separately configured overhead stirrer instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003ePlate temperature is not sample temperature\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA hotplate transfers heat through the vessel before it reaches the liquid. Reading the plate temperature does not tell you the temperature of the whole sample. The sensor changes where the instrument measures and controls.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWITHOUT THE SENSOR\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIn mode B or C, heating without PT1000 uses the plate temperature target. The liquid may be cooler and may respond more slowly. Do not treat a plate setpoint as a verified sample temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWITH THE INCLUDED SENSOR\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003ePT 1000.60 measures in the liquid. The target is the desired medium temperature, and the actual-temperature display reports the sensor reading. Keep the sensor at least 20 mm immersed, securely held and clear of the stirring bar.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRead the numbers correctly.\u003c\/strong\u003e The medium’s actual-temperature display resolves 0.1 K. That is different from the specified ±0.5 K control accuracy. Temperature setpoint increments are 1 K. Stirring speed is adjusted with the 0–6 scale; this model does not provide a numeric RPM display.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWill it fit your bench?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cfigure style=\"flex:1 1 240px;min-width:0;margin:0;\"\u003e\u003cdiv role=\"img\" aria-label=\"Top-view footprint diagram. Instrument body 215 mm wide and 330 mm deep; ceramic plate 180 by 180 mm. Overall height 105 mm.\" style=\"max-width:280px;margin:auto;background:#EFF3F7;border:2px solid #13314E;border-radius:8px;padding:18px;box-sizing:border-box;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:.9rem;font-weight:600;margin-bottom:12px;\"\u003eBODY WIDTH 215 mm\u003c\/div\u003e\n\u003cdiv style=\"border:2px solid #245B45;background:white;aspect-ratio:1;display:flex;align-items:center;justify-content:center;font-size:1rem;line-height:1.6;\"\u003eCERAMIC PLATE\u003cbr\u003e180 × 180 mm\u003c\/div\u003e\n\u003cdiv style=\"padding:15px 0 4px;font-size:.9rem;\"\u003eBody depth 330 mm\u003cbr\u003eOverall height 105 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigcaption style=\"font-size:.85rem;line-height:1.5;margin-top:12px;text-align:center;\"\u003eSimplified footprint guide. Not a vessel-size or clearance drawing.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAllow room beyond the 215 × 330 mm body for safe access, cables, sensor support and the vessel. The manual calls for at least 100 mm from walls and adjacent equipment and 800 mm of free space above the instrument.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe current IKA product data specifies a 180 × 180 mm ceramic plate and a 15 kg maximum load. Load and mixing volume are separate limits: neither is a guarantee that every vessel or viscous sample will work.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse a level, dry, fire-resistant, non-slip work surface and a grounded supply matching the 120 V nameplate. The instrument is rated IP21, not for immersion or washdown.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eA repeatable setup, from first mix to cool-down\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e1 • Prepare safely\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRead the manual and assess the chemicals and vessel. With the device off and unplugged for accessory installation, secure the sensor support. Connect the PT1000 with power off. Place the stir bar in a suitable vessel and keep the probe at least 20 mm immersed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e2 • Build stable circulation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStart with the speed control at its left stop. Increase gradually to create stable circulation, not splashing or vessel movement. Use the supplied bar that couples reliably in your vessel; maximum supported bar length is 80 mm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e3 • Set the liquid target\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSelect the appropriate operating mode, confirm the sensor reading, then set heat. Factory mode A requires PT1000 for heating. Let the mixed sample equilibrate before recording results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e4 • Shut down and cool\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSwitch heating off and allow the plate and vessel to cool. HOT indicates a plate above 50 °C while the unit remains powered in stirring or standby. A dark display after unplugging is not evidence that the surface is cool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eChoose the restart behavior deliberately\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe three operating modes change what happens after power is removed. Choose the mode as part of your laboratory procedure, not as a substitute for supervision.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;margin:10px 0;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMode A, the factory setting: heating requires PT1000; the temperature target resets to 0 °C and heating is off at power-on. A configurable HI TEMP value limits the adjustable target.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMode B: settings are retained after switch-off or a power interruption, with automatic restart behavior. Heating without the sensor is possible.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMode C: retains the mode B behavior and locks settings against adjustment. Return to A or B to change settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe independent safety circuit is fixed at 550 °C. It is not an adjustable solvent-specific cutoff. The family safety flyer also describes features of other IKA stirrers; do not assume every family-level feature applies to this model.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor trained laboratory use only. Do not use in explosive atmospheres. Evaluate flammable liquids and ignition risks using your lab’s risk assessment and the manual. The surface, sensor and vessel can all remain hot after heating stops.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eIf the result is not what you expected\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eThe bar loses coupling\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eReduce speed and check vessel centering, bar selection and viscosity. Increasing speed can make decoupling worse. E11 indicates a blocked motor; the manual directs a bar change or lower viscosity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eThe displayed temperature seems wrong\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eConfirm whether the display is reading the plate or PT1000. Check immersion and stable mixing. E5 concerns the sensor not being in the medium; do not treat this error as a comprehensive boil-dry guarantee.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eAn error stops the run\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSwitch off and correct the stated cause before restarting. E1 concerns a missing sensor in mode A, E3 internal overheating and E6 a defective sensor. Stop use and seek service if a fault persists.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eComplete the preparation workflow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/heathrow-scientific-erlenmeyer-flasks-borosilicate-glass-graduated-narrow-neck\" style=\"color:#245B45;font-weight:600;\"\u003eHeathrow borosilicate Erlenmeyer flasks\u003c\/a\u003e offer a separate vessel-selection route. Check the selected flask’s dimensions, temperature limits and method suitability; this link is not a blanket fit or heating-compatibility claim.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/wire-lab-drying-rack\" style=\"color:#245B45;font-weight:600;\"\u003eHeathrow 90-position wire lab drying rack\u003c\/a\u003e supports the wash-and-dry stage after preparation. It is separate bench equipment, not a hotplate accessory.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:40px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:20px 0;font-family:Open Sans,sans-serif;font-weight:300;color:#333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included with IKA C-MAG HS 7 digital 0003487001?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 120 V instrument, one PT 1000.60 stainless-steel sensor and one each of the IKAFLON 20, 30 and 40 stirring bars. Vessels and sensor-support hardware are not listed in the standard scope.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs 0003487001 the US voltage version?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes. IKA’s current US technical data identifies 0003487001 as 120 V, 50\/60 Hz, with 1020 W power input. Do not confuse it with other regional versions or assume universal voltage.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 500 °C rating mean my sample reaches 500 °C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The current plate heating range is 50–500 °C. The liquid temperature depends on the sample, vessel and heat transfer. With the supplied PT 1000.60 immersed, the device controls to the measured medium temperature rather than substituting plate temperature for sample temperature.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes digital mean the instrument displays RPM?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Temperature is displayed digitally, but speed is adjusted using a 0–6 scale across a specified 100–1500 rpm range. Do not choose this model expecting a numeric RPM readout.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan it stir 10 L of a viscous liquid?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 10 L maximum is specified for water. Usable capacity for more viscous liquids depends on the sample and vessel, not volume alone. A separately selected overhead-stirring system may be more suitable; IKA’s MINISTAR and MICROSTAR recommendations do not establish accessory compatibility.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat happens after a power interruption?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThat depends on the mode. In factory mode A the heat target resets to 0 °C and heating is off at power-on. Modes B and C retain settings and have automatic restart behavior. Review the manual before selecting either retained-settings mode.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow do I know when the plate is safe to touch?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eHOT appears when the plate is above 50 °C while powered in stirring or standby. Do not rely on this warning after unplugging or loss of power. Allow the plate, sensor and vessel to cool before handling.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs this a clinical device, and is supplier stock confirmed?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThis listing is for research laboratory use, not diagnostic or medical use. Supplier availability and dispatch timing must be confirmed for the destination. IKA’s public page requires login to see availability; neither a listed price nor the 5 kg instrument weight establishes stock, freight or packed shipping weight.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53395441877290,"sku":"BTS-0003487001","price":1104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099","url":"https:\/\/bluetigerscientific.com\/products\/ika-c-mag-hs-7-digital-magnetic-hotplate-stirrer","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}