{"product_id":"hanna-instruments-hi93758c-50-total-phosphorus-low-range-reagents","title":"Hanna Instruments HI93758C-50 Total Phosphorus Low Range Reagents — 50 Tests","description":"\u003cdiv id=\"bts-hi93758c-50-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;background:#fff;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:20px;padding-bottom:20px;margin-bottom:24px;border-bottom:1px solid #e0e0e0;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eTotal Phosphorus Low Range — match the measured fraction\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChoose the total-phosphorus method when a reactive-only measurement would omit phosphorus forms targeted by digestion. Results are not a guarantee of recovery of every compound.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:0 1 310px;min-width:0;margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI93758C-50 reagent kit\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI93758C-50_-1200x1200-fda25479-7adb-41c2-b530-121de64b9475__77037.1791308324.jpg?v=1793829747\" style=\"width:100%;max-width:300px;height:auto;object-fit:contain;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eManufacturer photograph; follow the supplied lot instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F1F7F3;border-left:3px solid #245B45;padding:20px;box-sizing:border-box;margin:0 0 24px;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eChoose the right phosphorus fraction\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eReactive LR measures reactive orthophosphate without heat. Acid hydrolyzable includes free and condensed inorganic forms after heating. Total LR uses persulfate digestion for a broader total-phosphorus method.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eTotal Phosphorus Low Range: 0.00–1.15 mg\/L as P; 0.01 mg\/L resolution on HI83314 and HI83399.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003ePreparation at a glance\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eAdd 5 mL sample to an HI93758V-0 vial and add one PERSULFATE\/P packet. Cap and shake gently for 20 seconds until the powder dissolves. Heat for 30 minutes at 150 °C, then cool to room temperature in a rack. Add 2.0 mL HI93758C-0 NaOH solution and invert gently to mix. Clean and zero the same vial before adding one HI93758-0 phosphorus reagent packet. Shake gently for 2 minutes until the powder dissolves, wait 3 minutes and read.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat to have on hand\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eUse an HI83314 or HI83399 with 16 mm adapter, a 150 °C reactor such as the separately sold HI839800-01, cooling rack, accurate 5 mL and 2 mL dosing tools, wipes and SDS-directed PPE. The manual strongly recommends the HI740217 safety shield; check whether yours is already supplied.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003ePack capacity and contents\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eOne pack provides 50 nominal tests. The total-phosphorus method uses HI93758V-0 vials, PERSULFATE\/P packets, HI93758C-0 NaOH solution and HI93758-0 phosphorus reagent. HI93758V-0 is the vial specified for this method; do not substitute the HI93758V-0AH acid-hydrolysis vial.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eSafe handling and method limits\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eRead the matching current component SDS and instrument instructions before use. Never substitute an oven or microwave for the reactor: leaking samples can create a corrosive and potentially explosive atmosphere. Handle hot vials carefully. Store unused vials in their packaging in a cool, dark place. Check the manual for interference and waste requirements. Hanna classifies this offer as dangerous goods and states such goods can ship only by ground.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:400;margin:0 0 16px;color:#245B45;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat fraction does this kit measure?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eTotal phosphorus after acid\/persulfate digestion. The method targets more forms than a reactive-only measurement, but does not guarantee recovery of every compound.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat is the method range?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003e0.00–1.15 mg\/L as phosphorus (P), with 0.01 mg\/L resolution on HI83314 and HI83399.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhich photometers are supported?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eUse the HI83314 or HI83399 named phosphorus method with the 16 mm vial adapter. Select the correct phosphorus fraction on the instrument and follow its full procedure.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eHow many tests are in one pack?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eOne pack provides 50 nominal tests. Plan repeat measurements, quality-control checks and sample preparation separately when estimating your testing needs.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eDoes this method need a reactor?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. The instrument manuals specify 150 °C for 30 minutes; use a suitable reactor and cooling rack, sold separately.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhich vial and zeroing sequence does total phosphorus use?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eUse HI93758V-0, not HI93758V-0AH. Add the sample and PERSULFATE\/P, digest, cool, then add HI93758C-0 NaOH and mix. Zero that same vial before adding HI93758-0 color reagent.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eCan results be expressed as phosphate?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe instrument Chem Frm function converts the reported value to phosphate or phosphorus pentoxide. Conversion changes the expression basis, not the measured fraction; the listed numeric range is as P.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat else should I check before use?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eArsenate must be absent; silica above 50 mg\/L, sulfide, and substantial turbidity or suspended matter can interfere. Follow the instrument manual for sample treatment, wear SDS-directed PPE, and use appropriate chemical waste handling.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":53455926755626,"sku":"BTS-HI93758C-50","price":87.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI93758C-50_-1200x1200-fda25479-7adb-41c2-b530-121de64b9475__77037.1791308324.jpg?v=1793829747","url":"https:\/\/bluetigerscientific.com\/products\/hanna-instruments-hi93758c-50-total-phosphorus-low-range-reagents","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}