{"product_id":"hanna-hi96794-25-chloride-high-range-reagent-kit","title":"Hanna HI96794-25 Chloride High Range Reagent Kit — 25 Vials","description":"\u003cdiv id=\"bts-hi96794-25-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;background:#fff;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:20px;padding-bottom:20px;margin-bottom:24px;border-bottom:1px solid #e0e0e0;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eKnow your chloride level—not just your salt level.\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eMeasure chloride ion in water without a heated digestion step. This matched high-range reagent kit supports 80–1000 mg\/L as Cl⁻ on the documented HI83314 and HI83399 methods, helping you choose chloride chemistry rather than a chlorine or salinity test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:0 1 310px;min-width:0;margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI96794-25 high-range chloride kit with HI96794V-0 vials and HI96793-0 reagent bottle\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI96794-25_1w-1200x1200-db215e12-9f73-4b9d-b98e-392c8ada9f24__00431.1790013466.jpg?v=1793835004\" style=\"width:100%;max-width:300px;height:auto;object-fit:contain;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eFactory photograph identifies the HR kit and its shared-code liquid component. Packaging, lot and expiry shown are illustrative.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F1F7F3;border-left:3px solid #245B45;padding:20px;box-sizing:border-box;margin:0 0 24px;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eChoose the right analyte and range\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChoose this kit for chloride ion (Cl⁻), not free or total chlorine (Cl₂), and not sodium-chloride salinity. The documented range is 80–1000 mg\/L as Cl⁻. For expected levels below 100 mg\/L, the manuals recommend the lower-range method for improved precision; this page sells only the HR kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eA short, nonheated workflow\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eAdd 0.1 mL of sample to the sample vial. Slowly add 3 mL of HI96793-0 Chloride Reagent to each sample vial and to the separate blank vial, following the manual’s mixing instructions. Allow 3 minutes for color development, zero with the blank, then read the sample. No external heated digestion or reactor is specified.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat is included—and the real sample capacity\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eSupplied as the HI96794-25 high-range kit: 25 HI96794V-0 reagent vials and HI96793-0 Chloride Reagent bottle. HI96793-0 is the legitimate liquid component of this HR kit, not an alias for the HI96793-25 low-range kit. Total bottle fill volume is not stated here; the 3 mL dose is not a bottle-volume specification. One pack contains 25 reagent vials. The current instrument manuals specify reagents for 24 sample tests: a separate reagent blank consumes one vial. Up to 24 sample tests assumes one blank reused within the permitted window; fresh blanks, quality-control checks and repeats consume additional capacity. This is not a promise of 25 independent sample tests.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003ePlan batches around the reagent blank\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eReagent blank correction is required. The current manuals allow one blank to be reused for up to one day at room temperature in dark storage, or up to three days refrigerated. Bring a refrigerated blank to room temperature before measurement, and use the same reagent lot for blank and samples. This is a blank-use window, not an extension or guarantee of reagent expiry.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat you need separately\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eUse a compatible HI83314 or HI83399 photometer, the model-appropriate adapter specified by its current manual, accurate tools for 0.1 mL and 3 mL dosing, clean vial exteriors and suitable PPE. Instruments, adapters and dosing tools are not included. Select the Chloride HR method and follow the manual’s adapter instructions; no physical vial-diameter claim is made here.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003ePrepare the sample for a useful result\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eAnalyze promptly after collection. The manuals specify sample temperature 20–25 °C and initial sample pH 3–10, with pH below 2 after reagent addition. Filter turbid samples and adequately treat intense color. Bromide and iodide can give high-biased results; consult the full interference limits before interpreting a result. Store unused vials in their packaging at 15–25 °C and follow actual lot instructions and expiry.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eSafe handling and shipping review\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThese are hazardous laboratory reagents, including mercury-thiocyanate vial chemistry and an acidic liquid component. Read both exact-component US SDS before use and arrange appropriate waste handling. Component SDS contain transport classifications; they are not a complete-kit shipping determination. Confirm destination, packaging and carrier requirements before ordering. No air eligibility or blanket ground-only guarantee is made for this offer.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:400;margin:0 0 16px;color:#245B45;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eDoes this measure chlorine or salinity?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eChoose this kit for chloride ion (Cl⁻), not free or total chlorine (Cl₂), and not sodium-chloride salinity. The documented range is 80–1000 mg\/L as Cl⁻. For expected levels below 100 mg\/L, the manuals recommend the lower-range method for improved precision; this page sells only the HR kit.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eHow many sample tests can I obtain?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eOne pack contains 25 reagent vials. The current instrument manuals specify reagents for 24 sample tests: a separate reagent blank consumes one vial. Up to 24 sample tests assumes one blank reused within the permitted window; fresh blanks, quality-control checks and repeats consume additional capacity. This is not a promise of 25 independent sample tests.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhy does the bottle say HI96793-0?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eSupplied as the HI96794-25 high-range kit: 25 HI96794V-0 reagent vials and HI96793-0 Chloride Reagent bottle. HI96793-0 is the legitimate liquid component of this HR kit, not an alias for the HI96793-25 low-range kit. Total bottle fill volume is not stated here; the 3 mL dose is not a bottle-volume specification.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhich benchtop photometers support this kit?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eUse a compatible HI83314 or HI83399 photometer, the model-appropriate adapter specified by its current manual, accurate tools for 0.1 mL and 3 mL dosing, clean vial exteriors and suitable PPE. Instruments, adapters and dosing tools are not included. Select the Chloride HR method and follow the manual’s adapter instructions; no physical vial-diameter claim is made here.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eDoes the procedure need a digestion heater?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eAdd 0.1 mL of sample to the sample vial. Slowly add 3 mL of HI96793-0 Chloride Reagent to each sample vial and to the separate blank vial, following the manual’s mixing instructions. Allow 3 minutes for color development, zero with the blank, then read the sample. No external heated digestion or reactor is specified.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eHow long can I reuse the blank?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eReagent blank correction is required. The current manuals allow one blank to be reused for up to one day at room temperature in dark storage, or up to three days refrigerated. Bring a refrigerated blank to room temperature before measurement, and use the same reagent lot for blank and samples. This is a blank-use window, not an extension or guarantee of reagent expiry.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat sample conditions can affect results?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eAnalyze promptly after collection. The manuals specify sample temperature 20–25 °C and initial sample pH 3–10, with pH below 2 after reagent addition. Filter turbid samples and adequately treat intense color. Bromide and iodide can give high-biased results; consult the full interference limits before interpreting a result. Store unused vials in their packaging at 15–25 °C and follow actual lot instructions and expiry.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat safety documents and shipping checks are needed?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThese are hazardous laboratory reagents, including mercury-thiocyanate vial chemistry and an acidic liquid component. Read both exact-component US SDS before use and arrange appropriate waste handling. Component SDS contain transport classifications; they are not a complete-kit shipping determination. Confirm destination, packaging and carrier requirements before ordering. No air eligibility or blanket ground-only guarantee is made for this offer.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":53456358539562,"sku":"BTS-HI96794-25","price":137.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI96794-25_1w-1200x1200-db215e12-9f73-4b9d-b98e-392c8ada9f24__00431.1790013466.jpg?v=1793835004","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi96794-25-chloride-high-range-reagent-kit","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}