{"product_id":"hanna-hi937554-53-pool-line-chlorine-removal-reagent","title":"Hanna HI937554-53 Pool Line Chlorine Removal Reagent","description":"\u003cdiv id=\"bts-hi937554-53-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;background:#fff;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:20px;padding-bottom:20px;margin-bottom:24px;border-bottom:1px solid #e0e0e0;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eComplete the named HI971044 alkalinity preparation step\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eKeep the exact Pool Line chlorine-removal adjunct ready for your HI971044 alkalinity workflow. HI937554-53 is the separately orderable retail refill named in the six-digit instrument’s required-reagents table—not the similarly numbered legacy remover.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:0 1 310px;min-width:0;margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI937554-53 factory chlorine-remover photograph\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI937554-53-1200x1200__32884.1710863179.jpg?v=1793907731\" style=\"width:100%;max-width:300px;height:auto;object-fit:contain;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eFactory photograph of HI937554-53 with Pool Line carton.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F1F7F3;border-left:3px solid #245B45;padding:20px;box-sizing:border-box;margin:0 0 24px;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eChoose by the exact model and full reagent code\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChoose the full HI937554-53 code for the exact HI971044 method in MAN971044 11\/25, covering software v1.02 and higher. Its one-drop chlorine-removal step is required in that alkalinity procedure. Do not borrow the optional wording from the older HI97104 method or assume cross-model interchangeability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat this refill supplies\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThis is the named HI937554-53 Pool Line chlorine-remover refill. The official retail page calls it a chlorine removal kit; it is an adjunct, not a complete alkalinity test kit. No supplied liquid volume, bottle count or total test capacity is inferred from the factory photo or the one-drop method dose.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eBuild the complete alkalinity workflow\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHave your HI971044 photometer, the correct cuvette with stopper\/cap, a 1 mL syringe, a clean wipe and separately supplied HI775-26 alkalinity reagents. HI775S performs the analytical color reaction; the chlorine remover does not replace it.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eThe preparation step that protects your result\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eSelect Alkalinity and zero with 10 mL unreacted sample in the capped cuvette. Remove the cuvette, add one drop of HI937554-53 and swirl to mix. Add 1 mL HI775S with a syringe, replace stopper and cap, invert five times, reinsert in the correct orientation and read. The result is alkalinity in mg\/L as CaCO3, not chlorine concentration.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eHandling and documentation\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe official HI937554-53 SDS directory links a US sheet labeled HI937554-530. That is the directory-linked component identifier, not a replacement retail MPN or a chemical-alias claim. Follow the supplied label and applicable SDS for handling, storage and disposal; a component sheet is not a whole-kit transport or shipping guarantee.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:400;margin:0 0 16px;color:#245B45;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhy is the additional 5 in HI937554-53 important?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe exact US offer and factory bottle photograph both identify HI937554-53, and the HI971044 manual names it as Pool Line Chlorine Removal Reagent. It is a distinct retail listing from legacy HI93755-53, not a spelling correction or asserted chemical alias.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eIs the one-drop step optional on HI971044?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. MAN971044 11\/25 lists HI937554-53 under REQUIRED REAGENTS for alkalinity and instructs adding one drop and swirling after zeroing. The conditional wording for the older HI97104 is not applied to this method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhich HI971044 manual is referenced?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe referenced MAN971044 11\/25 manual covers software v1.02 and higher. Confirm your exact six-digit model and software, and follow the full instrument procedure and prompts.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eDoes this refill measure chlorine?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. It is a chlorine-removal adjunct in the alkalinity preparation. It is not a free- or total-chlorine measuring reagent and does not replace the instrument’s chlorine test reagents.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat else is needed for an alkalinity result?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYou need the HI971044, its correct cuvette, stopper\/cap, an accurate 1 mL syringe and the HI775S analytical reagent supplied through HI775-26. Zero the unreacted sample, add one drop remover, swirl, add 1 mL HI775S, invert five times and read as directed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat volume and number of tests does one order supply?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo commercial fill volume or per-order test count is established by the verified offer and exact-model method. The one-drop dose describes use, not the refill’s capacity. The factory image is shown for identity rather than as a packing census.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhy does the SDS say HI937554-530?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe official SDS directory for retail HI937554-53 links US PDF 15637 labeled HI937554-530. The document is retained under that component code; the product you are selecting remains retail MPN HI937554-53. This does not assert a chemical alias or whole-kit transport classification.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eCan I use it on HI97104 or other alkalinity meters?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThis page supports the exact HI971044 method and does not establish cross-model substitution. The older five-digit HI97104 names HI93755-53. Choose by the full model and reagent codes rather than the shared price or alkalinity name.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":53471411700010,"sku":"BTS-HI937554-53","price":16.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI937554-53-1200x1200__32884.1710863179.jpg?v=1793907731","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi937554-53-pool-line-chlorine-removal-reagent","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}