{"product_id":"hanna-hi93732-dissolved-oxygen-reagents","title":"Hanna HI93732 Dissolved Oxygen Reagents, 100\/300 Tests","description":"\u003cdiv id=\"bts-hi93732-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;background:#fff;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:20px;padding-bottom:20px;margin-bottom:24px;border-bottom:1px solid #e0e0e0;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eA colorimetric DO refill—not probe electrolyte.\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eReplenish the liquid chemistry used by your HI97732 dissolved oxygen photometer. HI93732-01 provides 100 tests and HI93732-03 provides 300, with the same A, B and C reagent method in either pack. Choose the set that matches your sample workload, not a dissolved oxygen probe maintenance kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:0 1 310px;min-width:0;margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI93732 official manufacturer reference packaging\" height=\"1201\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/30ml__39497.1569250925.jpg?v=1793474897\" style=\"width:100%;max-width:300px;height:auto;object-fit:contain;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eOfficial Hanna reference bottle image; it illustrates packaging rather than the complete three-component reagent set.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F1F7F3;border-left:3px solid #245B45;padding:20px;box-sizing:border-box;margin:0 0 24px;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eMatched to the HI97732 photometer workflow\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe HI97732 reports 0.0 to 10.0 mg\/L as O₂ using an adaptation of the azide-modified Winkler method. The chemistry develops a yellow color for optical measurement. It does not refill an electrochemical DO probe and is not an oxygen-scavenger reagent or HI3810 chemical-test-kit refill.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWill this method suit my water sample?\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThis set is for colorimetric dissolved oxygen determination in water samples, with careful collection and preparation to avoid changing the oxygen content. The HI97732 manual identifies reducing and oxidizing materials as interferences. Evaluate your exact matrix and method requirements; do not assume universal seawater or chemically treated-water suitability.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat comes in the selected set?\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe method uses HI93732A-0, HI93732B-0 and HI93732C-0 liquid reagents. Choose HI93732-01 for 100 tests or HI93732-03 for 300 tests. Bottle-volume and bottle-count configurations are not offered as separate options here; the ordering capacity is the manufacturer's stated test count.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat else is needed on the bench?\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHave the HI97732 photometer, a suitable 60 mL glass sample bottle and stopper, clean cuvettes and the meter-specific caps and stoppers ready separately. The procedure uses separate cuvettes for unreacted and reacted sample. CAL Check standards are separately supplied for checking instrument performance; they are not sample reagents.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eCollect without trapped air, then develop the color\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eFill the 60 mL bottle completely with sample. Add 5 drops each of A and B, refill to overflowing and close without trapped air. Invert as directed, allow about 2 minutes for settling, then add 10 drops of C when the upper half is clear. Invert until the precipitate dissolves and the sample is yellow and clear. This is a workflow overview; use the linked HI97732 manual for the complete preparation sequence.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eRead against the unreacted sample\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eZero the meter with 10 mL of unreacted sample in the first cuvette, then read 10 mL of reacted sample in the second. Keep the exterior of both cuvettes clean and dry. Check bottle lot and expiration markings, read all three component US Safety Data Sheets and follow appropriate chemical handling and waste procedures. Hanna classifies the set as Dangerous Goods for ground shipment only.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:400;margin:0 0 16px;color:#245B45;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eIs this electrolyte for a dissolved oxygen probe?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. HI93732 is liquid reaction chemistry for photometric dissolved oxygen determination. It does not refill a probe membrane or replace electrode electrolyte. This guide is based on the HI97732 photometer method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat is the difference between HI93732-01 and HI93732-03?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe stated capacity: 100 tests versus 300 tests. Both use the A\/B\/C liquid method and the same 0.0 to 10.0 mg\/L as O₂ range on HI97732. Order quantity 1 for one selected set.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhich reagent components does the method use?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eHI93732A-0, HI93732B-0 and HI93732C-0. The HI97732 procedure calls for 5 drops of A, 5 drops of B and 10 drops of C in the specified preparation sequence. Review the US SDS for each component.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhy must the sample bottle be free of air bubbles?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eTrapped air can change the dissolved oxygen measurement. The HI97732 method fills and refills the 60 mL bottle to overflowing before closure, then uses controlled inversion and settling. Follow the full collection and reaction instructions rather than shaking air into the sample.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhen do I add reagent C?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eAfter adding A and B and inverting, allow approximately 2 minutes for the flocculating material to settle. Add 10 drops of C when the upper half of the bottle is clear, then invert until the material dissolves and the sample is yellow and clear, as specified by the manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eDo I zero with the reacted sample?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. The HI97732 method zeros with 10 mL of unreacted sample in the first cuvette and reads 10 mL of reacted sample in the second. Keep the two cuvettes identified to avoid swapping them.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eAre the meter, bottle and CAL Check standards included?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. This is a reagent set. Supply the HI97732 photometer, 60 mL sample bottle with stopper, cuvettes and matched caps separately. CAL Check standards are separate instrument-check products, not substitutes for A\/B\/C sample chemistry.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eCan I use this for any marine or treated-water sample?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eDo not assume that. The HI97732 manual identifies reducing and oxidizing substances as interferences. Assess the matrix against the exact instrument method and seek method-specific guidance where needed. The set is Dangerous Goods for ground shipment; review all component SDS before use.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"100 tests | HI93732-01","offer_id":53402720928042,"sku":"BTS-HI93732-01","price":109.99,"currency_code":"USD","in_stock":true},{"title":"300 tests | HI93732-03","offer_id":53402720960810,"sku":"BTS-HI93732-03","price":313.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/30ml__39497.1569250925.jpg?v=1793474897","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi93732-dissolved-oxygen-reagents","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}