{"product_id":"hanna-hi93717-phosphate-high-range-reagents","title":"Hanna HI93717 Phosphate HR Reagents, 100 or 300 Tests","description":"\u003cdiv id=\"bts-hi93717-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;border-bottom:1px solid #e0e0e0;padding-bottom:24px;margin-bottom:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 500px;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eReady your HI97717 for the next water sample\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eReplenish phosphate high range testing without replacing your photometer. Choose HI93717-01 for 100 tests or HI93717-03 for 300 tests; both supply the same matched chemistry for the HI97717 method. The instrument, cuvettes and CAL Check standards are sold separately.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHanna prepares these reagents with high-purity chemicals and marks each bottle and packet with a lot number and expiration date. The larger pack supports a greater testing workload without changing the analytical method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:1 1 350px;min-width:min(250px,100%);margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI93717-01 official reagent reference packaging\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/phosphate-hr-range-100-tests-hi9I93717-01__21129.1575313870.jpg?v=1793383945\" style=\"width:100%;max-width:360px;height:auto;object-fit:contain;border-radius:8px;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eManufacturer reference packaging. Bottle and packet appearance, lot numbers and printed dates are illustrative, not the expiration date of supplied stock.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;border-bottom:1px solid #e0e0e0;padding-bottom:24px;margin-bottom:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 100%;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eChoose chemistry and reporting units together\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe amino acid method develops a blue tint in the sample. A compatible photometer measures that color to determine phosphate concentration.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe HI97717 method covers 0.0 to 30.0 mg\/L as phosphate (PO₄³⁻). The HI97717 primary result is phosphate (PO₄³⁻), not phosphorus (P). Its Chemical Form menu can display phosphorus or phosphorus pentoxide (P₂O₅); retain the correct chemical basis when recording or comparing results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eWhat your selected pack supplies\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eEach option is a reagent-only set for the stated test count: liquid reagent a plus powder reagent b. The HI97717 procedure consumes 10 drops of HI93717A-0 and 1 packet of HI93717B-0 per determination. Have a compatible meter, clean cuvettes with stoppers and caps, and the required sample-handling accessories ready separately. CAL Check standards check instrument performance; they do not react with actual samples in place of these reagents.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eFollow the HI97717 method sequence\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eZero the HI97717 using 10 mL of unreacted sample. Remove the cuvette, add 10 drops of HI93717A-0 and one packet of HI93717B-0, then stopper and cap it. Shake gently until the powder is completely dissolved. Return the cuvette to the meter and start the 5 minute countdown before reading.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eKeep the cuvette exterior clean and dry, exclude bubbles and follow the complete linked method manual for interference information and handling guidance. Review both US Safety Data Sheets before use and follow appropriate disposal procedures.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eSelect a pack for your testing workload\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHI93717-01 provides enough reagent for 100 tests, while HI93717-03 provides enough for 300 tests. Balance expected usage against the expiration date on your supplied stock. Manufacturer photos show reference packaging; any old printed expiration dates are illustrative and do not describe the stock you will receive.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eConfirm your instrument and method\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eIn addition to HI97717, the mapped Hanna manuals explicitly list these reagent packs for HI83300, HI83303, HI83305, HI83306, HI83308, HI83325, HI83399. Use the complete method for your exact instrument rather than transferring timings or ranges between models.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThis is one combined high range method set: liquid A and powder B are used together, not as alternative methods. It is not the low range HI93713 chemistry or HI713-25 Checker reagents. Hanna marks both pack sizes as Dangerous Goods for ground shipment only.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat changes between HI93717-01 and HI93717-03?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe test capacity: HI93717-01 supplies 100 tests and HI93717-03 supplies 300 tests. Both are the same matched reagent chemistry; the larger pack does not expand the measurement range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is the range and reporting basis on HI97717?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe HI97717 method range is 0.0 to 30.0 mg\/L as phosphate (PO₄³⁻). The HI97717 primary result is phosphate (PO₄³⁻), not phosphorus (P). Its Chemical Form menu can display phosphorus or phosphorus pentoxide (P₂O₅); retain the correct chemical basis when recording or comparing results.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eAre these liquid reagents or powder packets?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe set contains liquid reagent a plus powder reagent b. For each HI97717 determination use 10 drops of HI93717A-0 and 1 packet of HI93717B-0. The liquid and powder are complementary components of one method, not separate alternatives.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow do I prepare and time the sample?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eZero the HI97717 using 10 mL of unreacted sample. Remove the cuvette, add 10 drops of HI93717A-0 and one packet of HI93717B-0, then stopper and cap it. Shake gently until the powder is completely dissolved. Return the cuvette to the meter and start the 5 minute countdown before reading. Consult the full manual for the complete procedure and interferences.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich Hanna photometers are supported?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe verified manual map lists HI97717, HI83300, HI83303, HI83305, HI83306, HI83308, HI83325, HI83399. Check the exact instrument method before ordering; do not infer compatibility with all Hanna meters or Checker models.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the pack include a meter, cuvettes or CAL Check standards?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. These are reagent-only replenishment packs. The HI97717 or another explicitly compatible photometer, cuvettes, stoppers, caps and CAL Check standards are separate products. CAL Check standards do not replace sample reagents.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan I substitute a different range or reagent family?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThis is one combined high range method set: liquid A and powder B are used together, not as alternative methods. It is not the low range HI93713 chemistry or HI713-25 Checker reagents. Hanna marks both pack sizes as Dangerous Goods for ground shipment only.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat should I know about traceability, safety and shipping?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eCheck each supplied bottle and packet for its lot number and expiration date, and review both component US Safety Data Sheets in Manuals\/Brochures. Reference photo dates are illustrative, not current stock dates. Hanna classifies both packs as Dangerous Goods for ground shipment only.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"100 tests | HI93717-01","offer_id":53394999836970,"sku":"BTS-HI93717-01","price":42.89,"currency_code":"USD","in_stock":true},{"title":"300 tests | HI93717-03","offer_id":53394999869738,"sku":"BTS-HI93717-03","price":126.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/phosphate-hr-range-100-tests-hi9I93717-01__21129.1575313870.jpg?v=1793383945","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi93717-phosphate-high-range-reagents","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}