{"product_id":"hanna-hi93715-ammonia-medium-range-reagents","title":"Hanna HI93715 Ammonia MR Reagents, 100 or 300 Tests","description":"\u003cdiv id=\"bts-hi93715-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;border-bottom:1px solid #e0e0e0;padding-bottom:24px;margin-bottom:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 500px;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eReady your HI97715 for the next water sample\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eReplenish ammonia medium range testing without replacing your photometer. Choose HI93715-01 for 100 tests or HI93715-03 for 300 tests; both supply the same matched chemistry for the HI97715 method. The instrument, cuvettes and CAL Check standards are sold separately.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHanna prepares these reagents with high-purity chemicals and marks each bottle with a lot number and expiration date. The larger pack supports a greater testing workload without changing the analytical method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:1 1 350px;min-width:min(250px,100%);margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI93715-01 official reagent reference packaging\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ammonia-medium-range-reagents-hi93715-01__08915.1575313568.jpg?v=1793383931\" style=\"width:100%;max-width:360px;height:auto;object-fit:contain;border-radius:8px;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eManufacturer reference packaging. Bottle and packet appearance, lot numbers and printed dates are illustrative, not the expiration date of supplied stock.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;border-bottom:1px solid #e0e0e0;padding-bottom:24px;margin-bottom:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 100%;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eChoose chemistry and reporting units together\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eNessler chemistry produces a color change that the matched photometer uses to determine ammonia concentration.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe HI97715 method covers 0.00 to 10.00 mg\/L as ammonia nitrogen (NH₃-N). The HI97715 primary result is ammonia nitrogen (NH₃-N), not an interchangeable NH₃ mass concentration. Its Chemical Form menu can display ammonia (NH₃) or ammonium (NH₄⁺); use the manual when changing the reported form.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eWhat your selected pack supplies\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eEach option is a reagent-only set for the stated test count: liquid reagents a and b. The HI97715 procedure consumes 4 drops of HI93715A-0 and 4 drops of HI93715B-0 per determination. Have a compatible meter, clean cuvettes with stoppers and caps, and the required sample-handling accessories ready separately. CAL Check standards check instrument performance; they do not react with actual samples in place of these reagents.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eFollow the HI97715 method sequence\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eZero the HI97715 using 10 mL of unreacted sample. Add 4 drops of HI93715A-0, stopper and cap the cuvette, and invert five times. Add 4 drops of HI93715B-0 and repeat the five inversions. Insert the cuvette and start the 3 minute 30 second countdown before reading.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eKeep the cuvette exterior clean and dry, exclude bubbles and follow the complete linked method manual for interference information and handling guidance. Review both US Safety Data Sheets before use and follow appropriate disposal procedures.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eSelect a pack for your testing workload\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHI93715-01 provides enough reagent for 100 tests, while HI93715-03 provides enough for 300 tests. Balance expected usage against the expiration date on your supplied stock. Manufacturer photos show reference packaging; any old printed expiration dates are illustrative and do not describe the stock you will receive.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;\"\u003eConfirm your instrument and method\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eIn addition to HI97715, the mapped Hanna manuals explicitly list these reagent packs for HI83300, HI83303, HI83305, HI83306, HI83308, HI83314, HI83325, HI83399. Use the complete method for your exact instrument rather than transferring timings or ranges between models.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThis medium range A\/B set is not the low range HI93700 chemistry, the high range HI93733 chemistry or HI715-25 Checker reagents. Hanna marks both pack sizes as Dangerous Goods for ground shipment only.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat changes between HI93715-01 and HI93715-03?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe test capacity: HI93715-01 supplies 100 tests and HI93715-03 supplies 300 tests. Both are the same matched reagent chemistry; the larger pack does not expand the measurement range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is the range and reporting basis on HI97715?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe HI97715 method range is 0.00 to 10.00 mg\/L as ammonia nitrogen (NH₃-N). The HI97715 primary result is ammonia nitrogen (NH₃-N), not an interchangeable NH₃ mass concentration. Its Chemical Form menu can display ammonia (NH₃) or ammonium (NH₄⁺); use the manual when changing the reported form.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eAre these liquid reagents or powder packets?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe set contains liquid reagents a and b. For each HI97715 determination use 4 drops of HI93715A-0 and 4 drops of HI93715B-0. Both liquids are required for the same measurement.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow do I prepare and time the sample?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eZero the HI97715 using 10 mL of unreacted sample. Add 4 drops of HI93715A-0, stopper and cap the cuvette, and invert five times. Add 4 drops of HI93715B-0 and repeat the five inversions. Insert the cuvette and start the 3 minute 30 second countdown before reading. Consult the full manual for the complete procedure and interferences.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich Hanna photometers are supported?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe verified manual map lists HI97715, HI83300, HI83303, HI83305, HI83306, HI83308, HI83314, HI83325, HI83399. Check the exact instrument method before ordering; do not infer compatibility with all Hanna meters or Checker models.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the pack include a meter, cuvettes or CAL Check standards?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. These are reagent-only replenishment packs. The HI97715 or another explicitly compatible photometer, cuvettes, stoppers, caps and CAL Check standards are separate products. CAL Check standards do not replace sample reagents.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan I substitute a different range or reagent family?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThis medium range A\/B set is not the low range HI93700 chemistry, the high range HI93733 chemistry or HI715-25 Checker reagents. Hanna marks both pack sizes as Dangerous Goods for ground shipment only.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat should I know about traceability, safety and shipping?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eCheck each supplied bottle for its lot number and expiration date, and review both component US Safety Data Sheets in Manuals\/Brochures. Reference photo dates are illustrative, not current stock dates. Hanna classifies both packs as Dangerous Goods for ground shipment only.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"100 tests | HI93715-01","offer_id":53394996691242,"sku":"BTS-HI93715-01","price":80.29,"currency_code":"USD","in_stock":true},{"title":"300 tests | HI93715-03","offer_id":53394996724010,"sku":"BTS-HI93715-03","price":230.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ammonia-medium-range-reagents-hi93715-01__08915.1575313568.jpg?v=1793383931","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi93715-ammonia-medium-range-reagents","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}