{"product_id":"hanna-hi93705-silica-low-range-reagents","title":"Hanna HI93705 Silica Low Range Reagents, 100 Tests","description":"\u003cdiv id=\"bts-hi93705-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;background:#fff;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:20px;padding-bottom:20px;margin-bottom:24px;border-bottom:1px solid #e0e0e0;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHANNA PHOTOMETER REAGENTS · HI93705\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eKeep the full silica method on hand.\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHanna HI93705-01 replenishes low-range silica testing with a coordinated liquid-and-powder reagent set for 100 tests. It is a practical refill for an existing HI97705 setup—not a meter kit and not a single interchangeable powder packet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:1 1 350px;min-width:min(250px,100%);margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI93705-01 official manufacturer reference photograph\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/Generic-reagents__35591.1568317943.jpg?v=1793474873\" style=\"width:100%;max-width:360px;height:auto;object-fit:contain;border-radius:8px;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eOfficial Hanna generic reagent reference photograph used for HI93705-01. It is not a layout of the full A\/B\/C set; printed expiration dates are illustrative, not supplied-stock dates.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F1F7F3;border-left:3px solid #245B45;padding:20px;box-sizing:border-box;margin:0 0 24px;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eCheck the method before the pack size\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChoose HI93705-01 for the HI97705 silica low range method, covering 0.00 to 2.00 mg\/L as SiO₂. This is not HI705-25 Checker HC chemistry or silica high range reagent. Only the 100-test HI93705-01 pack is offered on this page.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eA defined reaction, a named reporting basis\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe ASTM D859-based heteropoly molybdenum blue reaction develops a blue color for photometric measurement. HI97705 normally reports silica as SiO₂; its chemical-form menu also offers silicon as Si. Those are different reporting bases, so record the selected chemical form with the result.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eCheck your sample matrix\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eUse water samples suitable for the exact HI97705 method; this is not a claim of universal marine or seawater suitability. Phosphate above 60 mg\/L can reduce the reading, with a larger effect reported above 75 mg\/L. Sulfide and high iron concentrations can also interfere. Review the manual’s color, turbidity and zeroing guidance for your sample matrix.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat the refill supplies\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe 100-test set combines liquid reagent A with powder reagents B and C. The HI97705 procedure specifies six drops of HI93705A-0, one packet of HI93705B-0 and one packet of HI93705C-0 per determination. The capacity refers to completed tests using all three components—not 100 total loose packets.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eSet up separately\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHave the HI97705 photometer, suitable clean cuvettes with stoppers and caps, a sample and any method-specific preparation accessories ready separately. None is included in this reagent refill. CAL Check standards are separate instrument verification materials, not sample reagents.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWork through the measurement sequence\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eBegin with 10 mL of sample. Add six drops of reagent A and swirl; allow the four-minute stage before adding reagent B. Add one B packet and dissolve it, then follow the one-minute stage and zeroing sequence. Add one C packet, dissolve it and use the three-minute countdown before reading. This is a staged method: do not zero plain sample and add all three reagents together. Use the HI97705 manual or tutorial for the complete sequence.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eSelect for your testing schedule\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eOrder quantity 1 for one HI93705-01 100-test reagent set. There is no pack-size dropdown because this listing has one verified current US configuration. Match the reagent code, the low-range method and your instrument before ordering; a reference to another size in a manual does not establish its current US availability.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eOther documented instrument methods\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHanna exact-model manuals also list this reagent family for HI83300, HI83305, HI83306, HI83308 and HI83399. Match the low-range parameter method and use the range and workflow for that instrument; compatibility does not mean identical measurement settings.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat exactly is included in HI93705-01?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe 100-test set combines liquid reagent A with powder reagents B and C. The HI97705 procedure specifies six drops of HI93705A-0, one packet of HI93705B-0 and one packet of HI93705C-0 per determination. The capacity refers to completed tests using all three components—not 100 total loose packets.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWill this work with my HI97705?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. The HI97705 method manual identifies HI93705-01 as the 100-test silica LR reagent set. It is separate from HI705-25 Checker HC and high range silica reagents.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat range does HI97705 measure with this set?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe stated range is 0.00 to 2.00 mg\/L as SiO₂. The instrument also offers a silicon (Si) display through Chemical Form; do not interpret the same number as both Si and SiO₂.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDo I zero the meter before adding any reagent?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNot for this staged HI97705 procedure. Add reagent A, observe its four-minute stage, add B, follow the one-minute stage and zero as directed, then add C and run the three-minute countdown. Follow the complete method or on-screen tutorial.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eAre all water matrices suitable?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eUse water samples suitable for the exact HI97705 method; this is not a claim of universal marine or seawater suitability. Phosphate above 60 mg\/L can reduce the reading, with a larger effect reported above 75 mg\/L. Sulfide and high iron concentrations can also interfere. Review the manual’s color, turbidity and zeroing guidance for your sample matrix.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eAre the meter, cuvettes and standards supplied?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. Have a compatible photometer, suitable cuvettes with stoppers and caps, and the accessories required by the method separately. CAL Check standards verify the meter and are not substitutes for the A\/B\/C sample reagents.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhy is there only a 100-test choice?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThis listing supplies HI93705-01, the 100-test refill. For a larger testing workload, order multiple 100-test sets.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat safety and shipping information should I review?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eRead the separate US Safety Data Sheets for HI93705A-0, HI93705B-0 and HI93705C-0 before use. Hanna marks the US set as Dangerous Goods with ground shipment only. Check supplied labels and expiration dates and follow the SDS handling and disposal guidance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":53402704871722,"sku":"BTS-HI93705-01","price":80.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/Generic-reagents__35591.1568317943.jpg?v=1793474873","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi93705-silica-low-range-reagents","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}