{"product_id":"hanna-hi802-01-iris-visible-spectrophotometer-barcode-reader-115v","title":"Hanna HI802-01 iris Visible Spectrophotometer with Barcode Reader — 115 V","description":"\u003cdiv id=\"bts-hi802-01-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;background:#fff;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHANNA IRIS · HI802-01 · VISIBLE SPECTROPHOTOMETER\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eVisible chemistry, with fewer method-selection steps.\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChoose the Hanna HI802-01 iris when your water or wastewater laboratory needs variable-wavelength measurements and a supported barcoded-vial workflow in one portable instrument. This is the US 115 V configuration, supplied with a 15 VDC power adapter—not the HI802-02 230 V version.\u003c\/p\u003e\n\u003cul style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;padding-left:22px;margin:12px 0 20px;\"\u003e\n\u003cli style=\"margin:7px 0;\"\u003eReduce manual method selection with the included reader for supported 13 mm barcoded reagent vials.\u003c\/li\u003e\n\u003cli style=\"margin:7px 0;\"\u003eMatch established visible-light chemistry—or develop documented user methods across 340–900 nm.\u003c\/li\u003e\n\u003cli style=\"margin:7px 0;\"\u003eKeep measurement records on the instrument and export CSV or PDF by USB; no proprietary transfer software required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#F1F7F3;border-left:3px solid #245B45;padding:18px;margin:24px 0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eThe right instrument starts with the method\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eBest fit: laboratories that need supported 13 mm barcode methods alongside cuvette-based visible assays and user-method flexibility. Not the right fit for full UV–Vis work: its 340–900 nm range cannot measure DNA\/protein absorbance at 260\/280 nm. A selectable wavelength does not make every assay, reagent or vial compatible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:20px;align-items:center;margin:24px 0;box-sizing:border-box;\"\u003e\n\u003cdiv style=\"flex:1 1 330px;min-width:0;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eWhat barcode recognition actually does\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eIn Barcode Methods mode, the HI802 reads supported Hanna 13 mm barcoded reagent vials through its dedicated adapter and identifies the corresponding method and parameter range. The method sets the measurement wavelength; you still follow the assay’s preparation, blank\/zero, timing and interference requirements.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThis is not a general-purpose product-barcode or sample-ID scanner. Recognition does not perform digestion, identify an unknown sample, eliminate quality controls or confer regulatory approval.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:0 1 310px;min-width:0;margin:0;text-align:center;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI802_Cuvette-bar-code-2.jpg?v=1793936783\" alt=\"Factory HI802 barcode-vial workflow and dedicated reader adapter\" width=\"500\" height=\"500\" loading=\"lazy\" style=\"width:100%;max-width:310px;height:auto;object-fit:contain;box-sizing:border-box;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.85rem;color:#555;\"\u003eFactory HI802 illustration: supported barcoded vial and dedicated adapter. Reagent vials are sold separately.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003csection id=\"bts-hi802-vial-efficiency\" style=\"margin:24px 0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eTwo ways to streamline supported vial methods\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003e\u003cstrong style=\"font-weight:400;\"\u003eOptional rotational averaging.\u003c\/strong\u003e With Average set to On for supported vial methods, vial rotation takes 256 absorbance readings and rejects outliers, helping reduce variation from minor vial imperfections. These are readings of one vial, not 256 samples; this does not apply to every cell type or guarantee analytical accuracy. Clean vials and the method’s quality controls remain essential.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003e\u003cstrong style=\"font-weight:400;\"\u003eShared zero, where designated.\u003c\/strong\u003e Shared-zero support can reduce repeated setup only for the manufacturer-designated barcode methods and wavelength groups. A matching wavelength alone does not establish eligibility; COD methods are not shared-zero eligible, and stored zero is not the same as shared zero. Follow each method’s reagent-blank and quality-control requirements.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eOptical flexibility, with defined limits\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe split-beam tungsten-halogen optical system covers 340–900 nm with 1 nm wavelength resolution, ±1.5 nm wavelength accuracy and 5 nm spectral bandwidth. Measurement modes are absorbance, transmittance and concentration; the photometric range is 0.000–3.000 Abs. Factory methods control wavelength selection; editable wavelengths belong to user methods.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChoose the exact analyte, concentration range, reagent code and cell format from the manual before ordering consumables. There is no single concentration range or accuracy that applies to every assay. This page does not promise continuous spectral scanning.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eIncluded instrument package—not an assay starter kit\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe current MAN802 07\/26 manual lists four 22 mm sample cuvettes with caps; a 16 mm cuvette adapter; a 10 mm square-cuvette adapter; the dedicated 13 mm barcode-vial adapter; wiping cloth; scissors; USB cable; 15 VDC power adapter; USB flash drive; protective dust cover; instrument quality certificate; and instruction manual.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eReagents, barcoded reagent vials, standards and a digestion reactor are not included. To run an assay, add the exact method’s chemicals, blanks\/standards, sample-preparation supplies, required cell format and safety equipment. Digestion methods additionally need the specified reactor and cooling arrangements. An instrument quality certificate is not a promise of a separate accredited calibration service.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eBuild and document a user method\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eUp to 100 user methods can define as many as five wavelengths and timers. For eligible single-wavelength concentration methods, calibration accepts up to ten points by measuring standards or entering absorbance values. Calibration is not available for absorbance, transmittance or multiwavelength methods; factory methods already contain their own curves. Developing a method still requires suitable standards, validation and your laboratory’s quality controls.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eStore up to 9,999 measured values and export records as CSV or PDF to USB flash storage or transfer them to a PC\/Mac over USB. No Wi-Fi, Bluetooth, automatic LIMS integration, electronic-signature system or audit-trail compliance is promised.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eHI802, HI801 or HI83399: choose the workflow\u003c\/h4\u003e\n\u003cdiv style=\"width:100%;box-sizing:border-box;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:'Open Sans',sans-serif;font-size:12px;font-weight:300;line-height:1.55;color:#555;table-layout:fixed;box-sizing:border-box;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:32%;padding:12px 10px;border:1px solid #e0e0e0;vertical-align:top;overflow-wrap:anywhere;box-sizing:border-box;font-weight:400;\"\u003eHI802 — this instrument\u003c\/td\u003e\n\u003ctd style=\"width:68%;padding:12px 10px;border:1px solid #e0e0e0;vertical-align:top;overflow-wrap:anywhere;box-sizing:border-box;font-weight:300;\"\u003eChoose when supported 13 mm barcode methods matter, alongside 340–900 nm variable-wavelength measurements and user methods. Its dedicated barcode adapter is included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"width:32%;padding:12px 10px;border:1px solid #e0e0e0;vertical-align:top;overflow-wrap:anywhere;box-sizing:border-box;font-weight:400;\"\u003eHI801 — alternative\u003c\/td\u003e\n\u003ctd style=\"width:68%;padding:12px 10px;border:1px solid #e0e0e0;vertical-align:top;overflow-wrap:anywhere;box-sizing:border-box;font-weight:300;\"\u003eAlso a 340–900 nm visible spectrophotometer with user-method capability. Its manual describes conventional 13 mm vial operation, not the HI802 barcode workflow. Do not fit the HI801 vial adapter into the HI802.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:32%;padding:12px 10px;border:1px solid #e0e0e0;vertical-align:top;overflow-wrap:anywhere;box-sizing:border-box;font-weight:400;\"\u003eHI83399 — separate alternative\u003c\/td\u003e\n\u003ctd style=\"width:68%;padding:12px 10px;border:1px solid #e0e0e0;vertical-align:top;overflow-wrap:anywhere;box-sizing:border-box;font-weight:300;\"\u003eChoose for a defined water\/wastewater photometer workflow with five fixed wavelengths (420, 466, 525, 575 and 610 nm), plus digital-electrode pH capability. It is not a continuously selectable-wavelength or HI802 barcode instrument; the pH electrode is separate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHI83399 is an alternative instrument, not a compatible accessory or a required second meter. Neither instrument choice removes reagent or digestion requirements. Compare your actual method list rather than a generic method-count claim.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;line-height:1.15;border-top:1px solid #e0e0e0;margin-top:28px;padding-top:12px;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;color:#245B45;margin:24px 0 12px;line-height:1.35;\"\u003eFrequently asked questions\u003c\/h4\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eIs HI802-01 the correct US configuration, and can it work away from mains power?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eYes. HI802-01 is the 115 V US version and includes a 15 VDC adapter; HI802-02 is the separate 230 V version. The instrument also uses a rechargeable 10.8 VDC Li-ion battery. The manual rates battery operation at 3,000 measurements or eight hours, excluding vial rotation; actual use and battery condition affect runtime.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eWill the barcode reader recognize our existing reagent vials or sample labels?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eOnly the supported barcoded 13 mm reagent-vial methods are documented. Match the reagent code and parameter range to the HI802 manual before purchase. The reader is not a universal barcode reader and does not scan arbitrary sample labels. Non-barcoded cuvette methods still require their specified method selection and preparation; the barcode feature does not make other suppliers’ vials compatible.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eCan it replace a full UV–Vis instrument or measure DNA at 260\/280 nm?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eNo. Its wavelength range starts at 340 nm and ends at 900 nm. It cannot perform measurements at 260 or 280 nm. Variable-wavelength selection supports methods within that range; it does not establish continuous spectral-scanning capability or compatibility with every visible assay.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eWhat do we need beyond this package to run our first assay?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eSelect the exact manual method, then obtain its specified reagents or barcoded vials, appropriate cells, blanks and standards, preparation tools and PPE. COD and other digestion procedures also require the specified reactor and cooling equipment. Four 22 mm cuvettes and the named adapters are included, but chemicals and a reactor are not. The hardware package alone is not ready to run every assay.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eHow many adapters are included, and can we reuse an HI801 adapter?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eMAN802 07\/26 identifies two cuvette adapters (16 mm round and 10 mm square) plus one dedicated 13 mm barcode-vial adapter: three adapter assemblies total. The manual explicitly warns against inserting an HI801 vial adapter, which can damage the HI802 holder. The 22 mm round and 50 mm rectangular formats do not need an adapter; additional cell formats are not all supplied.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eCan we create and calibrate our own methods?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eYes, within the documented user-method settings: up to 100 methods, up to five wavelengths and timers, and calibration with up to ten points for eligible concentration methods. Standards can be measured or absorbance values entered. Calibration is not available for absorbance, transmittance or multiwavelength methods. A programmed curve is not automatic method validation or regulatory acceptance; verify selectivity, range, interferences and quality controls for your application.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eHow do we export data, and does it connect directly to our LIMS?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eThe instrument stores up to 9,999 values and supports CSV\/PDF exports via USB flash drive and USB transfer to a PC\/Mac. Confirm that the exported fields meet your recordkeeping needs. No native LIMS connector, wireless connection, electronic signatures or regulatory data-integrity certification is specified here; any downstream integration needs separate assessment.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0;padding:16px 0;\"\u003e\u003csummary itemprop=\"name\" style=\"font-weight:400;cursor:pointer;line-height:1.4;\"\u003eWhen should we choose HI802 rather than HI801 or HI83399, and what warranty applies?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"line-height:1.65;padding-top:12px;\"\u003e\u003cp itemprop=\"text\" style=\"margin:0;\"\u003eChoose HI802 for supported barcode-vial work plus variable visible wavelengths. Compare HI801 for conventional variable-wavelength visible work, and HI83399 for its fixed-wavelength water\/wastewater methods and digital-electrode pH capability—not as an HI802 accessory. The HI802 manual states a two-year warranty against workmanship\/material defects for intended use and prescribed maintenance, limited to repair or replacement; accident, misuse, tampering and neglected maintenance are excluded. Service requires authorization and the manual’s return conditions. Shared shipping\/returns terms are in Additional Information.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":53479144128810,"sku":"BTS-HI802-01","price":3924.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/HI802_3__24549.1779131857.webp?v=1793936783","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi802-01-iris-visible-spectrophotometer-barcode-reader-115v","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}