{"product_id":"hanna-hi775-26-freshwater-alkalinity-reagents-25-tests","title":"Hanna HI775-26 Freshwater Alkalinity Reagents — 25 Tests","description":"\u003cdiv id=\"bts-hi775-26-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;max-width:1400px;margin:0 auto;padding:20px 12px;color:#26332C;background:#fff;\"\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:20px;padding-bottom:20px;margin-bottom:24px;border-bottom:1px solid #e0e0e0;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:0;box-sizing:border-box;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eKeep freshwater buffering-capacity checks on schedule\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eKeep freshwater buffering-capacity monitoring supplied with HI775-26: matched HI775S colorimetric reagent for 25 tests. Choose this refill to follow alkalinity trends with your compatible photometer—not to measure pH, calcium or marine alkalinity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:0 1 310px;min-width:0;margin:0;text-align:center;box-sizing:border-box;\"\u003e\n\u003cimg alt=\"Hanna HI775-26 manufacturer reagent photograph\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/freshwater-alkalinity-reagents-hi775-26__44741.1695138712.jpg?v=1793900736\" style=\"width:100%;max-width:300px;height:auto;object-fit:contain;\" width=\"1200\"\u003e\n\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-size:0.9rem;margin-top:8px;\"\u003eManufacturer component illustration; use the supplied lot label, not photographed dates or volumes.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F1F7F3;border-left:3px solid #245B45;padding:20px;box-sizing:border-box;margin:0 0 24px;\"\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eMatch the matrix, method and reporting basis\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003e0–500 mg\/L (ppm) as CaCO3; freshwater alkalinity, not calcium concentration\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChoose HI775-26 for the HI775 Checker or the documented alkalinity methods on HI83300, HI83303, HI83326, HI83399, HI97104 and HI971044. Match the method and cuvette to your exact model; HI755 marine and HI772 dKH reagents are not interchangeable with this freshwater formulation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eWhat one refill supplies\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eOne HI775-26 refill provides 25 tests and includes one syringe and one tip, as listed in the HI775 manual. The photometer, cuvettes and CAL Check verification materials are separate. Check any required chlorine remover separately.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eHave the complete testing workflow ready\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eHave your model-appropriate 1 mL dosing syringe\/tip, cuvette, stopper\/cap and lint-free wipe ready. This is a refill for an existing testing setup, not an instrument starter kit.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003ePlan for the method, not just the reagents\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eThe HI775 Checker method needs accurate dosing and prompt reading, so choose this refill for a workflow where you can complete each test without delay. Use the full \u003ca href=\"https:\/\/www.documentation.hannainst.com\/manuals\/download\/1309\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHI775 Checker manual\u003c\/a\u003e for preparation and handling; benchtop and portable photometer users must follow their own model’s complete method rather than copy Checker steps.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eCheck sample conditions before ordering\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eChlorine can interfere, so check whether your samples need the model-specified removal reagent before ordering. HI775 and HI97104 specify HI93755-53 when chlorine is present; HI971044 specifies HI937554-53 in its alkalinity procedure. Follow your exact model manual and do not substitute between these codes.\u003c\/p\u003e\n\u003ch4 style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;font-weight:400;line-height:1.35;margin:0 0 16px;color:#245B45;\"\u003eHandling and shipment checks\u003c\/h4\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;font-size:1rem;line-height:1.65;box-sizing:border-box;margin:0 0 16px;\"\u003eRead the current HI775S SDS and follow the supplied lot label for storage, PPE and disposal. Use the lot’s expiry date rather than dates shown in product photographs.\u003c\/p\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:400;margin:0 0 16px;color:#245B45;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eIs this the same reagent as marine HI755 or HI772?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. HI775-26 is the freshwater formulation for a 0–500 ppm as CaCO3 method. HI755 is a different marine formulation and HI772 is a different dKH method; do not select reagents by a shared alkalinity name alone.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eDoes an as-CaCO3 reading measure dissolved calcium?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. The result expresses alkalinity on a calcium-carbonate equivalent basis; it is not a calcium concentration or a pH reading. The HI775 manual gives 1 ppm CaCO3 = 0.02 meq\/L = 0.056 dKH as reporting conversions, not different reagent methods.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhich listed photometers have direct method support?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eHI83300, HI83303, HI83326, HI83399, HI97104 and HI971044 explicitly list HI775-26. The HI775 Checker manual also names it. For HI971044, the current MAN971044 11\/25 manual applies to software v1.02 and higher. Use your exact model method and cuvette rather than assuming every Hanna alkalinity program accepts this reagent.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat does the 25-test refill include?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe manufacturer states 25 tests, and the HI775 manual accessory entry explicitly names one syringe and one tip with HI775-26. This is not a complete instrument starter kit. Chlorine remover, photometer, cuvettes and check standards are not represented as included; no total liquid volume is inferred from the 1 mL analytical dose.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eHow is the HI775 measurement prepared?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eZero with 10 mL unreacted sample. Add exactly 1 mL HI775S, cap, gently invert five times and read promptly. Keep the same cuvette orientation and its outside dry and fingerprint-free. Air bubbles or a spilled reagent dose can affect the colorimetric reading.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhen is chlorine remover needed, and which code?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eChlorine interferes. HI775 and HI97104 instruct adding one drop of HI93755-53 when chlorine is present. Exact-model HI971044 names HI937554-53 and includes its one-drop addition in the procedure. Do not silently substitute one code for the other; use the helper specified by your model and confirm it separately.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eCan I leave the reacted sample until later?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. The HI775 manual warns that standing too long after adding reagent affects accuracy. Read promptly and discard the reacted sample immediately after reading to reduce permanent cuvette staining. Rinse and clean according to the instrument instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 400; list-style-position: inside;\"\u003eWhat else should I buy or check before testing?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eConfirm the compatible instrument and model-specific cuvettes\/caps, your dosing syringe\/tip, a clean wipe and the applicable chlorine-removal helper. CAL Check materials verify the instrument but are not analytical reagents. Follow the supplied lot label for storage and expiry; no stock-lot expiry or dispatch date is guaranteed here.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":53468049408298,"sku":"BTS-HI775-26","price":36.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/freshwater-alkalinity-reagents-hi775-26__44741.1695138712.jpg?v=1793900736","url":"https:\/\/bluetigerscientific.com\/products\/hanna-hi775-26-freshwater-alkalinity-reagents-25-tests","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}