{"product_id":"handheld-sodium-chloride-refractometers","title":"VEE GEE Scientific handheld sodium chloride refractometers","description":"\u003cdiv id=\"bts-buying-9806825193770\" style=\"max-width:1050px;line-height:1.65;font-family:Open Sans,sans-serif;font-size:16px;font-weight:400\"\u003e\n\u003cnav aria-label=\"Buying guide navigation\" style=\"display:flex;flex-wrap:wrap;gap:4px 18px;border-bottom:1px solid #B7D0BF;padding:4px 0 12px;\"\u003e\u003ca href=\"#hs-9806825193770-fit\" onclick=\"var e=Array.from(document.querySelectorAll('#hs-9806825193770-fit')).find(function(n){return n.getClientRects().length});if(e){window.scrollBy({top:e.getBoundingClientRect().top-125,behavior:'instant'})};return false\" style=\"color:#245B45;font-size:15px;font-weight:600;text-decoration:underline;padding:6px 0;\"\u003eChoose the configuration\u003c\/a\u003e\u003ca href=\"#hs-9806825193770-pack\" onclick=\"var e=Array.from(document.querySelectorAll('#hs-9806825193770-pack')).find(function(n){return n.getClientRects().length});if(e){window.scrollBy({top:e.getBoundingClientRect().top-125,behavior:'instant'})};return false\" style=\"color:#245B45;font-size:15px;font-weight:600;text-decoration:underline;padding:6px 0;\"\u003ePlan the order\u003c\/a\u003e\u003ca href=\"#bts-spec-9806825193770\" onclick=\"var t=document.querySelector('label[for=\u0026quot;pf-tab-ef5c5c09-1\u0026quot;]');if(t){t.click();setTimeout(function(){var e=Array.from(document.querySelectorAll('#bts-spec-9806825193770')).find(function(n){return n.getClientRects().length});if(e){window.scrollBy({top:e.getBoundingClientRect().top-125,behavior:'instant'})}},120);return false}\" style=\"color:#245B45;font-size:15px;font-weight:600;text-decoration:underline;padding:6px 0;\"\u003eSpecifications\u003c\/a\u003e\u003ca href=\"#bts-hs-brochure-9806825193770-0\" onclick=\"var t=document.querySelector('label[for=\u0026quot;pf-tab-ef5c5c09-3\u0026quot;]');if(t){t.click();setTimeout(function(){var e=Array.from(document.querySelectorAll('#bts-hs-brochure-9806825193770-0')).find(function(n){return n.getClientRects().length});if(e){window.scrollBy({top:e.getBoundingClientRect().top-125,behavior:'instant'})}},120);return false}\" style=\"color:#245B45;font-size:15px;font-weight:600;text-decoration:underline;padding:6px 0;\"\u003eManuals and brochure\u003c\/a\u003e\u003ca href=\"#hs-9806825193770-faq\" onclick=\"var e=Array.from(document.querySelectorAll('#hs-9806825193770-faq')).find(function(n){return n.getClientRects().length});if(e){window.scrollBy({top:e.getBoundingClientRect().top-125,behavior:'instant'})};return false\" style=\"color:#245B45;font-size:15px;font-weight:600;text-decoration:underline;padding:6px 0;\"\u003eBuyer questions\u003c\/a\u003e\u003c\/nav\u003e\n\u003ch2 id=\"hs-9806825193770-fit\" style=\"scroll-margin-top:125px;font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35\"\u003eChoose the scale before choosing the model\u003c\/h2\u003e\n\u003cp style=\"line-height:1.7\"\u003eFor samples around 6% NaCl, both scales cover the concentration, but SX-1 has finer divisions. For a sample around 18%, select SX-2: the concentration is beyond the SX-1 scale. Range, resolution and accuracy belong to the model and cannot be selected separately.\u003c\/p\u003e\n\u003cfigure style=\"margin:16px 0;padding:14px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:10px;\"\u003e\u003cimg alt=\"VEE GEE Scientific handheld sodium chloride refractometers — family illustration\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-HANDHELD-SODIUM-CHLORIDE-REFRACTOMETERS-_1581__70386.1724273478.jpg?v=1749332228\" style=\"display:block;width:100%;max-width:320px;height:auto;max-height:240px;object-fit:contain;margin:auto;\"\u003e\u003cfigcaption\u003eVEE GEE handheld optical refractometer. The range is specific to the selected model.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch3 id=\"hs-9806825193770-pack\" style=\"scroll-margin-top:125px;font-family:Open Sans,sans-serif;font-size:18px;font-weight:600;line-height:1.35\"\u003ePlan the order\u003c\/h3\u003e\n\u003cp style=\"line-height:1.7\"\u003e1 Each. Each pack contains one model. The two instruments have different measurement ranges.\u003c\/p\u003e\n\n\u003ch2 id=\"hs-9806825193770-faq\" style=\"scroll-margin-top:125px;font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35\"\u003eBuyer questions\u003c\/h2\u003e\n\u003cdiv class=\"faq_block\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"line-height:1.7;font-weight:300;color:#333\"\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eAre the readings percent salt or parts per thousand?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThese two scales report sodium chloride as grams per 100 g of sample (% by mass). They are not the seawater specific-gravity or parts-per-thousand models.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich instrument covers concentrations above 10%?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eSX-2 (43035) covers 0–28% NaCl at 0.2% resolution and ±0.2% accuracy. SX-1 (43033) ends at 10%.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs a smaller scale division the same as accuracy?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eResolution is the smallest marked increment; accuracy is the stated tolerance. SX-1 has 0.1% divisions and ±0.1% accuracy. SX-2 has 0.2% divisions and ±0.2% accuracy.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the instrument correct for temperature?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNeither model has automatic temperature compensation. The metal prism housing helps the prism and sample reach equilibrium; the rubber grip reduces warming from your hand. Neither feature supplies ATC.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat does the maximum sample temperature mean?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eHeathrow lists 90°C (194°F) as the maximum sample temperature. It is not a promise of stated accuracy at 90°C. Calibrate according to the model manual at the start of the day and after ambient temperature changes.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat comes with one instrument?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eEach model is sold individually with a zippered vinyl carrying case, plastic transfer pipette and instructions. Heathrow lists a five-year warranty.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow do I read the optical scale?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eWith the sample spread across the prism under the daylight plate, look through the focused eyepiece. Read where the blue and white fields meet the NaCl scale. Use the matching operation manual for calibration and handling.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow should I clean the prism?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eWipe the prism and daylight plate with a soft cloth or tissue moistened with water, then dry. Do not immerse the refractometer or hold it under a running tap; abrasive materials can scratch the optical glass.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Heathrow Scientific","offers":[{"title":"0 to 10% \/ 0.1% \/ ±0.1%","offer_id":50280225276202,"sku":"BTS-43033","price":142.0,"currency_code":"USD","in_stock":true},{"title":"0 to 28% \/ 0.2% \/ ±0.2%","offer_id":50280225341738,"sku":"BTS-43035","price":142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-HANDHELD-SODIUM-CHLORIDE-REFRACTOMETERS-_1581__70386.1724273478.jpg?v=1749332228","url":"https:\/\/bluetigerscientific.com\/products\/handheld-sodium-chloride-refractometers","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}