{"product_id":"handheld-refractive-index-refractometer","title":"Heathrow Scientific Refractive Index Refractometer | 43055","description":"\u003cdiv class=\"bts-heathrow-next20\" style=\"box-sizing:border-box;max-width:1100px;margin:0 auto;padding:12px 0;background:#fff;color:#26332C;font-family:Open Sans,sans-serif;font-size:16px;font-weight:400;line-height:1.7;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eChoose refractive index—not an application conversion\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eRead refractive index from 1.435 to 1.520 nD with the compact NDX-2 optical handheld refractometer.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:28px;margin:24px 0;\"\u003e\n\u003cfigure style=\"box-sizing:border-box;flex:1 1 260px;min-width:0;margin:0;text-align:center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-HANDHELD-REFRACTIVE-INDEX-REFRACTOMETER-43055_1586__11371.1717551487.jpg?v=1749332147\" alt=\"Heathrow Scientific Refractive Index Refractometer | 43055 — Choose refractive index—not an application conversion\" loading=\"lazy\" style=\"display:block;width:360px;max-width:100%;height:auto;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-size:13px;line-height:1.5;color:#59665F;max-width:440px;margin:12px auto 0;\"\u003eManufacturer product view. Illustrated supplies show an application; refer to the stated order unit for the item supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv style=\"flex:1 1 280px;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:Open Sans,sans-serif;font-size:18px;line-height:1.4;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eChoose refractive index—not an application conversion\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eThe NDX-2 presents a direct refractive-index scale for samples that fall within 1.435–1.520 nD. This is a useful distinction when your method calls for nD rather than a Brix, salinity or coolant conversion. Compare your expected result range with both endpoints before ordering; the model does not extend down to the refractive index of pure water.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:28px;margin:24px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:Open Sans,sans-serif;font-size:18px;line-height:1.4;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eAn optical instrument with controlled handling\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eThe high-contrast scale, optical-glass prism and all-metal prism housing support a clear boundary-line reading. The rubber grip limits direct hand heat reaching the body, while the non-roll stand helps keep the instrument in place on a flat bench. Leave time for sample and prism temperatures to settle rather than relying on the grip alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"box-sizing:border-box;flex:1 1 260px;min-width:0;margin:0;text-align:center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-HANDHELD-REFRACTIVE-INDEX-REFRACTOMETER-43055_1585__21078.1717551485.jpg?v=1749332147\" alt=\"Heathrow Scientific Refractive Index Refractometer | 43055 — An optical instrument with controlled handling\" loading=\"lazy\" style=\"display:block;width:360px;max-width:100%;height:auto;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-size:13px;line-height:1.5;color:#59665F;max-width:440px;margin:12px auto 0;\"\u003eManufacturer product view. Illustrated supplies show an application; refer to the stated order unit for the item supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eTemperature correction matters for this model\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eNDX-2 does not have automatic temperature compensation. Its manual calls for calibration at the start of the day and when ambient temperature changes; it also explains correction for water-based solutions and oils. Use the coefficient appropriate to the sample and your method rather than transferring a correction from a different liquid.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eKeep the method beside the instrument\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eThe supplied vinyl case and transfer pipet make a compact bench or field set. The model-specific PDF below includes the calibration procedure and reference information. For broader-range digital nD work, compare a digital Brix\/refractive-index model separately; display style and covered range are different selection questions.\u003c\/p\u003e\n\u003cdiv style=\"box-sizing:border-box;background:#F1F7F3;border-left:4px solid #245B45;padding:20px;margin:28px 0;\"\u003e\n\u003ch3 style=\"font-family:Open Sans,sans-serif;font-size:18px;line-height:1.4;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eConfirm the order unit\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003e43055 — 1 Each. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eRelated choices for your workflow\u003c\/h2\u003e\n\u003cdiv style=\"border-left:3px solid #B7D0BF;padding:2px 0 2px 18px;margin:20px 0;\"\u003e\n\u003ca style=\"color:#245B45;text-decoration:underline;font-weight:600;\" href=\"\/products\/heathrow-scientific-digital-brix-and-refractive-index-refractometers\"\u003eDigital Brix and Refractive Index Refractometers\u003c\/a\u003e\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eCompare digital nD instruments when you need a different range or a numerical display; verify the specific model before choosing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is the NDX-2 range?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003e1.435–1.520 nD, with 0.001 nD resolution and ±0.001 nD stated accuracy.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes it have automatic temperature compensation?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. Use the calibration and temperature-correction guidance in the NDX-2 manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan I use distilled water as the reading-range reference?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003ePure-water nD is below this model’s range. Follow its specified calibration procedure and appropriate standard instead.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan it measure oils?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe manual discusses both water-based solutions and oils, with different temperature-correction considerations.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat helps prevent it rolling on the bench?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe body includes a non-roll stand; place it on a stable, flat surface.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat is supplied?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eOne NDX-2 instrument, vinyl carrying case, transfer pipet and operation manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhen should I check calibration?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe manual calls for calibration at the start of each day and when ambient temperature shifts.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Heathrow Scientific","offers":[{"title":"Default Title","offer_id":50280223277354,"sku":"BTS-43055","price":142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-HANDHELD-REFRACTIVE-INDEX-REFRACTOMETER-43055_1586__11371.1717551487.jpg?v=1749332147","url":"https:\/\/bluetigerscientific.com\/products\/handheld-refractive-index-refractometer","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}