{"product_id":"digital-coolant-refractometer","title":"Heathrow Scientific Digital Coolant Refractometer | 48603","description":"\u003cdiv class=\"bts-heathrow-next20\" style=\"box-sizing:border-box;max-width:1100px;margin:0 auto;padding:12px 0;background:#fff;color:#26332C;font-family:Open Sans,sans-serif;font-size:16px;font-weight:400;line-height:1.7;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eMatch the scale to the coolant\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eMeasure ethylene- or propylene-glycol coolant concentration with the four-scale MDX-603 digital refractometer.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:28px;margin:24px 0;\"\u003e\n\u003cfigure style=\"box-sizing:border-box;flex:1 1 260px;min-width:0;margin:0;text-align:center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-DIGITAL-COOLANT-REFRACTOMETER-48603_1621__39841.1717551580.jpg?v=1749331956\" alt=\"Heathrow Scientific Digital Coolant Refractometer | 48603 — Match the scale to the coolant\" loading=\"lazy\" style=\"display:block;width:360px;max-width:100%;height:auto;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-size:13px;line-height:1.5;color:#59665F;max-width:440px;margin:12px auto 0;\"\u003eManufacturer digital-family photograph from this product page. Screen values and displayed model are illustrative; see the specifications for the supplied model.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv style=\"flex:1 1 280px;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:Open Sans,sans-serif;font-size:18px;line-height:1.4;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eMatch the scale to the coolant\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eThe MDX-603 keeps two coolant chemistries distinct: ethylene glycol and propylene glycol. Select the appropriate chemistry before using its concentration or freezing-point scale. The concentration ranges are 0–65% v\/v for ethylene glycol and 0–73% v\/v for propylene glycol; the wrong chemistry selection is not a substitute for identifying the sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:28px;margin:24px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:Open Sans,sans-serif;font-size:18px;line-height:1.4;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eA compact reading station\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eThe stainless-steel prism well sits beneath a cover, with a removable rubber grip around the handheld body. A digital display avoids interpreting a boundary line through an eyepiece. The 15-read continuous-loop function supports repeated observations of the sample; keep the selected scale and reported units with the result.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"box-sizing:border-box;flex:1 1 260px;min-width:0;margin:0;text-align:center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-DIGITAL-COOLANT-REFRACTOMETER-48603_1620__68950.1717551575.jpg?v=1749331956\" alt=\"Heathrow Scientific Digital Coolant Refractometer | 48603 — A compact reading station\" loading=\"lazy\" style=\"display:block;width:360px;max-width:100%;height:auto;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-size:13px;line-height:1.5;color:#59665F;max-width:440px;margin:12px auto 0;\"\u003eManufacturer digital-family photograph from this product page. Screen values and displayed model are illustrative; see the specifications for the supplied model.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eSet up and check before the sample\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eThe manufacturer specifies zeroing with distilled water and provides a dedicated MDX-603 manual below. Follow that procedure and the temperature-compensation instructions before testing. Concentration resolution is 0.1% with stated accuracy of ±0.5%; resolution is the display increment, not an accuracy guarantee at every operating condition.\u003c\/p\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eChoose the right protection and range\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eThe detecting unit is rated IP67 and the remainder IP65—not a single whole-instrument immersion rating. The case protects the instrument between sessions. Confirm the required freezing-point limits before ordering: the published Celsius and Fahrenheit endpoints are inconsistent, so precise endpoint claims are intentionally withheld here.\u003c\/p\u003e\n\u003cdiv style=\"box-sizing:border-box;background:#F1F7F3;border-left:4px solid #245B45;padding:20px;margin:28px 0;\"\u003e\n\u003ch3 style=\"font-family:Open Sans,sans-serif;font-size:18px;line-height:1.4;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eConfirm the order unit\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003e48603 — 1 Each. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:24px;line-height:1.35;font-weight:600;color:#245B45;margin:30px 0 14px;border-bottom:1px solid #B7D0BF;padding-bottom:10px;\"\u003eRelated choices for your workflow\u003c\/h2\u003e\n\u003cdiv style=\"border-left:3px solid #B7D0BF;padding:2px 0 2px 18px;margin:20px 0;\"\u003e\n\u003ca style=\"color:#245B45;text-decoration:underline;font-weight:600;\" href=\"\/products\/handheld-coolant-battery-acid-refractometers\"\u003eHeathrow Scientific Handheld Coolant \u0026amp; Battery Acid Refractometers\u003c\/a\u003e\u003cp style=\"margin:0 0 16px;line-height:1.7;\"\u003eCompare optical handheld coolant instruments if an eyepiece reading better suits your routine; check their scales independently.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq_block\" style=\"border-top: 1px solid #e0e0e0; margin-top: 40px; padding-top: 20px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333;\"\u003e\n\u003ch3 style=\"font-size: 1.1rem; font-weight: 600; margin: 0 0 16px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat does the MDX-603 measure?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eEthylene-glycol and propylene-glycol concentration, plus a separate freezing-point scale for each coolant.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes one concentration scale cover both coolants?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. Select the scale for the actual coolant chemistry: ethylene glycol or propylene glycol.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat concentration ranges are available?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eEthylene glycol is 0–65% v\/v and propylene glycol is 0–73% v\/v.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow is the instrument zeroed?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe manufacturer specifies distilled water; follow the supplied MDX-603 calibration procedure.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan it take repeated readings?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. Its continuous-loop mode takes 15 readings; use the manual for the operating sequence.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs the entire refractometer rated IP67?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. IP67 applies to the detecting unit; the remainder is rated IP65.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat comes with catalog 48603?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eOne MDX-603 refractometer, rubber grip and prism cover, lined hard case, disposable pipet, battery and manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Heathrow Scientific","offers":[{"title":"Default Title","offer_id":50280218329386,"sku":"BTS-48603","price":485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-DIGITAL-COOLANT-REFRACTOMETER-48603_1621__39841.1717551580.jpg?v=1749331956","url":"https:\/\/bluetigerscientific.com\/products\/digital-coolant-refractometer","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}