{"product_id":"baume-hydrometers","title":"Baumé Hydrometers for Liquids Heavier Than Water","description":"\u003cdiv class=\"bts-h20o-guide\" style=\"max-width:1080px;margin:auto;color:#26332c;font:400 16px\/1.7 Open Sans,sans-serif\"\u003e\n\u003cnav aria-label=\"Buying guide navigation\" style=\"display:flex;flex-wrap:wrap;gap:6px 18px;border-bottom:1px solid #B7D0BF;padding:10px 0;\"\u003e\u003ca href=\"#bts-hs-9806820966698-guide\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806820966698-guide')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eBuying guide\u003c\/a\u003e\u003ca href=\"#bts-hs-9806820966698-fit\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806820966698-fit')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eFit and selection\u003c\/a\u003e\u003ca href=\"#bts-hs-9806820966698-specs\" onclick=\"var t=document.querySelector('label[for=\u0026quot;pf-tab-ef5c5c09-1\u0026quot;]');if(t){t.click();setTimeout(function(){var e=Array.from(document.querySelectorAll('#bts-hs-9806820966698-specs')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});},80);return false;}\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eSpecs\u003c\/a\u003e\u003ca href=\"#bts-hs-9806820966698-faq\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806820966698-faq')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eFAQs\u003c\/a\u003e\u003ca href=\"#bts-order-options\" onclick=\"var e=document.getElementById('bts-order-options');if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eCompare models\u003c\/a\u003e\u003c\/nav\u003e\u003ch2 id=\"bts-hs-9806820966698-guide\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eChoosing a heavy Baumé hydrometer\u003c\/h2\u003e\n\u003cp style=\"line-height:1.7\"\u003eFor a bath or process solution heavier than water, match the expected density range to the marks on the stem. Choose a narrow scale to follow small changes or a wider scale to check several formulations with one instrument.\u003c\/p\u003e\n\u003cfigure style=\"display:flex;align-items:center;flex-wrap:wrap;gap:14px 24px;padding:16px;margin:20px 0;border:1px solid #B7D0BF;border-radius:8px\"\u003e\u003cimg alt=\"VEE GEE heavy Baumé hydrometer with a graduated glass stem and weighted bulb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-BAUME-HYDROMETERS-_1665__12366.1717551758_1bf24804-7a20-4931-ab78-2eeb20c321f6.jpg?v=1795388942\" style=\"width:150px;height:300px;max-width:100%;object-fit:contain\"\u003e\u003cfigcaption style=\"flex:1 1 210px\"\u003eThe family photograph shows the 0–50 °Bé stem and weighted bulb. Other ranges have different markings; select by the catalog number and division below.\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-BAUME-HYDROMETERS-_1665__12366.1717551758_1bf24804-7a20-4931-ab78-2eeb20c321f6.jpg?v=1795388942\" rel=\"noopener\" style=\"color:#245b45;text-decoration:underline\" target=\"_blank\"\u003eOpen the full-resolution 0–50 °Bé photograph\u003c\/a\u003e\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch2 id=\"bts-hs-9806820966698-fit\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eRange, resolution and sample fit\u003c\/h2\u003e\n\u003ch3 style=\"font:600 18px\/1.4 Open Sans,sans-serif;color:#245b45\"\u003eSmall changes near a set point\u003c\/h3\u003e\n\u003cp style=\"font:400 16px\/1.7 Open Sans,sans-serif\"\u003eFor a bath normally between 10 and 20 °Bé, 6609-2 spans 9–21 °Bé in 0.1 °Bé divisions. Model 6609-9 spans 0–25 °Bé in 0.2 °Bé divisions: it adds room below the working range but has fewer marks per degree. A division is the spacing on the scale, not a statement of accuracy.\u003c\/p\u003e\n\u003ch3 style=\"font:600 18px\/1.4 Open Sans,sans-serif;color:#245b45\"\u003eOne scale for several formulations\u003c\/h3\u003e\n\u003cp style=\"font:400 16px\/1.7 Open Sans,sans-serif\"\u003eIf samples can reach 45 °Bé, 6609-11 covers 0–50 °Bé in 0.5 °Bé divisions. If readings stay between 39 and 51 °Bé, 6609-5 gives finer 0.1 °Bé marks. For a process that can exceed 70 °Bé, 6609-15 extends to 90 °Bé in 1 °Bé steps.\u003c\/p\u003e\n\u003ch2 id=\"bts-hs-9806820966698-faq\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eBuyer FAQs\u003c\/h2\u003e\n\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"line-height:1.7;font-weight:300;color:#333\"\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs this the right scale for my liquid?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eUse the heavy Baumé scale when the sample is denser than water and your method calls for °Bé. A light Baumé hydrometer uses a different scale for liquids lighter than water; the two are not interchangeable.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs Baumé the same as Brix or specific gravity?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eNo. The stem reads °Bé, not percent sugar or specific gravity. Brix expresses sucrose concentration for sucrose–water solutions. For the heavy Baumé convention used here, the manufacturer gives specific gravity = 145 ÷ (145 − °Bé). Use the convention and reference temperature specified by your method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich model should I use for readings near 30 °Bé?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eFor readings between 29 and 41 °Bé, 6609-4 has 0.1 °Bé divisions. If samples may be well below 29 °Bé, 6609-10 spans 0–35 °Bé, with coarser 0.5 °Bé divisions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat reference temperature should I use?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eVEE GEE specifies 60 °F (approximately 15 °C) for this series. Check sample temperature separately. If it differs from the reference, follow the temperature correction prescribed by your method rather than treating the observed reading as corrected.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow do I take a reading?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eLower the hydrometer gently into a suitable jar. It should float clear of the bottom and sides, with no bubbles clinging to the bulb. Let the liquid settle, then read at eye level using the meniscus convention your method specifies.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich jar or storage case fits?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eVEE GEE pairs the 305 mm 6609 series with hydrometer jar 21050-500 and protective case 66CS-13. The jar must allow the hydrometer to float freely. Neither accessory is included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat comes in one pack?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eOne glass hydrometer with the range and division listed beside its catalog number. A broad-range model is one instrument, not a set of narrower-range instruments. Inspect the glass before use and set aside any instrument with a chip or crack.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Heathrow Scientific","offers":[{"title":"0 to 12°","offer_id":50280219279658,"sku":"BTS-6609-1","price":31.0,"currency_code":"USD","in_stock":true},{"title":"9 to 21°","offer_id":50280219312426,"sku":"BTS-6609-2","price":31.0,"currency_code":"USD","in_stock":true},{"title":"19 to 31°","offer_id":50280219345194,"sku":"BTS-6609-3","price":31.0,"currency_code":"USD","in_stock":true},{"title":"29 to 41°","offer_id":50280219377962,"sku":"BTS-6609-4","price":31.0,"currency_code":"USD","in_stock":true},{"title":"39 to 51°","offer_id":50280219410730,"sku":"BTS-6609-5","price":31.0,"currency_code":"USD","in_stock":true},{"title":"49 to 61°","offer_id":50280219443498,"sku":"BTS-6609-6","price":27.0,"currency_code":"USD","in_stock":false},{"title":"59 to 71°","offer_id":50280219476266,"sku":"BTS-6609-7","price":27.0,"currency_code":"USD","in_stock":false},{"title":"0 to 15°","offer_id":50280219509034,"sku":"BTS-6609-8","price":31.0,"currency_code":"USD","in_stock":true},{"title":"0 to 25°","offer_id":50280219541802,"sku":"BTS-6609-9","price":31.0,"currency_code":"USD","in_stock":true},{"title":"0 to 35°","offer_id":50280219574570,"sku":"BTS-6609-10","price":31.0,"currency_code":"USD","in_stock":true},{"title":"0 to 50°","offer_id":50280219607338,"sku":"BTS-6609-11","price":31.0,"currency_code":"USD","in_stock":true},{"title":"35 to 70°","offer_id":50280219640106,"sku":"BTS-6609-12","price":31.0,"currency_code":"USD","in_stock":true},{"title":"0 to 70°","offer_id":50280219672874,"sku":"BTS-6609-14","price":31.0,"currency_code":"USD","in_stock":true},{"title":"0 to 90°","offer_id":50280219705642,"sku":"BTS-6609-15","price":51.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-BAUME-HYDROMETERS-_1665__12366.1717551758_1bf24804-7a20-4931-ab78-2eeb20c321f6.jpg?v=1795388942","url":"https:\/\/bluetigerscientific.com\/products\/baume-hydrometers","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}