{"product_id":"armored-encapsulated-glass-thermometers","title":"Armored Encapsulated Glass Thermometers","description":"\u003cdiv class=\"bts-h20o-guide\" style=\"max-width:1080px;margin:auto;color:#26332c;font:400 16px\/1.7 Open Sans,sans-serif\"\u003e\n\u003cnav aria-label=\"Buying guide navigation\" style=\"display:flex;flex-wrap:wrap;gap:6px 18px;border-bottom:1px solid #B7D0BF;padding:10px 0;\"\u003e\u003ca href=\"#bts-hs-9806831517994-guide\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806831517994-guide')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eBuying guide\u003c\/a\u003e\u003ca href=\"#bts-hs-9806831517994-fit\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806831517994-fit')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eFit and selection\u003c\/a\u003e\u003ca href=\"#bts-hs-9806831517994-specs\" onclick=\"var t=document.querySelector('label[for=\u0026quot;pf-tab-ef5c5c09-1\u0026quot;]');if(t){t.click();setTimeout(function(){var e=Array.from(document.querySelectorAll('#bts-hs-9806831517994-specs')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});},80);return false;}\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eSpecs\u003c\/a\u003e\u003ca href=\"#bts-hs-9806831517994-faq\" onclick=\"var e=Array.from(document.querySelectorAll('#bts-hs-9806831517994-faq')).find(function(n){return n.getClientRects().length});if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eFAQs\u003c\/a\u003e\u003ca href=\"#bts-order-options\" onclick=\"var e=document.getElementById('bts-order-options');if(e)e.scrollIntoView({block:'start'});return false;\" style=\"color:#245B45;text-decoration:underline;padding:6px 0;\"\u003eCompare models\u003c\/a\u003e\u003c\/nav\u003e\u003ch2 id=\"bts-hs-9806831517994-guide\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eWhen to specify both armor and encapsulation\u003c\/h2\u003e\n\u003cp style=\"line-height:1.7\"\u003eWhen a thermometer moves between a rack and a bath, its metal guard helps protect the glass from knocks. Inside the nickel-plated brass guard, an FEP coating is designed to retain fragments and fill if the glass breaks. Neither feature determines how deeply to immerse the stem: that choice depends on the method.\u003c\/p\u003e\n\u003cfigure style=\"display:flex;align-items:center;flex-wrap:wrap;gap:14px 24px;padding:16px;margin:20px 0;border:1px solid #B7D0BF;border-radius:8px\"\u003e\u003cimg alt=\"Representative VEE GEE armored, FEP-encapsulated thermometer shown full length\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/VEE-GEE-Scientific-Products-ARMORED-ENCAPSULATED-GLASS-THERMOMETERS-_1625__07979.1717551589.jpg?v=1749332741\" style=\"width:200px;height:auto;max-width:100%;object-fit:contain\"\u003e\u003cfigcaption style=\"flex:1 1 210px\"\u003eRepresentative photograph of the armored, FEP-encapsulated family. Use the model row—not the photographed markings—to choose the scale and immersion type.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003ch2 id=\"bts-hs-9806831517994-fit\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eMatch the immersion mark and the vessel\u003c\/h2\u003e\n\u003ch3 style=\"font:600 18px\/1.4 Open Sans,sans-serif;color:#245b45\"\u003eSame range, different working depth\u003c\/h3\u003e\n\u003cp style=\"font:400 16px\/1.7 Open Sans,sans-serif\"\u003eFor a −20 to 110°C bath, 80707E-A and 80907E-A both have 1°C marks. Use the total-immersion 80707E-A when the procedure immerses the bulb and liquid column up to the reading. Choose 80907E-A when the bath surface must meet the partial-immersion line.\u003c\/p\u003e\n\u003ch3 style=\"font:600 18px\/1.4 Open Sans,sans-serif;color:#245b45\"\u003eAllow room for the longer Fahrenheit pair\u003c\/h3\u003e\n\u003cp style=\"font:400 16px\/1.7 Open Sans,sans-serif\"\u003eThe 30 to 220°F models are 15.38 inches long, compared with 12 inches for the other ranges. Check clearance around the vessel and clamp before choosing 80704E-A or 80904E-A. Overall length is not a specified immersion depth.\u003c\/p\u003e\n\u003ch2 id=\"bts-hs-9806831517994-faq\" style=\"font-family:Open Sans,sans-serif;font-size:24px;font-weight:600;line-height:1.35;color:#245B45;scroll-margin-top:125px;border-bottom:1px solid #B7D0BF;padding-bottom:8px\"\u003eBuyer FAQs\u003c\/h2\u003e\n\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"line-height:1.7;font-weight:300;color:#333\"\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat does the FEP coating do if the thermometer breaks?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eThe coating is designed to retain the glass fragments and liquid fill. It does not make the instrument unbreakable. If damage is suspected, remove it from service and follow your facility’s procedure for handling the instrument and any affected sample.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan I substitute a partial-immersion model with the same range?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eNot on the basis of range alone. Total immersion and partial immersion place different lengths of the liquid column in the medium. Match the designation in the method; for a partial-immersion instrument, look for the line on the actual stem.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich models cover readings below −20°C?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003e80706E-A (total) and 80906E-A (partial) reach −35°C, but stop at 50°C. The −20 to 110°C and −20 to 150°C pairs reach higher temperatures, but neither covers the colder interval.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich Fahrenheit model fits a 30 to 220°F procedure?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eChoose 80704E-A for total immersion or 80904E-A for partial immersion. Both have 2°F divisions and a 15.38-inch overall length. If clearance is limited, do not assume that a shorter model with an overlapping range meets the procedure.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs each thermometer marked in both Celsius and Fahrenheit?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eNo. The catalog number specifies one scale: 1°C divisions on the Celsius models or 2°F divisions on the Fahrenheit models. Select the units your procedure records. The family photograph is not a scale reference for every model.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes a serial number establish calibration?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eThe serial number identifies the individual instrument in your equipment log. It does not, by itself, supply calibration results or a certificate. Confirm any required certificate, test points or traceability before ordering.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow do E-A, E and -A differ on a purchase order?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;;font-weight:300\"\u003eE-A specifies both the FEP coating and nickel-plated brass armor. E alone denotes encapsulation without armor; -A alone denotes armor without encapsulation. Order one thermometer per unit and include the full catalog number, not just the range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Heathrow Scientific","offers":[{"title":"-30 to 120°F \/ 2°F \/ Total","offer_id":50280234713386,"sku":"BTS-80701E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"-30 to 120°F \/ 2°F \/ Partial","offer_id":53720545558826,"sku":"BTS-80901E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"-4 to 230°F \/ 2°F \/ Total","offer_id":50280234811690,"sku":"BTS-80702E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"-4 to 230°F \/ 2°F \/ Partial","offer_id":53720545591594,"sku":"BTS-80902E-A","price":77.0,"currency_code":"USD","in_stock":false},{"title":"0 to 300°F \/ 2°F \/ Total","offer_id":50280234877226,"sku":"BTS-80703E-A","price":77.0,"currency_code":"USD","in_stock":false},{"title":"0 to 300°F \/ 2°F \/ Partial","offer_id":53720545624362,"sku":"BTS-80903E-A","price":77.0,"currency_code":"USD","in_stock":false},{"title":"30 to 220°F \/ 2°F \/ Total","offer_id":50280234942762,"sku":"BTS-80704E-A","price":95.0,"currency_code":"USD","in_stock":true},{"title":"30 to 220°F \/ 2°F \/ Partial","offer_id":53720545657130,"sku":"BTS-80904E-A","price":95.0,"currency_code":"USD","in_stock":false},{"title":"-35 to 50°C \/ 1°C \/ Total","offer_id":50280234975530,"sku":"BTS-80706E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"-35 to 50°C \/ 1°C \/ Partial","offer_id":53720545689898,"sku":"BTS-80906E-A","price":77.0,"currency_code":"USD","in_stock":false},{"title":"-20 to 110°C \/ 1°C \/ Total","offer_id":50280235041066,"sku":"BTS-80707E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"-20 to 110°C \/ 1°C \/ Partial","offer_id":53720545722666,"sku":"BTS-80907E-A","price":77.0,"currency_code":"USD","in_stock":false},{"title":"-20 to 150°C \/ 1°C \/ Total","offer_id":50280235106602,"sku":"BTS-80708E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"-20 to 150°C \/ 1°C \/ Partial","offer_id":53720545755434,"sku":"BTS-80908E-A","price":77.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/armored-fep-thermometer-full.jpg?v=1795478528","url":"https:\/\/bluetigerscientific.com\/products\/armored-encapsulated-glass-thermometers","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}