{"product_id":"apera-ph850-dp-value-portable-liquid-food-protein-ph-meter-kit","title":"Apera PH850-DP Portable pH Meter Kit with LabSen 823 pH\/Temperature Electrode","description":"\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\" id=\"bts-ph850-dp-description\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ PH850-DP \/ AI5535\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eProtein-containing liquids.\u003cbr\u003eA reference built for the task.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003ePH850-DP combines the PH850 Value-series portable meter with the refillable LabSen 823 pH\/temperature electrode. Its silver-ion-trap reference, three ceramic junctions and Protelyte electrolyte suit dairy products, compatible liquid foods and selected protein-containing laboratory samples.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eChoose DP when the reference chemistry matters as much as the displayed pH. The electrode is designed to reduce protein-related junction problems, not eliminate cleaning or certify a formulation. Establish suitability for your sample composition and work within the complete measurement system’s temperature limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Apera PH850-DP with LabSen 823 electrode\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:340px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eExact PH850-DP manufacturer photograph with LabSen 823. Display values are demonstration graphics, not a sample result.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-850value-kit-guide\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;margin:24px 0;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;border-radius:10px;cursor:pointer;line-height:1.5;\"\u003e\u003cspan style=\"flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;\"\u003eWhich 850 Value kit fits my sample?\u003c\/span\u003e\u003cspan class=\"bts-sp-when-closed\" style=\"display:block;font-size:.88rem;margin-top:5px;\"\u003eClick or tap to compare all nine configurations, including harsh-chemistry kits\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\" style=\"font-size:.88rem;\"\u003eClick or tap here to close the guide\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"bts-sp-toggle\" aria-hidden=\"true\" style=\"flex:0 0 38px;width:38px;height:38px;display:flex;align-items:center;justify-content:center;border-radius:50%;background:white;font-size:27px;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eEach card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-SS\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-ss-value-portable-food-semi-solid-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-ss-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=200\" alt=\"Apera PH850-SS\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-SS\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5543\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eFood and semi-solids\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 753 spear; prepared sacrificial samples.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-SS →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-MT\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-mt-value-portable-meat-blade-spear-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-mt-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=200\" alt=\"Apera PH850-MT\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-MT\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5545\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eMeat sampling\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 763 blade-spear; a controlled preparation method.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-MT →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-DP\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-dp-value-portable-liquid-food-protein-ph-meter-kit\" aria-current=\"page\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=200\" alt=\"Apera PH850-DP\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-DP\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5535\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eProtein-containing and liquid-food samples\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eRefillable LabSen 823 with specified Protelyte care.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-BR\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-br-value-portable-beverage-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-br-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=200\" alt=\"Apera PH850-BR\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-BR\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5533\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eBeverage making\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 213 glass electrode with 3M KCl care.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-BR →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-SL\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-sl-value-portable-soil-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-sl-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=200\" alt=\"Apera PH850-SL\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-SL\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5537\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003ePrepared moist soil\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 553; direct and slurry methods stay distinct.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-SL →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-FT\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-ft-value-portable-flat-surface-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-ft-hero-20261016-value850-special.webp?v=1792155330\u0026amp;width=200\" alt=\"Apera PH850-FT\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-FT\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5560\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eWet flat surfaces\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 373; wet the sensing glass and junction.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-FT →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.78rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:24px 0 12px;padding-bottom:6px;border-bottom:2px solid #B7D0BF;\"\u003eHarsh-chemistry kits\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-HF\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-hf-value-portable-strong-acid-hf-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-hf-hero-20261017-harsh.webp?width=200\" alt=\"Apera PH850-HF\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-HF\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5529\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eStrong acid \u0026amp; HF\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 833: HF-type glass, ceramic junction.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-HF →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-SA\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-sa-value-portable-strong-alkali-high-salinity-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-sa-hero-20261017-harsh.webp?width=200\" alt=\"Apera PH850-SA\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-SA\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5527\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eStrong alkali \u0026amp; high salinity\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 843: HA (high-alkali) glass, ceramic junction.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-SA →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003ca class=\"bts-850value-kit-link\" data-850value-kit=\"PH850-HT\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-ht-value-portable-high-temperature-caustic-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-ht-hero-20261017-harsh.webp?width=200\" alt=\"Apera PH850-HT\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH850-HT\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5564\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eHot, complex \u0026amp; caustic liquids\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 863: PHY glass, PTFE ring junction.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH850-HT →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eChoose the electrode for the sample.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eReference chemistry for protein-containing samples\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 823 uses Protelyte around a silver-ion-trap reference and three ceramic junctions. This combination targets reference contamination and clogging in suitable protein-containing liquids. It remains a refillable, serviceable electrode: residue must be removed and electrolyte maintained. The blue inner gel is distinct from the outer reference solution you replenish.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eTemperature measured at the probe\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 823 incorporates an NTC 30 kΩ temperature sensor. The meter displays temperature alongside pH and supports automatic compensation. This corrects the electrode response, not the sample’s chemistry. A warm sample can genuinely differ from the same sample after cooling, so report temperature with pH.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003ePortable controls without a software workflow\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe LCD provides a stability symbol and completed-calibration indicators. A protective sleeve, fold-out stand and IP57 instrument enclosure support portable use. Automatic buffer recognition and selectable stability criteria help standardize operation, while the operator remains responsible for calibration quality, clean connections and a separate record of each result.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eKnow what this configuration supplies.\u003c\/h2\u003e\n\u003cdiv aria-label=\"Included item table\" role=\"region\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;overflow-x:auto;width:100%;max-width:100%;\" tabindex=\"0\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;border-collapse:collapse;font-size:1rem;border:1px solid #e0e0e0;table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eIncluded item\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOrder contents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003ePH850 Value-series meter\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOne instrument in the PH850-DP specialty configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eLabSen 823 pH\/temperature electrode\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eRefillable glass electrode with BNC\/RCA connections; replacement AI3153.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eCarrying case\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eShown and named in the exact specialty-kit manufacturer illustration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eCalibration solutions\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003epH 4.00, 7.00 and 10.01 bottles shown; specialty-kit volumes not confirmed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eProtelyte soaking solution\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eNamed as Protelyte in the DP kit illustration; exact bottle volume not confirmed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eManual and screwdriver\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eBoth named in the exact specialty-kit illustration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eElectrode storage bottle\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eWet-storage bottle\/cap shown in electrode instructions. Battery inclusion remains unconfirmed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-kit-case-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-kit-case-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-kit-case-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-kit-case-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"PH850-DP specialty kit in its carrying case\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eCase view cropped from the exact PH850-DP manufacturer kit illustration. The accessory list is repeated in the kit contents; bottle volumes and battery inclusion are unconfirmed.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eMatch the sample and preparation method.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eDairy and compatible liquid foods\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse a defined sampling method for milk, cream, yogurt and suitable sauces or other liquid foods. Ensure the sensing glass and junctions are properly immersed. Thick or heterogeneous samples may need a validated preparation procedure; the round glass tip is not intended to puncture solid food.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eProtein-containing laboratory liquids\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eConsider the 823 configuration for compatible biological fluids, enzyme solutions and protein-containing preparations. Review the entire matrix, including cleaners and solvents, before use. Suitability for these applications does not make the kit a sterile instrument, a diagnostic test or a release-testing compliance system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eTRIS-buffered aqueous preparations\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe manufacturer identifies the 823 reference system and Protelyte for compatible TRIS applications. That is not blanket compatibility with every concentration, additive or temperature. Use appropriate calibration and method controls for the actual preparation, and investigate persistent drift rather than treating it as a finished result.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sample-method-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sample-method-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sample-method-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sample-method-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Prepare. Calibrate. Measure.\" width=\"1200\" height=\"1260\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eUse a consistent sample preparation and temperature routine. Connect, calibrate and wait for a stable result; there is no universal reading time.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003ePrepare a representative sample.\u003cbr\u003eRead only after stabilization.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eConnect the blue BNC plug for pH and the black RCA plug for temperature. Remove the storage bottle, rinse the sensing end with distilled or deionized water, and open the blue refill plug so electrolyte can flow. Inspect the reference level before starting. A newly connected LabSen 823 requires at least a two-point calibration before measurement.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe PH850 recognizes USA or NIST buffers and supports one to three calibration points. In USA mode, begin with pH 7.00 and add suitable points for the expected sample range. Use fresh portions of buffer and rinse between solutions. Do not pour used buffer back into its bottle; a displayed calibration indicator cannot establish that a contaminated standard was valid.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFor dairy and protein samples, maintain a consistent collection, mixing and immersion procedure without striking the vessel with the glass tip. Use sufficient sample to cover the membrane and all junctions. Let temperature and pH stabilize and watch the stability symbol. No fixed sample volume or universal reading time is promised; characterize the response in your own matrix.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eUnderstand the sensing end and connections.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-probe-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-probe-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-probe-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-probe-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"LabSen 823 lead-free glass refillable pH and temperature electrode\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eThe exact supplied electrode type, LabSen 823. Full manufacturer probe view retained; the cable continues beyond the source photograph.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sensing-end-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sensing-end-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sensing-end-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-sensing-end-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"LabSen 823 hemispherical sensing end and ceramic junction detail\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eActual LabSen 823 sensing-end photograph. Rinse away sample residues and protect the glass membrane from impact. Portrait source is proportionally contained on white.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"ph850-dp-feature-combined-ph-temperature\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-combined-ph-temperature-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-combined-ph-temperature-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-combined-ph-temperature-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-combined-ph-temperature-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"LabSen 823 schematic comparing conventional and combined pH and temperature sensing structures\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eManufacturer schematic with a LabSen 823 tip photograph. The left diagrams show conventional temperature-sensor arrangements; the right diagram shows the LabSen combined pH and temperature structure, with the temperature sensor near the sensing tip. This explains sensor placement, not a promised response time. Automatic temperature compensation does not control the sample temperature.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"ph850-dp-feature-silver-ion-trap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-silver-ion-trap-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-silver-ion-trap-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-silver-ion-trap-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-silver-ion-trap-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"LabSen 823 reference insert illustration with AgCl and silver-ion-trap labels\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eManufacturer reference-component illustration, not a photograph of the complete LabSen 823 probe. AgCl means silver chloride; Silver-ion-trap identifies the separate trapping material below it. The 823 uses this reference system with Protelyte and three ceramic junctions. Those three junctions are not shown in this insert view. Routine cleaning is still necessary; the illustration does not mean the probe cannot clog.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eProtelyte inside.\u003cbr\u003eProtelyte for storage.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eWhen the reference solution falls to about half the electrode height, refill through the opening with Protelyte AI1190. The exact LabSen 823 instructions specify Protelyte for both reference refill and external soaking. Do not substitute generic KCl merely because it is used with other pH electrodes.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRinse sample residue from the electrode before and after use. Return it to the storage bottle containing clean Protelyte, tighten the cap and close the refill plug. Replace contaminated or insufficient solution. Pure water is appropriate for rinsing, not long-term storage. Keep the BNC and RCA connectors clean and dry even though the instrument itself has an IP57 rating.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFor tough contamination, the exact electrode manual specifies Apera AI1166 cleaner for 30 minutes, gentle removal with a soft brush, then at least one hour in Protelyte. Rinse and recalibrate before measuring again. Do not scrape the glass membrane. The electrode manual advises avoiding strong acids, strong alkalis and dehydrating media such as absolute ethanol. Do not assume compatibility from the stated pH range alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-refill-port-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-refill-port-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-refill-port-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-refill-port-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Blue refill plug and LabSen 823 model marking\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eClose crop of the reference refill plug and original LabSen 823 label. Open the plug for measurement; replenish with Protelyte at about half reference height.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-care-workflow-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-care-workflow-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-care-workflow-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-care-workflow-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Protelyte reference refill and wet storage guide\" width=\"1200\" height=\"1260\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 823 requires Protelyte for both refill and wet storage. The inner blue gel is not the reference solution being replenished.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"ph850-dp-feature-inner-blue-gel\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-inner-blue-gel-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-inner-blue-gel-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-inner-blue-gel-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-inner-blue-gel-sourcegraphic-20261016.webp?v=1792159264\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"LabSen 823 manufacturer illustration comparing blue inner sensing gel with conventional inner solution\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eManufacturer comparison illustration with probe-tip photographs and a central schematic. Blue Gel Inner Solution identifies the gel inside the sensing element; Conventional Inner Solution identifies the comparison at right. The arrows depict convection and bubble formation. This inner gel is not the refillable outer reference liquid. For LabSen 823, use Protelyte AI1190 for both reference refill and wet storage.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-fold-out-stand-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-fold-out-stand-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-fold-out-stand-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-fold-out-stand-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Actual PH850 meter with its fold-out support stand\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eMeter-only PH850 manufacturer view, also applicable to this PH850 kit. The stand supports tabletop positioning; keep electrical connections dry.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-controls-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-controls-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-controls-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-controls-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"PH850 front controls, screen and original model label\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eMeter-only crop of the actual PH850. Calibration, mode and setup controls are visible; the displayed pH is an illustrative manufacturer graphic.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"ph850-dp-feature-lcd-annotations\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-lcd-annotations-sourcegraphic-20261016.webp?v=1792159265\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-lcd-annotations-sourcegraphic-20261016.webp?v=1792159265\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-lcd-annotations-sourcegraphic-20261016.webp?v=1792159265\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-ph850-dp-feature-lcd-annotations-sourcegraphic-20261016.webp?v=1792159265\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"PH850 display diagram with numbered stability, calibration and temperature indicators\" width=\"1000\" height=\"1000\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eManufacturer display illustration, not a live sample reading. 1 marks the smiley stability icon; 2 marks the L, M and H completed-calibration indicators; 3 marks the simultaneous temperature reading. HOLD locks the displayed reading temporarily. It does not save a measurement record.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eA stable reading is the start of the record.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse the physical controls for on-meter measurement and calibration. HOLD temporarily locks a reading on screen; write the result and its sample context in your external worksheet or record system. Screen values in photographs are illustrative, not sample results.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse calibration solutions and settings appropriate to the parameter and fitted electrode. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eA readable result, not a stored sample record.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003ePH850 is a direct-reading Value-series instrument. Its current specification lists reading storage, storage content and output as N\/A. Choose a separate recordkeeping method before starting a sample series; this meter does not supply stored-reading recall or a computer export workflow.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eOptional automatic HOLD freezes a stable reading on the display. It helps with transcription but does not save the sample or create a timestamped entry. Record sample identity, pH, measured temperature, operator and your own date and time while the result is still associated with the correct vessel.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRetain buffer details, calibration checks and electrode-care observations alongside the sample result. For work governed by a quality procedure, use the organization’s approved worksheet and acceptance rules. The kit does not itself establish traceability, food safety, pharmaceutical release status or regulatory compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-manual-record-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-manual-record-20261016-value850-special.webp?v=1792155330\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-manual-record-20261016-value850-special.webp?v=1792155330\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-manual-record-20261016-value850-special.webp?v=1792155330\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"PH850 manual recordkeeping guide\" width=\"1200\" height=\"1260\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003ePH850 has no specified reading memory or output. Use a separate worksheet or notebook; HOLD does not create a saved sample record.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCompare the Premium Series counterpart.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAlternative format: \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph8500-dp-portable-liquid-food-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera PH8500-DP Portable pH Meter Kit with LabSen 823 Electrode\u003c\/a\u003e. The Premium Series counterpart offers a different recordkeeping workflow and kit specification. Compare the exact supplied electrode, accessories and data features rather than assuming similar model names mean identical hardware or software.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\" id=\"bts-ph850-dp-faq\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003ePH850-DP buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhich electrode is supplied, and what is the replacement SKU?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe current US PH850-DP kit specifies LabSen 823, catalog AI3153. It combines pH and temperature sensing with BNC and RCA plugs. This is the 823 configuration, not a general-purpose electrode with a different storage requirement.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhich refill and storage solution do I need?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eUse Protelyte for both reference refill and external wet storage. LabSen 823’s current manual specifies AI1190. Generic KCl is not the prescribed substitute for this probe.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat is actually in the specialty kit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe model-specific manufacturer illustration lists the PH850, LabSen 823, carrying case, manual, screwdriver, pH 4.00\/7.00\/10.01 buffers and Protelyte soaking solution. Exact bottle volumes and battery inclusion are not confirmed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan I use it with all protein or TRIS samples?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The 823 is intended for suitable protein-containing and TRIS-buffered liquids, but additives, solvent content, viscosity and temperature still matter. Confirm the sample method; the design does not guarantee freedom from clogging or interference.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat range and accuracy should I expect?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe meter spans 0 to 14 pH with selectable 0.01 or 0.1 pH resolution and stated accuracy of ±0.01 pH ±1 digit. The supplied electrode also spans 0 to 14 pH. These specifications do not guarantee the same uncertainty in every sample or method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWill HOLD or the meter save my results?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. HOLD only freezes the display. Reading memory and output are N\/A for PH850, so write down the sample identity, pH, temperature and your own timestamp. No data-download workflow is included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhich batteries does this version require?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eConfirm the supplied revision before purchasing replacements: the current US product page says three AA batteries, while the PH850 manual specifies three AAA. Battery inclusion is not established by those power specifications.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat warranty applies to this kit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe current US page and PH850 manual specify a three-year limited instrument warranty and six months for the probe, from delivery. Coverage is for qualifying defects; accidental damage, misuse, normal wear, improper storage and other listed exclusions are not covered.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReview PH850-DP AI5535 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":52967304364330,"sku":"BTS-AI5535","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph850-dp-hero-20261016-value850-special.webp?v=1792155330","url":"https:\/\/bluetigerscientific.com\/products\/apera-ph850-dp-value-portable-liquid-food-protein-ph-meter-kit","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}