{"product_id":"apera-ph820-benchtop-ph-meter-kit","title":"Apera PH820 Precision Benchtop pH Meter Kit | AI531","description":"\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\" id=\"bts-ph820-description\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ PH820 \/ AI531\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eA finer pH display, with separate control of temperature sensing\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003ePH820 combines selectable 0.001 pH resolution with a refillable LabSen 211 glass electrode and a separate MP500 temperature probe. Its five-point calibration capability, slope feedback and clear status display suit laboratory methods that need a more detailed pH reading and deliberate electrode care.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFor general aqueous laboratory pH work where finer display resolution and a refillable reference are useful. Instrument accuracy is specified as ±0.002 pH ±1 digit; this is not an unconditional accuracy guarantee for every sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Apera PH820 with LabSen 211 and separate MP500 temperature probe\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:340px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eExact PH820 manufacturer photograph showing two separate probes in one sample. Display values are illustrative and the beaker is not listed as a kit item.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-800-kit-guide\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;margin:24px 0;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;border-radius:10px;cursor:pointer;line-height:1.5;\"\u003e\u003cspan style=\"flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;\"\u003eWhich 800 or 820 benchtop kit fits my work?\u003c\/span\u003e\u003cspan class=\"bts-sp-when-closed\" style=\"display:block;font-size:.88rem;margin-top:5px;\"\u003eClick or tap to compare all six benchtop configurations\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\" style=\"font-size:.88rem;\"\u003eClick or tap here to close the guide\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"bts-sp-toggle\" aria-hidden=\"true\" style=\"flex:0 0 38px;width:38px;height:38px;display:flex;align-items:center;justify-content:center;border-radius:50%;background:white;font-size:27px;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eEach card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-800-kit-link\" data-800-kit=\"PH800\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph800-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph800-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=200\" alt=\"Apera PH800\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH800\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI521\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eStandard benchtop pH\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e201T-F combined pH\/temperature electrode.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH800 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-800-kit-link\" data-800-kit=\"EC800\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec800-benchtop-conductivity-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec800-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=200\" alt=\"Apera EC800\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003eEC800\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI522\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eStandard benchtop conductivity\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e2301T-F plastic conductivity\/temperature electrode.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView EC800 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-800-kit-link\" data-800-kit=\"PC800\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc800-benchtop-ph-conductivity-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-pc800-pc800-front-20261016-benchtop800.webp?v=1792161763\u0026amp;width=200\" alt=\"Apera PC800\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePC800\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI523\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eStandard pH and conductivity kit\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eSeparate 201T-F and 2301T-F electrodes; sequential modes.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PC800 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-800-kit-link\" data-800-kit=\"PH820\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph820-benchtop-ph-meter-kit\" aria-current=\"page\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=200\" alt=\"Apera PH820\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH820\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI531\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003ePrecision benchtop pH\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 211 plus separate MP500 temperature probe.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-800-kit-link\" data-800-kit=\"EC820\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec820-benchtop-conductivity-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec820-hero-20261016-benchtop800.webp?v=1792161763\u0026amp;width=200\" alt=\"Apera EC820\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003eEC820\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI532\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003ePrecision benchtop conductivity\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e2401T-F glass conductivity\/temperature electrode.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView EC820 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-800-kit-link\" data-800-kit=\"PC820\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc820-benchtop-ph-conductivity-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-pc820-pc820-conductivity-setup-20261016-benchtop800.webp?v=1792161763\u0026amp;width=200\" alt=\"Apera PC820\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePC820\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI533\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003ePrecision pH and conductivity kit\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 211, MP500 and 2401T-F; sequential modes.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PC820 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eChoose the electrode for the sample.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eA precision meter is one part of the method\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003ePH820’s specified instrument accuracy is ±0.002 pH ±1 digit across its -2.000 to 19.999 pH display range. Resolution is selectable down to 0.001 pH. Achieving useful sample results also requires suitable buffers, a clean electrode, thermal equilibration and a controlled procedure; extra digits alone do not establish measurement uncertainty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eTwo probes with different jobs\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 211 is a pH-only electrode connected by BNC. MP500 is a separate stainless-steel temperature probe with an RCA plug and 30 kΩ thermistor. Place both in the same solution for automatic temperature compensation. The phrase combination electrode refers to pH measuring and reference elements, not a built-in temperature sensor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eRefillable reference and a glass sensing tip\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 211 uses an S-type hemispherical membrane, a ceramic junction and a long-life reference system. The manufacturer’s reference graphic identifies AgCl, meaning silver chloride, inside the reference assembly. The blue inner gel and the outer 3M KCl refill solution have different roles. The glass remains fragile and the reference requires maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eChoose the calibration mode deliberately\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe instrument offers one to three points in 3P mode and one to five in 5P mode. USA and NIST series are supported; the manual also describes a separate one- or two-point custom calibration mode. Selecting five-point capability does not add two extra buffers to the supplied three-bottle kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eStatus information beside the result\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe LCD combines the reading with temperature, stability, calibration and storage indicators. ATC identifies automatic compensation; MTC identifies manual input. M+ indicates saving and RM indicates recall. The stable-reading icon and optional auto-lock help standardize when you record a result, but neither proves that an unsuitable sample is being measured correctly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eKnow what this configuration supplies.\u003c\/h2\u003e\n\u003cdiv aria-label=\"Included item table\" role=\"region\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;overflow-x:auto;width:100%;max-width:100%;\" tabindex=\"0\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;border-collapse:collapse;font-size:1rem;border:1px solid #e0e0e0;table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eIncluded item\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOrder contents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003ePH820 precision benchtop meter\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOne instrument, US kit SKU AI531.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eLabSen 211 pH electrode\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eRefillable glass, BNC pH-only connection, storage bottle.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eMP500 temperature probe\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eSeparate stainless-steel temperature sensor with RCA plug.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003epH calibration buffers\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003epH 4.00, 7.00 and 10.01; the linked manual lists 50 mL each.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eFlexible electrode holder\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eSupports the probes over the sample vessel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eUSB cable and PC-Link media\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eCurrent page lists a flash drive; legacy manual lists a software disk. Check revision and compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003ePower adapter\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eUS input 120 V AC, 60 Hz; output 9 V DC, 300 mA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eInstructions and manual-listed care items\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eThe linked configuration table also lists a quick guide, 50 mL 3M KCl and a pipette; confirm these smaller items with the supplied revision. Beaker and computer imagery is illustrative.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-bench-configuration-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-bench-configuration-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-bench-configuration-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-bench-configuration-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Front view of PH820 with flexible holder and both probes\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eThe flexible holder supports the glass pH electrode and stainless-steel temperature probe together. It is not a magnetic stirrer; refer to the kit list for accessories.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eMatch the sample and preparation method.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eGeneral aqueous laboratory samples\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse the supplied LabSen 211 for compatible water-based solutions and routine laboratory analysis with a defined method. Its 0 to 14 pH electrode range is narrower than the meter display range. Select a specialty electrode for strongly aggressive or unusual matrices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eTRIS-buffer work\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe exact LabSen 211 instructions state compatibility with TRIS buffers. Keep reference electrolyte at the recommended level and open the refill plug while measuring. Compatibility does not remove the need for clean junctions, fresh calibration buffers and a documented temperature procedure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eBeverage method development\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe series manual lists LabSen 211 among electrodes for beverage, beer and wine analysis. Control sample preparation, temperature and cleaning between runs. Do not extend that recommendation to puncturing solids, thick dairy products or oily emulsions without an application-specific electrode and validated method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-mp500-20261016-benchtop800.webp?v=1792161763\u0026amp;width=750\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-mp500-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-mp500-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-mp500-20261016-benchtop800.webp?v=1792161763\u0026amp;width=750 750w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"MP500 stainless-steel temperature probe and RCA connector\" width=\"750\" height=\"750\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eMP500 supplies the separate temperature input. Its -10 to 110°C probe rating does not establish the meter’s full-system range; the linked PH820 manual specifies 0 to 100°C.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCalibrate the electrode and measure temperature in the same solution\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eConnect LabSen 211 to the pH BNC input and MP500 to the temperature RCA input. Remove the storage bottle carefully, rinse the sensing end, and open the blue refill plug so reference electrolyte can flow. Support both probes with the holder without pressing their tips against the vessel. The probe manual requires at least two calibration points when connecting a new electrode.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse fresh portions of appropriate buffer in clean vessels, not the stock bottles. Rinse between solutions, remove excess rinse water without rubbing the sensing glass, and allow the electrode and solution to reach a stable temperature. A buffer’s actual pH changes with temperature; select the correct buffer series rather than treating every bottle labelled neutral as interchangeable.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eSelect USA or NIST buffers and the required 3P or 5P mode before calibration. In the standard three-point sequence, begin at pH 7.00, then use 4.00 and 10.01 as appropriate. Wait for recognition and a stable indication before confirming. Extra pH 1.68 and 12.45 buffers are not part of the listed starter set.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFor samples, immerse both probes adequately and let them equilibrate together. Brief gentle movement can release bubbles; then allow the reading to settle. Temperature compensation corrects the pH electrode’s response, not the sample’s own temperature-dependent chemistry. The manual’s custom-buffer procedure requires calibration and measurement at the same temperature, so use it only within an established method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eUnderstand the sensing end and connections.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-labsen211-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-labsen211-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-labsen211-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-labsen211-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"LabSen 211 refillable glass pH electrode\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 211 is the supplied pH-only electrode. Its BNC connection does not carry temperature; use the separate MP500 for automatic compensation.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensing-tip-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensing-tip-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensing-tip-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensing-tip-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"LabSen 211 hemispherical blue sensing tip close-up\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eActual LabSen 211 tip photograph, tightly cropped to show the glass sensing end. The blue inner gel is distinct from the outer 3M KCl reference solution used for refill.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"reference-system\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-reference-system-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-reference-system-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-reference-system-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-reference-system-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Manufacturer long-life reference construction illustration labelled AgCl\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal manufacturer reference-assembly illustration, not a view of the whole probe. AgCl means silver chloride. The design supports a stable reference; it does not guarantee a fixed service life or eliminate refill and cleaning.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"sensor-construction\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensor-construction-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensor-construction-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensor-construction-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-sensor-construction-20261016-benchtop800.webp?v=1792161763\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Original LabSen glass sensor construction and materials panel\" width=\"1600\" height=\"1600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal manufacturer panel illustrating glass-sensor fabrication and design priorities. Low membrane resistance concerns electrical response, not resistance to all chemicals. These are design descriptions, not an independent accuracy or breakage guarantee.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eManage the refillable reference, not just the outside of the probe\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eWhen the reference solution falls to about half the electrode height, replenish it with 3M KCl, AI1107, through the refill opening using a clean pipette or syringe. Do not confuse this outer reference solution with the sealed blue inner gel. Close the refill plug after use, and return the electrode to its storage bottle.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eSoak the sensing end in 3M KCl storage solution, replacing contaminated liquid. Never store the electrode in distilled or deionized water. Rinse with purified water before and after testing. For persistent deposits, the exact probe manual describes Apera AI1166 cleaner followed by KCl conditioning and recalibration; choose cleaning compatible with the sample residue.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAvoid prolonged exposure to strong acids, strong alkalis and dehydrating media. The LabSen manual lists -5 to 100°C, while the US probe page gives an inconsistent lower-limit conversion; confirm any subzero application. Keep connectors dry and protect the glass from impact. IP54 protects the meter against splashes and dust, not immersion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"refill-and-connector\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-refill-and-connector-20261016-benchtop800.webp?v=1792161763\u0026amp;width=700\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-refill-and-connector-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-refill-and-connector-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-refill-and-connector-20261016-benchtop800.webp?v=1792161763\u0026amp;width=700 700w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Original LabSen 211 manual labels for refill plug and BNC connector\" width=\"700\" height=\"680\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal labelled manual photograph: the blue rubber plug covers the refill opening; the BNC connector carries pH. Open the refill plug during measurement and close it after use.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"storage-anatomy\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-storage-anatomy-20261016-benchtop800.webp?v=1792161763\u0026amp;width=515\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-storage-anatomy-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-storage-anatomy-20261016-benchtop800.webp?v=1792161763\u0026amp;width=515 515w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Original LabSen 211 manual labels for measuring tip and storage bottle\" width=\"515\" height=\"550\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal manual detail labels the storage-bottle cap, measuring tip and storage bottle. Keep the tip and junction in 3M KCl when not in use; pure water is for rinsing, not storage.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"lcd-symbols\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-lcd-symbols-20261016-benchtop800.webp?v=1792161763\u0026amp;width=710\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-lcd-symbols-20261016-benchtop800.webp?v=1792161763\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-lcd-symbols-20261016-benchtop800.webp?v=1792161763\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-lcd-symbols-20261016-benchtop800.webp?v=1792161763\u0026amp;width=710 710w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Original 820 Series numbered LCD status schematic\" width=\"710\" height=\"575\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal series-manual LCD schematic, not a measurement photograph. 1 parameter; 2 reading; 3 USB connection; 4 timed storage; 5-6 date\/time; 7 measurement unit; 8 calibration unit; 9 calibration value or record number; 10 temperature unit; 11 M+ save or RM recall; 12 temperature; 13 ATC automatic or MTC manual compensation; 14 completed calibration; 15 HOLD; 16 stable reading. Conductivity legends belong to other series models, not this pH meter.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRead the display. Check the measurement mode.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse calibration solutions and settings appropriate to the parameter and fitted electrode. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eSave readings, but confirm the memory and software revision\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe current PH820 specification table says 1,000 groups, but the same page’s description and the linked 820 manual say 500 for PH820. The manual assigns 1,000 groups to PC820. Because this contradiction is unresolved, plan on the documented 500-group workflow unless the supplied unit’s capacity is confirmed; do not assume 1,000.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe linked instrument manual documents a legacy Windows PC-Link program, USB driver and COM-port workflow, with export to an Excel file. The current US kit page also advertises browser-based PC-Link. These are different software generations: confirm support for the delivered meter revision, operating system, browser and required export fields before committing to a computer workflow. No software installation or runtime compatibility test is implied here.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe legacy manual records record number, date, time, measurement, unit and temperature, with manual or timed saving. Its connected real-time mode sends readings to the PC rather than storing them internally. Check the clock, retain sample identifiers separately, and back up exported records before clearing memory. Newer browser reporting fields require confirmation for the delivered revision.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCompare a TestBench benchtop alternative.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAlternative format: \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph9500-benchtop-ph-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera PH9500 Benchtop pH Meter Kit with LabSen 211 and 606 TestBench\u003c\/a\u003e. The linked TestBench model has a different bench arrangement, record workflow and kit specification. Compare the exact supplied electrode, accessories and data features rather than assuming similar model names mean identical hardware or software.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\" id=\"bts-ph820-faq\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003ePH820 buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eDoes LabSen 211 measure temperature?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. It is a pH-only BNC electrode. This kit includes the separate MP500 temperature probe for the RCA input. Both probes must experience the same solution temperature for a consistent ATC workflow.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eDoes 0.001 pH resolution mean ±0.001 pH accuracy?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Resolution is the displayed increment. PH820 instrument accuracy is specified as ±0.002 pH ±1 digit, and complete sample uncertainty also includes electrode, buffer, temperature and method effects.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs memory 500 or 1,000 groups?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe manufacturer’s current page conflicts internally. Its table says 1,000; its description and linked manual say 500 for PH820. Confirm the supplied revision before relying on more than 500 groups.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan I use the full meter range with this probe?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. LabSen 211 is specified for 0 to 14 pH. The wider -2.000 to 19.999 meter display range does not extend the electrode’s chemical or temperature suitability.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs the temperature range -10 to 110°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThat is the MP500 probe range and the current kit-page temperature figure. The linked meter manual lists 0 to 100°C. Do not treat the probe rating as confirmed full-system capability outside the meter’s documented range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWill the USB software run on my current computer?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eConfirm compatibility first. The manual describes a legacy Windows-only program, while the current kit page also advertises browser-based PC-Link. Neither description establishes tested compatibility with every host or meter revision.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eAre ORP, conductivity or stirring included?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eAn appropriate ORP electrode is sold separately for mV work. PH820 does not provide conductivity measurement, and the flexible holder is not a magnetic stirrer. No printer or computer is included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat warranty applies?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eApera’s current US instrument manual provides a three-year limited warranty for the instrument and six months for the probe, measured from delivery, for defects attributable to Apera. Repair or replacement is at Apera’s option. Exclusions include accidental damage, transportation, storage, improper use, failure to follow instructions or preventive maintenance, unauthorized repair and normal wear. See the linked manual for the complete terms.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReview PH820 AI531 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":52967966900522,"sku":"BTS-AI531","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph820-hero-20261016-benchtop800.webp?v=1792161763","url":"https:\/\/bluetigerscientific.com\/products\/apera-ph820-benchtop-ph-meter-kit","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}