{"product_id":"apera-ph700-pw-benchtop-ph-meter-kit","title":"Apera PH700-PW Benchtop pH Meter Kit with LabSen 803 Pure-Water Electrode","description":"\u003cdiv id=\"bts-ph700-pw-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ PH700-PW \/ AI5015\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eLow-ion water deserves a different reference junction.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe PH700-PW pairs a fixed bench station with the refillable LabSen 803 pH\/temperature electrode. Its low-resistance membrane and movable sleeve junction address the difficult electrical conditions of pure water, where a rushed reading can undermine a careful test.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eChoose AI5015 for suitable distilled, deionized, RO and other low-ionic-strength water samples. This is a sample-specific electrode choice, not a conductivity meter or a certificate of water purity. The method, handling and exposure to air remain part of the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"PH700-PW meter with supplied LabSen 803 electrode and simple holder\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-hero-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-hero-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-hero-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-hero-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:340px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eExact specialist configuration. Buffers and adapter are included but not laid out in this photograph.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-ph700-kit-guide\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;margin:24px 0;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;border-radius:10px;cursor:pointer;line-height:1.5;\"\u003e\u003cspan style=\"flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;\"\u003eWhich bench pH configuration fits my sample?\u003c\/span\u003e\u003cspan class=\"bts-sp-when-closed\" style=\"display:block;font-size:.88rem;margin-top:5px;\"\u003eClick or tap to compare kits and the base replacement probe\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\" style=\"font-size:.88rem;\"\u003eClick or tap here to close the guide\u003c\/span\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"bts-sp-toggle\" style=\"flex:0 0 38px;width:38px;height:38px;display:flex;align-items:center;justify-content:center;border-radius:50%;background:white;font-size:27px;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eEach card opens that product page. Different kits supply different probes and care methods. The 201T-F card is an electrode-only base-kit replacement, not an extra specialty electrode supplied with these kits.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-ph700-kit-link\" data-ph700-kit=\"PH700\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg alt=\"Apera PH700\" height=\"72\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-ph700-hero-20261014.png?v=1792014687\u0026amp;width=200\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\" width=\"72\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH700\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI501\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eGeneral-water base kit\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e201T-F BNC\/RCA probe; different from the specialty configurations.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH700 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-ph700-kit-link\" data-ph700-kit=\"PH700-BC\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-bc-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg alt=\"Apera PH700-BC\" height=\"72\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-bc-hero-20261014.webp?v=1792025761\u0026amp;width=200\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\" width=\"72\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH700-BC\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5018\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eProtein \/ TRIS \/ biotech\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 823; Protelyte refill and storage.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH700-BC →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-ph700-kit-link\" data-ph700-kit=\"PH700-WW\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-ww-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg alt=\"Apera PH700-WW\" height=\"72\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-ww-hero-20261014.webp?v=1792025761\u0026amp;width=200\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\" width=\"72\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH700-WW\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5012\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eDirty liquids \/ suspensions\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 333; nonrefillable polymer and KCl storage.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH700-WW →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca aria-current=\"page\" class=\"bts-ph700-kit-link\" data-ph700-kit=\"PH700-PW\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-pw-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg alt=\"Apera PH700-PW\" height=\"72\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-hero-20261014.webp?v=1792025761\u0026amp;width=200\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\" width=\"72\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH700-PW\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5015\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003ePure \/ low-ionic water\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 803; movable sleeve and defined pure-water method.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-ph700-kit-link\" data-ph700-kit=\"PH700-VS\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-vs-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg alt=\"Apera PH700-VS\" height=\"72\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-vs-hero-20261014.webp?v=1792025761\u0026amp;width=200\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\" width=\"72\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH700-VS\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5016\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eViscous formulations\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 853-H; sealed pre-pressurized reference.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH700-VS →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-ph700-kit-link\" data-ph700-kit=\"PH700-MS\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-ms-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg alt=\"Apera PH700-MS\" height=\"72\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-ms-hero-20261014.webp?v=1792025761\u0026amp;width=200\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\" width=\"72\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH700-MS\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5017\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003ePrecious small samples\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 241-3SP; micro-container and manual-temperature method.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH700-MS →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-ph700-kit-link\" data-ph700-kit=\"201T-F\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-201t-f-replacement-ph-temperature-electrode\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg alt=\"Apera 201T-F\" height=\"72\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-201t-f-hero-20261014.webp?v=1792025761\u0026amp;width=200\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\" width=\"72\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003e201T-F\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI1302\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eREPLACEMENT ELECTRODE ONLY\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eCompatible base PH700 sensor; not a complete meter kit.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView 201T-F →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eChoose the right configuration.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eA junction with adjustable flow\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe movable sleeve lets reference electrolyte flow into the sample through an adjustable contact. Low-ion water requires adequate outflow; follow the electrode instructions for adjustment and recalibrate afterward. The sleeve is a serviceable part, not a promise that maintenance disappears.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eA membrane selected for low-ion water\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe L-type glass membrane has a stated resistance below 50 MΩ. Together with the silver-ion-trap reference, it is designed for this demanding water application. Sampling and air exposure still affect results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eTemperature at the same sensing assembly\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe included 803 combines pH and an NTC 30 kΩ temperature sensor. Connect both leads for automatic compensation. Its specified working range is pH 1-11 and 0-80°C; the meter’s wider display range does not extend the electrode’s limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eKnow exactly what is supplied.\u003c\/h2\u003e\n\u003cdiv aria-label=\"Included item table\" role=\"region\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;overflow-x:auto;width:100%;max-width:100%;\" tabindex=\"0\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;border-collapse:collapse;font-size:1rem;border:1px solid #e0e0e0;table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eIncluded item\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOrder contents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003ePH700 benchtop meter\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOne adapter-powered instrument.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eLabSen 803 pH\/temperature electrode\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOne glass electrode with integrated temperature sensing and BNC\/RCA leads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eCalibration buffers\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003epH 4.00, 7.00 and 10.01; one 50 mL bottle of each.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eElectrode holder\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOne simple metal-base, support-bar and clip set; mounts on either side.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e9V power adapter\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOne adapter; confirm site power requirements before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eUser manual\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eExact-kit instructions for setup, operation and care.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eWhere this configuration fits.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eDistilled and deionized water\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse clean sampling equipment and a defined low-ion measurement procedure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eRO water checks\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCompare like-for-like samples with consistent temperature, handling and exposure to air.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eLow-ionic-strength aqueous solutions\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAssess compatibility and the actual method before treating a reading as a release criterion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Pure-water workflow: at least 250 mL, minimize air exposure and wait for stability\" decoding=\"async\" height=\"1120\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-method-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-method-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-method-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-method-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eKit-specific method overview, not a substitute for the full conditioning and calibration instructions.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eProtect the sample while the reading settles.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003ePrepare at least 250 mL of sample for the pure-water procedure in the PH700-PW manual. Calibrate with suitable fresh standards and follow the manual’s pH 4.00 conditioning and subsequent rinsing sequence. Probe size does not establish micro-volume capability.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe exact kit procedure gives a typical stabilization time of 2-5 minutes. Wait for a genuinely stable reading rather than recording at a fixed countdown. Limit air exposure before and during measurement, using a covered arrangement where practical; carbon dioxide can change low-buffering water while it sits.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eKeep collection, temperature and exposure conditions consistent between tests. Do not add salts just to make an unmodified-water reading behave, or adjust the result until it reaches pH 7. Additions change the sample and belong only in a separately validated method. No covered vessel is supplied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eA closer look at the supplied sensor.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:26px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"LabSen 803 full glass-body pH and temperature electrode\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-probe-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-probe-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-probe-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-probe-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eIncluded LabSen 803. One electrode is supplied; the photograph does not show the complete kit.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"LabSen 803 sensing tip and movable sleeve junction close-up\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-sleeve-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-sleeve-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-sleeve-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-sleeve-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eMovable sleeve detail. Follow the electrode manual for adjustment and recalibrate afterward.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRefill the reference. Preserve the hydrated tip.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eOpen the blue fill-hole stopper for calibration and measurement, then close it for storage. The reference is refillable with 3M KCl. The electrode instructions call for replenishment when the level falls to half the electrode height; use the exact manual for handling and sleeve service.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRinse between standards and samples without rubbing the glass membrane. If deposits remain, use contaminant-appropriate manufacturer cleaning guidance, followed by the required conditioning and recalibration. Check response and calibration behavior, not just the displayed decimal.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eStore the sensing tip and junction in the tightly closed vial with the specified 3M KCl solution. Distilled, DI and RO water are useful for rinsing, not storage. Keep connectors clean and dry. A storage vial is not a separately supplied retail bottle of refill or storage solution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"LabSen 803 refill, stopper and 3M KCl storage care overview\" decoding=\"async\" height=\"1120\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-care-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-care-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-care-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-care-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eRefill the 803 reference as directed; store the hydrated sensing end in 3M KCl.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"PH700 display and CAL, MODE\/SETUP, MAX\/MIN and M+\/RM controls\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-front-controls-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-front-controls-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-front-controls-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-front-controls-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:390px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eShared PH700 controls. The displayed reading is illustrative; M+\/RM saves and recalls local records manually.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eBench electronics, local records.\u003cbr\u003eNot a computer-export workflow.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003ePH700 supports 1-3 pH calibration points and 50 manually saved sets shared across pH\/mV. The instrument display range is 0-14.00 pH with selectable 0.01\/0.1 pH resolution and stated ±0.01 pH ±1 digit accuracy; these do not establish unrestricted probe\/matrix accuracy.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eM+ saves a stable result and RM recalls it. No documented USB\/PC export, automatic interval recording, date\/time field or certified audit trail is promised. Optional ORP needs a separate appropriate ORP electrode; the supplied pH electrode in mV mode gives its pH signal, not ORP.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Blue BNC pH connector and black RCA temperature connector on LabSen 803\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-connectors-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-connectors-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-connectors-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-connectors-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eBoth leads belong to the included pH\/temperature electrode: blue BNC to pH\/mV, black RCA to TEMP.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eMake the connector and temperature arrangement explicit.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse this exact kit’s configuration and sensor guidance. Mechanical connector fit alone does not establish complete electrical, temperature or sample compatibility. The micro-volume configuration differs from the integrated-temperature kits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eSignal processing is one part of the method.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThis manufacturer electronics illustration refers to the PH700 instrument. Appropriate electrode selection, calibration and sample handling still govern the result. It does not establish extra logging\/export features or a separately tested performance guarantee.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"PH700 electronics illustration with electrode, calibration and sample-method reminders\" decoding=\"async\" height=\"1120\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-electronics-20261014.webp?v=1792025761\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-electronics-20261014.webp?v=1792025761\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-electronics-20261014.webp?v=1792025761\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-electronics-20261014.webp?v=1792025761\u0026amp;width=1000 1000w\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eManufacturer electronics illustration with method context. Chip design does not guarantee a stable result for every sample.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"bts-ph700-pw-faq\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003ePH700-PW buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhy use a specialty electrode for pure water?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eLow ionic strength can make junction potentials and electrical response difficult to stabilize. The 803’s low-resistance membrane and flowing sleeve junction address that application, but careful sampling and calibration are still necessary.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eShould every pure-water sample read pH 7?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Temperature, dissolved carbon dioxide and trace contamination affect the measured sample. pH 7 is not a universal acceptance target for every distilled, DI or RO sample, and a pH reading alone does not prove purity or safety.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow much water is needed?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe exact PH700-PW manual specifies at least 250 mL for its pure-water procedure. Do not infer micro-volume capability from the probe diameter or use a smaller aliquot without a validated alternative method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs a reading guaranteed in one minute?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The kit-specific pure-water instructions say stabilization typically takes 2-5 minutes. Actual behavior depends on the sample and handling, and prolonged air exposure can itself change pH.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eDoes this kit need a separate temperature probe?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The included LabSen 803 has integrated temperature sensing. Its blue BNC lead carries pH and the black RCA lead connects to TEMP for automatic compensation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan I refill the LabSen 803?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes, its reference reservoir uses 3M KCl. This differs from sealed gel-reference electrodes. Follow the electrode manual and recalibrate whenever the sleeve tightness is adjusted.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs this the LabSen 813 configuration?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. AI5015 includes LabSen 803. It does not include an 813, a flow cell or a dedicated ultrapure-water validation system. Choose by the required method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eAre all the bench accessories pictured included?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe confirmed kit includes the meter, one 803, three buffers, one holder, adapter and manual. Beakers, stirrers, closed sampling equipment and separate cleaning or KCl bottles are not promised.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact item before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReview PH700-PW AI5015 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":52943230632234,"sku":"BTS-AI5015","price":480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph700-pw-hero-20261014.webp?v=1792025761","url":"https:\/\/bluetigerscientific.com\/products\/apera-ph700-pw-benchtop-ph-meter-kit","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}