{"product_id":"apera-labsen-881-ph-electrode-low-temperature","title":"Apera LabSen 881 Refillable pH Electrode for Low-Temperature Solutions down to −25°C, BNC","description":"\u003cdiv id=\"bts-labsen-881-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ LABSEN 881 \/ AI3149\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003epH down to −25°C.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 881 is a refillable glass pH electrode made for low-temperature solutions, rated from −25 to 80°C. Its special L-type low-resistance conical membrane keeps the response fast in the cold, and its Protelyte reference electrolyte remains usable down to −25°C. It has a BNC connector.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eIt reads pH 1 to 11 from −25 to 80°C. Catalog AI3149. Apera warrants LabSen electrodes for six months from delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 881 pH electrode\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eApera LabSen 881.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-labsen-general-selector\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;padding:0;margin:24px 0;background:#fff;overflow:visible;\"\u003e\u003csummary aria-label=\"Compare LabSen pH electrodes for general water, wastewater, flat surfaces, pure water and cold samples. Expand or collapse the guide.\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:center;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;cursor:pointer;border-radius:10px;font-weight:600;line-height:1.5;\"\u003e\u003cspan style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:block;flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;line-height:1.35;\"\u003eChoose your LabSen electrode: water and lab\u003c\/span\u003e\u003cspan style=\"display:block;font-size:.88rem;font-weight:400;line-height:1.55;margin-top:5px;\"\u003e\u003cspan class=\"bts-sp-when-closed\"\u003eClick or tap to compare 7 electrode families\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\"\u003eCompare the models below - click or tap here to close\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"bts-sp-toggle\" style=\"display:flex;align-items:center;justify-content:center;flex:0 0 38px;width:38px;height:38px;border:1px solid rgba(23,43,77,.35);border-radius:50%;background:#fff;color:#172b4d;font-size:27px;font-weight:400;line-height:1;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cp class=\"bts-guide-availability\" style=\"font-family:'Open Sans',sans-serif;font-size:15px;line-height:1.6;color:#26332C;margin:12px 0;\"\u003eOnly published products are linked. Other cards provide model-comparison information and do not indicate current storefront availability.\u003c\/p\u003e\n\u003cdiv class=\"bts-sp-selector-inner\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:300;line-height:1.65;margin:0 0 18px;color:#26332C;\"\u003eStart with your sample. Each card opens an electrode family; on that page, pick BNC, BNC\/RCA pH\/temperature or 8-pin to match your meter.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-211-213-ph-electrode-general-water-tris\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 211 · 213\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-211-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 211 · 213\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3101 \/ AI3121\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eGeneral water, TRIS buffers\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eRefillable everyday glass electrode; BNC or BNC\/RCA pH\/temp.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 211 · 213 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-221-223-ph-electrode-titration-low-ionic-strength\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 221 · 223\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-221-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 221 · 223\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3102 \/ AI3123\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eTitration, low ionic strength\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eMovable sleeve junction: easy to clean, adjustable flow.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 221 · 223 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-231-ph-electrode-wastewater-glass\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 231\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 231\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3111\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eWastewater, suspensions\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eGlass body, open junction and polymer electrolyte.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 231 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-331-333-335-ph-electrode-wastewater-pom\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 331 · 333 · 335\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-331-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 331 · 333 · 335\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3131 \/ AI3133 \/ AI3231\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eWastewater, harsh environments\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eCorrosion-resistant POM body, open junction; BNC, BNC\/RCA or 8-pin.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 331 · 333 · 335 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-link\" data-labsen-family=\"371\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-371-373-ph-electrode-flat-surface\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera LabSen 371 · 373\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-371-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 371 · 373\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3107 \/ AI3172\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eSkin, textiles, paper, leather\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eFlat glass membrane and PTFE ring junction.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 371 · 373 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-labsen-family-link\" data-labsen-family=\"801\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-801-803-805-ph-electrode-pure-water\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera LabSen 801 · 803 · 805\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 801 · 803 · 805\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3108 \/ AI3137 \/ AI3233\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003ePure, DI and RO water\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eL-type low-resistance glass (\u0026lt;50 MΩ) for low-ionic water.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 801 · 803 · 805 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003cdiv aria-current=\"page\" class=\"bts-labsen-family-link\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:default;\"\u003e\n\u003cimg alt=\"Apera LabSen 881\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 881\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3149\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eCold samples to −25°C\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eL-type conical glass and Protelyte for −25 to 80°C.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;background:#F1F7F3;color:#5D6C63;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the connector.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 881 uses a BNC pH connection and has no built-in temperature sensor. Its −25–80°C rating is an electrode rating, not a promise that the connected meter or temperature probe covers that range. Apera’s MP500 is rated only −10–110°C and cannot cover the 881’s −25°C endpoint. For colder samples, verify a compatible temperature sensor and the host’s ATC range for the actual temperature, or use an independently measured temperature only where the host explicitly supports manual compensation at that temperature. Manual entry does not override a host limit; no replacement sensor is implied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 881 pH electrode\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-tip-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-tip-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-tip-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-tip-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 881.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eWhat makes it work.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eL-type conical membrane\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eSpecial low-resistance glass for low-temperature testing, with fast response.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eProtelyte reference electrolyte\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUsable down to −25°C, where an aqueous KCl reference would struggle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eSilver ion trap + triple ceramic\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe silver ion trap reference system with Protelyte reduces junction clogs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the specifications.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eKey figures: pH range 1–11; temperature range −25–80°C; body lead-free glass; glass membrane L-type, conical; junction ceramic × 3; reference electrolyte Protelyte.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe full specification table is in the Product Specifications tab.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 881 dimension drawing\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-dims-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-dims-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-dims-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-dims-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:460px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 881 dimensions, from Apera.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eStore it wet.\u003cbr\u003eKeep it clean.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eKeep the electrode wet in \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-protelyte-ph-electrode-storage-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera Protelyte storage solution\u003c\/a\u003e when it is not in use.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eNever store a pH electrode in pure, deionized or distilled water.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eIt is refillable: keep the fill hole open while measuring and top up the reference electrolyte when the level drops.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRinse with distilled or deionized water between samples. For stubborn deposits, use \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-electrode-cleaning-solution-ph-conductivity\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera electrode cleaning solution\u003c\/a\u003e, then recondition and recalibrate.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRelated items.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCalibrate with fresh \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-7-00-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 7.00\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-4-00-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 4.00\u003c\/a\u003e and \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-10-01-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 10.01\u003c\/a\u003e buffers.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-labsen-881-faq\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eLabSen 881 buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat is the LabSen 881 made for?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eLabSen 881 is a refillable glass pH electrode made for low-temperature solutions, rated from −25 to 80°C.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs it refillable?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes. Refill LabSen 881 with Protelyte and keep its fill hole open during measurement. Protelyte is also the specified storage and reconditioning solution; do not substitute generic 3M KCl care instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow should I store it?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eKeep the electrode wet in Apera Protelyte storage solution when it is not in use. Never use pure, deionized or distilled water.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan an Apera MP500 measure the full LabSen 881 temperature range?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. LabSen 881 (AI3149; BTS-AI3149) is rated −25–80°C, but MP500 is rated only −10–110°C. MP500 is not a full-range temperature solution for this electrode’s cold endpoint.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWill manual temperature entry let any BNC meter work at −25°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Check the host’s supported manual-compensation range and operating limits. A BNC pH connection alone does not establish low-temperature ATC or MTC support; the method must use a valid sample temperature within the host’s limits.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat pH range and sensing design does LabSen 881 use?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe current US specification is pH 1–11 with an L-type conical membrane, impedance below 50 MΩ, triple ceramic junctions and a silver ion trap reference system. The listed body size is Ø12 × 120 mm.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhy does the European LabSen 881 manual mention −30°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThat is a regional-document rating. This US-market offer retains the narrower −25–80°C range and pH 1–11 from the current US page; the linked English manual is useful for care, not permission to expand the supplied electrode or host rating.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat warranty applies?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eApera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCheck the connector and catalog number (AI3149) against your meter and samples, then return to the live price and ordering controls.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":53008522379562,"sku":"BTS-AI3149","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?v=1792339895","url":"https:\/\/bluetigerscientific.com\/products\/apera-labsen-881-ph-electrode-low-temperature","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}