{"product_id":"apera-labsen-801-803-805-ph-electrode-pure-water","title":"Apera LabSen 801 \/ 803 \/ 805 pH Electrode for Pure Water and Low Ionic Strength Solutions","description":"\u003cdiv id=\"bts-labsen-801-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ LABSEN 801 · 803 · 805 \/ AI3108 \/ AI3137 \/ AI3233\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003ePure water barely conducts.\u003cbr\u003eThis glass is built for it.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 801, 803 and 805 measure pH in pure water such as distilled, deionized and RO water and other low ionic strength solutions, where ordinary electrodes drift. All three use Apera’s L-type low-resistance glass (\u0026lt;50 MΩ) and read pH 1–11. The 801 (BNC) and 803 (BNC\/RCA with temperature) are refillable with a movable sleeve junction; the 805 is the non-refillable 8-pin version with triple ceramic junctions for the PH60 and PH60Z testers.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eIt reads pH 1 to 11 from 0 to 80°C. Choose the version that matches your meter’s connector from the menu above. Apera warrants LabSen electrodes for six months from delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 801 · 803 · 805 pH electrode\" decoding=\"async\" height=\"633\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-main-20261018-mfr.webp?width=633\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-main-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-main-20261018-mfr.webp?width=633 633w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"633\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eApera LabSen 801 · 803 · 805.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-labsen-general-selector\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;padding:0;margin:24px 0;background:#fff;overflow:visible;\"\u003e\u003csummary aria-label=\"Compare LabSen pH electrodes for general water, wastewater, flat surfaces, pure water and cold samples. Expand or collapse the guide.\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:center;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;cursor:pointer;border-radius:10px;font-weight:600;line-height:1.5;\"\u003e\u003cspan style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:block;flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;line-height:1.35;\"\u003eChoose your LabSen electrode: water and lab\u003c\/span\u003e\u003cspan style=\"display:block;font-size:.88rem;font-weight:400;line-height:1.55;margin-top:5px;\"\u003e\u003cspan class=\"bts-sp-when-closed\"\u003eClick or tap to compare 7 electrode families\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\"\u003eChoose an item below - click or tap here to close\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"bts-sp-toggle\" style=\"display:flex;align-items:center;justify-content:center;flex:0 0 38px;width:38px;height:38px;border:1px solid rgba(23,43,77,.35);border-radius:50%;background:#fff;color:#172b4d;font-size:27px;font-weight:400;line-height:1;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"bts-sp-selector-inner\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:300;line-height:1.65;margin:0 0 18px;color:#26332C;\"\u003eStart with your sample. Each card opens an electrode family; on that page, pick BNC, BNC\/RCA pH\/temperature or 8-pin to match your meter.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-labsen-family-comparison\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-211-213-ph-electrode-general-water-tris\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 211 · 213\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-211-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 211 · 213\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3101 \/ AI3121\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eGeneral water, TRIS buffers\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eRefillable everyday glass electrode; BNC or BNC\/RCA pH\/temp.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 211 · 213 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-comparison\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-221-223-ph-electrode-titration-low-ionic-strength\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 221 · 223\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-221-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 221 · 223\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3102 \/ AI3123\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eTitration, low ionic strength\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eMovable sleeve junction: easy to clean, adjustable flow.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 221 · 223 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-comparison\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-231-ph-electrode-wastewater-glass\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 231\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 231\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3111\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eWastewater, suspensions\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eGlass body, open junction and polymer electrolyte.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 231 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-comparison\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-331-333-335-ph-electrode-wastewater-pom\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 331 · 333 · 335\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-331-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 331 · 333 · 335\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3131 \/ AI3133 \/ AI3231\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eWastewater, harsh environments\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eCorrosion-resistant POM body, open junction; BNC, BNC\/RCA or 8-pin.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 331 · 333 · 335 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-link\" data-labsen-family=\"371\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-371-373-ph-electrode-flat-surface\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera LabSen 371 · 373\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-371-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 371 · 373\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3107 \/ AI3172\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eSkin, textiles, paper, leather\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eFlat glass membrane and PTFE ring junction.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 371 · 373 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca aria-current=\"page\" class=\"bts-labsen-family-link\" data-labsen-family=\"801\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-801-803-805-ph-electrode-pure-water\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera LabSen 801 · 803 · 805\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 801 · 803 · 805\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3108 \/ AI3137 \/ AI3233\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003ePure, DI and RO water\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eL-type low-resistance glass (\u0026lt;50 MΩ) for low-ionic water.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-labsen-family-comparison\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-881-ph-electrode-low-temperature\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 881\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 881\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3149\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eCold samples to −25°C\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eL-type conical glass and Protelyte for −25 to 80°C.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 881 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003ePick the version\u003cbr\u003ethat fits your meter.\u003c\/h2\u003e\n\u003cdiv aria-label=\"Version table\" role=\"region\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;overflow-x:auto;width:100%;max-width:100%;\" tabindex=\"0\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;border-collapse:collapse;font-size:1rem;border:1px solid #e0e0e0;table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eVersion\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eConnector and build\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eLabSen 801 · AI3108\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eBNC connector, no temperature sensor; refillable; movable sleeve junction, 3M KCl electrolyte.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eLabSen 803 · AI3137\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eBNC + RCA plugs, built-in 30 kΩ NTC temperature sensor; refillable; movable sleeve junction, 3M KCl electrolyte.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eLabSen 805 · AI3233\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e8-pin connector, built-in 30 kΩ NTC temperature sensor; non-refillable; ceramic × 3 junction, KCl electrolyte.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003e\u003cstrong\u003eBNC\u003c\/strong\u003e versions plug into any pH meter with a BNC input. They have no temperature sensor, so pair them with a separate temperature probe such as Apera’s MP500 for automatic temperature compensation, or enter the temperature manually.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003e\u003cstrong\u003eBNC\/RCA\u003c\/strong\u003e versions carry a built-in 30 kΩ NTC temperature sensor on an RCA plug for automatic temperature compensation on Apera meters with BNC and RCA inputs, such as the \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-benchtop-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH700\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-value-portable-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH850\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph8500-portable-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH8500\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph820-benchtop-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH820\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph910-benchtop-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH910\u003c\/a\u003e and \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph9500-benchtop-ph-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH9500\u003c\/a\u003e. Apera notes they may not work with other brands’ meters because the thermistor might not be compatible.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe \u003cstrong\u003e8-pin\u003c\/strong\u003e version is a pH\/temperature electrode for Apera meters with an 8-pin socket, including the \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-premium-series-ph60-pocket-ph-tester-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH60\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-zentest-ph60-z-smart-ph-tester-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH60-Z\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/tn420-epa-180-1-compliant-portable-turbidity-meter-precision-testing-for-water-quality-professionals-copy\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH400\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-ph400s-portable-ph-meter-kit-with-glp-data-management-and-usb-output\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH400S\u003c\/a\u003e and the PC400, PC400S, SX736 and SX751.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 805 pH electrode\" decoding=\"async\" height=\"1577\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-805-main-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-805-main-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-805-main-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-805-main-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1577\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 805.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eWhat makes it work.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eL-type glass membrane\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLow-resistance formula below 50 MΩ. Apera expects stable readings in about 30–60 seconds in low ionic strength solutions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eSleeve or triple-ceramic junction\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe 801 and 803 use a movable sleeve whose outflow adjusts with sleeve tightness; the 805 uses three ceramic junctions for faster electrolyte discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eSilver ion trap\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eOn the 801 and 803, a silver ion trap added to the reference system reduces junction clogging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 801 feature graphic\" decoding=\"async\" height=\"853\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-tip-20261018-mfr.webp?width=853\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-tip-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-tip-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-tip-20261018-mfr.webp?width=853 853w\" style=\"display:block;width:100%;max-width:460px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"853\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 801 sensing tip.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the specifications.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAll versions share: pH range 1–11; temperature range 0–80°C; body lead-free glass.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eJunction: 801 movable sleeve; 803 movable sleeve; 805 ceramic × 3.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReference electrolyte: 801 3M KCl; 803 3M KCl; 805 KCl.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eDimensions: 801 Ø12 × 130 mm; 803 Ø12 × 130 mm; 805 Ø12 × 120 mm.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe full specification table is in the Product Specifications tab.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eStore it wet.\u003cbr\u003eKeep it clean.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eKeep the tip in its cap with \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-3m-kcl-ph-electrode-storage-soaking-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003e3M KCl storage solution\u003c\/a\u003e whenever it is not measuring.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eNever store a pH electrode in pure, deionized or distilled water.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe 801 and 803 are refillable: keep the fill hole open while measuring and top up the reference electrolyte when the level drops.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe 805 is sealed and needs no refilling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eApera’s manual advises avoiding strong acids, strong alkalis and dehydrating media such as absolute ethanol or concentrated sulfuric acid; if exposure is unavoidable, keep immersion short and clean the electrode carefully afterward.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRinse with distilled or deionized water between samples. For stubborn deposits, use \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-electrode-cleaning-solution-ph-conductivity\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera electrode cleaning solution\u003c\/a\u003e, then recondition and recalibrate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRelated items.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eApera ships this electrode in these kits: \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph700-pw-benchtop-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH700-PW\u003c\/a\u003e (LabSen 803), \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph8500-pw-portable-pure-water-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH8500-PW\u003c\/a\u003e (LabSen 803), \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph850-pw-value-portable-pure-water-ph-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH850-PW\u003c\/a\u003e (LabSen 803), \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-ph60-pw-ph-tester-kit-for-pure-water-with-labsen-805-atc-ph-electrode\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH60-PW\u003c\/a\u003e (LabSen 805), \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-ph60z-pw-smart-ph-tester-kit-for-pure-water-with-labsen-805-electrode\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePH60Z-PW\u003c\/a\u003e (LabSen 805).\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCalibrate with fresh \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-7-00-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 7.00\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-4-00-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 4.00\u003c\/a\u003e and \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-10-01-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 10.01\u003c\/a\u003e buffers.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-labsen-801-faq\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eLabSen 801 · 803 · 805 buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat is the LabSen 801 \/ 803 \/ 805 made for?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eLabSen 801, 803 and 805 measure pH in pure water such as distilled, deionized and RO water and other low ionic strength solutions, where ordinary electrodes drift.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhich version do I need?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eMatch the connector to your meter: BNC for any BNC pH meter (no temperature sensor), BNC\/RCA for Apera meters with BNC and RCA inputs (built-in temperature sensor), or 8-pin for the PH60 and PH60Z testers and other Apera 8-pin meters.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWill the BNC\/RCA version work on another brand’s meter?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe pH signal is standard BNC, but Apera notes the temperature thermistor may not be compatible with other brands’ meters. Use it on Apera meters with BNC and RCA inputs.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs it refillable?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 801 and 803 are refillable; the 805 is sealed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow should I store it?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eKeep the tip in its cap with 3M KCl storage solution whenever it is not measuring. Never use pure, deionized or distilled water.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat warranty applies?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eApera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCheck the version, connector and catalog number (AI3108 \/ AI3137 \/ AI3233) against your meter and samples, then return to the live price and ordering controls.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"LabSen 801 – BNC","offer_id":53008475554090,"sku":"BTS-AI3108","price":216.0,"currency_code":"USD","in_stock":true},{"title":"LabSen 803 – BNC\/RCA with temp sensor","offer_id":53008475586858,"sku":"BTS-AI3137","price":249.0,"currency_code":"USD","in_stock":true},{"title":"LabSen 805 – 8-pin for PH60\/PH60Z","offer_id":53008475619626,"sku":"BTS-AI3233","price":170.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-main-20261018-mfr.webp?v=1792339874","url":"https:\/\/bluetigerscientific.com\/products\/apera-labsen-801-803-805-ph-electrode-pure-water","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}