{"product_id":"apera-labsen-231-ph-electrode-wastewater-glass","title":"Apera LabSen 231 Non-Refillable Glass pH Electrode for Wastewater, Suspensions and Emulsions, BNC","description":"\u003cdiv id=\"bts-labsen-231-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ LABSEN 231 \/ AI3111\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eGlass-body pH for dirty samples.\u003cbr\u003eNo refilling.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLabSen 231 is a non-refillable glass-body pH electrode for wastewater, suspensions, emulsions and other complex solutions that tend to clog the junction of a regular electrode. It combines an open junction with polymer electrolyte and connects to any pH meter with a BNC input.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eIt reads pH 0 to 14; use 0 to 80°C as the provisional common operating envelope pending manufacturer clarification. Catalog AI3111. Apera warrants LabSen electrodes for six months from delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 231 pH electrode\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eApera LabSen 231.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-labsen-general-selector\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;padding:0;margin:24px 0;background:#fff;overflow:visible;\"\u003e\u003csummary aria-label=\"Compare LabSen pH electrodes for general water, wastewater, flat surfaces, pure water and cold samples. Expand or collapse the guide.\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:center;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;cursor:pointer;border-radius:10px;font-weight:600;line-height:1.5;\"\u003e\u003cspan style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:block;flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;line-height:1.35;\"\u003eChoose your LabSen electrode: water and lab\u003c\/span\u003e\u003cspan style=\"display:block;font-size:.88rem;font-weight:400;line-height:1.55;margin-top:5px;\"\u003e\u003cspan class=\"bts-sp-when-closed\"\u003eClick or tap to compare 7 electrode families\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\"\u003eCompare the models below - click or tap here to close\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"bts-sp-toggle\" style=\"display:flex;align-items:center;justify-content:center;flex:0 0 38px;width:38px;height:38px;border:1px solid rgba(23,43,77,.35);border-radius:50%;background:#fff;color:#172b4d;font-size:27px;font-weight:400;line-height:1;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cp class=\"bts-guide-availability\" style=\"font-family:'Open Sans',sans-serif;font-size:15px;line-height:1.6;color:#26332C;margin:12px 0;\"\u003eOnly published products are linked. Other cards provide model-comparison information and do not indicate current storefront availability.\u003c\/p\u003e\n\u003cdiv class=\"bts-sp-selector-inner\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:300;line-height:1.65;margin:0 0 18px;color:#26332C;\"\u003eStart with your sample. Each card opens an electrode family; on that page, pick BNC, BNC\/RCA pH\/temperature or 8-pin to match your meter.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-211-213-ph-electrode-general-water-tris\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 211 · 213\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-211-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 211 · 213\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3101 \/ AI3121\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eGeneral water, TRIS buffers\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eRefillable everyday glass electrode; BNC or BNC\/RCA pH\/temp.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 211 · 213 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-221-223-ph-electrode-titration-low-ionic-strength\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 221 · 223\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-221-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 221 · 223\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3102 \/ AI3123\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eTitration, low ionic strength\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eMovable sleeve junction: easy to clean, adjustable flow.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 221 · 223 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cdiv aria-current=\"page\" class=\"bts-labsen-family-link\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:default;\"\u003e\n\u003cimg alt=\"Apera LabSen 231\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 231\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3111\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eWastewater, suspensions\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eGlass body, open junction and polymer electrolyte.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;background:#F1F7F3;color:#5D6C63;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-331-333-335-ph-electrode-wastewater-pom\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 331 · 333 · 335\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-331-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 331 · 333 · 335\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3131 \/ AI3133 \/ AI3231\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eWastewater, harsh environments\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eCorrosion-resistant POM body, open junction; BNC, BNC\/RCA or 8-pin.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 331 · 333 · 335 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-labsen-family-link\" data-labsen-family=\"371\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-371-373-ph-electrode-flat-surface\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera LabSen 371 · 373\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-371-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 371 · 373\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3107 \/ AI3172\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eSkin, textiles, paper, leather\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eFlat glass membrane and PTFE ring junction.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 371 · 373 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-labsen-family-link\" data-labsen-family=\"801\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-801-803-805-ph-electrode-pure-water\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera LabSen 801 · 803 · 805\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-801-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 801 · 803 · 805\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3108 \/ AI3137 \/ AI3233\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003ePure, DI and RO water\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eL-type low-resistance glass (\u0026lt;50 MΩ) for low-ionic water.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 801 · 803 · 805 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-labsen-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-labsen-881-ph-electrode-low-temperature\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera LabSen 881\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-881-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eLabSen 881\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI3149\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eCold samples to −25°C\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eL-type conical glass and Protelyte for −25 to 80°C.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView LabSen 881 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the connector.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eIt plugs into any pH meter with a BNC input. It has no temperature sensor, so pair it with a separate temperature probe such as Apera’s MP500 where compatible with the meter, for automatic temperature compensation; manual temperature entry is an option only if the meter supports it at the sample temperature. Electrode ratings do not extend the meter’s or separate temperature probe’s operating or compensation limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 231 pH electrode\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-tip-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-tip-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-tip-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-tip-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 231.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eWhat makes it work.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eOpen junction + polymer electrolyte\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eNo ceramic pores for solids and oils to block, and no electrolyte to refill.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eS-type hemispherical membrane\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eLow resistance and high firmness; Apera states stable readings in 15–30 seconds.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eLong-Life reference system\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eGlass-tube Ag\/AgCl reference for stability and service life, with blue gel inner electrolyte.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the specifications.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eKey figures: pH range 0–14; temperature range 0–80°C (provisional common operating envelope); body lead-free glass; glass membrane S-type, half-ball; junction open; reference electrolyte polymer.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe full specification table is in the Product Specifications tab.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eTemperature-source notice: Apera’s current US LabSen 231 page lists 0–100°C, but its linked v2.0 manual specifies −5–80°C. This offer is conservatively limited to their common 0–80°C interval. Do not use the page’s 100°C limit or the manual’s −5°C minimum without written confirmation for the supplied revision.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera LabSen 231 dimension drawing\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-dims-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-dims-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-dims-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-dims-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:460px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eLabSen 231 dimensions, from Apera.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eStore it wet.\u003cbr\u003eKeep it clean.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eKeep the tip in its cap with \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-3m-kcl-ph-electrode-storage-soaking-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003e3M KCl storage solution\u003c\/a\u003e whenever it is not measuring.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eNever store a pH electrode in pure, deionized or distilled water.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eIt is sealed and needs no refilling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eApera’s manual advises avoiding strong acid and strong alkali solutions and dehydrating media such as absolute ethanol or concentrated sulfuric acid; if exposure is unavoidable, keep immersion short and clean the electrode carefully afterward.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRinse with distilled or deionized water between samples. For stubborn deposits, use \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-electrode-cleaning-solution-ph-conductivity\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera electrode cleaning solution\u003c\/a\u003e, then recondition and recalibrate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRelated items.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCalibrate with fresh \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-7-00-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 7.00\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-4-00-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 4.00\u003c\/a\u003e and \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph-10-01-calibration-buffer-solution\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003epH 10.01\u003c\/a\u003e buffers.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-labsen-231-faq\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eLabSen 231 buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat is the LabSen 231 made for?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eLabSen 231 is a non-refillable glass-body pH electrode for wastewater, suspensions, emulsions and other complex solutions that tend to clog the junction of a regular electrode.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs it refillable?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo; it is sealed and needs no refilling.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow should I store it?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eKeep the tip in its cap with 3M KCl storage solution whenever it is not measuring. Never use pure, deionized or distilled water.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan LabSen 231 be used at 100°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNot on the basis of the conflicting documents alone. The current US page says 0–100°C, while the exact v2.0 manual says −5–80°C. Use only the common 0–80°C envelope until Apera confirms the supplied revision.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eDoes LabSen 231 provide temperature compensation?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eLabSen 231 (AI3111; BTS-AI3111) is BNC and has no temperature sensor. ATC needs a compatible separate sensor and meter; manual entry is usable only within the host’s supported compensation range.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhy use an open junction for wastewater?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe LabSen 231 combines an open junction with polymer electrolyte to reduce the clogging associated with dirty samples. The polymer reference is sealed and non-refillable; it still needs cleaning and wet storage.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan I leave LabSen 231 in strong acids, alkalis or solvents?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe exact manual advises avoiding strong acids, strong alkalis and dehydrating media such as absolute ethanol or concentrated sulfuric acid. If exposure is unavoidable, keep it brief and clean carefully afterward; this is not a chemical-resistance guarantee.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat warranty applies?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eApera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCheck the connector and catalog number (AI3111) against your meter and samples, then return to the live price and ordering controls.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":53008209346858,"sku":"BTS-AI3111","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-labsen-231-main-20261018-mfr.webp?v=1792339831","url":"https:\/\/bluetigerscientific.com\/products\/apera-labsen-231-ph-electrode-wastewater-glass","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}