{"product_id":"apera-instruments-ws100-fluoride-ph-portable-meter-kit-with-3-in-1-fluoride-probe","title":"Apera Instruments WS100 Fluoride\/pH Portable Meter Kit with 3-in-1 Fluoride Probe","description":"\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\" id=\"bts-ws100-description\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ WS100 \/ AI4725\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eFluoride and pH in the field.\u003cbr\u003eTwo probes, one case.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe WS100 measures fluoride from 0.02 to 1900 ppm with Apera’s F501-S 3-in-1 electrode, which combines the ion-selective, reference and temperature elements in one body. Apera states it needs no stirring or added reagents. Switch probes and the same meter reads pH from −2.00 to 19.99 with the 201T-S ATC electrode, or ORP with an optional probe.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eBoth electrodes, two fluoride standards and three pH buffers come in the carrying case. The handheld is IP57 rated and runs on two AA batteries; Apera positions it for drinking water, surface water and water treatment testing in the field or the lab.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-hero-20261017-mfr.webp?v=1792272513\u0026amp;width=988\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-hero-20261017-mfr.webp?v=1792272513\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-hero-20261017-mfr.webp?v=1792272513\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-hero-20261017-mfr.webp?v=1792272513\u0026amp;width=988 988w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Apera WS100 portable fluoride meter\" width=\"988\" height=\"988\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:440px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eWS100 meter. The displayed reading is illustrative, not a sample result.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-water-ion-selector\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;padding:0;margin:24px 0;background:#fff;overflow:visible;\"\u003e\u003csummary aria-label=\"Compare three Apera water ion meter kits. Expand or collapse the model guide.\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:center;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;cursor:pointer;border-radius:10px;font-weight:600;line-height:1.5;\"\u003e\u003cspan style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:block;flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;line-height:1.35;\"\u003eChoose your water ion meter\u003c\/span\u003e\u003cspan style=\"display:block;font-size:.88rem;font-weight:400;line-height:1.55;margin-top:5px;\"\u003e\u003cspan class=\"bts-sp-when-closed\"\u003eClick or tap to compare 3 meter kits\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\"\u003eChoose an item below - click or tap here to close\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"bts-sp-toggle\" style=\"display:flex;align-items:center;justify-content:center;flex:0 0 38px;width:38px;height:38px;border:1px solid rgba(23,43,77,.35);border-radius:50%;background:#fff;color:#172b4d;font-size:27px;font-weight:400;line-height:1;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"bts-sp-selector-inner\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:300;line-height:1.65;margin:0 0 18px;color:#26332C;\"\u003eStart with the ion you need to measure, then the extra parameters. All three share the same IP57 handheld meter body and run on two AA batteries. Each card opens that product page.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca aria-current=\"page\" class=\"bts-water-ion-model-link\" data-water-ion-model=\"WS100\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-ws100-fluoride-ph-portable-meter-kit-with-3-in-1-fluoride-probe\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera WS100\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-hero-20261017-mfr.webp?v=1792272513\u0026amp;width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eWS100\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI4725\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eFluoride + pH\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eF501 3-in-1 fluoride probe and 201T-S pH electrode. ORP with an optional probe.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-water-ion-model-link\" data-water-ion-model=\"WS200\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-ws200-fluoride-ph-conductivity-7-in-1-portable-meter-kit\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera WS200\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws200-hero-20261017-mfr.webp?v=1792272513\u0026amp;width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eWS200\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI4721\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eFluoride + pH + conductivity\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eAdds the 2301T-S cell for conductivity, TDS, salinity and resistivity.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView WS200 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-water-ion-model-link\" data-water-ion-model=\"YD300\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-yd300-portable-water-hardness-ca2-and-mg2-meter-kit\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;\"\u003e\u003cimg alt=\"Apera YD300\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-yd300-hero-20261017-mfr.webp?v=1792272513\u0026amp;width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eYD300\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eAI4731\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eWater hardness (Ca²⁺ + Mg²⁺)\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003e601-S hardness electrode with B1\/B2\/B3 standards; eight hardness units.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView YD300 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eKnow what arrives\u003cbr\u003ein the carrying case.\u003c\/h2\u003e\n\u003cdiv aria-label=\"Included item table\" role=\"region\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;overflow-x:auto;width:100%;max-width:100%;\" tabindex=\"0\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;border-collapse:collapse;font-size:1rem;border:1px solid #e0e0e0;table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eIncluded item\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOrder contents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eWS100 meter\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eHandheld IP57 meter in a silicone protective sleeve, two AA batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eF501-S fluoride electrode\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e3-in-1: fluoride ion-selective, reference and temperature elements in one body.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e201T-S pH electrode\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eCombination pH electrode with ATC, in a storage bottle.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eFluoride calibration solutions\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e0.19 mg\/L and 19.00 mg\/L, 50 mL each.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003epH buffer solutions\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003epH 4.00, 7.00 and 10.01, 50 mL each.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eSpare AA batteries\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eThree.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eScrewdriver\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eFor the battery cover.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eCarrying case\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eApera lists the kit case at 360 × 270 × 76 mm and 1.5 kg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eInstruction manual\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eWS100 operation, calibration and maintenance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eKit list follows Apera’s WS100 instruction manual and Apera’s US product page.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-kit-20261017-mfr.webp?v=1792272513\u0026amp;width=969\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-kit-20261017-mfr.webp?v=1792272513\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-kit-20261017-mfr.webp?v=1792272513\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-kit-20261017-mfr.webp?v=1792272513\u0026amp;width=969 969w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Apera WS100 kit in its carrying case with meter, electrodes and calibration solutions\" width=\"969\" height=\"969\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:560px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eWS100 kit as shipped: meter, electrodes, standards and accessories in the foam-lined case.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-activation-20261017-mfr.webp?v=1792272513\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-activation-20261017-mfr.webp?v=1792272513\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-activation-20261017-mfr.webp?v=1792272513\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-activation-20261017-mfr.webp?v=1792272513\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"WS100 manual fluoride preparation and electrode activation steps\" width=\"1470\" height=\"723\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:560px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eWS100 instruction manual, section 4.1: connect the F501-S, choose the unit and activate the electrode.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eActivate the fluoride probe.\u003cbr\u003eThen calibrate at two points.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eConnect the F501-S and the meter switches to fluoride mode on its own. A new electrode, or one being used for the first time, soaks in the 19.00 mg\/L standard for one hour; in regular use, 10 to 20 minutes is enough. Wait until the reading settles and the smiley-face stability icon stays on before you calibrate. Readings during activation are random.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003ePress CAL and the meter asks for 0.19 mg\/L first, then 19.00 mg\/L. Rinse the probe in distilled or deionized water, shake off the excess, dip it, stir gently and let it stand; press CAL again when the stability icon stays on. The L and H icons confirm a two-point calibration. Apera states no stirring or added reagents are needed in the sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eProtect the fluoride result.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eMatch the prompt\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe meter does not recognize which fluoride standard is in the cup. Use the solution the display asks for, 0.19 mg\/L or 19.00 mg\/L; the wrong one produces a wrong calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eKeep the low standard clean\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe 0.19 mg\/L standard contaminates easily, and a small amount of carryover causes a large error. Apera recommends replacing the fluoride standards after four to five uses.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eLow to high, same temperature\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eMeasure from low to high concentration where you can; going from high to low, rinse first. Keep samples within ±15°C of the standards, and at the same temperature for the best accuracy. Apera lists a sample pH requirement of 5.0–6.0 for fluoride.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCalibrate pH at one, two or three points.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eConnect the 201T-S pH\/ATC electrode, unscrew its storage bottle and the meter opens in pH mode. Calibration starts at pH 7.00 (C1), then pH 4.00 (C2) and pH 10.01 (C3); press the enter key after any point to stop there. One point at pH 7.00 suits work to ±0.1 pH; use 4.00\/7.00 for acidic samples, 7.00\/10.01 for alkaline samples, and all three for a wide range or a new electrode.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe meter recognizes buffers from three series: USA (1.68, 4.00, 7.00, 10.01, 12.45), NIST (1.68, 4.01, 6.86, 9.18, 12.45) and CH. Err1 flags an electrode zero point outside ±60 mV and Err2 a slope outside 85–105%. Store the electrode in its bottle of 3M KCl (Apera AI1107); Apera puts its service life at about one to two years.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003ePurified water compensation\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eTwo optional settings apply pH temperature compensation for purified water and for purified water with ammonia added. Both are off by default.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eORP with an optional probe\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eShort-press the mode key for mV. With Apera’s 301Pt-S ORP electrode, sold separately, the meter reads −1999 to 1999 mV at 1 mV resolution, ±0.1% FS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-lcd-20261017-mfr.webp?v=1792272513\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-lcd-20261017-mfr.webp?v=1792272513\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-lcd-20261017-mfr.webp?v=1792272513\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-lcd-20261017-mfr.webp?v=1792272513\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"WS100 manual LCD display diagram with numbered indicators\" width=\"1470\" height=\"987\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:560px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eWS100 instruction manual, section 3.1: display layout and indicators.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRead the display at a glance.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe backlit LCD shows the parameter, the reading, the unit and the sample temperature together, with a smiley-face icon once the reading is stable and L, M and H icons for the calibration points in use. A battery icon warns when the two AA cells are low.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFive keys run the meter: power, CAL, MODE, enter\/backlight and M+\/RM. Press M+ when the reading is stable to store it with its number, unit and temperature; hold it to recall stored readings. The backlight times out after 0, 1, 3 or 6 minutes and the meter switches itself off after 0, 10 or 20 minutes, both set in the parameter menu.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the specifications.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFluoride accuracy is ±0.02 ppm or ±5% of reading, whichever is greater, with automatic temperature compensation from 0 to 80°C. pH accuracy is ±0.01 pH ±1 digit, with compensation from 0 to 100°C.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe meter stores 300 readings with their number, unit and temperature. It measures 65 × 120 × 31 mm and weighs 180 g, runs on two AA batteries and is IP57 rated against dust and water.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-specs-20261017-mfr.webp?v=1792272513\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-specs-20261017-mfr.webp?v=1792272513\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-specs-20261017-mfr.webp?v=1792272513\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-manual-specs-20261017-mfr.webp?v=1792272513\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"WS100 manual technical parameters table\" width=\"1470\" height=\"1304\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:520px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eWS100 instruction manual, section 2: technical parameters.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCompare the other water ion kits.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-ws200-fluoride-ph-conductivity-7-in-1-portable-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera WS200 (AI4721)\u003c\/a\u003e uses the same meter and fluoride and pH probes, and adds a 2301T-S cell for conductivity, TDS, salinity and resistivity. For calcium and magnesium hardness, the \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-instruments-yd300-portable-water-hardness-ca2-and-mg2-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eYD300 (AI4731)\u003c\/a\u003e uses the same handheld format with Apera’s 601-S hardness electrode.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\" id=\"bts-ws100-faq\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eWS100 buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat does the F501-S fluoride probe include?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eIt is a 3-in-1 combination electrode: fluoride ion-selective, reference and temperature elements in one body. Apera states that no stirring or added reagents are needed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow long does activation take?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eOne hour in the 19.00 mg\/L standard for a new electrode or first use; 10 to 20 minutes in regular use. Start calibrating once the reading is stable.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhich fluoride units can it display?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003emg\/L, ppm and pF. The meter also shows the electrode mV.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow often should I calibrate fluoride?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eApera recommends calibrating before each use when accuracy matters. If accuracy needs are low, check the probe in a standard first; if the error is small, recalibration is not necessary.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan it measure ORP?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes, in mV mode with Apera’s 301Pt-S ORP electrode, which is sold separately: −1999 to 1999 mV at 1 mV resolution.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow should I store the electrodes?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eRinse the fluoride probe, shake off the water and store it dry with its cap on. Keep the pH electrode in its storage bottle of 3M KCl.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat does it run on?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eTwo AA batteries, with three spares in the kit. The meter is IP57 rated and turns itself off after 10 minutes by default.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat warranty applies?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eApera’s limited warranty covers the meter for two years and the probes for six months from delivery, excluding misuse, accidental damage, improper maintenance, unauthorized repair and the other causes in Apera’s terms. Warranty service is handled through Apera; returns are coordinated with Blue Tiger Scientific.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReview WS100 AI4725 against the parameters you need to report, your sample pH and range, and the standards you will keep on hand. Return to the live price and ordering controls when the configuration fits your work.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":52993339326762,"sku":"BTS-AI4725","price":690.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ws100-hero-20261017-mfr_c48ffb6e-8249-4266-b886-5e719e738529.webp?v=1792272878","url":"https:\/\/bluetigerscientific.com\/products\/apera-instruments-ws100-fluoride-ph-portable-meter-kit-with-3-in-1-fluoride-probe","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}