{"product_id":"apera-ec910-benchtop-conductivity-meter-kit","title":"Apera EC910 Benchtop Conductivity Meter Kit with 2301T-F Electrode","description":"\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\" id=\"bts-ec910-description\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ EC910 \/ AI5612\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConductivity, with a clearer workflow.\u003cbr\u003eFrom guided calibration to stored results.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eEC910 combines a color-screen bench meter with the 2301T-F conductivity\/temperature electrode and a 602 flexible holder. Measure conductivity, select TDS or salinity displays, and retain up to 200 sets of results. Its graphical prompts support repeatable calibration without turning a dedicated conductivity station into a pH instrument.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eChoose EC910 when your bench method needs user-defined conductivity standards, visible setup prompts and USB data transfer. The current US kit is AI5612 with a plastic-body K=1 probe. The meter range ends at 200 mS\/cm; fitting a higher-range electrode does not change that electronics limit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-hero-20261016-core6.webp?v=1792167666\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-hero-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-hero-20261016-core6.webp?v=1792167666\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-hero-20261016-core6.webp?v=1792167666\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"EC910 conductivity meter with 2301T-F probe and 602 holder\" width=\"1400\" height=\"933\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:340px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eExact EC910 configuration with its 602 flexible holder and conductivity probe. Glassware is illustrative; no integrated stirrer is supplied.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-core6-kit-guide\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;margin:24px 0;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;border-radius:10px;cursor:pointer;line-height:1.5;\"\u003e\u003cspan style=\"flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;\"\u003eWhich meter kit fits my measurement?\u003c\/span\u003e\u003cspan class=\"bts-sp-when-closed\" style=\"display:block;font-size:.88rem;margin-top:5px;\"\u003eClick or tap to compare all six measurement configurations\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\" style=\"font-size:.88rem;\"\u003eClick or tap here to close the guide\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"bts-sp-toggle\" aria-hidden=\"true\" style=\"flex:0 0 38px;width:38px;height:38px;display:flex;align-items:center;justify-content:center;border-radius:50%;background:white;font-size:27px;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eEach card opens that model page. Match the supplied electrode and documented sample method. pH, conductivity and optical dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-core6-kit-link\" data-core6-kit=\"PH910\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ph910-benchtop-ph-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ph910-hero-20261016-core6.webp?v=1792167666\u0026amp;width=200\" alt=\"Apera PH910\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePH910\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5610\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eBenchtop pH with records\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eLabSen 211 pH-only electrode and separate MP500 temperature probe.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PH910 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-core6-kit-link\" data-core6-kit=\"EC910\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec910-benchtop-conductivity-meter-kit\" aria-current=\"page\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-hero-20261016-core6.webp?v=1792167666\u0026amp;width=200\" alt=\"Apera EC910\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003eEC910\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5612\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eBenchtop conductivity with records\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e2301T-F cell and model-specific USB record workflow.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-core6-kit-link\" data-core6-kit=\"PC910\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc910-benchtop-ph-conductivity-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-pc910-hero-20261016-core6.webp?v=1792167666\u0026amp;width=200\" alt=\"Apera PC910\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003ePC910\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI5614\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eBenchtop pH and conductivity\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003eSeparate pH and EC probes, each with its own temperature input.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView PC910 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-core6-kit-link\" data-core6-kit=\"EC700\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec700-benchtop-conductivity-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec700-hero-20261016-core6.webp?v=1792167666\u0026amp;width=200\" alt=\"Apera EC700\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003eEC700\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI502\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eStraightforward conductivity bench\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e2301T-F cell and local 50-set recall, without documented USB export.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView EC700 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-core6-kit-link\" data-core6-kit=\"DO850\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-do850-10-ft-optical-dissolved-oxygen-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-do850-hero-20261016-core6.webp?v=1792167666\u0026amp;width=200\" alt=\"Apera DO850\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003eDO850\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI480\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eDirect optical dissolved oxygen\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e10-ft DO803 optical probe; stable display and external recordkeeping.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView DO850 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\u003ca class=\"bts-core6-kit-link\" data-core6-kit=\"DO8500\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-do8500-10-ft-optical-dissolved-oxygen-meter-kit\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;align-items:flex-start;gap:14px;flex:1 1 300px;min-width:0;padding:18px;border:1px solid #e0e0e0;background:white;border-radius:9px;text-decoration:none;color:#26332C;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-do8500-hero-20261016-core6.webp?v=1792167666\u0026amp;width=200\" alt=\"Apera DO8500\" width=\"72\" height=\"72\" loading=\"lazy\" style=\"width:72px;height:72px;flex:0 0 72px;object-fit:contain;background:white;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:700;line-height:1.3;margin:0 0 4px;color:#245B45;\"\u003eDO8500\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;margin:0 0 9px;\"\u003eAI485\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;margin:0 0 6px;\"\u003eOptical DO with recording\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;margin:0 0 12px;\"\u003e10-ft optical probe plus salinity electrode and documented logging.\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:inline-block;padding:6px 9px;border-radius:5px;background:#FFF0DD;font-size:.85rem;font-weight:700;\"\u003eView DO8500 →\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eChoose the electrode for the sample.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eA conductivity cell with temperature built in\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe supplied 2301T-F uses a platinum-black sensing surface, a POM plastic body and a 30 kΩ thermistor. Conductivity connects through BNC and temperature through RCA. The probe manual rates conductivity to 200 mS\/cm at 0 to 50°C. This is a replaceable two-signal electrode, not a separate glass pH probe and temperature wand.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003ePrompts that explain the next step\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe color interface illustrates rinsing, immersion and waiting for a stable reading. Plain-language menus expose cell constant, reference temperature, compensation and TDS factor. HOLD and the stable-reading symbol help the operator follow a method, but neither proves a sample is uncontaminated or saves a record automatically. The 602 holder positions the probe without adding an integrated magnetic stirrer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eCompensation under your control\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReference temperature is adjustable from 15 to 30°C, with 25°C as the default. The current US page lists a 0.00 to 10.00%\/°C compensation coefficient and a default of 2.0%\/°C. TDS conversion is adjustable from 0.40 to 1.00, default 0.71. Select settings for the actual sample composition and retain them with your procedure; derived TDS is not a gravimetric solids measurement. The current US compensation-coefficient specification is 0.00 to 10.00%\/°C, default 2.0%\/°C; custom calibration has its separate same-temperature restriction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eKnow what this configuration supplies.\u003c\/h2\u003e\n\u003cdiv aria-label=\"Included item table\" role=\"region\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;overflow-x:auto;width:100%;max-width:100%;\" tabindex=\"0\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;border-collapse:collapse;font-size:1rem;border:1px solid #e0e0e0;table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eIncluded item\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eOrder contents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eEC910 conductivity meter\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eAI5612 dedicated conductivity\/TDS\/salinity bench meter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e2301T-F conductivity\/temperature electrode\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003ePOM body; K=1.0; BNC\/RCA connections and storage cap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e602 flexible electrode holder\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eAdjustable probe support; no integrated magnetic stirrer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eThree conductivity standards\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e84 µS\/cm, 1413 µS\/cm and 12.88 mS\/cm; 50 mL each.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eUSB cable and software flash drive\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eCurrent US kit names the media PC-Link 9500 Flash Drive; confirm EC910 software compatibility separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e9 V adapter and user manual\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eBench power supply and operating instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-holder-20261016-core6.webp?v=1792167666\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-holder-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-holder-20261016-core6.webp?v=1792167666\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-holder-20261016-core6.webp?v=1792167666\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"EC910 with articulated 602 holder and joint detail\" width=\"1400\" height=\"1400\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eThe 602 holder adjusts probe position and accepts up to three electrodes. Only the listed conductivity electrode is included; this is not a 606 stirring test bench.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eMatch the sample and preparation method.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eRoutine aqueous process comparisons\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse the conductivity response to compare compatible water samples, rinses and solution preparations under a consistent method. Keep sample temperature and containers controlled. Conductivity measures the combined electrical response of ions; it does not identify a specific chemical, establish drinking-water safety or replace a chemical assay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eTeaching and method development\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe current US page advertises general, saltwater and NaCl salinity modes, while the linked regional USB manual documents a generic salinity mode. Confirm the delivered revision’s available salinity options if a particular basis is essential. Conductivity-derived salinity does not identify all dissolved species or replace a composition-specific method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003ePlanning outside the regular range\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe exact EC910 manual recommends K=0.1 below 20 µS\/cm and K=10 above 100 mS\/cm. The current US page identifies DJS-0.1-F and 2310T-F as compatible alternatives. These are separate purchases. The latter probe may be rated to 2000 mS\/cm, but an EC910 combination remains limited to the meter's 200 mS\/cm maximum.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"calibration\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-calibration-20261016-core6.webp?v=1792167666\u0026amp;width=654\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-calibration-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-calibration-20261016-core6.webp?v=1792167666\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-calibration-20261016-core6.webp?v=1792167666\u0026amp;width=654 654w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Original EC910 conductivity calibration prompt at 1413 µS\/cm\" width=\"654\" height=\"373\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal CAL-Cond prompt: immerse in the selected standard, stir lightly to release bubbles and wait for the stable symbol before confirming. This example is not a measured accuracy result.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCalibrate the cell.\u003cbr\u003eKeep the standard and sample method aligned.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eConnect the 2301T-F BNC plug to the conductivity input and RCA plug to temperature. Remove the storage cap, rinse with distilled or deionized water and confirm the cell constant is K=1. Immerse the sensing end without resting it on the vessel, stir briefly to release bubbles, then wait for the conductivity and temperature signals to settle.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eStandard calibration recognizes 84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm and 111.8 mS\/cm. The kit supplies the first three in 50 mL bottles, not the fourth. Use clean portions, work from low to high conductivity and rinse between standards. The exact probe instructions recommend two or three points after installing a new electrode; select points appropriate to your measurement range.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eEC910 also has a User calibration selection. The exact European EC910 manual illustrates a customized 10 µS\/cm standard, while the current US page confirms user-defined standards. Use an accurately characterized standard and its correct temperature basis. This setting changes calibration, not the instrument range. Check an independent standard when the result matters and investigate drift before accepting a batch. The manual permits one custom point and requires calibration and measurement at the same temperature; reference-temperature and temperature-coefficient adjustment do not apply in this mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"custom-calibration\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-custom-calibration-20261016-core6.webp?v=1792167666\u0026amp;width=595\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-custom-calibration-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-custom-calibration-20261016-core6.webp?v=1792167666\u0026amp;width=595 595w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"EC910 manual screen selecting User conductivity calibration\" width=\"595\" height=\"336\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:595px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eExact EC910 manual example: User is selected under CAL solution selection. Menu art is a documented family interface example, not a hardware-tested firmware screenshot.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eUnderstand the sensing end and connections.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-cell-20261016-core6.webp?v=1792167666\u0026amp;width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-cell-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-cell-20261016-core6.webp?v=1792167666\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-cell-20261016-core6.webp?v=1792167666\u0026amp;width=1000 1000w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Original 2301T platinum-black conductivity cell graphic\" width=\"1400\" height=\"1400\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal manufacturer 2301T cell graphic, supplied on the EC910 page. Its 200 mS\/cm rating is a probe limit, not proof of accuracy throughout every sample matrix. Fast, Accurate and Stable are manufacturer design claims, not independent test results.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-probe-20261016-core6.webp?v=1792167666\u0026amp;width=750\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-probe-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-probe-20261016-core6.webp?v=1792167666\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-probe-20261016-core6.webp?v=1792167666\u0026amp;width=750 750w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"2301T-F POM conductivity and temperature electrode\" width=\"750\" height=\"750\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:480px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eThe supplied 2301T-F K=1 electrode. Rinse the sensing end gently and keep its electrical connectors clean and dry.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eProtect the platinum-black surface.\u003cbr\u003eStore this conductivity probe in clean water.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRinse before and after samples and calibration. Gently blot excess water without rubbing the sensing surface; a final rinse with a little sample can reduce dilution. Keep used standards separate from their stock bottles. Air bubbles in the sensing head can destabilize results, so briefly stir after immersion rather than scraping or tapping the cell.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe exact 2301T-F instructions specify a storage cap filled with distilled or deionized water. Replace contaminated water and clean the cap before refitting it. Do not substitute the KCl solution used for many pH electrodes. Keep electrical connectors clean and dry, and avoid pulling on the cable when disconnecting the probe.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFor organic residue, the probe manual describes warm detergent water and alcohol with a soft brush. Follow the acid-cleaning treatment specified in the probe instructions for calcium or magnesium deposits. Follow those instructions rather than an improvised abrasive cleaning method, rinse thoroughly and recalibrate after cleaning. The broader 0 to 80°C probe operating limit is not an extension of the 0 to 50°C conductivity compensation range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"rinse\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-rinse-20261016-core6.webp?v=1792167666\u0026amp;width=652\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-rinse-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-rinse-20261016-core6.webp?v=1792167666\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-rinse-20261016-core6.webp?v=1792167666\u0026amp;width=652 652w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Original CAL-Cond screen illustrating rinse and gentle drying\" width=\"652\" height=\"373\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:500px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal conductivity guidance screen: rinse with pure water and remove excess moisture gently. Never rub the platinum-black sensor. Screen artwork is illustrative.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-connections-20261016-core6.webp?v=1792167666\u0026amp;width=540\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-connections-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-connections-20261016-core6.webp?v=1792167666\u0026amp;width=540 540w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"EC910 conductivity BNC and temperature RCA sockets\" width=\"540\" height=\"370\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eDetail from the EC910 rear photograph: conductivity BNC and temperature RCA. The cropped view excludes unused printed pH\/ORP\/DO positions and does not document USB placement.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"lcd\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-lcd-20261016-core6.webp?v=1792167666\u0026amp;width=525\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-lcd-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-lcd-20261016-core6.webp?v=1792167666\u0026amp;width=525 525w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"Conductivity LCD diagram with numbered EC910 indicators\" width=\"525\" height=\"280\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal EC910 manual legend: 1 mode; 2 result and unit; 3 temperature; 4 reference\/compensation settings; 5 calibration icons; 6 used memory; 7 ATC\/MTC; 8 HOLD; 9 stable; 10 date\/time; 11 timed logging; 12 computer-link indicator. Illustrative interface, not a test result.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"tds\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-tds-20261016-core6.webp?v=1792167666\u0026amp;width=452\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-tds-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-tds-20261016-core6.webp?v=1792167666\u0026amp;width=452 452w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"EC910 manual TDS display showing conversion factor\" width=\"452\" height=\"244\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eTDS display example from the exact EC910 manual. The 0.71 factor converts conductivity into a calculated result; it is not a separate gravimetric solids analysis.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRead the display. Check the measurement mode.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUse the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eFollow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003e200 stored sets.\u003cbr\u003eConfirm the computer workflow before relying on it.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe current US specification lists 200 stored sets containing numbering, date, time, measurement and temperature. Manual and timed logging are documented. Keep sample identities in your worksheet and export before clearing memory. The exact European manual distinguishes internal storage from live uploads to the computer, so do not assume every computer-transmitted result also remains in meter memory.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eUSB transfer is documented for EC910. Its exact European manual describes PC-Link 910 and spreadsheet export. The current US page advertises Web PC-Link, PC\/Mac use and CSV\/JSON export, but its linked application identifies itself as 9500 Series. That link and the kit's “PC-Link 9500 Flash Drive” label do not independently establish EC910 browser-protocol compatibility. Confirm the supported software, operating system and hardware revision before purchase if export is essential.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eNo software has been installed and no device connection has been tested for this reference. Manufacturer data-management language and interface illustrations are not evidence of a validated LIMS connection, audit trail or regulatory compliance. The record-view graphic shows the documented conductivity layout, not measurements collected during a product test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:620px;margin:0 auto;min-width:0;\" data-mfr-feature=\"data-recall\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-data-recall-20261016-core6.webp?v=1792167666\u0026amp;width=445\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-data-recall-20261016-core6.webp?v=1792167666\u0026amp;width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-data-recall-20261016-core6.webp?v=1792167666\u0026amp;width=445 445w\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" alt=\"EC910 manual conductivity record-recall screen\" width=\"445\" height=\"252\" loading=\"lazy\" decoding=\"async\" style=\"display:block;width:100%;max-width:445px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eOriginal View-Cond example from the exact EC910 manual: record number, date, time, conductivity and temperature\/ATC. Example values illustrate the layout, not independently collected records or software validation.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCompare another benchtop format.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAlternative format: \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec950-benchtop-conductivity-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eApera EC950 Benchtop Conductivity Meter Kit with 2401T-F and TestBench\u003c\/a\u003e. The linked meter has a different bench arrangement, supplied probes or record workflow. Review its own kit and instructions before choosing. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\" id=\"bts-ec910-faq\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eEC910 buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eDoes EC910 measure pH?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. It measures conductivity, TDS, salinity and temperature. The current kit table contains a “pH\/Conductivity Meter” wording error; the EC910 model matrix and conductivity specifications do not assign pH capability to this model.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs the supplied electrode glass or plastic?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eIt is the 2301T-F POM plastic-body K=1 electrode with BNC\/RCA plugs and a built-in 30 kΩ temperature sensor. Alternative glass or different-cell-constant probes are not included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eCan a K=10 probe extend the meter to 2000 mS\/cm?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The optional 2310T-F probe's own rating is not the meter rating. EC910 remains a 200 mS\/cm instrument; the manual recommends K=10 above 100 mS\/cm for suitable high-range work.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eAre all four standards supplied?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The kit includes 84 µS\/cm, 1413 µS\/cm and 12.88 mS\/cm, 50 mL each. The recognized 111.8 mS\/cm standard must be obtained separately if required by your method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow should I interpret the accuracy?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe specification is ±1.0% full scale plus one digit, not ±1% of every reading. Active range, standard quality, temperature correction, electrode condition and sample handling also affect method uncertainty.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eIs the holder a stirring test bench?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. AI5612 includes the 602 flexible electrode holder, not a 606 test bench with integrated stirrer. Beakers shown in manufacturer photos illustrate placement and are not listed kit contents.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eDoes the 0 to 100°C display mean compensation to 100°C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The meter temperature display spans 0 to 100°C, while conductivity compensation is specified from 0 to 50°C. Observe the electrode and sample compatibility limits as well.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat warranty applies to this kit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe current US EC910 warranty states three years for the instrument and six months for the probe from delivery. The exact European EC910 manual states the same durations under its regional terms. Coverage is limited to qualifying defects; misuse, storage damage, wear and other listed exclusions apply.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReview EC910 AI5612 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":52968218755370,"sku":"BTS-AI5612","price":465.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-ec910-hero-20261016-core6.webp?v=1792167666","url":"https:\/\/bluetigerscientific.com\/products\/apera-ec910-benchtop-conductivity-meter-kit","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}