{"product_id":"apera-do503-membrane-caps-3-pack","title":"Apera DO503 Replacement Membrane Caps for DO500, 3-Pack | AI4113","description":"\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\" id=\"bts-do503-description\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,42px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ DO503 \/ AI4113\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eThree replacement membrane caps for the DO500 electrode\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe Apera DO503 pack contains three replacement membrane caps for the Apera DO500 polarographic dissolved oxygen electrode. Use the specified caps and fresh DO502 inner solution when servicing the DO500 membrane assembly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-do503-do503-caps-source.webp?v=1792336593\" alt=\"Three Apera DO503 replacement membrane caps for DO500\" width=\"2500\" height=\"2500\" loading=\"lazy\" style=\"display:block;width:100%;max-width:340px;height:auto;object-fit:contain;margin:0 auto;box-sizing:border-box;\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.85rem;line-height:1.55;color:#5D6C63;text-align:center;margin-top:12px;\"\u003eManufacturer photograph of the three-cap DO503 pack.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-do503-guide\" style=\"border:1px solid #FF931A;border-radius:10px;margin-top:28px;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;box-sizing:border-box;font-size:1rem;font-weight:600;padding:18px;background:#FF931A;cursor:pointer;border-radius:9px;\"\u003eWhich system is this replacement for?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:18px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eCURRENT ITEM: DO503\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThese are selected compatible meter-system or related-workflow pages, not additional items supplied with this accessory. Match the exact probe or component in the compatibility table below.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:block;flex:1 1 220px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;color:#26332C;text-decoration:none;background:white;\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-sx716-portable-polarographic-dissolved-oxygen-meter-kit\" data-meter=\"SX716\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-sx716-hero-20261016-sx700-eight.webp?v=1792171716\" alt=\"Apera SX716 Portable Dissolved Oxygen Meter Kit with DO500 Polarographic Probe\" loading=\"eager\" style=\"display:block;width:100%;max-width:105px;height:105px;object-fit:contain;margin:0 auto 14px;\"\u003e\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.05rem;font-weight:600;line-height:1.2;color:#245B45;margin:0 0 10px;\"\u003eSX716\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRelated workflow: meter supplied with DO500\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-weight:600;text-decoration:underline;color:#245B45;\"\u003eView meter configuration\u003c\/span\u003e\u003c\/a\u003e\u003ca style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:block;flex:1 1 220px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;color:#26332C;text-decoration:none;background:white;\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-sx725-portable-ph-dissolved-oxygen-meter-kit\" data-meter=\"SX725\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-sx725-hero-20261016-sx700-eight.webp?v=1792171716\" alt=\"Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe\" loading=\"eager\" style=\"display:block;width:100%;max-width:105px;height:105px;object-fit:contain;margin:0 auto 14px;\"\u003e\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.05rem;font-weight:600;line-height:1.2;color:#245B45;margin:0 0 10px;\"\u003eSX725\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRelated workflow: meter supplied with DO500\u003c\/p\u003e\n\u003cspan style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-weight:600;text-decoration:underline;color:#245B45;\"\u003eView meter configuration\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eWhy choose this replacement?\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eExact electrode match\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eApera identifies DO503 as the replacement membrane cap for DO500. Select by electrode model, not by the meter connector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eThree-cap pack\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe official product description and SX716 replacement-parts table both specify three caps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eDocumented replacement process\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eSection 4.5.4 of the SX716 manual explains cap replacement with new DO502 inner solution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the exact probe and meter system.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:100%;min-width:0;\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;text-align:left;background:#F1F7F3;font-weight:600;border:1px solid #B7D0BF;overflow-wrap:anywhere;\"\u003eModel or component\u003c\/th\u003e\n\u003cth style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;text-align:left;background:#F1F7F3;font-weight:600;border:1px solid #B7D0BF;overflow-wrap:anywhere;\"\u003eCompatibility and role\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;border:1px solid #B7D0BF;vertical-align:top;overflow-wrap:anywhere;\"\u003eDO500\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;border:1px solid #B7D0BF;vertical-align:top;overflow-wrap:anywhere;\"\u003eCompatible electrode. Explicit manufacturer compatibility. This listing is for the polarographic membrane system, not an optical DO803 or DO810 cap.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eOptical sensor caps and polarographic membrane components are different replacement systems. A shared brand or similar appearance does not establish interchangeability.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eReplace the cap using the documented DO500 procedure\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe SX716 manual instructs you to remove the old membrane cap, rinse the electrode with distilled water and clean the gold cathode as directed. Slowly add fresh DO502 inner solution to a new DO503 cap without introducing air bubbles.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAssemble the cap vertically and tighten as directed. Wipe away displaced solution and rinse the electrode. Inspect for trapped air; reassembly may be necessary. Refer to section 4.5.4 for the complete procedure.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eMatch the sensing system to the work.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eDamaged-membrane replacement\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe SX716 manual calls for replacement when the membrane is wrinkled, cracked or damaged.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eDO500 maintenance\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eInspect the membrane when response becomes slower or obvious measurement errors occur, following the manual before replacing components.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eWhat this order supplies\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:100%;min-width:0;\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;text-align:left;background:#F1F7F3;font-weight:600;border:1px solid #B7D0BF;overflow-wrap:anywhere;\"\u003eIncluded item\u003c\/th\u003e\n\u003cth style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;text-align:left;background:#F1F7F3;font-weight:600;border:1px solid #B7D0BF;overflow-wrap:anywhere;\"\u003eOrder contents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;border:1px solid #B7D0BF;vertical-align:top;overflow-wrap:anywhere;\"\u003eDO503 membrane caps\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;border:1px solid #B7D0BF;vertical-align:top;overflow-wrap:anywhere;\"\u003e3 replacement caps for the DO500 electrode\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eProtect the sensitive membrane surface\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eDo not touch the sensitive membrane directly with your fingers. The manual warns that sweat and grease affect membrane quality.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAfter fitting a new membrane cap or adding new solution, the SX716 procedure requires 30 minutes of polarization. Follow the meter calibration procedure before resuming measurement.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:30px 0;line-height:1.2;\" id=\"bts-do503-faq\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eDO503 buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eHow many caps are supplied?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eEach DO503 pack contains three replacement membrane caps.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eWhich electrode does DO503 fit?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe manufacturer explicitly specifies Apera DO500 polarographic DO electrode compatibility.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eIs DO503 an optical sensor cap?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eNo. This is the DO500 polarographic membrane cap. Do not substitute it for the optical sensor cap specified for DO803 or DO810.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eIs inner solution included in this cap pack?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe DO503 listing specifies three caps only. Order DO502 inner solution separately when it is needed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eWhen should the cap be replaced?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe SX716 manual identifies a wrinkled, cracked or damaged membrane, slower response or obvious measurement errors as reasons to inspect and replace the cap.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eCan I touch the membrane during installation?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAvoid direct finger contact with the sensitive membrane because sweat and grease affect membrane quality.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eIs five minutes of polarization enough after replacement?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eNot for the SX716 procedure after cap replacement. Its manual specifies 30 minutes when a new cap or new inner solution is installed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #B7D0BF;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"font-family:Open Sans,sans-serif;font-weight:600;box-sizing:border-box;font-size:1rem;line-height:1.2;padding:16px;cursor:pointer;\"\u003eWhere are the installation instructions?\u003c\/summary\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:0 16px 4px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eSection 4.5.4 of the linked SX716 meter manual covers membrane-cap replacement. The document is a meter manual, not a standalone DO503 manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":53007233155370,"sku":"BTS-AI4113","price":48.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-do503-do503-caps-source.webp?v=1792336593","url":"https:\/\/bluetigerscientific.com\/products\/apera-do503-membrane-caps-3-pack","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}