{"product_id":"apera-2401-series-glass-conductivity-electrode-k1-2401-c-2401t-f","title":"Apera 2401 Series Glass Conductivity Electrode, K=1: 2401-C or 2401T-F","description":"\u003cdiv id=\"bts-apera-2401-description\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;max-width:1400px;margin:0 auto;color:#26332C;font-size:1rem;line-height:1.75;\"\u003e\n\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(20px,4vw,48px);border:1px solid #B7D0BF;background:#F1F7F3;border-radius:14px;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.76rem;font-weight:600;letter-spacing:.12em;text-transform:uppercase;color:#245B45;margin:0 0 12px;\"\u003eAPERA INSTRUMENTS \/ 2401-C · 2401T-F \/ AI1308 \/ AI1309\u003c\/p\u003e\n\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eGlass and platinum\u003cbr\u003efor high-accuracy lab conductivity.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eApera’s 2401 series glass-body conductivity electrodes (K=1.0) are designed for high-accuracy laboratory conductivity measurement from 0 to 200 mS\/cm. A cavity structure around a platinum chip sensor improves stability and accuracy, and the glass body resists chemical corrosion. The 2401-C has a BNC connector; the 2401T-F adds a built-in temperature sensor with BNC\/RCA plugs.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eChoose the version from the menu above. Apera’s warranty: six months from delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera 2401 Glass Conductivity\" decoding=\"async\" height=\"736\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-main-20261018-mfr.webp?width=736\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-main-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-main-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-main-20261018-mfr.webp?width=736 736w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"736\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eApera 2401-C · 2401T-F.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdetails id=\"bts-apera-standard-electrode-selector\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;border:1px solid #FF931A;border-radius:10px;padding:0;margin:24px 0;background:#fff;overflow:visible;\"\u003e\u003csummary aria-label=\"Compare Apera PC-body pH, ORP, conductivity and temperature electrodes. Expand or collapse the guide.\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:center;justify-content:space-between;gap:16px;padding:20px;background:#FF931A;color:#172b4d;cursor:pointer;border-radius:10px;font-weight:600;line-height:1.5;\"\u003e\u003cspan style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:block;flex:1;min-width:0;\"\u003e\u003cspan style=\"display:block;font-size:clamp(17px,2.6vw,21px);font-weight:700;line-height:1.35;\"\u003eChoose your Apera electrode\u003c\/span\u003e\u003cspan style=\"display:block;font-size:.88rem;font-weight:400;line-height:1.55;margin-top:5px;\"\u003e\u003cspan class=\"bts-sp-when-closed\"\u003eClick or tap to compare 6 electrode families\u003c\/span\u003e\u003cspan class=\"bts-sp-when-open\"\u003eCompare the models below - click or tap here to close\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"bts-sp-toggle\" style=\"display:flex;align-items:center;justify-content:center;flex:0 0 38px;width:38px;height:38px;border:1px solid rgba(23,43,77,.35);border-radius:50%;background:#fff;color:#172b4d;font-size:27px;font-weight:400;line-height:1;\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cp class=\"bts-guide-availability\" style=\"font-family:'Open Sans',sans-serif;font-size:15px;line-height:1.6;color:#26332C;margin:12px 0;\"\u003eOnly published products are linked. Other cards provide model-comparison information and do not indicate current storefront availability.\u003c\/p\u003e\n\u003cdiv class=\"bts-sp-selector-inner\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;padding:20px;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:300;line-height:1.65;margin:0 0 18px;color:#26332C;\"\u003ePick the measurement, then the connector your meter uses (BNC, BNC\/RCA with temperature, or 8-pin) on that page. For application-specific pH electrodes, see the LabSen range.\u003c\/p\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003ca class=\"bts-apera-electrode-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-201-series-pc-body-ph-electrode-201-c-201dj-c-201t-s\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera 201 PC-Body pH\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-201-c-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003e201 PC-Body pH\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003e201-C · 201DJ-C · 201T-S\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eGeneral water pH\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eEconomical PC-body pH electrode; BNC, double-junction or 8-pin.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView 201 PC-Body pH →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"bts-apera-electrode-family-link\" data-bts-unpublished-product=\"10368016515370\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:default;\"\u003e\n\u003cimg alt=\"Apera 301 ORP\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-301pt-c-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003e301 ORP\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003e301Pt-C · 301Pt-S · 301DJ-C\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eORP \/ redox\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003ePlatinum ORP sensor; BNC, 8-pin or double-junction BNC.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;background:#F1F7F3;color:#5D6C63;\"\u003eModel comparison\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca class=\"bts-apera-electrode-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-2301-series-conductivity-electrode-k1-2301-c-2301t-f-2301t-s\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera 2301 Conductivity K=1\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2301-c-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003e2301 Conductivity K=1\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003e2301-C · 2301T-F · 2301T-S\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eConductivity, K=1\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003ePOM body, platinum black sensor; BNC, BNC\/RCA or 8-pin.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView 2301 Conductivity K=1 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cdiv aria-current=\"page\" class=\"bts-apera-electrode-family-link\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:2px solid #FF931A;background:#FFF9F0;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:default;\"\u003e\n\u003cimg alt=\"Apera 2401 Glass Conductivity\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003e2401 Glass Conductivity\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003e2401-C · 2401T-F\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eHigh-accuracy lab conductivity\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eGlass body, platinum chip in a cavity; BNC or BNC\/RCA.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;background:#F1F7F3;color:#5D6C63;\"\u003eCurrent item\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ca class=\"bts-apera-electrode-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-2310-series-high-range-conductivity-electrode-k10-2310-c-2310t-f\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera 2310 High-Range K=10\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2310-c-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003e2310 High-Range K=10\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003e2310-C · 2310T-F\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003eHigh range to 2,000 mS\/cm\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eK=10 platinum black ring for brines and concentrates.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView 2310 High-Range K=10 →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003ca class=\"bts-apera-electrode-family-link\" href=\"https:\/\/bluetigerscientific.com\/products\/apera-djs-0-1-pure-water-conductivity-electrode-k0-1-flow-cell\" rel=\"noopener noreferrer\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:flex;align-items:flex-start;gap:16px;flex:1 1 300px;min-width:0;max-width:100%;padding:18px;border:1px solid #e0e0e0;background:#fff;border-radius:9px;text-decoration:none;color:#26332C;transition:box-shadow .15s ease,transform .15s ease,border-color .15s ease;cursor:pointer;\" target=\"_blank\"\u003e\n\u003cimg alt=\"Apera DJS-0.1 Pure Water\" class=\"bts-sp-model-thumb\" decoding=\"async\" height=\"88\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-djs-0-1-c-main-20261018-mfr.webp?width=200\" style=\"display:block;width:88px;height:88px;flex:0 0 88px;object-fit:contain;background:#fff;border-radius:6px;box-sizing:border-box;\" width=\"88\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;flex:1;min-width:0;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:1.1rem;line-height:1.3;font-weight:700;color:#245B45;margin:0 0 3px;\"\u003eDJS-0.1 Pure Water\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.76rem;font-weight:400;line-height:1.5;color:#5D6C63;margin:0 0 9px;\"\u003eDJS-0.1-C · DJS-0.1-F\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.95rem;font-weight:600;line-height:1.5;color:#26332C;margin:0 0 6px;\"\u003ePure and ultrapure water\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;font-size:.86rem;font-weight:300;line-height:1.65;color:#26332C;margin:0 0 12px;\"\u003eK=0.1 with glass flow cell against airborne CO₂.\u003c\/p\u003e\n\u003cspan class=\"bts-sp-card-cta\" style=\"font-family:'Open Sans',sans-serif;box-sizing:border-box;display:inline-block;font-size:.85rem;font-weight:700;line-height:1.5;color:#172b4d;background:#FFF0DD;border-radius:5px;padding:6px 9px;\"\u003eView DJS-0.1 Pure Water →\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003ePick the version\u003cbr\u003ethat fits your meter.\u003c\/h2\u003e\n\u003cdiv aria-label=\"Version table\" role=\"region\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;overflow-x:auto;width:100%;max-width:100%;\" tabindex=\"0\"\u003e\u003ctable style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;width:100%;border-collapse:collapse;font-size:1rem;border:1px solid #e0e0e0;table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eVersion\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;background:#f5f5f5;text-align:left;padding:12px;font-size:1rem;font-weight:700;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eKey differences\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e2401-C · AI1308\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eConnector: BNC; Temperature sensor: None; Sensor: Platinum chip in cavity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:32%;font-weight:600;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003e2401T-F · AI1309\u003c\/td\u003e\n\u003ctd style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:12px;font-size:1rem;line-height:1.6;vertical-align:top;border:1px solid #e0e0e0;width:50%;overflow-wrap:anywhere;min-width:0;\"\u003eConnector: BNC\/RCA; Temperature sensor: 30 kΩ thermistor (ATC); Sensor: Platinum chip in cavity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003e2401-C requires a compatible conductivity BNC input with K=1.0 support. Apera explicitly lists 2401T-F for EC800, EC820, PC800, PC820, EC910, PC910, EC950, PC950, EC9500 and PC9500. Its BNC\/RCA connection includes a 30 kΩ thermistor; check the host’s range and settings.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003e\u003cstrong\u003e2401T-F\u003c\/strong\u003e fits Apera benchtop meters with BNC and RCA inputs: \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec800-benchtop-conductivity-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC800\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc800-benchtop-ph-conductivity-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePC800\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec820-benchtop-conductivity-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC820\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc820-benchtop-ph-conductivity-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePC820\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec910-benchtop-conductivity-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC910\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc910-benchtop-ph-conductivity-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePC910\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec950-benchtop-conductivity-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC950\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc950-benchtop-ph-conductivity-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePC950\u003c\/a\u003e, \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec9500-benchtop-conductivity-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC9500\u003c\/a\u003e and \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-pc9500-benchtop-ph-conductivity-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003ePC9500\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera 2401-C\" decoding=\"async\" height=\"548\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-body-2-20261018-mfr.webp?width=548\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-body-2-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-body-2-20261018-mfr.webp?width=548 548w\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"548\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eApera 2401-C.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eWhat makes it work.\u003c\/h2\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;align-items:center;gap:clamp(24px,4vw,48px);\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003ePlatinum chip sensor\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eA high-accuracy platinum chip inside a cavity structure for stable readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eGlass body\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eResists chemical corrosion in the lab.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 240px;min-width:0;padding:24px;background:#fff;border:1px solid #DCE6DF;border-radius:10px;\"\u003e\n\u003ch3 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.07rem;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eBuilt-in temperature sensor (2401T-F)\u003c\/h3\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eReads conductivity and temperature together for automatic temperature compensation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;flex:1 1 340px;min-width:0;\"\u003e\u003cfigure style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;margin:0;min-width:0;\"\u003e\u003cimg alt=\"Apera 2401T-F\" decoding=\"async\" height=\"1600\" loading=\"lazy\" sizes=\"(max-width:600px) calc(100vw - 80px), 560px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401t-f-body-2-20261018-mfr.webp?width=1000\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401t-f-body-2-20261018-mfr.webp?width=360 360w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401t-f-body-2-20261018-mfr.webp?width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401t-f-body-2-20261018-mfr.webp?width=1000 1000w\" style=\"display:block;width:100%;max-width:460px;height:auto;object-fit:contain;box-sizing:border-box;margin:0 auto;\" width=\"1600\"\u003e\u003cfigcaption style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.86rem;line-height:1.65;color:#5D6C63;margin-top:12px;\"\u003eApera 2401T-F.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCheck the specifications.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eAll versions: range 0 to 200 mS\/cm; cell constant K = 1.0; sensor Platinum chip in cavity; body Glass; dimensions Ø12 × 145 mm.\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eThe full specification table, version by version, is in the Product Specifications tab.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eCare and storage.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eRinse between samples and store the sensor in its cap filled with distilled or deionized water, as the 2401 manuals specify. Do not rub the sensing element. For organic residues use warm detergent water; for calcium or magnesium deposits the manuals specify 10% citric acid. Rinse thoroughly and recalibrate after cleaning.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:clamp(28px,5vw,56px) 0;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eRelated items.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eApera ships these in: \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec950-benchtop-conductivity-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC950\u003c\/a\u003e (2401T-F), \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec9500-benchtop-conductivity-meter-kit-with-testbench\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC9500\u003c\/a\u003e (2401T-F), \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-ec820-benchtop-conductivity-meter-kit\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eEC820\u003c\/a\u003e (2401T-F).\u003c\/p\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCalibrate with \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-1413-us-cm-conductivity-calibration-standard\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003e1413 µS\/cm standard\u003c\/a\u003e, or \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-84-us-cm-conductivity-calibration-standard\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003e84 µS\/cm\u003c\/a\u003e and \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/apera-12-88-ms-cm-conductivity-calibration-standard\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003e12.88 mS\/cm\u003c\/a\u003e for low and high ranges.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"bts-apera-2401-faq\" style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px 0;line-height:1.15;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003e2401 Glass Conductivity buyer questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow do I choose between 2401-C and 2401T-F?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eChoose 2401-C for a compatible conductivity BNC input without a built-in temperature channel. Choose 2401T-F when your compatible meter uses BNC for conductivity and RCA for its 30 kΩ temperature sensor.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhich Apera meters are listed for 2401T-F?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eApera's standalone page lists EC800, EC820, PC800, PC820, EC910, PC910, EC950, PC950, EC9500 and PC9500. Check your exact meter's range and settings as well as its connectors.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat is the sensor design?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 2401 family uses a platinum sensing element within a cavity structure in a glass body. Apera describes this design as improving measurement stability for laboratory conductivity work.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eWhat conductivity range and cell constant are specified?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003e2401-C and 2401T-F are K=1.0 probes with a specified range up to 200 mS\/cm. The host meter must support the required range; fitting the probe does not change the meter's limits.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow large are the probes?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eBoth 2401 manuals specify a 12 mm diameter, 145 mm body length and a 3 ft cable. Handle the glass body and sensing cavity carefully.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eDoes the 2401-C compensate for temperature automatically?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eNot by itself. It has no temperature sensor. Use a temperature measurement method supported by your meter, or choose 2401T-F with its built-in thermistor and the appropriate host connection.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eHow should I store a 2401 conductivity probe?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 2401-C and 2401T-F manuals say to store the sensor in its cap filled with distilled or deionized water. Do not substitute pH-electrode KCl storage instructions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:10px;background:white;\"\u003e\u003csummary style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:14px 16px;cursor:pointer;font-weight:600;font-size:1rem;line-height:1.15;\"\u003eShould I brush or rub the sensing cavity?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:.97rem;line-height:1.6;margin:0;\"\u003eDo not rub the sensor. Rinse between measurements; the manuals specify warm detergent water for organic residues and 10% citric acid for calcium or magnesium deposits. Rinse thoroughly and recalibrate after cleaning.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;padding:28px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:12px;\"\u003e\u003ch2 style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:clamp(24px,4vw,34px);font-weight:600;line-height:1.2;letter-spacing:-.02em;color:#245B45;margin:0 0 20px;\"\u003eConfirm the exact configuration before ordering.\u003c\/h2\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-weight:300;box-sizing:border-box;font-size:1rem;line-height:1.75;margin:0 0 16px;\"\u003eCheck the version and catalog number (AI1308 \/ AI1309) against your meter, then return to the live price and ordering controls.\u003c\/p\u003e\n\u003ca href=\"#\" style=\"color:#245B45;text-decoration:underline;font-weight:600;\"\u003eBack to price and ordering ↑\u003c\/a\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"2401-C – BNC","offer_id":53011976716586,"sku":"BTS-AI1308","price":89.0,"currency_code":"USD","in_stock":true},{"title":"2401T-F – BNC\/RCA with temp sensor","offer_id":53011976749354,"sku":"BTS-AI1309","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/apera-2401-c-main-20261018-mfr.webp?v=1792352275","url":"https:\/\/bluetigerscientific.com\/products\/apera-2401-series-glass-conductivity-electrode-k1-2401-c-2401t-f","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}