{"product_id":"accucold-arg8pv-crt-8-cu-ft-glass-door-controlled-room-temperature-cabinet","title":"Accucold ARG8PV-CRT 8 Cu. Ft. Glass-Door Controlled Room Temperature Cabinet","description":"\u003cdiv class=\"bts-acc acc-pf-description\" id=\"acc-details\" style=\"font-family:Open Sans,Arial,sans-serif;color:#13314e;background:#fff\"\u003e\n\u003cnav aria-label=\"Product information\" class=\"acc-jump\"\u003e\u003ca data-acc-tab=\"details\" href=\"#acc-details\"\u003eBuying guide\u003c\/a\u003e\u003ca href=\"#acc-monitoring\"\u003eMonitoring choices\u003c\/a\u003e\u003ca href=\"#acc-fit\"\u003eWill it fit?\u003c\/a\u003e\u003ca data-acc-tab=\"specs\" href=\"#acc-specifications\"\u003eSpecifications\u003c\/a\u003e\u003ca data-acc-tab=\"manuals\" href=\"#acc-documents\"\u003eManuals \u0026amp; brochures\u003c\/a\u003e\u003ca href=\"#acc-faq\"\u003eBuyer FAQs\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection class=\"acc-story-hero\"\u003e\u003cdiv\u003e\n\u003cp class=\"acc-eyebrow\"\u003eControlled room temperature \/ ARG8PV-CRT\u003c\/p\u003e\n\u003ch2\u003eMake room for seven shelves in a 50-inch-tall cabinet.\u003c\/h2\u003e\n\u003cp\u003eThe Accucold ARG8PV-CRT is an 8 cu. ft. glass-door cabinet for medications whose labels permit controlled room temperature storage. It operates at 68-77°F (20-25°C) and arrives preset to 72°F. The 50-inch cabinet gives staff a direct view of stock through double-pane tempered glass before opening the door.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is CRT storage, not 2-8°C vaccine refrigeration.\u003c\/strong\u003e Check every product's label and your facility procedures before assigning inventory. A room-temperature cabinet does not make every medication or vaccine compatible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"acc-figure\"\u003e\u003cimg alt=\"ARG8PV-CRT OEM empty front view, glass door closed\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 760px) 90vw, 850px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-hero.webp?v=1795047472\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-hero.webp?v=1795047472\u0026amp;width=480 480w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-hero.webp?v=1795047472\u0026amp;width=800 800w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-hero.webp?v=1795047472\u0026amp;width=1600 1600w\" width=\"800\"\u003e\u003cfigcaption\u003eExact-model manufacturer cabinet photograph. No stored products are included.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e\n\u003csection aria-label=\"Key CRT facts\" class=\"acc-spec-strip\"\u003e\u003cdiv\u003e\n\u003cstrong\u003e8 cu. ft.\u003c\/strong\u003e\u003cspan\u003ePublished cabinet capacity\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e68-77°F\u003c\/strong\u003e\u003cspan\u003e20-25°C adjustable CRT range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e72°F preset\u003c\/strong\u003e\u003cspan\u003eSeven adjustable wire shelves\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection class=\"acc-section\"\u003e\u003cdiv class=\"acc-section-heading\"\u003e\n\u003cp class=\"acc-eyebrow\"\u003eApplication first\u003c\/p\u003e\n\u003ch2\u003eSeparate ambient stock from cold-chain inventory.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cp\u003eStart with the required storage condition, then plan the shelf map. Reserve this cabinet for materials that permit the selected controlled room temperature. Separate incoming stock, active inventory and short-dated packages using a layout staff can repeat. Published capacity is not a promise of a specific package count.\u003c\/p\u003e\n\u003cdiv class=\"acc-three\"\u003e\n\u003carticle class=\"acc-info-card\"\u003e\u003ch3\u003ePlan the shelf positions\u003c\/h3\u003e\n\u003cp\u003eSeven adjustable plastic-coated wire shelves have 1\/2-inch mounting positions. Choose an upright front lip for smaller items or a flat surface for larger packages. Leave airflow routes clear.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"acc-info-card\"\u003e\u003ch3\u003eManage access\u003c\/h3\u003e\n\u003cp\u003eA factory keyed lock and two keys are standard. The handle has a silver-ion antimicrobial coating. These features support access planning; they do not replace cleaning procedures, stock controls or staff accountability.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"acc-info-card\"\u003e\u003ch3\u003eUse the door deliberately\u003c\/h3\u003e\n\u003cp\u003eLocate packages through the double-pane tempered glass before opening the door. The standard right-hand door is self-closing. Reversal removes self-closing, so review handing and factory monitoring together.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection class=\"acc-section acc-split\"\u003e\u003cfigure class=\"acc-figure\"\u003e\u003cimg alt=\"ARG8PV-CRT manufacturer glycol-buffered probe detail\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 760px) 90vw, 850px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-detail.webp?v=1795047472\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-detail.webp?v=1795047472\u0026amp;width=480 480w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-detail.webp?v=1795047472\u0026amp;width=800 800w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-detail.webp?v=1795047472\u0026amp;width=1600 1600w\" width=\"900\"\u003e\u003cfigcaption\u003eIncluded product sensing is distinct from optional calibrated recording.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv\u003e\n\u003cdiv class=\"acc-section-heading\"\u003e\n\u003cp class=\"acc-eyebrow\"\u003eSensing and circulation\u003c\/p\u003e\n\u003ch2\u003eRead the product response, not just a rush of room air.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe included product-temperature probe sits in a glycol-filled bottle to better simulate stored-product temperature. A separate air sensor supports temperature control. Forced-air cooling uses two internal fans; automatic adjustable-cycle defrost helps limit temperature spikes and ice buildup.\u003c\/p\u003e\n\u003cp\u003eAccucold lists a 68 to 86°F ambient room range but does not specify active heating. Do not treat this as a warming cabinet or assume it will raise cold contents to the chosen setpoint. Have Accucold review any site that needs heating or falls outside the published room conditions.\u003c\/p\u003e\n\u003cp\u003eThe published ±1.5°C variation is based on the maximum deviation of an NTC sensor in a 1 oz. vial near the chamber center during a 24-hour test. It is not a guarantee for every shelf position, load or operating condition.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection class=\"acc-section acc-split\"\u003e\u003cdiv\u003e\n\u003cdiv class=\"acc-section-heading\"\u003e\n\u003cp class=\"acc-eyebrow\"\u003eControl and response\u003c\/p\u003e\n\u003ch2\u003eBuild a response routine around the reading.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe external microprocessor controller allows routine checks without opening the door. Current and resettable min\/max temperatures can be viewed in Celsius or Fahrenheit to the nearest tenth of a degree. The manufacturer describes min\/max updates in 15-minute increments. Standard C\/F capability does not require a paid conversion.\u003c\/p\u003e\n\u003cp\u003eTemperature, door-open, sensor-failure and power-failure alarms help staff identify conditions needing investigation. The battery-powered power-failure alarm is not backup temperature control. Rear dry alarm contacts can connect to a separate alarm system, but do not send messages on their own. Define who responds after hours before loading stock.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"acc-figure\"\u003e\u003cimg alt=\"ARG8PV-CRT OEM CRT controller and keyed lock\" height=\"800\" loading=\"lazy\" sizes=\"(max-width: 760px) 90vw, 850px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-control.webp?v=1795047472\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-control.webp?v=1795047472\u0026amp;width=480 480w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-control.webp?v=1795047472\u0026amp;width=800 800w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-control.webp?v=1795047472\u0026amp;width=1600 1600w\" width=\"1200\"\u003e\u003cfigcaption\u003eManufacturer control detail from the exact-SKU gallery. Displayed reading is illustrative, not a different operating range.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e\n\u003csection class=\"acc-section acc-soft\" id=\"acc-monitoring\"\u003e\u003cdiv class=\"acc-section-heading\"\u003e\n\u003cp class=\"acc-eyebrow\"\u003eIncluded versus optional\u003c\/p\u003e\n\u003ch2\u003eSpecify ambient-range recording separately.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe buffered product probe, air sensor, local alarms, remote contacts and probe port are standard. A NIST-calibrated data logger or activated cloud service is not included. DL2B is the factory USB logger request; the related logger's published -45 to +120°C measurement range includes 20-25°C CRT storage.\u003c\/p\u003e\n\u003cp\u003eDLPWCRTH is the manufacturer-listed factory CRT temperature\/humidity monitoring request. Confirm the complete installed configuration, calibration scope, availability, activation, cellular coverage and recurring service terms before ordering. A separate aftermarket kit is not included or equivalent to factory-installed equipment.\u003c\/p\u003e\n\u003cdiv aria-label=\"Included and optional CRT monitoring\" class=\"acc-three\"\u003e\n\u003carticle class=\"acc-info-card\"\u003e\u003ch3\u003eIncluded sensing and alarms\u003c\/h3\u003e\n\u003cp\u003eBuffered product sensing and separate air sensing inform the controller. Local alarms require a staff response plan.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"acc-info-card\"\u003e\u003ch3\u003eDL2B factory USB logging\u003c\/h3\u003e\n\u003cp\u003eRequest calibrated recording for the intended CRT temperature. Confirm calibration points and alarm settings.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"acc-info-card\"\u003e\u003ch3\u003eDLPWCRTH factory monitoring\u003c\/h3\u003e\n\u003cp\u003eRequest cloud-based CRT temperature and humidity monitoring. Confirm the installed system, coverage, activation and service terms.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eA min\/max display is not a downloadable temperature log.\u003c\/strong\u003e Dry contacts need separate alarm equipment, and the power-failure alarm does not provide backup temperature control.\u003c\/p\u003e\n\u003cdiv data-acc-upgrades=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003eChoose one monitoring request at a time. A new optional choice replaces the prior request. Return to Standard CRT controls to remove the optional selection; factory requests remain subject to a reviewed quote. No loose-kit price is presented as installed equipment.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection class=\"acc-section\" id=\"acc-fit\"\u003e\u003cdiv class=\"acc-section-heading\"\u003e\n\u003cp class=\"acc-eyebrow\"\u003eWill it fit?\u003c\/p\u003e\n\u003ch2\u003eAllow for ventilation, the handle and retrieval space.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe cabinet measures 50 inches high × 23.38 inches wide × 24.38 inches deep. Handle depth is 26.13 inches. With the door at 90°, depth is 46.5 inches and open-door width is 23.88 inches. Check the full route and leave room for door swing and retrieval.\u003c\/p\u003e\n\u003cfigure class=\"acc-figure acc-fit-guide\"\u003e\u003ca aria-label=\"Enlarge ARG8PV-CRT height, width and depth diagram\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-three-axis-fit.webp?v=1795047472\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"ARG8PV-CRT cabinet dimensions with labelled navy height, green width and orange depth arrows: 50 inches high, 23.38 inches wide, 24.38 inches cabinet depth.\" height=\"1800\" loading=\"lazy\" sizes=\"(max-width: 760px) 90vw, 850px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-three-axis-fit.webp?v=1795047472\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-three-axis-fit.webp?v=1795047472\u0026amp;width=480 480w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-three-axis-fit.webp?v=1795047472\u0026amp;width=800 800w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-three-axis-fit.webp?v=1795047472\u0026amp;width=1600 1600w\" width=\"1600\"\u003e\u003c\/a\u003e\u003cdiv aria-label=\"Published cabinet dimensions\" style=\"display:flex;flex-wrap:wrap;justify-content:center;gap:8px 24px;margin:14px 0 8px;font:600 14px\/1.6 Open Sans,Arial,sans-serif\"\u003e\n\u003cspan style=\"color:#13314E\"\u003eHeight: 50 in.\u003c\/span\u003e\u003cspan style=\"color:#245B45\"\u003eWidth: 23.38 in.\u003c\/span\u003e\u003cspan style=\"color:#D88920\"\u003eCabinet depth: 24.38 in.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cfigcaption\u003eTap the diagram to enlarge. Published cabinet height: 50 inches. Freestanding indoor installation only. Allow at least 5 inches at back, top and each side, and keep the front vent clear. Depth with handle: 26.13 inches. Depth with door open 90°: 46.5 inches. Confirm final setup, packed dimensions and installation clearances separately.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cp\u003eThis non-BI model is for freestanding indoor use, not built-in installation. The CRT manual requires at least 5 inches at the back, top and each side. Keep the front vent unobstructed, with access to rear contacts and the right-side probe port.\u003c\/p\u003e\n\u003cp\u003eProvide a dedicated grounded 115 V AC, 60 Hz outlet for the hospital-grade green-dot plug. Published current is 1.4 A. After unpacking, leave the unit upright for at least two hours, then run it for at least 24 hours to stabilize before use.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection class=\"acc-section acc-split\" id=\"acc-delivery\"\u003e\u003cdiv\u003e\n\u003cdiv class=\"acc-section-heading\"\u003e\n\u003cp class=\"acc-eyebrow\"\u003eReceiving and delivery\u003c\/p\u003e\n\u003ch2\u003eMeasure the packed route separately.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cp\u003eCabinet weight is 166 lb. The supplier export lists 209.5 lb packed and 71.5 H × 31 W × 31 D inches. Verify final packaging, door widths, turning space, elevators and unloading capability.\u003c\/p\u003e\n\u003cp\u003eAccucold currently estimates 2 to 3 days to ship the standard cabinet. This is supplier dispatch guidance, not a delivery-date promise or a warehouse count. Confirm lead time for factory options.\u003c\/p\u003e\n\u003cp\u003eFSI lists LTL freight service with supplier overboxing and a custom skid for this model. Checkout retains the original dock-delivery and liftgate options for eligible orders. Multiple-unit or mixed-equipment orders may use freight services. Alaska, Hawaii, US territories and international destinations require a quote.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalifornia recycling fee:\u003c\/strong\u003e Accucold identifies this cabinet as containing an embedded lithium-ion battery. The California Covered Battery-Embedded Waste Recycling Fee applies to qualifying retail purchases effective January 1, 2026: 1.5% of retail price, capped at $15. Recycle the product and battery through an appropriate program at end of life. Do not discard in household trash or incinerate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"acc-figure\"\u003e\u003cimg alt=\"ARG8PV-CRT OEM empty glass-door cabinet at a three-quarter angle\" height=\"1200\" loading=\"lazy\" sizes=\"(max-width: 760px) 90vw, 850px\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-gallery-2.webp?v=1795047472\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-gallery-2.webp?v=1795047472\u0026amp;width=480 480w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-gallery-2.webp?v=1795047472\u0026amp;width=800 800w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-gallery-2.webp?v=1795047472\u0026amp;width=1600 1600w\" width=\"1200\"\u003e\u003cfigcaption\u003eCabinet photography is not a scale drawing. Confirm final packaging and the receiving route.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/section\u003e\n\u003csection class=\"acc-section acc-faq\" id=\"acc-faq\"\u003e\u003cdiv class=\"acc-section-heading\"\u003e\n\u003cp class=\"acc-eyebrow\"\u003eBuyer questions\u003c\/p\u003e\n\u003ch2\u003eDetails that help you decide\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdetails\u003e\u003csummary\u003eIs this a vaccine cold-storage refrigerator?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eNo. ARG8PV-CRT is a controlled room temperature cabinet with a 68-77°F (20-25°C) range, preset to 72°F. It is not a 2-8°C refrigerator. Use it only for medication or pharmaceutical products whose labeled storage requirements match the intended CRT conditions. Follow each product label and your facility procedures.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat shelves and door does it include?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eThe 8 cu. ft. cabinet has seven adjustable plastic-coated wire shelves and a double-pane tempered glass door for viewing stock without opening it. Check package dimensions and leave airflow routes clear.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes it actively heat as well as cool?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eAccucold specifies forced-air cooling with two internal fans and an ambient room range of 68 to 86°F, but does not specify active heating. Ask Accucold to review any site requiring heating or outside the published conditions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan it be recessed into casework?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eNo. This non-BI CRT model is for freestanding indoor use. The CRT manual requires at least 5 inches at the back, top and each side, with the front unobstructed. Allow door-opening and service space too.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan staff view Fahrenheit without a paid upgrade?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eYes. Celsius\/Fahrenheit display capability is standard. The CRT manual explains protected controller settings. The cabinet is preset to 72°F; a standard display and resettable min\/max reading are not a downloadable temperature log.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs calibrated recording included?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eNo. Standard buffered product sensing, air sensing and alarms control the cabinet. DL2B factory USB logging is optional; its related logger has a -45 to +120°C measurement range covering CRT storage. DLPWCRTH is the CRT-specific factory-listed monitoring request. Confirm calibration, factory code, availability and service terms. Separate aftermarket kits are not installed equipment.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDo the standard contacts send cellular alerts?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eNo. Rear volt-free dry contacts require a separate alarm system. A probe port supports additional monitoring equipment. Connected alerts need separately specified equipment and activated service; the power-failure alarm does not maintain cabinet temperature.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the door swing be changed?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eThe standard right-hand self-closing base door is user-reversible following the CRT manual, but reversal removes self-closing. Doors with the DL2B logger suffix are not user-reversible. Request LHD and confirm monitoring combinations before ordering.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat should I plan for receiving and warranty service?\u003c\/summary\u003e\u003cdiv\u003e\u003cp\u003eCabinet weight is 166 lb. Supplier packed shipping is 209.5 lb at 71.5 H × 31 W × 31 D inches. Blue Tiger handles purchase and order-return requests. Accucold\/FSI handles authorized warranty service under its written terms: two-year limited parts and labor in the contiguous 48 US states and five-year compressor coverage, with replacement labor excluded.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection class=\"acc-bottom-cta\"\u003e\u003cdiv\u003e\n\u003cp class=\"acc-eyebrow\"\u003eEquipment and configuration\u003c\/p\u003e\n\u003ch2\u003eBring the complete CRT requirement together.\u003c\/h2\u003e\n\u003cp\u003eReview the drug-label storage range, monitoring, door swing and receiving needs in one ARG8PV-CRT-specific proposal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbutton class=\"acc-primary-quote\" data-acc-quote=\"\" disabled type=\"button\"\u003eRequest a Quote\u003c\/button\u003e\u003c\/section\u003e\n\u003c\/div\u003e\n","brand":"Accucold","offers":[{"title":"Default Title","offer_id":53656021926186,"sku":"ARG8PV-CRT","price":4554.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-arg8pv-crt-gallery-1.webp?v=1795047472","url":"https:\/\/bluetigerscientific.com\/products\/accucold-arg8pv-crt-8-cu-ft-glass-door-controlled-room-temperature-cabinet","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}