{"title":"Safety Cabinets \u0026 Lockers","description":"","products":[{"product_id":"across-international-nsf-certified-3-ft-class-ii-type-a2-biosafety-cabinet-1","title":"Class II Type A2 Biosafety Cabinet-NSF Certified, 3 Ft","description":"\u003cp\u003eA \u003cstrong\u003ebiosafety cabinet\u003c\/strong\u003e, also called a biological safety cabinet or microbiological safety cabinet—is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level.\u003cbr\u003e\u003cbr\u003eThe primary purpose of a BSC is to serve as a means to protect the laboratory worker and the surrounding environment from pathogens. All exhaust air is HEPA-filtered as it exits the biosafety cabinet, removing harmful bacteria and viruses. This is in contrast to a laminar flow clean bench, which blows unfiltered exhaust air towards the user and is not safe for work with pathogenic agents. Neither are most BSCs safe for use as fume hoods. Likewise, a fume hood fails to provide the environmental protection that HEPA filtration in a BSC would provide. However, most classes of BSCs have a secondary purpose to maintain the sterility of materials inside (the \"product\").\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(55, 114, 255);\"\u003e\u003cstrong\u003eClass I\u003c\/strong\u003e \u003c\/span\u003ecabinets provide personnel and environmental protection but no product protection. In fact, the inward flow of air can contribute to contamination of samples. Inward airflow is maintained at a minimum velocity of 75 ft\/min(0.38 m\/s). These BSCs are commonly used to enclose specific equipment (e.g. centrifuges) or procedures (e.g. aerating cultures) that potentially generate aerosols. BSCs of this class are either ducted (connected to the building exhaust system) or unducted (recirculating filtered exhaust back into the laboratory.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(55, 114, 255);\"\u003e\u003cstrong\u003eClass II\u003c\/strong\u003e\u003c\/span\u003e cabinets provide both kinds of protection (of the samples and of the environment) since makeup air is also HEPA-filtered. There are five types: Type A1 (formerly A), Type A2 (formerly A\/B3), Type B1, Type B2 and Type C1. Each type's requirements are defined by NSF International Standard 49, which in 2002 reclassified A\/B3 cabinets (classified under the latter type if connected to an exhaust duct) as Type A2, and added the Type C1 in the 2016 standard. About 90% of all biosafety cabinets installed are Type A2 cabinets.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        .center {\n            display: flex;\n            justify-content: center;\n            align-items: center;\n            height: 100vh; \/* This will center it vertically *\/\n        }\n    \u003c\/style\u003e\n\u003cdiv style=\"text-align: center;\" class=\"center\"\u003e\u003ciframe width=\"456\" height=\"310\" src=\"https:\/\/www.youtube.com\/embed\/LInJnk-YVUQ\" title=\"Biological Safety Cabinet (BSC): How it Works to Protect You  | Across International\"\u003e\n        \u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"508\" width=\"492\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/e_BC4-Com_1.png\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cspan style=\"color: rgb(55, 114, 255);\"\u003e\u003cstrong\u003eAi Class II Type A2 biosafety cabinet features\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eNSF certified\u003c\/li\u003e\n\u003cli\u003eGreat for COVID-19 specimen handling\u003c\/li\u003e\n\u003cli\u003eMotorized front glass viewing window with remote foot switch\u003c\/li\u003e\n\u003cli\u003eDual HEPA filters with life indicator\u003c\/li\u003e\n\u003cli\u003eUV light life indicator\u003c\/li\u003e\n\u003cli\u003eWaterproof in-chamber power sockets\u003c\/li\u003e\n\u003cli\u003eLarge LCD display\u003c\/li\u003e\n\u003cli\u003eEasy-to-clean stainless steel chamber\u003c\/li\u003e\n\u003cli\u003eSpecial treated unit housing with anti-mold and antiseptic coating\u003c\/li\u003e\n\u003cli\u003eAuto start and stop function (e.g. UV lights)\u003c\/li\u003e\n\u003cli\u003eAutomatic flow speed adjustment\u003c\/li\u003e\n\u003cli\u003ePneumatic front panel supports for easy maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5 style=\"text-align: center;\"\u003e\u003cspan style=\"color: rgb(55, 114, 255);\"\u003e\u003cstrong\u003eWhat's in the Crate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv class=\"ai-table-container\"\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003ctable class=\"ai-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Description\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003cth\u003ePart Image\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eAi 3 Ft Biosafety Cabinet\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/BC3-front-L-remote.jpg\" alt=\"\" width=\"66\" height=\"103\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eDetachable armrest\u003c\/td\u003e\n\u003ctd\u003e2 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg height=\"44\" width=\"50\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BSC-Armrest.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eFoot switch for raising \u0026amp; lowering the front glass panel\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg height=\"51\" width=\"80\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BiosafetyFootSwitch_Cut.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eRemote\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg height=\"50\" width=\"23\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BC4-remote.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eBottom drain port assembly\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg height=\"50\" width=\"111\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BC4-DrainValve-parts.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eBackup UV light tube\u003c\/td\u003e\n\u003ctd\u003e1 pcs\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BC4-lightBulb.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHex wrench\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.thumbswysiwyg\/Hex_wrench.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eFront glass panel motor adjusting tool, plastic\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg height=\"15\" width=\"250\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BC4-MotorAdjust.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eFuses (for glass panel control board)\u003c\/td\u003e\n\u003ctd\u003e9 pcs\u003c\/td\u003e\n\u003ctd\u003e\n\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BC4-fuse.jpg\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/BC4-fuse.jpg\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/acrossinternational.com\/media\/BC4-fuse.jpg\" alt=\"\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eHex Bolts\u003c\/td\u003e\n\u003ctd\u003e7 pcs\u003c\/td\u003e\n\u003ctd\u003e\n\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.thumbswysiwyg\/Hex_Bolt.jpg\"\u003e\u003cimg alt=\"\" src=\"https:\/\/acrossinternational.com\/media\/BC4-bolt.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eBig, small washer and lock washer\u003c\/td\u003e\n\u003ctd\u003e7 sets\u003c\/td\u003e\n\u003ctd\u003e\n\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.thumbswysiwyg\/lock_washer.jpg\"\u003e\u003cimg alt=\"\" src=\"https:\/\/acrossinternational.com\/media\/BC4-3washers.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStandard 110V Power Cord\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg height=\"47\" width=\"104\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.thumbswysiwyg\/power.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eStand Assembly (Set)\u003cbr\u003eLegs (2 wheels casters\/leg) x 2\u003cbr\u003eLeg back panel x 1\u003c\/td\u003e\n\u003ctd\u003e3 pcs\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cimg height=\"91\" width=\"98\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.thumbswysiwyg\/legs_1.jpg\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"88\" width=\"139\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.thumbswysiwyg\/leg_back_panel.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left;\"\u003eUser's manual\u003c\/td\u003e\n\u003ctd\u003e1 pc\u003c\/td\u003e\n\u003ctd\u003e\u003cimg height=\"42\" width=\"59\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/user-manual.jpg\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eCaution! Installation requires a forklift or a crane.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eAttention! Steps before and after using the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eStep 1: Fully close the front glass panel, turn on UV light for 30 mins (you can use the timer setting). Users should leave the room during this disinfection period.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eStep 2. Raise the glass panel to recommended opening height, turn on air circulation for 10 minutes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eAfter operation is done, fully close the glass panel and turn on UV light for another 30 minutes for decontamination.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/e_BC4-Areas_1.gif\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eIMPORTANT GUIDELINES USING A BSC\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eNo flammable and explosive substances (Building up of flammable material may cause an internal fire or explosion)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eNo volatile chemicals (May cause damage to HEPA filters to the point where it allows particles to leak through)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eNo toxic chemicals or materials (May reach room occupants)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eNo open flame (Will disrupts air flow patterns)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eMinimal use (10mL or less) of decontaminant, such as 70% isopropyl or ethyl alcohol is allowed.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eWe recommend using the following for disinfecting the surfaces of a BSC, depending on the agent to be controlled: Sodium hypochlorite (bleach), Ilodophors (Wescodyne), Phenolics (Hilphene, Vespene) and Quaternary ammonium compounds (Conflikt, EndbacII)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eIf gaseous, vaporized or aerosolized chemicals must be generated in a BSC, you should assure yourself that the quantity being generated will NOT cause a flammable or toxic risk.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ccenter\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/e_BC4-DrainValve_1.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"655\" width=\"435\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/e_BC4-back-L_1.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"280\" width=\"436\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/e_BC4FB2-panelUp_1.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"719\" width=\"462\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/e_BC4-top_1.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Top Vent Duct Connector (70% recirculated internally, 30% discharged from top vent)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg height=\"358\" width=\"492\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/BiosafetyTopVent_Cut_1.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg height=\"433\" width=\"466\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/e_BC4-Remote_1.gif\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/BiosafetyFootSwitch_Cut_1.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"1345\" width=\"827\" alt=\"\" src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/BC3F-dim_1.gif\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.acrossinternational.com\/media\/.renditions\/NSF_Certificate.png\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/center\u003e\n\u003c\/div\u003e","brand":"Across International","offers":[{"title":"Default Title","offer_id":49792656638250,"sku":"BC-3F.110","price":8197.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bc-3f_0a367325-69f9-4da3-9a90-555b31ebaf3e.webp?v=1731823946"},{"product_id":"air-science-purair-bio-class-ii-a2-biological-safety-cabinet-bsc","title":"Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003ePurair® Bio Class II A2 Biological Safety Cabinets are NSF Listed and designed for optimum performance at 115V 60Hz. Each cabinet comes equipped with an Adjustable Height Base Stand on Levelers for flexibility and stability, a UV system for enhanced sterilization, two GFI outlets for added convenience, and one service fixture to meet all your laboratory needs.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BSC_2_F.svg?v=1737038593\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Purair BIO is a state-of-the-art Class II, Type A2 biosafety cabinet designed to meet stringent US and international standards, including NSF\/ANSI 49. Available in 36\", 48\", and 72\" sizes, it provides primary containment for handling biosafety agents at levels 1, 2, and 3. Its ergonomic design ensures ease of use, making it one of the narrowest BSCs on the market, which allows for easy passage through standard doorways.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/BSC_3_denoised.webp?v=1737037263\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Purair BIO features a single EC blower motor for reliable performance and lower maintenance costs. Enhanced protection is ensured with HEPA filtration of both downflow and exhaust paths, protecting the user, the work product, and the environment from cross-contamination. The cabinet also includes a user-friendly interface with a 10° angled window to reduce operator discomfort and fatigue.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/Bsc_4_enoised.webp?v=1737037290\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditionally, it can be equipped with a range of accessories to enhance its functionality and adaptability to various laboratory needs. Options include an exhaust plenum, IV bar hooks, and other optional components tailored to specific applications and requirements.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/AS_BSC_97e30657-20a3-43db-a377-53dd353b39d4.svg?v=1737035111\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Air Science","offers":[{"title":"36\" (3FT) Wide","offer_id":49846182773034,"sku":"AS-AHA-103-CA-B","price":8295.0,"currency_code":"USD","in_stock":true},{"title":"48\" (4FT) Wide","offer_id":49846182805802,"sku":"AS-AHA-133-CA-B","price":8495.0,"currency_code":"USD","in_stock":true},{"title":"72\" (6FT) Wide","offer_id":49846182838570,"sku":"AS-AHA-193-CA-A","price":8995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ASBSC.png?v=1737032704"}],"url":"https:\/\/bluetigerscientific.com\/collections\/safety-cabinets-lockers.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}