{"title":"Milwaukee Instruments Titrators \u0026 Test Kits","description":"\u003cp\u003eBrowse titrators \u0026amp; test kits from Milwaukee Instruments. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"milwaukee-mi456us-pro-mini-titrator-for-titratable-acidity-in-wine","title":"Milwaukee MI456US PRO Mini Titrator for Titratable Acidity in Wine","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px;\n                        font-family: 'Open Sans', sans-serif; font-weight: 300;\n                        color: #333; background: #fff; font-size: 0.95rem;\n                        box-sizing: border-box;\"\u003e\n              \u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e\n                \u003cdiv class=\"productView-desc-content\" itemprop=\"description\"\u003e\n\n                \u003ch1\u003e\u003cstrong\u003eLab Grade. Accurate. Simple. Automated.\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe Milwaukee MI456US PRO TA Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The instrument comes with a preprogrammed analysis method designed for Total Titratable Acidity measurements on wine. The MI456US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade pH electrode. The MI456US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI456US uses a preprogrammed method and lab grade pH electrode combined with an algorithm to determine the end of the titration reaction.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe Milwaukee MI456 PRO TA Mini Titrator is preferred by wine makers seeking results faster with lower costs and simple operation.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee PRO TA Mini Titrator offers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MI456 PRO Mini Titrator is accurate to 5% of the reading with a resolution of \u003cspan\u003e0.1 g\/L\u003c\/span\u003e with a range of \u003cspan\u003e0.0 to 25.0 g\/L of tartaric acid\u003c\/span\u003e. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade pH electrode.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSimplicity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MI456 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAutomated operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MI456 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI456 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation.\u003c\/p\u003e\n\u003ch2\u003eDesign features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEasy measurement: just measure the wine sample, add the reagents as directed, prepare pH probe and pump, add the stabilizer and start the titration by pressing the start button.\u003c\/li\u003e\n\u003cli\u003eRefillable, double junction lab grade pH electrode.\u003c\/li\u003e\n\u003cli\u003eAutomatic temperature compensation.\u003c\/li\u003e\n\u003cli\u003e700 rpm built-in stirrer.\u003c\/li\u003e\n\u003cli\u003eSimple and reliable peristaltic pump that ensure high dosing repeatability.\u003c\/li\u003e\n\u003cli\u003eCompact 8.2 x 8.4” footprint.\u003c\/li\u003e\n\u003cli\u003eBuilt-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface.\u003c\/li\u003e\n\u003cli\u003eReplacement Kit:  \u003cstrong\u003eMi556-KIT\u003c\/strong\u003e.  \u003cstrong\u003eIndividual Reagent Bottles\u003c\/strong\u003e.  \u003c\/li\u003e\n\u003cli\u003eReplacement pH electrode:  \u003cstrong\u003eMA919B\/1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCare and Use \u003c\/h2\u003e\n\u003cp\u003epH electrodes usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSensing bulb\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eReference junction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.\u003c\/p\u003e\n\u003cp\u003eYou can extend the life of your pH electrode in the following ways.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCleaning and Storage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAll pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code \u003cstrong\u003ePH-Main\u003c\/strong\u003e at checkout time!  This will be needed to help clean and condition the pH electrode before use!\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTo minimize clogging the pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.\u003c\/p\u003e\n\u003cp\u003eStoring in pH probe storage solution \u003cstrong\u003eMA9015\u003c\/strong\u003e or pH calibration buffers will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.\u003c\/p\u003e\n\u003cp\u003eThe best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCleaning an Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eResidue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution \u003cstrong\u003eMA9016\u003c\/strong\u003e. Also:\u003c\/p\u003e\n\u003cp\u003e1.  Inspect the electrode for damage or scratches, if present replace the electrode.\u003c\/p\u003e\n\u003cp\u003e2.  Inspect the cable.  The connection cable and insulation must be intact.\u003c\/p\u003e\n\u003cp\u003e3.  Connectors should be clean and dry.\u003c\/p\u003e\n\u003cp\u003e4.  Rinse off salt deposits with water or DI water.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your MI456 Mini-Titrator readings accurate. Also, calibrate after cleaning or a long period of storage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThank you for considering Milwaukee to help you take your results to the next level.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n                \u003c!-- snippet location product_description --\u003e\n\n            \u003c\/div\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":50549141111082,"sku":"BTS-MI456US","price":1104.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/MI456__63498.1610459585.jpg?v=1756586055"},{"product_id":"milwaukee-mi455us-pro-mini-titrator-for-sulfur-dioxide-in-wine","title":"Milwaukee MI455US PRO Mini Titrator for Sulfur Dioxide in Wine","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px;\n                        font-family: 'Open Sans', sans-serif; font-weight: 300;\n                        color: #333; background: #fff; font-size: 0.95rem;\n                        box-sizing: border-box;\"\u003e\n              \u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e\n                \u003cdiv class=\"productView-desc-content\" itemprop=\"description\"\u003e\n\n                \u003ch1\u003e\u003cstrong\u003eLab Grade. Accurate. Simple. Automated.\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe Milwaukee MI455US PRO SO₂ Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The MI455US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode. Using a modified Ripper method, this mini-titrator does not rely on color change but uses potentiometric detection. The MI455US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI455US uses a preprogrammed method and specialized ORP electrode combined with an algorithm to determine the end of the titration reaction.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe Milwaukee MI455 PRO SO\u003csub\u003e2\u003c\/sub\u003e Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee PRO SO\u003csub\u003e2\u003c\/sub\u003e  PRO Mini-Titrator offers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MI455 PRO Mini-Titrator is accurate to 5% of the reading with a resolution of 1 ppm with a range of 0-400 ppm. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSimplicity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MI455 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAutomated operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MI455 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI455 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation.\u003c\/p\u003e\n\u003ch2\u003eDesign features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure both free and total SO₂\u003c\/li\u003e\n\u003cli\u003eEasy measurement: just measure the wine sample, add the reagents as directed, prepare ORP probe and pump, add the stabilizer and start titration by pressing the start button.\u003c\/li\u003e\n\u003cli\u003eRefillable, double junction lab grade ORP electrode.\u003c\/li\u003e\n\u003cli\u003e700 rpm built-in stirrer.\u003c\/li\u003e\n\u003cli\u003eSimple and reliable peristaltic pump that ensure high dosing repeatability.\u003c\/li\u003e\n\u003cli\u003eCompact 8.2 x 8.4” footprint.\u003c\/li\u003e\n\u003cli\u003eBuilt-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface.\u003c\/li\u003e\n\u003cli\u003eReplacement Reagent Kit:  \u003cstrong\u003eMi555-KIT\u003c\/strong\u003e.  Individual bottle here: \u003cstrong\u003eIndividual\u003c\/strong\u003e \u003cstrong\u003eReagent Bottles\u003c\/strong\u003e. \u003c\/li\u003e\n\u003cli\u003eReplacement ORP Electrode:  \u003cstrong\u003eMA924B\/1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCare and Use \u003c\/h2\u003e\n\u003cp\u003eORP electrodes usually start performing poorly because of problems with the probe. The two parts of the ORP probe that cause problems are the glass sensing bulb and the reference junction.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSensing bulb\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe glass bulb loses sensitivity with use and will eventually fail. This is true of all ORP probes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eReference junction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the ORP electrode will no longer function.\u003c\/p\u003e\n\u003cp\u003eYou can extend the life of your ORP electrode in the following ways.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCleaning and Storage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAll ORP sensors have a limited life and response time gets longer with age. Properly maintaining your ORP electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code \u003cstrong\u003ePH-Main\u003c\/strong\u003e at checkout time! This will be needed to help clean and condition the pH electrode before use!\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTo minimize clogging the ORP probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.\u003c\/p\u003e\n\u003cp\u003eStoring in ORP probe storage solution \u003cstrong\u003eMA9015\u003c\/strong\u003e will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.\u003c\/p\u003e\n\u003cp\u003eThe best way to store the probe is with the probe's cap filled with storage solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCleaning an Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eResidue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution \u003cstrong\u003eMA9016\u003c\/strong\u003e. Also:\u003c\/p\u003e\n\u003cp\u003e1.  Inspect the electrode for damage or scratches, if present replace the electrode.\u003c\/p\u003e\n\u003cp\u003e2.  Inspect the cable.  The connection cable and insulation must be intact.\u003c\/p\u003e\n\u003cp\u003e3.  Connectors should be clean and dry.\u003c\/p\u003e\n\u003cp\u003e4.  Rinse off salt deposits with water or DI water.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThank you for considering Milwaukee to help you take your results to the next level.\u003c\/p\u003e\n\n                \u003c!-- snippet location product_description --\u003e\n\n            \u003c\/div\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":50549141373226,"sku":"BTS-MI455US","price":1104.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/MI455__37550.1610461247.jpg?v=1756586058"},{"product_id":"milwaukee-mt6003-n-p-k-soil-test-kit","title":"Milwaukee MT6003 N, P, K Soil Test Kit","description":"\u003cdiv style=\"max-width: 1400px; margin: 0 auto; padding: 40px 20px;\n                        font-family: 'Open Sans', sans-serif; font-weight: 300;\n                        color: #333; background: #fff; font-size: 0.95rem;\n                        box-sizing: border-box;\"\u003e\n              \u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e\n                \u003cdiv class=\"productView-desc-content\" itemprop=\"description\"\u003e\n\n                \u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Milwaukee MT6003 helps determine the q\u003c\/span\u003euality of plants and crops growth which depend greatly on physical and chemical properties of soil, that is on soil composition: minerals and organic matter, water, gases like oxygen and carbon dioxide and living being (primarily microorganisms such as fungi and bacteria). Soil is not only a support system, but also a nutritive source that supplies plants with water and nutrients. Each plant needs a particular soil composition, in which it can better express its potential growth. For this reason, a correct balance in soil components is fundamental to ensure an optimal crop growth.\u003c\/p\u003e\n\u003cp\u003eThe most important elements for plant growth are nitrogen (N), phosphorous (P) and potassium (K): for this reason they are called essential nutrient elements or macronutrients. These elements are usually added to the soil by fertilization. Other elements, the so called microelements are generally present in sufficient quantities in the soil and the plants need them in smaller doses.\u003c\/p\u003e\n\u003cp\u003eMilwaukee MT6003 NPK Soil Test Kit allows one to measure the concentration of the three elements N, P, K in a soil sample.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimple-to-use reagent kit.\u003c\/li\u003e\n\u003cli\u003ePre-made reagents for precision and ease-of-use.\u003c\/li\u003e\n\u003cli\u003eMarked with expiration date and lot number for traceability.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e5 test tubes, spoons, brush, tube stand, color cards, graduated card and instruction manual included.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n                \u003c!-- snippet location product_description --\u003e\n\n            \u003c\/div\u003e\n              \u003c\/div\u003e\n            \u003c\/div\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":50549141405994,"sku":"BTS-MT6003","price":93.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/MT6003__76520.1613244176.jpg?v=1756586059"}],"url":"https:\/\/bluetigerscientific.com\/collections\/milwaukee-instruments-titrators-test-kits.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}