{"title":"Meiji Techno Polarizing Microscopes","description":"\u003cp\u003eBrowse polarizing microscopes from Meiji Techno. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"meiji-techno-mt9930l-40x-400x-led-trinocular-polarizing-microscope","title":"Meiji Techno MT9930L LED Trinocular Polarizing Microscope","description":"\u003cdiv id=\"bts-meiji-mt9930-guide\" style=\"font-family:'Open Sans',Arial,sans-serif;font-weight:300;color:#26332C;max-width:1400px;margin:0 auto;box-sizing:border-box;padding:20px;\"\u003e\n\u003csection style=\"padding:26px;box-sizing:border-box;background:#13314E;border-radius:12px;margin-bottom:24px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.8rem;font-weight:600;letter-spacing:.12em;color:#B7D0BF;\"\u003eMEIJI TECHNO · POLARIZING MICROSCOPY\u003c\/p\u003e\n\u003ch2 style=\"font-size:2rem;line-height:1.2;font-weight:600;color:#fff;margin:14px 0;\"\u003eRead the structure.\u003cbr\u003eSee the material in a new light.\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#fff;\"\u003eFrom a prepared rock thin section to a polished opaque surface, the MT9930L brings transmitted and incident LED illumination together with strain-free optics. Explore optical character at the bench, then build your positioning and documentation workflow around the specimen.\u003c\/p\u003e\n\u003cp style=\"background:#fff;padding:12px;color:#13314E;border-radius:6px;font-weight:600;line-height:1.6;\"\u003e40×, 100× and 400× visual magnifications supplied. Camera and selected accessories are separate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cdiv style=\"padding:14px;background:#fff;border-radius:8px;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT9930L.webp?v=1730072325\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT9930L.webp?v=1730072325\" alt=\"MT9930L product photograph from the existing gallery.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:440px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMT9930L product photograph from the existing gallery. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eTransmitted + incident LED\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eKöhler illumination in the base and the included vertical illuminator: choose the optical path to suit transparent or opaque prepared specimens.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e40× \/ 100× \/ 400× supplied\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe 10× eyepieces pair with 4×, 10× and 40× strain-free Plan objectives. These are discrete visual settings—not a zoom.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003ePolarization, ready to explore\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eRotating stage, polarizer, analyzer, Bertrand lens and MA988 red\/quarter-wave\/clear slider are included. A camera and matched adapter are not included.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eWhat comes with the MT9930L?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eSupplied optical system\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMA953 trinocular head; one MA407CP 10× focusing crossline eyepiece and one MA407 10× eyepiece, both FN20; MA935 4×, MA936 10× and MA938 40× strain-free Plan objectives; centerable four-position nosepiece.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eSupplied polarization tools\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e360° rotating ceramic-coated stage with two clips; swing-out Abbe condenser; rotating transmitted polarizer; MA956\/05 graduated analyzer; focusable, centerable Bertrand lens; MA988 first-order red, quarter-wave and clear slider.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eSupplied illumination\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTransmitted LED and MA955LED vertical\/incident LED Köhler illumination, with an incident polarizer. Dust cover and centering tools are supplied. A region-appropriate cord is supplied; confirm destination requirements.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe supplied stage rotates; the MA299 X–Y attachment and MA945 point-counting attachment are separate choices. The trinocular head is camera-ready, not a camera package.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eThree specimens. Two illumination paths.\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose the optical path by the specimen on your bench.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:18px;align-items:stretch;\"\u003e\n\u003carticle data-meiji-application=\"thinsection\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt9930-thinsection.webp?v=1793909702\" alt=\"Application illustration: Rock thin sections. Not a microscope image.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eAPPLICATION ILLUSTRATION · NOT A MICROGRAPH\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eRock thin sections\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eTrace the fabric of a rock.\u003c\/strong\u003e Compare grains, boundaries and textures in a prepared thin section. Start in plane-polarized light, then cross the analyzer and rotate the stage to follow extinction, interference colors and twinning.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003eTransmitted work requires a thin, transparent preparation—not an intact opaque core.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle data-meiji-application=\"materials\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt9930-materials.webp?v=1793909702\" alt=\"Application illustration: Transparent materials. Not a microscope image.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eAPPLICATION ILLUSTRATION · NOT A MICROGRAPH\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eTransparent materials\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eLook for optical anisotropy.\u003c\/strong\u003e Examine suitably prepared polymer films, fibers, glass or crystalline materials for changes in optical appearance under crossed polars. Preparation can introduce strain; compare carefully and use an appropriate protocol.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003eInterference colors alone do not establish chemical identity or a calibrated stress measurement.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle data-meiji-application=\"incident\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt9930-incident.webp?v=1793909703\" alt=\"Application illustration: Opaque surfaces. Not a microscope image.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eAPPLICATION ILLUSTRATION · NOT A MICROGRAPH\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eOpaque surfaces\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eBring the light to the surface.\u003c\/strong\u003e Use the included vertical LED illuminator for appropriate polished, flat opaque ore or material surfaces. Select objectives suitable for the reflected-light specimen and its cover condition.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003eA rough bulk sample is not a transparent thin section. Higher-power incident objectives are separate; verify their specimen-cover specifications.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:.85rem;line-height:1.6;color:#526358;margin:12px 0 0;\"\u003eOriginal generated still-life illustrations, not micrographs or manufacturer photographs. They do not depict results captured with the MT9930L.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003ePPL, XPL or conoscopic? Choose the question first\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003ePPL · What does the grain look like?\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIn transmitted plane-polarized light, insert the polarizer; leave the analyzer and Bertrand lens out. Compare color, pleochroism, relief, cleavage and grain shape. Relief depends on the specimen and mounting medium.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eXPL · How does it change on rotation?\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eCross the polarizer and analyzer at 90° with the Bertrand lens out. Rotate the stage to examine extinction, interference colors and twinning. A dark grain is not automatically isotropic: an anisotropic grain can be at extinction.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eConoscopic · What does the interference figure show?\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse suitable transparent crystalline grains, transmitted convergent illumination, crossed polars and the supplied Bertrand lens. Center the optics, use the 40× objective and appropriate condenser aperture, then rotate the stage. A useful figure is not guaranteed for every grain or orientation; the standard objective limits the angular cone.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConoscopic observation is not performed under vertical illumination in the shared manual. These modes support trained interpretation, not automatic mineral chemistry or a guaranteed optical-sign determination.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 22px;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;background:#F1F7F3;border-radius:10px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eFrom preparation to interpretation\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e1 · Prepare the right specimen\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor transmitted petrography, use a flat, mounted rock thin section, typically around 25–30 µm, with an appropriate cover glass. Prepare films, fibers or crystals appropriately for their material; avoid preparation-induced strain. Preparation tools and consumables are separate.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e2 · Center and observe\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSet up illumination and center the stage\/objectives according to the manual. Start at low power in PPL; compare features under XPL while rotating the stage. Keep notes on grain orientation, thickness and mounting conditions.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e3 · Add a plate when useful\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe supplied MA988 slider offers first-order red, quarter-wave and clear positions. Addition\/subtraction can help interpret optical orientation or sign of elongation. Quantitative retardation work needs the appropriate compensator, calibration and method.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose the stage attachment for the work\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe standard rotating stage and clips are already supplied. Add one attachment when your workflow needs controlled positioning; these are alternatives, not a stack-on pair.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eMA299 · scan and reposition\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe attachable mechanical stage helps move slides in X–Y for routine scanning and repositioning.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eMA945 · structured point counting\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose the point-counting attachment for a modal-analysis workflow. Select plain MA945, not an attachment intended for another microscope brand. Counting intervals support a method; they do not establish accreditation.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cdiv data-bts-accessory-slot=\"mt9930-support\"\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe shared manual directs you to remove and store the supplied clips before fitting an optional stage attachment. Verify specimen and method requirements before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose optional optics around the specimen\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe supplied 4×, 10× and 40× objectives occupy three of four positions; one additional objective normally fits without swapping.\u003c\/p\u003e\n\u003cdiv class=\"product-specs-container\" style=\"width:100%;max-width:100%;box-sizing:border-box;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;border:1px solid #e0e0e0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eOptional component\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eWhen it helps\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eDecision check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA937 · 20× transmitted\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e200× visual with supplied eyepieces; a middle step between 100× and 400×.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eFor transmitted specimens; not the incident-light MA947.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA939 · 60× transmitted\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e600× visual with supplied eyepieces for finer-detail work.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eShort working distance demands careful clearance and focusing; not an oil objective.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA151\/35\/20 · 0.7× C-mount adapter\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eA possible documentation path for a compatible camera.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eConfirm camera model, C\/CS mount, sensor size and desired field. Manufacturer documents it with the exact MT9930L + HD2500T 2\/3-inch C-mount configuration; it is not universal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-bts-accessory-slot=\"mt9930-optics\"\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor opaque surfaces, a separately selected incident-light objective may be appropriate. MA947 is a 20× incident option, but manufacturer sources differ on its specimen-cover specification; confirm before ordering. The camera, adapter and software are separate from the bare microscope.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eThree practical buying paths\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e1 · Petrography at the eyepieces\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose the standard instrument for prepared thin sections and PPL\/XPL viewing. The Bertrand lens and MA988 plates are already supplied.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e2 · Repeatable positioning\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAdd MA299 for slide handling or MA945 for a point-counting workflow. Select the attachment for the job rather than both by default.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e3 · Detail or documentation\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConsider MA937 or MA939 for a transmitted-light magnification step. For imaging, choose a compatible camera and adapter only after checking the sensor, mount and field of view.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThese are component selection paths, not bundled SKUs. Confirm the actual configuration, availability and any application-specific requirements with your order.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;padding-top:24px;line-height:1.15;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eMT9930L buying questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs MT9930L transmitted-only?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. It includes transmitted and vertical incident LED Köhler illumination. Use transmitted light with suitable transparent preparations and incident light with appropriately prepared opaque surfaces and compatible objectives.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhich magnifications are supplied?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe supplied 4×, 10× and 40× objectives paired with 10× eyepieces give 40×, 100× and 400× visual magnification. Optional MA937 adds 200×; optional MA939 gives 600×. These are separate objective settings.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eAre compensating plates included?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eYes. The MA988 slider includes first-order red and quarter-wave plates and a clear position. The separately named MA904\/10 Sénarmont assembly has conflicting manufacturer inclusion information; confirm the current packing list rather than assuming it is included or excluded.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhat can the Bertrand lens do?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIt supports transmitted conoscopic observation of interference figures from suitable transparent crystalline grains. Proper centering, convergent illumination, suitable grain orientation and operator interpretation matter; a complete figure is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs a camera included?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. The trinocular head has a camera path, but the bare microscope is not a camera bundle. Confirm camera model, sensor, mount and field of view before selecting an adapter. The documented MA151\/35\/20 configuration is not a universal fit.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWill the standard microscope support point counting?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe standard stage rotates and includes clips. Structured point counting may use the separately selected MA945 attachment and an appropriate analytical protocol. The attachment does not itself certify a method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eCan it inspect opaque ore or metal?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe included incident LED illuminator supports reflected-light work on suitable polished, flat opaque surfaces. Confirm the objective and specimen-cover requirements for the specimen; do not assume the standard transmitted 40× is a dedicated polished-surface objective.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs this a certified asbestos or clinical diagnostic system?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo such certification or clinical clearance has been established here. Method-specific work may require additional optics, sample preparation, calibration, trained personnel and applicable laboratory authorization.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eDoes the shared manual cover LED service?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe MT9000 series manual supports optical and mechanical operating guidance but includes legacy halogen instructions. Do not apply its halogen relamping or electrical specifications to this LED model without current manufacturer guidance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49496537334058,"sku":"MT9930L 40X","price":9995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT9930L.webp?v=1730072325"}],"url":"https:\/\/bluetigerscientific.com\/collections\/meiji-techno-polarizing-microscopes.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}