{"title":"Meiji Techno Inverted Microscopes","description":"\u003cp\u003eBrowse inverted microscopes from Meiji Techno. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"meiji-techno-tc-5400l-trinocular-contrast-biological-microscope","title":"Meiji Techno TC-5400L LED Trinocular Inverted Phase-Contrast Microscope","description":"\u003cdiv id=\"bts-meiji-tc5400-guide\" style=\"font-family:'Open Sans',Arial,sans-serif;font-weight:300;color:#26332C;max-width:1400px;margin:0 auto;box-sizing:border-box;padding:20px;\"\u003e\n\u003csection style=\"padding:26px;box-sizing:border-box;background:#13314E;border-radius:12px;margin-bottom:24px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.8rem;font-weight:600;letter-spacing:.12em;color:#B7D0BF;\"\u003eMEIJI TECHNO · INVERTED PHASE CONTRAST\u003c\/p\u003e\n\u003ch2 style=\"font-size:2rem;line-height:1.2;font-weight:600;color:#fff;margin:14px 0;\"\u003eSee living cells.\u003cbr\u003eKeep your culture in its vessel.\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#fff;\"\u003eThe TC-5400L combines transmitted LED illumination, 10× and 20× phase objectives and a trinocular head for routine observation of transparent specimens. Start with the supplied optical system, then choose positioning and imaging accessories around your workflow.\u003c\/p\u003e\n\u003cp style=\"background:#fff;padding:12px;color:#13314E;border-radius:6px;font-weight:600;line-height:1.6;\"\u003e100× and 200× visual magnification included. Mechanical stage, vessel holders, camera and camera adapter are separate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cdiv style=\"padding:14px;background:#fff;border-radius:8px;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/TC-5400LUS1..webp?v=1728495544\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/TC-5400LUS1..webp?v=1728495544\" alt=\"TC-5400L manufacturer photograph with standard plain stage.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:440px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eTC-5400L manufacturer photograph with standard plain stage. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e100× \/ 200× supplied\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTwo MA817 10× eyepieces plus MA826 10× and MA827 20× phase objectives. The five-position nosepiece is not a five-objective package.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e73 mm condenser clearance\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eWorking distance of the supplied MA853 condenser. Objective working distances are different: 7.6 mm at 10× and 7.0 mm at 20×.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eTrinocular + front camera port\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTwo distinct imaging connection paths. Neither includes a camera or adapter; select one matched path rather than buying both by default.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eA usable phase microscope—not an accessory guessing game\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eIncluded optical system\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTC-5400L stand and MA816\/10 trinocular head; two MA817 10×\/FN22 eyepieces; MA826 10× and MA827 20× phase objectives; MA853 condenser; MA855 phase slider; MA458\/05 centering telescope; MA861 green phase filter; plain stage with MA878 glass insert.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eOptional workflow upgrades\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMA380\/05 mechanical stage and a matching vessel holder; MA825 4× phase objective; camera and appropriate adapter. The standard plain stage is already supplied. No fluorescence module, heater, incubator or environmental control is included.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose the microscope above for the standard configuration. Use the component grids for individual extras; photographs and application illustrations do not change what is supplied.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eWhy inverted geometry matters for culture work\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/TC-5400LUS3.webp?v=1728495544\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/TC-5400LUS3.webp?v=1728495544\" alt=\"TC-5400L side view: illumination above the specimen and objectives below the stage.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:460px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eTC-5400L side view: illumination above the specimen and objectives below the stage. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eObserve through the vessel bottom.\u003c\/strong\u003e The objectives sit below the stage while transmitted illumination comes from above. That arrangement lets you examine suitable cells and specimens in dishes or culture vessels rather than transferring every sample onto a conventional slide.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe long-working-distance optics help accommodate culture work, but vessel fit is not just a diameter question. Bottom thickness and optical quality, vessel height, stage support and access to the region of interest all matter.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eDo not use 73 mm as a universal vessel-height limit.\u003c\/strong\u003e It is a condenser specification—not a guarantee that every flask or multi-well plate fits or images well.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose your TC-5400L setup by the work you do\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose by what happens at your bench—not by magnification alone.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:18px;align-items:stretch;\"\u003e\n\u003carticle data-meiji-application=\"culture\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-tc5400-culture.webp?v=1793901331\" alt=\"Application illustration: Routine culture checks, not an image captured through the TC-5400L.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eAPPLICATION ILLUSTRATION\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eRoutine culture checks\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eObserve morphology and growth changes.\u003c\/strong\u003e Inspect transparent living cells in suitable culture vessels without routine fixation or staining. The supplied 100×\/200× visual settings are the starting point.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003ePlan around the vessel: verify its footprint, bottom optics and access before selecting a holder. This is not an incubator or a validated viability\/sterility assay.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle data-meiji-application=\"vessels\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-tc5400-vessels.webp?v=1793901331\" alt=\"Application illustration: Controlled specimen positioning, not an image captured through the TC-5400L.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eAPPLICATION ILLUSTRATION\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eControlled specimen positioning\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eChoose the stage around the sample.\u003c\/strong\u003e Add MA380\/05 when repeatable X–Y positioning is useful, then choose a holder for the actual dish, slide, counting chamber or Terasaki plate.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003eThe holder does not replace the mechanical stage. A nominal dish size alone does not establish optical compatibility.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle data-meiji-application=\"imaging\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-tc5400-imaging.webp?v=1793901332\" alt=\"Application illustration: Capture and compare observations, not an image captured through the TC-5400L.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eAPPLICATION ILLUSTRATION\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eCapture and compare observations\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003ePlan the camera connection first.\u003c\/strong\u003e For a compatible C-mount camera on the front port, select MA877. A top-phototube installation uses a different adapter route and needs a camera-specific check.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003eCamera, software and adapter are not supplied. Image scale and field coverage depend on the selected camera and optical path.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:.85rem;line-height:1.6;color:#526358;margin:12px 0 0;\"\u003eOriginal generated application illustrations, not manufacturer photographs, actual microscope images or promises of vessel\/camera compatibility. Authentic instrument and accessory photographs are identified separately.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003ePhase contrast or brightfield? Use the mode that reveals the specimen\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003ePhase contrast · Transparent specimens\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSelect the matching phase annulus to turn optical phase differences into visible brightness differences. Useful for unstained living cells and thin transparent specimens. Check annulus centering with the supplied telescope; thick specimens, thick vessel bottoms and phase halos can limit the result.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eBrightfield · Absorbing or colored detail\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMove the phase slider to its empty brightfield position. This is useful when the specimen already creates visible contrast. Transparent unstained cells may remain difficult to distinguish; closing the aperture excessively trades away brightness and resolution.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe supplied MA855 is \u003cstrong\u003eone slider\u003c\/strong\u003e: a 4× annulus, a shared 10×\/20×\/40× annulus and a brightfield position. The 4× position is ready for an optional MA825 objective; it does not mean a 4× objective is already included.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eStart with one of three buying paths\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e1 · Standard observation\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose TC-5400L alone when the supplied plain stage suits your vessel and positioning needs. Eyepieces, phase objectives, condenser, slider and centering telescope are already part of this configuration.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e2 · Add controlled positioning\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose TC-5400L + MA380\/05 + a holder matched to your vessel. For example, the 35 mm dish route uses MA384. Do not order every holder as a required set.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e3 · Add documentation\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose the microscope and the imaging path your camera requires. MA877 is the front-port C-mount attachment; a suitable camera is separate. A top-port adapter is not interchangeable by assumption.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThese are component shopping lists, not new bundled SKUs or a claim that optional parts are included in the microscope price.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003ePositioning and vessel holders · Select the stage, then the holder\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMA380\/05 adds 112 × 72 mm X–Y travel with drop-down coaxial controls. A suitable holder must be selected separately. The MA878 glass insert supplied with the plain stage does not fit MA380\/05.\u003c\/p\u003e\n\u003cdiv data-bts-accessory-slot=\"tc5400-support\"\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNeed a different vessel? Ask us to check it before ordering. Meiji also lists other holder formats; the options here are a focused selection, not a universal vessel-compatibility chart.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 22px;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;background:#F1F7F3;border-radius:10px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eThree fit checks worth making before checkout\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eMechanical fit\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTell us the vessel manufacturer\/model, outside footprint and height. A 56 × 87 mm Terasaki holder is not a general-purpose holder for full-size SBS plates.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eOptical fit\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConfirm bottom thickness and optical quality against the objective and specimen. A physically supported dish can still produce poor phase contrast if its bottom is unsuitable.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eWorkflow fit\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eDecide whether hand positioning is sufficient, controlled X–Y motion is needed, and whether the work requires imaging or environmental control beyond the supplied microscope.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose the field you need—not just a bigger number\u003c\/h2\u003e\n\u003cdiv class=\"product-specs-container\" style=\"width:100%;max-width:100%;box-sizing:border-box;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;border:1px solid #e0e0e0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eObjective\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eVisual magnification with supplied 10× eyepieces\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eNumerical aperture\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eObjective working distance\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA826 · included\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e10× phase \/ 100× total\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.25\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e7.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA827 · included\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e20× phase \/ 200× total\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.40\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e7.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA825 · optional\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e4× phase \/ 40× total\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.13\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e17.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe optional MA825 provides a lower-power view for finding a region before switching to detail. Use the slider’s 4× annulus with that objective. The supplied MA853 condenser has NA 0.30 and 73 mm working distance; those are not the objective values in this table.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eA 40× phase objective is another possible expansion, but it reduces objective working distance to 2.8 mm. Meiji recommends the MA854 NA 0.55 condenser for improved 40× phase observation; its working distance is 20.5 mm. Request a complete vessel\/optics check rather than treating this as a no-compromise upgrade.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eLow-power optics and front-port camera connection\u003c\/h2\u003e\n\u003cdiv data-bts-accessory-slot=\"tc5400-optics\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eTwo camera paths. One matched imaging plan.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eFront port:\u003c\/strong\u003e MA877 connects a compatible C-mount camera to the TC-5000 front port. It has no internal lens; the documented 0.66× factor belongs to the front-port optical system. It is not a 0.66× lens for the top phototube.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eTrinocular phototube:\u003c\/strong\u003e the MA816\/10 head offers a selectable split of 100% to the eyetubes, or 80% to the photo path and 20% to the eyetubes. This route requires its own matched adapter and camera.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eBefore selecting a camera, confirm mount, sensor size, required field coverage, computer\/connection requirements and whether calibrated measurements are needed. Neither port makes a camera, software or measurement calibration part of this order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-tc5400-ma877.jpg?v=1793901331\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-tc5400-ma877.jpg?v=1793901331\" alt=\"MA877 manufacturer photograph: optional front-port C-mount attachment, camera not included.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA877 manufacturer photograph: optional front-port C-mount attachment, camera not included. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eSet up the phase system deliberately\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e1 · Start with low power\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSecure the vessel and begin with a supplied low-power objective. Watch objective-to-stage clearance when changing objectives; long working distance does not prevent collisions.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e2 · Match and center the annulus\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse the shared annulus for the supplied 10×\/20× phase objectives. Check the phase ring alignment with the supplied centering telescope and follow the manual’s alignment procedure.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e3 · Adjust for the specimen\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFocus on the specimen plane, adjust illumination and use the supplied green phase filter as appropriate. If contrast is poor, check annulus, centering, bottom optics and specimen thickness before assuming more magnification will help.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose a different instrument when the job changes\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTC-5400L is a transmitted brightfield\/phase-contrast culture-observation microscope. It is \u003cstrong\u003enot a supplied fluorescence, heated live-cell imaging or micromanipulation workstation\u003c\/strong\u003e. Do not choose it on the assumption that GFP imaging, CO₂ control, time-lapse automation or clinical validation is included.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eFor low-power dissection, specimen sorting or electronics surface inspection, compare the \u003ca href=\"\/products\/meiji-techno-emz-5-binocular-zoom-stereo-body\" style=\"color:#245B45;\"\u003eMeiji EMZ-5 stereo microscope setup guide\u003c\/a\u003e. It serves a different task and is not an accessory for TC-5400L.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;padding-top:24px;line-height:1.15;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eTC-5400L buying questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs this TC-5400L binocular or trinocular?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThis is the trinocular TC-5400L configuration with the manufacturer-listed MA816\/10 head. It has two viewing eyepieces plus a top phototube. Meiji’s dealer model matrix distinguishes it from the binocular TC-5300L, even though one manufacturer webpage title incorrectly says binocular.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhat magnifications are included?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e100× and 200× visual magnification: two 10× eyepieces with the supplied 10× and 20× phase objectives. The nosepiece has five positions, but only those two objectives are included. MA825 4× is optional and gives 40× total with the same eyepieces.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eAre the phase slider and centering telescope supplied?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eYes. The standard phase configuration lists MA855 slider, MA458\/05 centering telescope and MA861 green phase filter. There is one slider with a 4× position, a shared 10×\/20×\/40× position and a brightfield opening—not three separately supplied sliders.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eDo I need to add a mechanical stage?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNot for every application: the microscope includes a plain stage with glass insert. If controlled X–Y movement is needed, add MA380\/05 and a suitable holder. The included MA878 insert fits the plain stage, not the optional MA380\/05.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWill my dish, flask or multi-well plate fit?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eWe need the exact vessel model and dimensions to check. Footprint, height, bottom thickness\/optical quality, stage support and access all matter. The condenser’s 73 mm working distance is not a universal maximum vessel height, and a named dish holder does not guarantee optical performance through every dish bottom.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eDoes the trinocular head mean a camera is included?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. Camera and adapter are separate. MA877 is the front-port C-mount attachment, with no internal lens; the documented 0.66× is the TC front-port system factor. A top-phototube setup needs its own camera\/adapter check.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eCan it perform fluorescence or incubated live-cell imaging as supplied?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo fluorescence module, incubator, heater or CO₂ control is included in this configuration. Phase contrast can help observe suitable living cells without fixation or staining, but it is not a guarantee of environmental control, viability measurement or sterility testing.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs the manual specific to the LED version?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe official TC5000 manual covers series optics, phase alignment and mechanical operation, but contains legacy halogen lamp instructions. This listing is for the LED TC-5400L; do not use legacy halogen relamping steps for LED service. Ask us to coordinate current LED service guidance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eCan I request one quote for the microscope and selected accessories?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eYes. Add the microscope and chosen components to the Quote Cart and check exact quantities before submitting. Each is a separate line; a stage may also need a selected holder, and a camera adapter does not include a camera. Availability, shipping and the requested configuration are confirmed with the quote.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49388962349354,"sku":"TC-5400L","price":7530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/TC-5400LUS1..webp?v=1728495544"},{"product_id":"meiji-techno-tc-5100-binocular-brightfield-biological-microscope","title":"Meiji Techno TC-5100 Binocular Brightfield Biological Microscope","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeidentopf type binocular head inclined at 30° or trinocular at 45°\u003c\/li\u003e\n\u003cli\u003eEquipped with 6V, 30W Halogen lamp illuminator\u003c\/li\u003e\n\u003cli\u003eNumerical Aperture 0.30 condenser\u003c\/li\u003e\n\u003cli\u003e180mm(X) x 245mm(Y) stage with replaceable glass insert with 45mm opening\u003c\/li\u003e\n\u003cli\u003eExchangeable observation tubes\u003c\/li\u003e\n\u003cli\u003eIntegrated Automatic Voltage Sensing Power Supply with localized power cord\u003c\/li\u003e\n\u003cli\u003eCompact wedge-shaped cast aluminum alloy frame for exceptional stability and a small footprint\u003c\/li\u003e\n\u003cli\u003eChemical resistant baked enamel finish\u003c\/li\u003e\n\u003cli\u003eFlexible and modular design for system expansion\u003c\/li\u003e\n\u003cli\u003eTransparent stage plate for easy objective identification\u003c\/li\u003e\n\u003cli\u003eLow profile coaxial and fine focus controls with tension adjustment\u003c\/li\u003e\n\u003cli\u003ePrecentered LED bulb\u003c\/li\u003e\n\u003cli\u003eFront mounted CCD, analog, or SLR cameras\u003c\/li\u003e\n\u003cli\u003eOptional mechanical stage with specimen holders\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TC Series microscopes streamline the examination of tissue cultures, microbes, and other live specimens in petri dishes and culture bottles, offering an excellent performance-to-cost ratio compared to other high-quality manufacturers. Available in brightfield, phase contrast, and epi-fluorescence models, the TC5000 Series stands out with its integrated front-mounted camera port, compatible with 35mm, CCD, CMOS, and other cameras, standard on binocular models.\u003c\/p\u003e\n\u003cp\u003eEach model is equipped with 10x Super Widefield eyepieces, a quintuple smooth-operating ball bearing objective changer, and a range of newly designed Planachromat Infinity-corrected objectives for brightfield, phase contrast, and fluorescence microscopy. The brightfield and phase models feature a condenser with an N.A. of 0.30 and an extra-long working distance of 73mm. A powerful 6v 30w halogen illumination system with pre-centered bulb provides enhanced image quality and brightness. An optional attachable mechanical stage measuring 112mm (X) x 72mm (Y) is available, along with various other objectives, eyepieces, and accessories. This microscope is ideal for critical viewing applications and comes with a manufacturer’s lifetime warranty.\u003c\/p\u003e\n\u003cp\u003eA centering telescope is included.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49389562560810,"sku":"TC-5100","price":6440.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/5100-fotor-20241009141120.webp?v=1728508450"}],"url":"https:\/\/bluetigerscientific.com\/collections\/meiji-techno-inverted-microscopes.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}