{"title":"Meiji Techno Biological Microscopes","description":"\u003cp\u003eBrowse biological microscopes from Meiji Techno. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"meiji-techno-mt5210l-led-binocular-phase-contrast-microscope","title":"Meiji Techno MT5210L LED Binocular Brightfield\/Phase Contrast Microscope","description":"\u003cdiv id=\"bts-meiji-mt5210-guide\" style=\"font-family:'Open Sans',Arial,sans-serif;font-weight:300;color:#26332C;max-width:1400px;margin:0 auto;box-sizing:border-box;padding:20px;\"\u003e\n\u003csection style=\"padding:26px;box-sizing:border-box;background:#13314E;border-radius:12px;margin-bottom:24px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.8rem;font-weight:600;letter-spacing:.12em;color:#B7D0BF;\"\u003eMEIJI TECHNO · BRIGHTFIELD \u0026amp; PHASE CONTRAST\u003c\/p\u003e\n\u003ch2 style=\"font-size:2rem;line-height:1.2;font-weight:600;color:#fff;margin:14px 0;\"\u003eChoose the contrast.\u003cbr\u003eFollow the specimen.\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#fff;\"\u003eExplore thin wet mounts and prepared stained slides with the standard MT5210L. Infinity-corrected U.Plan phase optics, adjustable LED Köhler illumination and a binocular viewing head bring a deliberate, hands-on workflow to research and advanced teaching.\u003c\/p\u003e\n\u003cp style=\"background:#fff;padding:12px;color:#13314E;border-radius:6px;font-weight:600;line-height:1.6;\"\u003e100×, 200×, 400× and 1000× visual settings supplied. The 100× objective requires oil immersion; the binocular head has no dedicated camera port.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cdiv style=\"padding:14px;background:#fff;border-radius:8px;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT5210L.webp?v=1730051649\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT5210L.webp?v=1730051649\" alt=\"Meiji Techno MT5210L: authentic product photograph from the existing gallery.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:440px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMeiji Techno MT5210L: authentic product photograph from the existing gallery. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eTwo core contrast methods\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTransmitted brightfield for suitable stained or naturally pigmented slides; phase contrast for thin, transparent mounted preparations.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eFour supplied phase objectives\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e10×, 20×, 40× and 100× oil objectives pair with the supplied 10× eyepieces. Separate objective settings—not a zoom.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eFN22 binocular viewing\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003ePaired MA817 10× high-eyepoint eyepieces and the MA815 binocular head are supplied. No camera or trinocular port is included.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eWhat is included—and what is a separate choice?\u003c\/h2\u003e\n\u003cdiv class=\"product-specs-container\" style=\"width:100%;max-width:100%;box-sizing:border-box;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:620px;border-collapse:collapse;font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;border:1px solid #e0e0e0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eSupplied area\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eStandard MT5210L configuration\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eImportant distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eViewing\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eMA815 fixed 30° binocular head; two MA817 10× FN22 eyepieces and two MA906 eyeshields.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eSupplied; no dedicated camera port.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eObjectives\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eMA839 10×, MA840 20×, MA841 40×, MA842 100× oil U.Plan phase objectives.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eFour supplied objectives on a five-position nosepiece; no fifth objective promised.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eContrast and alignment\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eMA913 centerable Zernike condenser, MA458\/05 centering telescope, MA861\/05 green interference filter.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eBrightfield position, matched phase annuli and darkfield stop for 40× only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eSlide handling and focus\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eMA918R ceramic-coated mechanical stage with right-hand drop-down coaxial X–Y controls; MA598 slide holder.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eCoarse\/fine focus, focus-tension adjustment and adjustable stage-height safety stop.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eLighting and supporting items\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eBuilt-in variable-intensity white LED Köhler illumination; automatic voltage-sensing supply and regional mains cord; dust cover, spare fuse, manual and warranty card.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eConfirm destination cord and current packing list. Built-in LED is not a loose spare lamp; oil bottle is not confirmed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe standard instrument supports visual observation without the optional upgrades below. Slides, preparations and measurement accessories are separate. Do not assume an immersion-oil bottle is supplied; arrange the appropriate oil before using the 100× oil objective.\u003c\/p\u003e\u003c\/section\u003e\u003csection data-bts-gap-section=\"true\" style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eBefore you begin · Complete the bench, not just the microscope\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe standard instrument already supplies the observation hardware. Prepare the specimen and supplies for your actual method; do not treat every item below as a mandatory accessory purchase.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eSlides and cover glass\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse glass slides suited to the MA598 holder and your preparation. The supplied MA842 100× oil objective is specified for 0.17 mm cover-glass correction; check the selected cover-glass thickness and tolerance rather than assuming every chamber slide or cover is interchangeable.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eOil only when the method needs it\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe supplied 10×, 20× and 40× objectives are dry. Appropriate immersion oil is needed for the 100× oil objective. The US packing list does not confirm a starter bottle; check your supplied contents before buying extra, or choose oil for replenishment.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eOptics care\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eHave a soft brush or bellows brush and appropriate lint-free materials available. Follow the MT5000 manual for cleaning and fluids; do not assume ordinary eyeglass wipes or general surface cleaners are appropriate. The dust cover is already supplied.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIf your preparation method specifically calls for positively charged slides, our \u003ca href=\"\/products\/mtc-bio-positively-charged-microscope-slides\" style=\"color:#245B45;\"\u003eMTC Bio positively charged slides\u003c\/a\u003e are an existing catalog option: 25 × 75 mm, 1.1 mm thick, 72 per pack. Confirm holder fit, corner style and preparation protocol; these are not a blanket recommendation for every wet mount. Cover glass and optics-care materials should be selected separately to their verified specifications.\u003c\/p\u003e\u003c\/section\u003e\u003csection data-bts-gap-section=\"true\" style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eImmersion oil · Check starter supply, then replenish\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eMA700, 7.4 cc (7.4 mL).\u003c\/strong\u003e Meiji lists this oil for oil-immersion microscope objectives. Choose it when oil is needed for the supplied MA842 100× oil objective, or as replenishment. It is not for the supplied dry objectives, and it is not the separately numbered MA700\/10.\u003c\/p\u003e\n\u003cdiv data-bts-accessory-slot=\"mt5210-essentials\"\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe manufacturer photograph shows front and back views, not a two-pack. Confirm current packaging and safety information with your order; a factory-supplied starter bottle is not assumed either present or absent.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eThree practical bench workflows\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMatch the method to a thin, mounted specimen—not simply to a higher magnification.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:18px;align-items:stretch;\"\u003e\n\u003carticle data-meiji-application=\"wetmount\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-wetmount.webp?v=1793917722\" alt=\"Generated still-life illustration: Thin, unstained wet mounts. Not a micrograph.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eGENERATED STILL LIFE · NOT A MICROGRAPH\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eThin, unstained wet mounts\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eStart with transparent preparations.\u003c\/strong\u003e Use phase contrast to explore yeast suspensions or suitably thin pond-water preparations on glass slides. Begin with the 10× objective and Ph1 to locate a useful area.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003eThin, evenly spread preparations matter. Halos and shade-off can change the appearance of edges; these examples are not identification assays.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle data-meiji-application=\"stained\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-stained.webp?v=1793917722\" alt=\"Generated still-life illustration: Prepared stained slides. Not a micrograph.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eGENERATED STILL LIFE · NOT A MICROGRAPH\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003ePrepared stained slides\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eLet absorption supply the contrast.\u003c\/strong\u003e Choose the brightfield condenser position for suitable prepared plant or tissue sections. Compare visible structures at a useful objective setting rather than starting at maximum magnification.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003ePreparation thickness, staining and illumination affect what is visible. This is not a diagnostic workflow or a through-flask inverted microscope.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\u003carticle data-meiji-application=\"measurement\" style=\"flex:1 1 260px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;border-radius:10px;overflow:hidden;background:#F1F7F3;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-measurement.webp?v=1793917723\" alt=\"Generated still-life illustration: Calibrated visual comparisons. Not a micrograph.\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;\"\u003e\u003cdiv style=\"padding:20px;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.75rem;letter-spacing:.07em;font-weight:600;color:#526358;margin:0 0 10px;\"\u003eGENERATED STILL LIFE · NOT A MICROGRAPH\u003c\/p\u003e\n\u003ch3 style=\"font-size:1.15rem;line-height:1.35;color:#245B45;font-weight:600;margin:0 0 10px;\"\u003eCalibrated visual comparisons\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eAdd a scale only when needed.\u003c\/strong\u003e For a size-measurement workflow, the optional MA506 reticle adds an eyepiece scale and MA285 provides a known stage scale for calibration. Record the conversion for each objective.\u003c\/p\u003e\n\u003cp style=\"font-size:.9rem;line-height:1.65;color:#526358;margin:0;\"\u003eThe illustration shows a preparation workflow, not measured results. Neither a measurement reticle nor a calibration slide is supplied with the microscope.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eOriginal generated still-life illustrations, not manufacturer product photographs or images captured through the MT5210L. Specimens and preparation materials shown are not supplied.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eMatch the objective to the phase annulus\u003c\/h2\u003e\n\u003cdiv class=\"product-specs-container\" style=\"width:100%;max-width:100%;box-sizing:border-box;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:760px;border-collapse:collapse;font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;border:1px solid #e0e0e0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eSupplied part\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eObjective\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eNA\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eWorking distance\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eWith 10× eyepieces\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003ePhase setting \/ use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA839\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e10× phase\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.25\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e10.7 mm\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e100×\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003ePh1 · dry objective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA840\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e20× phase\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.40\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e7.29 mm\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e200×\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003ePh1 · dry objective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA841\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e40× phase\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.65\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e400×\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003ePh2 · dry objective\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eMA842\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e100× phase oil\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e1.25\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e0.23 mm\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003e1000×\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003ePh3 · oil immersion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eBoth 10× and 20× use Ph1.\u003c\/strong\u003e The 40× uses Ph2; the 100× oil objective uses Ph3. Center the corresponding annulus rather than assuming alignment is automatic. FN22 refers to the supplied eyepieces; objective field-number specifications do not change that eyepiece field.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose illumination and contrast deliberately\u003c\/h2\u003e\n\u003cdiv class=\"product-specs-container\" style=\"width:100%;max-width:100%;box-sizing:border-box;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:620px;border-collapse:collapse;font-family:'Open Sans',Arial,sans-serif;font-size:1rem;font-weight:300;border:1px solid #e0e0e0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eMethod\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eSupplied setup\u003c\/th\u003e\n\u003cth style=\"background:#f5f5f5;text-align:left;padding:12px;border:1px solid #e0e0e0;font-weight:700;\"\u003eScope \/ limit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eBrightfield\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eMA913 brightfield position; variable-intensity LED Köhler illumination.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eSuitable stained or naturally pigmented thin mounted specimens.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f9f9f9;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003ePhase contrast\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eMatch Ph1 \/ Ph2 \/ Ph3 as above; use the supplied telescope and green interference filter during setup as directed.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eThin transparent preparations. Align the annulus to the objective phase ring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:600;\"\u003eLimited darkfield\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eMA913 darkfield stop specified for the 40× objective.\u003c\/td\u003e\n\u003ctd style=\"padding:12px;vertical-align:top;overflow-wrap:anywhere;border:1px solid #e0e0e0;font-weight:300;\"\u003eNot all-objective darkfield. The supplied 100× phase oil objective does not establish 1000× oil darkfield capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThis is an upright transmitted-light microscope. LED illumination does not imply fluorescence, and the supplied condenser does not establish a dedicated high-NA oil-darkfield system.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 22px;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;background:#F1F7F3;border-radius:10px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eA setup sequence that earns useful contrast\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e1 · Start dry and low\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSecure a thin mounted slide. Set interpupillary distance and diopter for comfortable binocular viewing. Locate and focus with the 10× dry objective, using the manual’s illumination and stage-stop guidance.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e2 · Establish illumination\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAdjust the LED intensity, field diaphragm and condenser according to the Köhler procedure. For phase work, select the matching phase position and use the green filter as directed; a phase annulus is not an aperture-brightness control.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003e3 · Check the rings\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTemporarily replace one eyepiece with the supplied MA458\/05 telescope. Focus the telescope to see the rings sharply and center the condenser annulus on the objective phase ring. Repeat for the matched objectives, then restore the eyepiece.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIf contrast looks wrong, check annulus selection and centering, specimen thickness and cleanliness before choosing more magnification. Consult the manual for the complete operating sequence.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003e100× oil: plan the last step, not the first\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse the MA842 100× oil objective only with the appropriate immersion oil and the preparation\/immersion procedure specified by Meiji. Start with a dry lower-power objective, find the area of interest, then proceed carefully: the 100× oil working distance is short.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eKeep dry objectives dry\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eDo not sweep the 10×, 20× or 40× dry objective through an oil drop. Follow the manufacturer’s condenser-immersion instructions where required for the high-NA setup; do not oil components indiscriminately.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eFocus and clean carefully\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eCheck slide clearance and the stage stop; do not drive the objective into the slide. After use, remove immersion oil promptly with lens tissue and manufacturer-approved cleaning materials—not abrasive wipes.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eKnow the mode limit\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e1000× is the total visual magnification with the 100× oil objective. It is not a promise of additional useful detail for every specimen and is not a supplied 1000× oil-darkfield mode.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eOptional comfort: change the viewing angle, not the camera path\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-MA957.webp?v=1793917721\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-MA957.webp?v=1793917721\" alt=\"MA957 ergonomic binocular replacement head: genuine manufacturer photograph cropped from the MT5000 brochure, page 5.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:380px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA957 ergonomic binocular replacement head: genuine manufacturer photograph cropped from the MT5000 brochure, page 5. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eMA957 · ergonomic tilting binocular head.\u003c\/strong\u003e Consider it only if the supplied fixed 30° head does not suit your seated position or shared-user setup. The optional head offers a 10–50° viewing angle and 30 mm eyetubes for the supplied eyepieces.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIt replaces the supplied head; it is not an extra head needed for basic use and does not add a dedicated camera port. Arrange manufacturer\/dealer-approved installation and confirm the exact unsuffixed MA957—not a different eyetube-size variant.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-bts-accessory-slot=\"mt5210-support\"\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eOptional measurement: a reticle plus a calibration reference\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChoose these only for a visual measurement workflow. The supplied MA817 eyepiece already accepts the 25 mm reticle; no replacement focusing eyepiece is required merely to fit it.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:24px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-ma506.jpg?v=1793917720\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-ma506.jpg?v=1793917720\" alt=\"MA506 manufacturer scale diagram—not a product photograph. Reticle markings: 10 mm divided into 100 units.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:360px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA506 manufacturer scale diagram—not a product photograph. Reticle markings: 10 mm divided into 100 units. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eMA506 · eyepiece measurement reticle.\u003c\/strong\u003e A 25 mm reticle for one supplied MA817 eyepiece. Its engraved divisions are not automatically specimen dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;box-sizing:border-box;\"\u003e\n\u003cfigure style=\"margin:0;min-width:0;box-sizing:border-box;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-ma285.jpg?v=1793917721\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:block;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-ma285.jpg?v=1793917721\" alt=\"MA285 manufacturer slide\/scale diagram—not a product photograph. Stage scale: 1 mm divided into 100 units.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:360px;height:auto;object-fit:contain;margin:0 auto;border-radius:8px;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA285 manufacturer slide\/scale diagram—not a product photograph. Stage scale: 1 mm divided into 100 units. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eMA285 · transmitted-light calibration slide.\u003c\/strong\u003e The 1 mm scale has 100 divisions: 0.01 mm (10 µm) per division on the slide. It supplies a known reference for calibrating the reticle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-bts-accessory-slot=\"mt5210-optics\"\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAlign the reticle and stage scales, compare a useful span, and calculate specimen length per reticle division for each objective. Recheck after changing the optical configuration. No calibration certificate, traceability class or measurement accuracy is promised here.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eChoose only what your bench needs\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;\"\u003e\n\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eObserve at the eyepieces\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSelect the standard microscope for thin mounted research\/teaching preparations. Supplied phase optics, telescope and filter cover the core setup; optional accessories are not mandatory.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eImprove viewing posture\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConsider MA957 only when adjustable inclination solves a real comfort problem. Retain a binocular workflow; this is not a camera conversion.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"flex:1 1 230px;min-width:0;box-sizing:border-box;border:1px solid #B7D0BF;padding:20px;border-radius:8px;background:#F1F7F3;\"\u003e\u003ch3 style=\"font-size:1.1rem;line-height:1.35;font-weight:600;color:#245B45;margin:0 0 10px;\"\u003eMeasure a visible feature\u003c\/h3\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eConsider MA506 with MA285 if calibrated eyepiece measurements are part of your method. A scale without objective-specific calibration is not a measurement system.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection data-bts-gap-section=\"true\" style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eNeed a wider overview? Quote the complete low-power path\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eMA830 2.5× brightfield objective + MA976 low-power condenser\u003c\/strong\u003e is the manufacturer-listed scanning combination. With the supplied 10× eyepieces, it provides 25× total visual magnification. This is a two-component configuration to review—not a single-lens add-on or a bundled SKU.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:20px;align-items:stretch;\"\u003e\n\u003cfigure style=\"flex:1 1 280px;min-width:0;box-sizing:border-box;margin:0;padding:14px;background:#fff;border:1px solid #B7D0BF;border-radius:8px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-lowpower-ma830.jpg?v=1793921121\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-lowpower-ma830.jpg?v=1793921121\" alt=\"MA830 manufacturer photograph: two views of one optional 2.5× objective.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;margin:0 auto;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA830 manufacturer photograph: two views of one optional 2.5× objective. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cfigure style=\"flex:1 1 280px;min-width:0;box-sizing:border-box;margin:0;padding:14px;background:#fff;border:1px solid #B7D0BF;border-radius:8px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-lowpower-ma976.jpg?v=1793921121\" data-meiji-zoom=\"true\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-meiji-mt5210-lowpower-ma976.jpg?v=1793921121\" alt=\"MA976 manufacturer photograph: optional swing-out condenser shown in two views.\" loading=\"lazy\" style=\"display:block;width:100%;max-width:420px;height:auto;object-fit:contain;margin:0 auto;\"\u003e\u003c\/a\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eMA976 manufacturer photograph: optional swing-out condenser shown in two views. · Select image to enlarge.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe MA976 replaces the supplied MA913 for this workflow. Do not assume the phase condenser alone provides a fully illuminated 2.5× field, or that phase contrast remains available after the swap. Reinstall MA913 and recheck alignment to return to phase work.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eRequest a configuration quote specifying \u003cstrong\u003eMT5210L, MA830 and MA976\u003c\/strong\u003e. \u003ca href=\"mailto:info@bluetigerscientific.com?subject=MT5210L%20low-power%20configuration%20quote\" style=\"display:inline-block;margin-top:10px;padding:10px 16px;border-radius:6px;background:#235c86;color:#fff;text-decoration:none;font-weight:600;\"\u003eRequest low-power configuration review\u003c\/a\u003e. Current condenser specifications, installation, field coverage and availability need confirmation before purchase. This option is therefore quote-first, not an orderable parts bundle. It is useful for finding regions on appropriately contrasting prepared slides—not automated whole-slide scanning.\u003c\/p\u003e\u003c\/section\u003e\u003csection data-bts-gap-section=\"true\" style=\"padding:26px 0;box-sizing:border-box;border-bottom:1px solid #B7D0BF;margin-bottom:24px;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eSpecialist darkfield · Check current support, not just an old parts list\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe standard MA913 already has the documented darkfield stop for 40×. That does not establish a supplied 1000× oil-darkfield system.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eOlder documentation lists MA914 with MA836 50× oil-with-iris or MA838 100× oil-with-iris for specialist darkfield. Meiji’s current standalone component pages identify those parts as \u003cstrong\u003ediscontinued\u003c\/strong\u003e. They are not offered here as purchasable upgrades, and the supplied MA842 phase oil objective is not a verified substitute for an iris-equipped darkfield objective.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eIf higher-power darkfield is essential, describe your specimen, required magnification and existing setup when requesting a technical\/availability review. Obtain a current manufacturer-supported alternative before ordering. No availability, diagnostic use or turnkey configuration is promised. \u003ca href=\"mailto:info@bluetigerscientific.com?subject=MT5210L%20darkfield%20alternatives%20review\" style=\"display:inline-block;margin-top:10px;padding:10px 16px;border-radius:6px;background:#235c86;color:#fff;text-decoration:none;font-weight:600;\"\u003eAsk about supported alternatives\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;padding-top:24px;line-height:1.15;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;line-height:1.3;color:#245B45;margin:0 0 16px;\"\u003eMT5210L buying questions\u003c\/h2\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhat magnifications come with the standard MT5210L?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe supplied 10× eyepieces and 10×, 20×, 40× and 100× oil phase objectives provide 100×, 200×, 400× and 1000× visual settings. These are discrete objective selections, not continuous zoom; no 4× or fifth objective is promised.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhich phase annulus should I use?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eUse Ph1 for both 10× and 20×, Ph2 for 40×, and Ph3 for 100× oil. Use the supplied centering telescope to check and center the annulus against the objective phase ring, following the manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eCan I view a stained slide without changing the objectives?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eYes, suitable thin stained preparations can be observed using the condenser’s brightfield position and the supplied phase objectives. A separate brightfield objective set is not listed as included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eDoes it include darkfield at 1000×?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. The supplied MA913 condenser has a darkfield stop specified for 40×. The 100× phase oil objective and supplied condenser are not a confirmed high-NA oil-darkfield system.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs a camera port included, or added by MA957?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. The standard MA815 is binocular with no dedicated trinocular camera port. MA957 is an optional ergonomic binocular replacement, not a camera attachment. No plug-and-play camera configuration is established here.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eAre phase contrast and high magnification always better?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. Choose contrast for the preparation and useful magnification for the feature. Phase can help with transparent thin specimens but can introduce halos and shade-off; thick or uneven preparations can obscure detail.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eDo I need oil for every objective?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. The supplied 10×, 20× and 40× objectives are dry. The MA842 100× objective requires appropriate immersion oil and careful setup. Keep dry objectives out of oil and clean the oil objective as Meiji directs; an oil bottle is not confirmed as supplied.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eIs MA506 enough to read specimen dimensions?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNot by itself. Install it in a compatible supplied MA817 eyepiece, then calibrate its divisions with MA285 or an appropriate known stage standard for every objective\/optical configuration. Reticle markings do not directly equal specimen dimensions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eMust I buy every item shown on this page?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eNo. MA957 is an optional comfort replacement; MA506 and MA285 support calibrated visual measurement. MA700 is for oil-immersion use or replenishment when needed, after checking any starter supply. The low-power path is a quote-first configuration, not a required purchase. The standard observation hardware is already supplied.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin-bottom:12px;background:#fff;\"\u003e\u003csummary style=\"padding:18px;font-size:1rem;line-height:1.3;font-weight:600;cursor:pointer;color:#13314E;\"\u003eWhy do the brochure and manual need caution?\u003c\/summary\u003e\u003cdiv style=\"padding:0 18px 18px;\"\u003e\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThey cover multiple MT5000 configurations. Some brochure summaries conflict with the exact-model supplied list, and the shared manual includes legacy halogen service instructions. Use the standard configuration stated here; confirm the current packing list and obtain current LED\/electrical service guidance rather than applying conflicting legacy data.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49438078304554,"sku":"MT5210L","price":4700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT5210L.webp?v=1730051649"},{"product_id":"meiji-techno-mt4200l-biological-compound-binocular-brightfield-40x-1000x-with-infinity-corrected-u-plan-4x-10x-40x-100x-oil","title":"Meiji Techno MT4200L - Biological Compound Binocular Brightfield (40x-1000x) with Infinity Corrected U. Plan (4x, 10x, 40x, 100x Oil)","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompact Space Saving Footprint design with ergonomics in mind\u003c\/li\u003e\n\u003cli\u003eInfinity Corrected Optical System (ICOS™) with all newly designed Planachromatic optics\u003c\/li\u003e\n\u003cli\u003eComfortable Siedentopf-type Binocular and Trinocular Viewing heads\u003c\/li\u003e\n\u003cli\u003eOptional Ergonomic tilting binocular head- Adjustable vertically from 10°to 50° degrees\u003c\/li\u003e\n\u003cli\u003eCeramic Coated Stage with Ergonomically Placed Low Position Drop down Control\u003c\/li\u003e\n\u003cli\u003eParfocalled Microscope Objectives\u003c\/li\u003e\n\u003cli\u003eTension adjustment control with Coaxial knobs\u003c\/li\u003e\n\u003cli\u003eLow Positioned Ergonomic Coaxial Focus Control\u003c\/li\u003e\n\u003cli\u003eLow Positioned Ergonomic Coaxial Focus Control\u003c\/li\u003e\n\u003cli\u003eSmooth Operating Ergonomic Quintuple Nosepiece\u003c\/li\u003e\n\u003cli\u003eBrightfield and Phase Contrast Observation modes available\u003c\/li\u003e\n\u003cli\u003eSuper Bright LED Koehler illumination, Lambertian design\u003c\/li\u003e\n\u003cli\u003eIntegrated 30-Watt Halogen Transmitted illumination System on selected Brightfield and Phase Contrast Models\u003c\/li\u003e\n\u003cli\u003eAbbe and Zernike Phase Contrast Condensers available\u003c\/li\u003e\n\u003cli\u003eIntegrated Automatic Voltage Sensing Power Supply with localized power cord\u003c\/li\u003e\n\u003cli\u003eRear Cord Wrap for easy storage\u003c\/li\u003e\n\u003cli\u003eWide Range of Filters and Accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MT4200L Series is Meiji Techno’s newly designed upright Binocular Biological Compound LED Microscope system. Equipped with newly upgraded Infinity Corrected U. Plan 4X,10X 40X and 100X oil objectives. Ergonomically designed, precisely manufactured in Japan and simple to use stage and coarse and fine controls. To meet the demands of researchers and clinical laboratory specialists.\u003c\/p\u003e\n\u003cp\u003eMeiji Techno has reviewed all aspects of microscope usability to develop the MT4200L microscope, which provides functionality with operational ease. Viewing high quality images, sample changing and photomicroscopy are all conducted with ergonomics in mind. High luminescent LED illumination reduces need for frequent bulb replacement, especially in the middle of midterms or a special research project.\u003c\/p\u003e\n\u003cp\u003eThe MT4200L is designed for Brightfield observation and rugged quality as you would expect from a microscope that is 100% MADE IN JAPAN. Various imaging techniques are available with different models in this series.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBrightfield:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light and contrast in the sample is caused by absorbance of some of the transmitted light in dense areas of the sample. Brightfield microscopy is the simplest of a range of techniques used for illumination of samples in light microscopes and its simplicity makes it a popular technique. The typical appearance of a brightfield microscopy image is a dark sample on a bright background.\u003c\/p\u003e\n\u003cp\u003eThe MT4000 Series is a newly designed upright biological compound microscope system. Ergonomically designed, precisely manufactured and simple to use stage and coarse and fine controls. To meet the demands of researchers and clinical laboratory specialists. The MT4000 Series was to develop to provide functionality and operational ease. Viewing high quality images, sample changing and photomicroscopy are all conducted with ergonomics in mind. High luminescent LED illumination reduces need for frequent bulb replacement but still provide rugged durability and long life span.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eVIEWING HEADS\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eModel MA815\/05 is the Siedentopf-type binocular head and Model MA816\/05 is the trinocular head for camera integration. Each head has the eyetubes inclined at 30 ° with the left eyetube having graduated diopter settings. The interpupillary distance is adjustable between 53mm - 75mm. An 80\/20 beamsplitter for the trinocular tube can be engaged for photo work.The optional MA957\/05, Ergonomic Binocular Viewing Head, has the inclination adjustable from 10 to 50 degrees to fit users of different heights. The Ergonomic Trinocular model comes with the MA958, photo\/video attachment with sliding 80\/20 beam-splitter (Included in MT4300ED).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEYEPIECES\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e10X Widefield High Eyepoint eyepieces F.N.20 are standard, and 15X and 20X eyepieces are available as an option. A Widefield High Eyepoint 10X focusable eyepiece that accepts 21mm reticules is also available.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOBJECTIVE CHANGER\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eQuintuple nosepiece provides effortless objective changes with smooth-operating, ball bearing mounted.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOBJECTIVES\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eMeiji Techno America offers an assortment of Planachromat Infinity Corrected (ICOS) objectives for Brightfield, Darkfield and Phase Contrast observation modes.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSTAGE\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCeramic coated standard right-handed or optional left-handed controls, flat top stage 171mm x 115mm and travels 78mm(X) x 52mm(Y). Ergonomically positioned coaxial drop down controls. Available with motorized focus and stage controls.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCONDENSER\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNew design centerable Abbe 1.25 N.A. Condenser with built-in iris diaphragm in dovetail mount.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eILLUMINATION\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003ePowerful white LED illumination provides enhanced image quality and brightness for the observation of specimens and photomicroscopy.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePHOTOMICROGRAPHY\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eMeiji Techno offers a broad range of digital video cameras which offers excellent sensitivity, high resolution and a wide dynamic range for the most demanding brightfield and darkfield microscopy applications including clinical pathology and cytology, life sciences and geology. Some models has included software, that can preview and capture still shots and live videos to a PC or Mac with USB port or HDMI connectivity.\u003c\/p\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49438088986922,"sku":"MT4200L","price":3850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/Meiji_Techno_MT4200L_LED_Binocular_Brightfield_Biological_Microscope_Right_Angel_View.jpg?v=1732637637"},{"product_id":"meiji-techno-mt5300ehv-hd-halogen-ergonomic-trinocular-biological-veterinary-brightfield-compound-microscope-ith-5mp-hdmi-usb-2-0-cmos-camera","title":"Meiji Techno MT5300EHV-HD - Halogen Ergonomic Trinocular Biological Veterinary Brightfield Compound Microscope with 5MP HDMI\/USB 2.0 CMOS Camera","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eErgonomic Trinocular Biological Veterinary Brightfield Compound Microscope Halogen Model BF\u003c\/li\u003e\n\u003cli\u003ePlan 4X, 10X, 20X, S40X, S100X oil\u003c\/li\u003e\n\u003cli\u003eWith 5MP HDMI\/USB 2.0 CMOS Camera\u003c\/li\u003e\n\u003cli\u003eWith 11.8 HDMI Monitor(HD1000-Lite-M)\u003c\/li\u003e\n\u003cli\u003e0.3X C mount adapter (MA151\/35\/03)\u0026gt;\u003c\/li\u003e\n\u003cli\u003eCompact Space Saving Footprint design with ergonomics in mind\u003c\/li\u003e\n\u003cli\u003eInfinity Corrected Optical System (ICOS™) with all newly designed optics\u003c\/li\u003e\n\u003cli\u003eComfortable Siedentopf-type Binocular and Trinocular Viewing heads\u003c\/li\u003e\n\u003cli\u003eOptional Ergonomic tilting binocular head- Adjustable vertically from 10°to 50° degrees\u003c\/li\u003e\n\u003cli\u003eCeramic Coated Stage with Ergonomically Placed Low Position Drop down Control\u003c\/li\u003e\n\u003cli\u003eLow Positioned Ergonomic Coaxial Focus Control\u003c\/li\u003e\n\u003cli\u003eSmooth Operating Ergonomic Quintuple Nosepiece\u003c\/li\u003e\n\u003cli\u003eBrightfield and Phase Contrast Observation modes available\u003c\/li\u003e\n\u003cli\u003eIntegrated 30-Watt Halogen Transmitted illumination System on selected Brightfield and Phase Contrast Models\u003c\/li\u003e\n\u003cli\u003eAbbe and Zernike Phase Contrast Condensers available\u003c\/li\u003e\n\u003cli\u003eIntegrated Automatic Voltage Sensing Power Supply with localized power cord\u003c\/li\u003e\n\u003cli\u003eWide Range of Filters and Accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBrightfield:\u003c\/strong\u003e\u003cbr\u003eThe simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light and contrast in the sample is caused by absorbance of some of the transmitted light in dense areas of the sample. Brightfield microscopy is the simplest of a range of techniques used for illumination of samples in light microscopes and its simplicity makes it a popular technique. The typical appearance of a brightfield microscopy image is a dark sample on a bright background.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Contrast:\u003c\/strong\u003e\u003cbr\u003eAn optical microscopy technique that converts phase shifts in light passing through a transparent specimen to brightness changes in the image. Phase shifts themselves are invisible, but become visible when shown as brightness variations. When light waves travel through a medium other than vacuum, interaction with the medium causes the wave amplitude and phase to change in a manner dependent on properties of the medium. Changes in amplitude (brightness) arise from the scattering and absorption of light, which is often wavelength-dependent and may give rise to colors. Photographic equipment and the human eye are only sensitive to amplitude variations. Without special arrangements, phase changes are therefore invisible.\u003c\/p\u003e\n\u003cp\u003eThe MT5000V Series is one of our most rugged fully equipped biological microscope systems. Created to meet the demands of researchers and clinical laboratory specialists. The MT5000V Series microscopes feature a new computer engineered rigid frame that incorporates low positioned coaxial coarse\/fine focus controls and ergonomic stage design for maximum efficiency and comfort while providing and extremely stable platform. The cast aluminum alloy metal stand has a chemical resistant finish and is the most rugged, durable finish in the market today. Equipped tension adjustment controls and a built in stage stop lever to protect the specimen and objectives from accidental damage during use. The MT5000V Series offers an outstanding range of optical performance with an emphasis on all newly engineered high performance U. Plan optics. The new optics, provide exceptionally bright, crisp images with good color rendition and superior flat fields of view. The MT5000V Series have bigger stage and 30mm wider eyepiece compared to the MT4000 Series.\u003c\/p\u003e\n\u003cdiv align=\"left\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003eVIEWING HEADS\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003eModel MA815 is the Siedentopf-type binocular head and Model MA816 is the trinocular head for camera integration. Each head has the eyetubes inclined at 30 degrees with the left eyetube having graduated diopter settings. The interpupillary distance is adjustable between 53mm – 75mm. An 80\/20 beamsplitter for the trinocular tube can be engaged for photo work. (100% to eyetubes or 80% to phototube \u0026amp; 20% to the eyetube.) The optional MA957, Ergonomic Binocular Viewing Head, has the inclination adjustable from 10 to 50 degrees to fit users of different heights. The Ergonomic Trinocular model comes with the MA958, photo\/video attachment with sliding 80\/20 beam-splitter (Included in MT5300ED).\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003eEYEPIECES\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e10X Super Widefield High Eyepoint eyepieces F.N.22 are standard, and 15X and 20X eyepieces are available as an option. A Super Widefield High Eyepoint 10X focusable eyepiece that accepts 25mm reticules is also available.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003eOBJECTIVE CHANGER\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003eQuintuple nosepiece provides effortless objective changes with smooth-operating, ball bearing mounted.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003eOBJECTIVES\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003eMeiji Techno America offers an assortment of Planachromat Infinity Corrected (ICOS) objectives for Brightfield, Darkfield and Phase Contrast observation modes.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003eSTAGE\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003eCeramic coated standard right-handed or optional left-handed controls, flat top stage 191mm x 140mm with travel: 80mm(X) x 52mm(Y). Ergonomically positioned coaxial drop down controls. Available with motorized focus and stage controls.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003eCONDENSER\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003eNew design centerable Abbe 1.25 N.A. Condenser with built-in iris diaphragm in dovetail mount.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003eILLUMINATION\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003ePowerful white Halogen illumination provides enhanced image quality and brightness for the observation of specimens and photomicroscopy.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cem\u003ePHOTOMICROGRAPHY\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003eMeiji Techno offers a broad range of digital video cameras which offers excellent sensitivity, high resolution and a wide dynamic range for the most demanding brightfield and darkfield microscopy applications including clinical pathology and cytology, life sciences and geology. Some models has included software, that can preview and capture still shots and live videos to a PC or Mac with USB port or HDMI connectivity.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49496406130986,"sku":"MT5300EHV-HD","price":7645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT5300EHV-HD.webp?v=1730066144"},{"product_id":"meiji-techno-mt5300lv-trinocular-biological-veterinary-brightfield-compound-microscope-1","title":"Meiji Techno MT5300LV-HD Trinocular Biological Veterinary Brightfield Compound Microscope","description":"\u003cp\u003eThe Meiji Techno MT5300LV-HD Trinocular Biological Veterinary Brightfield Compound Microscope is an advanced and versatile tool designed specifically for veterinary professionals and researchers. This high-quality microscope provides excellent optical performance and durability, allowing for precise examinations and detailed observations in biological studies.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with a trinocular head, the microscope supports both binocular and trinocular usage, making it ideal for collaborative work or for capturing images and videos of specimens. The inclined 30° eyepieces provide comfort during extended use, while the ergonomic design ensures that users maintain proper posture, reducing strain during long hours in the lab.\u003c\/p\u003e\n\n\u003cp\u003eThe MT5300LV-HD features a brightfield transmitted light stand that utilizes either LED or Halogen illumination, complete with auto voltage sensing capabilities for global use (110-240V). This versatility ensures that you are prepared to work in any environment, enhancing the practicality of your microscope.\u003c\/p\u003e\n\n\u003cp\u003eThe optical system boasts Planachromat Semi Apo objectives (4x, 10X, 20X, S40X, S100X oil) that are infinity corrected with a focal length of 200mm. This means you receive high-resolution images with superior color fidelity and minimized aberrations.\u003c\/p\u003e\n\n\u003cp\u003eAdditional specifications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10X eyepieces, accepting a 25mm reticle for enhanced viewing.\u003c\/li\u003e\n\u003cli\u003eCeramic coated flat-top stage measuring 190mm x 140mm, with 80mm x 52mm X-Y movement controlled by convenient right-hand drop-down coaxial controls.\u003c\/li\u003e\n\u003cli\u003eCoarse and fine focus knobs with a stage lock and a tension adjustment ring, providing precise control.\u003c\/li\u003e\n\u003cli\u003eAbbe condenser with a numerical aperture of 1.25 and a built-in iris for optimal light management.\u003c\/li\u003e\n\u003cli\u003eTrinocular models equipped with HD1000-LITE and C” mount, including an 11.8” HDMI monitor with mounting brackets for easy image capture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis microscope is not only an indispensable tool for laboratories but also an essential asset for any veterinary practice. Invest in the Meiji Techno MT5300LV-HD for reliable performance, accurate results, and enhanced productivity in your research and diagnostic tasks.\u003c\/p\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49496441848106,"sku":"MT5300LV-HD","price":6340.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT5300EHV-HD.webp?v=1730066144"},{"product_id":"mt5300lv-hd-veterinary-led-trinocular-brightfield-biological-microscope-with-hd1000-lite-m-camera","title":"Meiji Techno MT5300LV - Veterinary LED Trinocular Brightfield Biological Microscope","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eBiological Veterinary Brightfield Compound Microscope (Binocular or Trinocular Inclined at 30°) or Ergonomic Models (Inclined at 10°-50°)\u003c\/li\u003e\n\u003cli\u003e10X Eyepieces -30.0mm Compensating Eyepiece (accepts a 25mm reticle)\u003c\/li\u003e\n\u003cli\u003eBrightfield Transmitted light stand with LED or Halogen and is Auto Voltage sensing 110-240V\u003c\/li\u003e\n\u003cli\u003eEquipped with Planachromat Semi Apo 4x, 10X, 20X, S40X, S100X oil Infinity Corrected Objectives F= 200mm\u003c\/li\u003e\n\u003cli\u003eCeramic coated flat-top stage, 190mmx 140mm, 80mm x 52mm X-Y movement with right hand drop-down coaxial controls\u003c\/li\u003e\n\u003cli\u003eCoarse and Fine focus knob with a stage lock and a tension adjustment ring  Abbe Condenser with N.A. 1.25 with built in Iris\u003c\/li\u003e\n\u003cli\u003eTrinocular Models equipped with HD1000-LITE and 0.3 C” mount (MA151\/35\/03) and 11.8” HDMI monitor with mounting brackets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMeiji Techno America’s MT5200V \u0026amp; MT5300V Veterinary Series is our Preconfigured Compound Biological Series catered to the Veterinary market. The Veterinary series is a usefull tool for any clinical practice. Many Veterinary clinics have in house laboratory microscopes. It you are a starting Veterinarian and in search of the most practical laboratory microscope with a wider field of view and smooth operating mechanical stage with a full suite of Infinity objectives which includes Planachromat 4X, 10X, 20X, 40X, S100X oil. Equipped with a Abbe Condenser that is has a Numerical Aperture of 1.25, coarse and fine focus knobs with a stage lock and tension adjustment ring and a transmitted LED or Halogen light base that is auto-voltage sensing. The Trinocular model is equipped with a CMOS Digital HDMI\/ USB 2.0 camera with a 11.8” HDMI monitor for easy capture and documenting images which can be saved directly onto the supplied SD card( via HDMI) or PC( via USB 2.0) . Measurement and annotation software included and can be accessed when connected directly to a PC via USB 2.0 connection, a 0.3X C” mount adapter is the interface for the camera and microscope for easy plug and play photomicroscopy. It is critical for every practice to have a good tool for performing parasite studies or cytological or fecal, blood parasites, protozoan, Dermatophytes, Ectoparasites, Demodex, Saracoptes, Otodectes, Tricodectes, Linognathus, Common Flea and Brown Dog Thick (Rhipicephalus), Entamoeaba coli., cysts, Lodamoeba, Trophozoites, Trichomonas vaginalis, Echinococuus granulosus, Entamoeba hartmanii, Endolimax nana, Dientamoeba fragilis, Chilomastix mesnili, Microsporidium spp., Giardia lamblia, Eimeria spp., Cryptosporidium spp. Isospora spp., Taenia spp. Ova: (Tapeworm), Dipylidium canimum Ova (Tapeworm), Hookworm Ova, Trichuris spp.Ova, Toxocara canis Ova (Roundworm), Fasciola hepatica, Stongloides Larvae, Necator americanus (Hookworm), Hymenolepsis nana (Tapeworm), Schistosoma japonicum, Ascaris lumbricoides, Schistosoma haematobium, Alaria, Entamoeba histolytica, Entamoeba coli, Endolimax nana, Dientamoeba fragilis, Iodamoeba spp., Cryptosporidium spp., Mycoplasma haemofelis, Leishmania: tropica major, Writht Glemsa, Trypanosoma cruzi, Typanosoma rhodesience, Plasmodium falciparum, Schistosoma mansoni, Dirofilaria immitis microfilaria, Trichinella, Toxoplasma gondii, Tachyzoites , Plasmodium vivax, Acanthamoeba, Trypanosoma lewisi, Anaplasma , Babesia spp, Toxoplasma gondii, Peritoneal Fluid Smear, Onchocerca volvulus, Otodectes cynotis (Ear Mite),Rhipicephalus sanguineus (Brown Dog Tick),Ctenocephalides spp, (Common Flea), Demodex Folliculorum (Mange Mite), Trichodectes spp. (Chewing Louse), Linognathus spp(Sucking Louse), Mycobacterium tuberculosis, Candida albicans, Nocardia spp., Cryptococcus neoformans, Alternaria, Curvularia spp., microsporum canis, Microsporum gypseum, Trchophyton mentogrophytes, Trchophyton rubrum, Aspergillus flavus, Fusarium spp.,Alaria.\u003c\/p\u003e\n\u003cp\u003eAdvancement in microscope standards have led to the development of Meiji Techno Americas Infinity Corrected Optical System ( ICOS) with a standard tube length of 200mm. The objective length, the distance from the object to the shoulder of the objective is showing signs of standardization. Meiji Techno’s Veterinary Series comes in a binocular or trinocular or ergonomic binocular and ergonomic Trinocular models to accommodate users of different heights.\u003c\/p\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49496476451114,"sku":"MT5300LV","price":4850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-MT5300EHV-HD.webp?v=1730066144"},{"product_id":"meiji-techno-mt4200elv-ergonomic-binocular-bio-veterinary-b-f-compound-microscope-led-illum","title":"Meiji Techno, MT4200ELV - Ergonomic Binocular Bio. Veterinary B.F. Compound Microscope, LED Illum.","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"li1\"\u003eCompact Space Saving Footprint design with ergonomics in mind\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eInfinity Corrected Optical System (ICOS) with all newly designed Planachromatic optics\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eCeramic Coated Stage with Ergonomically Placed Low Position Drop down Control\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eParfocalled Microscope Brightfield U. Plan Infinity Corrected Objectives 4X, 10X, 20X, 40X, 100X oil\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eTension adjustment control with Coaxial knobs\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eLow Positioned Ergonomic Coaxial Fine and Coarse Focus Control\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eSmooth Operating Ergonomic Quintuple Nosepiece\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eComfortable Siedentopf-type Binocular and Trinocular Viewing heads\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eOptional Ergonomic tilting binocular head- Adjustable vertically from 10 to 50 degrees\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eSuper Bright LED Koehler illumination, lambertian design\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eIntegrated Automatic Voltage Sensing Power Supply with localized power cord\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eRear Cord Wrap for easy storage \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Veterinary Series is a preconfigured compound biological series designed specifically for the veterinary market. It's an invaluable tool for any clinical practice, equipped with newly upgraded U. Plan Brightfield Objectives and Infinity Corrected optics. This series features Brightfield 4X, 10X, 20X, 40X, and 100X oil objectives.\u003c\/p\u003e\n\u003cp\u003eFor veterinary clinics with in-house laboratory microscopes, or for new veterinarians seeking a practical laboratory microscope, the Veterinary Series offers a wider field of view and a smooth-operating mechanical stage. It comes with a complete set of Infinity objectives, including U. Planachromat 4X, 10X, 20X, 40X, and S100X oil. Additionally, it is equipped with an Abbe Condenser with a Numerical Aperture of 1.25.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Meiji Techno","offers":[{"title":"Default Title","offer_id":49496568561962,"sku":"MT4200ELV","price":4560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/1-fotor-20241107142527.webp?v=1731018504"}],"url":"https:\/\/bluetigerscientific.com\/collections\/meiji-techno-biological-microscopes.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}