{"title":"Major Science Bioreactors \u0026 Pumps","description":"\u003cp\u003eBrowse bioreactors \u0026amp; pumps from Major Science. Compare the available products below, or return to the complete brand range.\u003c\/p\u003e","products":[{"product_id":"major-science-digital-peristaltic-pump-mu-d","title":"Major Science MU-D01 Digital Peristaltic Pump","description":"\u003cdiv id=\"bts-major-mu-d01\" style=\"width:100%;max-width:1400px;margin:0 auto;padding:16px 12px;box-sizing:border-box;background:#fff;color:#26332C;font-family:'Open Sans',sans-serif;font-size:1rem;font-weight:300;line-height:1.75;\"\u003e\n\u003csection style=\"box-sizing:border-box;padding:24px 20px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003cp style=\"font-size:.85rem;letter-spacing:.08em;font-weight:600;color:#245B45;margin:0 0 12px;\"\u003eMAJOR SCIENCE · MU-D01\u003c\/p\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eOne compact pump for changing liquid-handling tasks\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMove from sampling to circulation, feeding or filling with a pump that gives you direct control over speed and direction. The MU-D01 pairs a 50 W brushless motor with digital microprocessor control, letting you adjust speed in 1 rpm steps across its 20 to 300 rpm range.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAn easy-load head accommodates different silicone tubing sizes, so you can choose the fluid path for the job rather than treat every transfer the same. Reversible operation and two-step run\/stop programming add practical flexibility without taking over the bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:600px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-studio.webp?v=1792794640\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-studio.webp?v=1792794640\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-studio.webp?v=1792794640\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-studio.webp?v=1792794640\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-studio.webp?v=1792794640\u0026amp;width=1400 1400w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 600px\" width=\"1692\" height=\"1500\" alt=\"Exact MU-D01 manufacturer reference photograph; confirm current supplied head configuration and tubing separately\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer MU-D01 reference photograph. Confirm the current supplied head and tubing package; accessories are not inferred from a photograph.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:20px;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e20–300 rpm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eDigital speed adjustment in 1 rpm steps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:20px;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003e1.2–1,140 mL\/min\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003ePublished overall range, dependent on tubing selection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:20px;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eReversible + timed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eChange flow direction and program running\/stopping stages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"box-sizing:border-box;padding:24px 20px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWill it cover my transfer and circulation work?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe MU-D01 is designed for laboratory tasks including filtration, circulation, sampling, dispensing, transferring, feeding and filling. Its adjustable speed gives you a practical way to tune the pump to each setup.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMajor Science specifies an overall flow range of 1.2 to 1,140 mL\/min, depending on the silicone tubing used. Select tubing for your required working range and verify the delivered flow under your actual operating conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:700px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-pump-speed-tubing-delivered-flow-guide.webp?v=1792794640\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-pump-speed-tubing-delivered-flow-guide.webp?v=1792794640\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-pump-speed-tubing-delivered-flow-guide.webp?v=1792794640\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-pump-speed-tubing-delivered-flow-guide.webp?v=1792794640\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-pump-speed-tubing-delivered-flow-guide.webp?v=1792794640\u0026amp;width=1400 1400w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 700px\" width=\"1400\" height=\"1200\" alt=\"MU-D01 selection workflow: choose tubing, set 20 to 300 rpm speed, then verify delivered flow; no universal rpm-to-flow conversion\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eA source-grounded selection guide: speed setting alone does not guarantee a specific delivered flow.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:24px 0px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:470px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-control-detail.webp?v=1792794640\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-control-detail.webp?v=1792794640\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-control-detail.webp?v=1792794640\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-control-detail.webp?v=1792794640\u0026amp;width=824 824w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 470px\" width=\"824\" height=\"984\" alt=\"Digital controls cropped from the exact MU-D01 manufacturer photograph\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eDigital-control detail from the exact MU-D01 manufacturer reference photograph. Displayed settings are illustrative.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eHow much control do I have at the bench?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eDigital microprocessor control lets you select a speed from 20 to 300 rpm in 1 rpm increments. The 50 W brushless motor provides the drive, while the front-panel display keeps the speed setting visible during setup.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eReversible operation helps when you need to change the direction of transfer or purge the line. Speed control is not a substitute for checking delivered volume, especially when tubing or process conditions change.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:24px 0px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eCan I build pauses into the workflow?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe two-step program combines a running stage with a stopping stage. With a maximum timer setting of 99 hours, 59 minutes and 59 seconds, the MU-D01 supports timed operation as well as straightforward speed-controlled pumping.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAn auto-resume function is also specified. Account for that behavior in your laboratory's operating procedure, particularly when planning work around interruptions to the power supply.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:24px 0px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:700px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-silicone-tubing-inner-diameter-wall-guide.webp?v=1792794640\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-silicone-tubing-inner-diameter-wall-guide.webp?v=1792794640\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-silicone-tubing-inner-diameter-wall-guide.webp?v=1792794640\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-silicone-tubing-inner-diameter-wall-guide.webp?v=1792794640\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/mu-d01-silicone-tubing-inner-diameter-wall-guide.webp?v=1792794640\u0026amp;width=1400 1400w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 700px\" width=\"1400\" height=\"1200\" alt=\"Tubing geometry guide: inner diameter is the fluid passage; all six listed silicone tube walls are 1.6 mm; barb size is a different dimension\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eOriginal tubing-dimension guide based on the manufacturer-listed I.D. and wall data. Cross-section is illustrative, not a scale drawing.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWhich tubing should I choose?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eMajor Science lists silicone tubing MU-S13, MU-S14, MU-S16 and MU-S25 with internal diameters of 0.8, 1.6, 3.1 and 4.8 mm respectively. MU-S17 and MU-S18 extend the listed choices to 6.4 and 7.9 mm. All six have a specified wall thickness of 1.6 mm.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eTubing choice affects the achievable flow range and the suitability of the fluid path for your sample. Check material compatibility and the operating requirements of your complete setup before selecting tubing; one size does not deliver the full published range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003cdiv data-bts-accessory-slot=\"accessory-proof\"\u003e\u003c\/div\u003e\n\u003csection style=\"box-sizing:border-box;padding:24px 0px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eTubing selection: separate I.D. from fitting size\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe manufacturer lists the following silicone tubing accessories, each with a 1.6 mm wall and a 25 ft accessory length. Tubing is a separate selection; these rows are not a statement that every size comes with the pump.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #e0e0e0; table-layout:fixed;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background: #f5f5f5; text-align: left; padding: 12px; font-weight: 700;width:34%;\"\u003eTube catalog no.\u003c\/th\u003e\n\u003cth style=\"background: #f5f5f5; text-align: left; padding: 12px; font-weight: 700;width:66%;\"\u003eDimensions and fitting reference\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003eMU-S13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003eI.D. 0.8 mm; wall 1.6 mm; hose barb 1\/16 in (1.6 mm); listed accessory length 25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003eMU-S14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003eI.D. 1.6 mm; wall 1.6 mm; hose barb 1\/16 in (1.6 mm); listed accessory length 25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003eMU-S16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003eI.D. 3.1 mm; wall 1.6 mm; hose barb 1\/8 in (3.2 mm); listed accessory length 25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003eMU-S25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003eI.D. 4.8 mm; wall 1.6 mm; hose barb 3\/16 in (4.8 mm); listed accessory length 25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003eMU-S17\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003eI.D. 6.4 mm; wall 1.6 mm; hose barb 1\/4 in (6.4 mm); listed accessory length 25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003e\u003cstrong\u003eMU-S18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; vertical-align:top; overflow-wrap:anywhere; box-sizing:border-box;\"\u003eI.D. 7.9 mm; wall 1.6 mm; hose barb 3\/8 in (9.5 mm); listed accessory length 25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe hose-barb dimension describes the fitting, not the tubing bore. Select the material and dimensions for your liquid, head and connections.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eWhy there is no fixed flow-by-tube chart here:\u003c\/strong\u003e The manufacturer accessory flow table uses a 6–600 rpm reference drive. MU-D01 itself operates at 20–300 rpm, so that generic table is not presented as this pump's guaranteed delivery chart.\u003c\/p\u003e\u003c\/section\u003e\n\u003cdiv data-bts-accessory-slot=\"mud01-tubing\"\u003e\u003c\/div\u003e\n\u003csection style=\"box-sizing:border-box;padding:24px 20px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;background:#F1F7F3;border-radius:10px;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eCan the setup grow to a second fluid line?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe MU-D01 is specified in a one-head configuration and supports a maximum of two heads. A second head is optional and must be confirmed before ordering, making expansion a deliberate configuration choice rather than an assumed accessory.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eWith the dual-head arrangement, two silicone tubes operate at the same pump speed. This is useful when your setup calls for two lines on one drive, but it does not provide independent speed control or guarantee equal flow through different tubes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:850px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-d02-head-options.webp?v=1792794640\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-d02-head-options.webp?v=1792794640\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-d02-head-options.webp?v=1792794640\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-d02-head-options.webp?v=1792794640\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-d02-head-options.webp?v=1792794640\u0026amp;width=1000 1000w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 850px\" width=\"1000\" height=\"438\" alt=\"Manufacturer MU-D01 and MU-D02 loading and optional second-head illustration; second head is not included by default\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eManufacturer MU-D01\/MU-D02 family illustration: the second expandable head is optional. This does not define the supplied head revision or tubing contents.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:24px 0px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 340px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\u003cfigure style=\"margin:0 auto;width:100%;max-width:480px;box-sizing:border-box;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-head-detail.webp?v=1792794640\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-head-detail.webp?v=1792794640\u0026amp;width=375 375w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-head-detail.webp?v=1792794640\u0026amp;width=640 640w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-head-detail.webp?v=1792794640\u0026amp;width=960 960w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/major-science-mu-d01-head-detail.webp?v=1792794640\u0026amp;width=1128 1128w\" sizes=\"(max-width: 767px) calc(100vw - 72px), 480px\" width=\"1128\" height=\"1200\" alt=\"Pump-head detail from the MU-D01 reference photograph; not a promise of the current head brand or accessory package\" loading=\"lazy\" style=\"display:block;width:100%;max-width:100%;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:0.85rem;line-height:1.55;color:#526358;margin-top:10px;\"\u003eHead detail from the MU-D01 manufacturer reference photograph. No particular head brand or revision is promised by this image.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 360px;min-width:min(260px,100%);box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWhat should I plan for before installation?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eAllow approximately 200 by 340 by 130 mm for the unit itself, plus space for tubing and access to the head. The painted iron housing weighs approximately 5.7 kg, and the specified operating temperature is ambient to 40°C.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eThe MU-D01 requires selection of a 110 V or 220 V supply configuration, not a universal-voltage assumption. Confirm the ordered electrical configuration and your tubing requirements before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:24px 0px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eA practical transfer workflow\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:20px;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eChoose and route\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSelect suitable tubing and connections, then plan access around the head and receiving vessel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:20px;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eSet and check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eSet the speed and direction, then verify delivered flow under the actual working conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;box-sizing:border-box;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:8px;padding:20px;\"\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;color:#245B45;\"\u003e\u003cstrong\u003eDocument the setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eRecord tube size, liquid, speed, timing and relevant load conditions so recurring work starts from a known configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"box-sizing:border-box;padding:24px 0px;margin:0 0 24px;border-bottom:1px solid #B7D0BF;\"\u003e\u003ch2 style=\"font-family:Open Sans,sans-serif;font-size:1.35rem;font-weight:600;line-height:1.35;color:#245B45;margin:0 0 18px;\"\u003eWhat does the MU-D01 order cover?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eCatalog number MU-D01:\u003c\/strong\u003e The digital peristaltic pump is listed in a one-head configuration, with an optional second-head arrangement available for confirmation before ordering.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003eDo not assume a silicone-tubing assortment, a particular tubing length, a named head brand or a local plug from the photographs. If your order depends on a specific head, tubing or electrical configuration, ask Blue Tiger Scientific to confirm that requirement.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;font-weight:300;line-height:1.75;margin:0 0 14px;\"\u003e\u003cstrong\u003eBench tip:\u003c\/strong\u003e Changing tubing can change delivered flow even when the rpm setting stays the same. Verify the transfer after a tubing or process change rather than treating speed increments as a volumetric-accuracy specification.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv class=\"faq_block\" style=\"border-top:1px solid #e0e0e0;margin-top:24px;\"\u003e\u003cdiv itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"width: 100%; padding: 20px 0; font-family: 'Open Sans', sans-serif; font-weight: 300; color: #333; line-height:1.15; box-sizing:border-box;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eMU-D01 buyer questions\u003c\/h3\u003e\n\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhat flow rate can I get from the MU-D01?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eMajor Science specifies an overall range of 1.2 to 1,140 mL\/min for the MU-D01, depending on silicone tubing selection. That is not the range of every tube size. Verify the delivered flow with your chosen tubing, liquid and operating conditions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow finely can I adjust MU-D01 speed?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe MU-D01 adjusts from 20 to 300 rpm in 1 rpm increments. This is a speed-setting specification, not a stated volumetric dosing accuracy.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan the MU-D01 reverse flow?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. The MU-D01 is reversible, including for purging purposes, so you can change the direction of pumping to suit the task.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eDoes the MU-D01 support timed operation?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. The MU-D01 has a two-step program for running and stopping, with a maximum timer setting of 99 hours, 59 minutes and 59 seconds. Major Science also specifies auto resume, which should be considered in your operating procedure.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eWhich silicone tubing sizes are listed for the MU-D01?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe listed options are MU-S13 at 0.8 mm ID, MU-S14 at 1.6 mm ID, MU-S16 at 3.1 mm ID, MU-S25 at 4.8 mm ID, MU-S17 at 6.4 mm ID and MU-S18 at 7.9 mm ID. All six have a 1.6 mm wall thickness. Check tubing compatibility with your liquid and confirm your tubing order separately.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eCan I add a second head to the MU-D01?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eYes. The MU-D01 supports up to two heads, but the second head is optional and requires confirmation before ordering. Both lines run at the same pump speed, rather than at independently controlled speeds.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eIs the MU-D01 a universal-voltage pump?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eNo. Major Science lists the MU-D01 as 110 V or 220 V selectable, rather than universal 100 to 240 V input. The BTS-MU-D01 SKU does not establish which configuration will be supplied, so confirm the voltage selection before ordering.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemprop=\"mainEntity\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border: 1px solid #e0e0e0; border-radius: 8px; margin: 0 0 10px 0; background: #fff;\"\u003e\u003csummary itemprop=\"name\" style=\"cursor: pointer; padding: 14px 16px; font-size: 1rem; font-weight: 600; list-style-position: inside;\"\u003eHow much bench space does the MU-D01 need?\u003c\/summary\u003e\u003cdiv itemprop=\"acceptedAnswer\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Answer\" style=\"padding: 0 16px 14px 16px;\"\u003e\u003cp itemprop=\"text\" style=\"font-size: 0.97rem; line-height: 1.6; margin: 0;\"\u003eThe MU-D01 measures approximately 200 mm wide by 340 mm long by 130 mm high and weighs approximately 5.7 kg. Leave additional room for tubing routing and head access. Its specified operating temperature is ambient to 40°C.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Major Science","offers":[{"title":"Default Title","offer_id":50042105692458,"sku":"BTS-MU-D01","price":2140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/MU-D01.png?v=1742675435"},{"product_id":"winpact-fs-05-parallel-bioreactor","title":"Major Science Winpact FS-05 Parallel Bioreactor","description":"\u003carticle aria-label=\"Winpact FS-05 parallel bioreactor product guide\" class=\"wp-story\"\u003e\n\u003csection aria-labelledby=\"wp-title\" class=\"wp-hero\" id=\"wp-overview\"\u003e\n\u003cdiv class=\"wp-hero-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eBlue Tiger Scientific · Winpact\u003c\/p\u003e\n\u003ch1 id=\"wp-title\"\u003eWinpact FS-05 Parallel Bioreactor\u003c\/h1\u003e\n\u003cp class=\"wp-lead\"\u003ePut your next two experiments side by side.\u003c\/p\u003e\n\u003cp\u003eCompare culture conditions, explore a new feed strategy or run different vessel configurations from one controller. The FS-05 brings two independently controlled vessels together on a shared platform, with a clear touchscreen and dedicated pumping capacity for each run.\u003c\/p\u003e\n\u003cdiv class=\"wp-actions\"\u003e\n\u003cbutton class=\"wp-button\" data-wp-open=\"\" type=\"button\"\u003eRequest a Configured Quote\u003c\/button\u003e\u003ca class=\"wp-text-link\" href=\"#wp-vessels\"\u003eExplore vessel choices \u003cspan aria-hidden=\"true\"\u003e↓\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eConfigured for your process—not a fixed bundle of every vessel pictured.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"wp-hero-image\"\u003e\u003cimg alt=\"Winpact FS-05 controller with touchscreen, eight pump heads and two flowmeters\" height=\"1000\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-hero.webp?v=1792798224\" width=\"1000\"\u003e\n\u003cfigcaption\u003eThe FS-05 controller: one interface, two vessel channels.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/section\u003e\n\u003cdiv aria-label=\"FS-05 at a glance\" class=\"wp-spec-band\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e2 vessels\u003c\/strong\u003e\u003cspan\u003eper controller\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e0.5–20 L\u003c\/strong\u003e\u003cspan\u003eworking-volume family*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e8 pumps\u003c\/strong\u003e\u003cspan\u003e4 per vessel\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e10.4-inch\u003c\/strong\u003e\u003cspan\u003ecolour touchscreen\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-band-note\"\u003e*Available working volumes depend on vessel type and heating arrangement; not one adjustable 0.5–20 L vessel.\u003c\/p\u003e\n\u003csection aria-labelledby=\"wp-paired-title\" class=\"wp-section wp-split\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003cimg alt=\"Example FS-05 two-vessel arrangement\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-ai_system-v2.webp?v=1792811356\" width=\"1200\"\u003e\n\u003cfigcaption\u003eExample FS-05 two-vessel arrangement. Vessel sizes and accessories are selected for your project.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eTwo runs. One workspace.\u003c\/p\u003e\n\u003ch2 id=\"wp-paired-title\"\u003eMake comparison part of the workflow.\u003c\/h2\u003e\n\u003cp\u003eRun the same experiment in both vessels or give each a different task. Compatible sizes and vessel types can differ, helping you plan paired studies without requiring identical hardware on both sides.\u003c\/p\u003e\n\u003cp\u003eDuo heating supports two thermostat-heated runs, two dry-heated runs, or one of each. Choose the arrangement around your culture and utilities rather than assuming every vessel uses the same temperature-control method.\u003c\/p\u003e\n\u003cul class=\"wp-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia development:\u003c\/strong\u003e compare formulations under defined control settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeed optimisation:\u003c\/strong\u003e investigate substrate delivery and process responses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCulture development:\u003c\/strong\u003e select stirred, air-lift or solid-state configurations to suit the work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-parallel-title\" class=\"wp-section wp-tint\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eThe parallel concept\u003c\/p\u003e\n\u003ch2 id=\"wp-parallel-title\"\u003eShared controller. Separate experiments.\u003c\/h2\u003e\n\u003cp\u003eFour built-in pump heads per vessel can be assigned to acid, base, antifoam and substrate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csvg aria-labelledby=\"wp-diagram-title wp-diagram-desc\" class=\"wp-diagram\" role=\"img\" viewbox=\"0 0 960 250\"\u003e\u003ctitle id=\"wp-diagram-title\"\u003eFS-05 two-vessel control concept\u003c\/title\u003e\n\u003cdesc id=\"wp-diagram-desc\"\u003eOne FS-05 controller connects to vessel A and vessel B. Each vessel has four built-in pump heads assigned to its channel. Compatible vessel sizes and heating methods can differ.\u003c\/desc\u003e\u003cg fill=\"none\" stroke=\"#235c86\" stroke-width=\"3\"\u003e\u003cpath d=\"M350 105H235V65H175M610 105H725V65H785\"\u003e\u003c\/path\u003e\u003crect fill=\"white\" height=\"155\" rx=\"18\" width=\"260\" x=\"350\" y=\"42\"\u003e\u003c\/rect\u003e\u003cpath d=\"M110 40v145q0 25 35 25h40q35 0 35-25V40M740 40v145q0 25 35 25h40q35 0 35-25V40\"\u003e\u003c\/path\u003e\u003cpath d=\"M110 135h110M740 135h110\" stroke=\"#245B45\"\u003e\u003c\/path\u003e\u003c\/g\u003e\u003cg fill=\"#13314e\" font-family=\"Arial, sans-serif\" text-anchor=\"middle\"\u003e\u003ctext font-size=\"26\" font-weight=\"700\" x=\"480\" y=\"90\"\u003eFS-05\u003c\/text\u003e\u003ctext font-size=\"18\" x=\"480\" y=\"121\"\u003eOne controller\u003c\/text\u003e\u003ctext font-size=\"16\" x=\"480\" y=\"153\"\u003e10.4-inch touchscreen\u003c\/text\u003e\u003ctext font-size=\"23\" font-weight=\"700\" x=\"165\" y=\"96\"\u003eA\u003c\/text\u003e\u003ctext font-size=\"23\" font-weight=\"700\" x=\"795\" y=\"96\"\u003eB\u003c\/text\u003e\u003ctext font-size=\"17\" x=\"165\" y=\"239\"\u003e4 pump heads\u003c\/text\u003e\u003ctext font-size=\"17\" x=\"795\" y=\"239\"\u003e4 pump heads\u003c\/text\u003e\u003c\/g\u003e\u003c\/svg\u003e\n\u003cp class=\"wp-small wp-center\"\u003eConcept diagram, not a piping schematic or a performance comparison.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-vessel-title\" class=\"wp-section\" id=\"wp-vessels\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eStart with the culture\u003c\/p\u003e\n\u003ch2 id=\"wp-vessel-title\"\u003eChoose the vessel—not just the litre number.\u003c\/h2\u003e\n\u003cp\u003eWorking volume is the intended culture volume; total volume includes headspace. Two vessels labelled “5 L working” can have different total capacities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-vessel-photo-guide\"\u003e\n\u003cp class=\"wp-guide-intro\"\u003eFive vessel approaches. See the hardware, then compare how each fits your process.\u003c\/p\u003e\n\u003cdiv class=\"wp-vessel-photo-cards\"\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-A family jacketed vessel, cropped from manufacturer FS-05 system photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_jacketed-v2.webp?v=1792811351\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-A family jacketed vessel, cropped from manufacturer FS-05 system photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_jacketed-v2.webp?v=1792811351\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-A family\u003c\/p\u003e\n\u003ch3\u003eJacketed glass\u003c\/h3\u003e\n\u003cp\u003eA jacketed vessel option for thermostat-based temperature control. Select the working volume and culture requirements together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-B family vessel with heating blanket, manufacturer photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_blanket-v2.webp?v=1792811351\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-B family vessel with heating blanket, manufacturer photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_blanket-v2.webp?v=1792811351\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-B family\u003c\/p\u003e\n\u003ch3\u003eBlanket heating\u003c\/h3\u003e\n\u003cp\u003eA single-wall vessel with an external heating blanket. Available capacities depend on the selected vessel configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-C053 single-wall air-lift vessel, 5 L working volume, manufacturer catalogue photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_airlift-v2.webp?v=1792811352\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-C053 single-wall air-lift vessel, 5 L working volume, manufacturer catalogue photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_airlift-v2.webp?v=1792811352\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-C053 example\u003c\/p\u003e\n\u003ch3\u003eAir-lift mixing\u003c\/h3\u003e\n\u003cp\u003eGas circulation rather than an agitation motor. This 5 L single-wall example has no temperature control; jacketed options differ.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-D family vessel with heating base, manufacturer photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_base-v2.webp?v=1792811352\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-D family vessel with heating base, manufacturer photograph\" height=\"520\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_base-v2.webp?v=1792811352\" width=\"400\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-D family\u003c\/p\u003e\n\u003ch3\u003eBase heating\u003c\/h3\u003e\n\u003cp\u003eA plain-bottom vessel and heating base. Match the selected capacity, heating method and cooling arrangement to the process.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-vessel-photo-card\"\u003e\n\u003cfigure class=\"wp-vessel-photo\"\u003e\u003ca aria-label=\"Open larger image: FS-V-SA05P 5 L solid-state vessel, original manufacturer photograph\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_solid-v2.webp?v=1792811353\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-SA05P 5 L solid-state vessel, original manufacturer photograph\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-vessel_solid-v2.webp?v=1792811353\" width=\"1200\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eExample vessel configuration.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-vessel-card-copy\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFS-V-SA05P · 5 L\u003c\/p\u003e\n\u003ch3\u003eSolid-state culture\u003c\/h3\u003e\n\u003cp\u003eA specialist vessel and handling assembly for solid substrates. Sensing and handling requirements differ from liquid culture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003ePhotographs show configuration examples, not a five-vessel package. Liquid colors are illustrative. Each selected vessel has its own working and total capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection aria-labelledby=\"wp-vessel-overview-heading\" class=\"wp-supplied-overview\" data-wp-addition=\"vessel-overview\"\u003e\u003ch3 id=\"wp-vessel-overview-heading\"\u003eWinpact bioreactor vessel formats, side by side\u003c\/h3\u003e\n\u003cp\u003eUse this overview to orient yourself, then match the vessel family, working volume and heating approach to your process.\u003c\/p\u003e\n\u003cfigure class=\"wp-supplied-wide\"\u003e\u003ca aria-label=\"Open larger Winpact vessel illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-overview.webp?v=1792813449\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Winpact bioreactor vessel-format overview: stirred, air-lift, heated and solid-state examples\" decoding=\"async\" height=\"848\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-overview.webp?v=1792813449\" width=\"2336\"\u003e\u003c\/a\u003e\u003cfigcaption\u003eVessel-format overview. Examples are not drawn to scale and are not a package of included vessels.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv class=\"wp-supplied-mobile\"\u003e\n\u003cfigure class=\"wp-supplied-detail\"\u003e\u003ca aria-label=\"Open larger Winpact vessel illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-liquid-detail.webp?v=1792813449\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Detail of stirred and air-lift vessel examples in the Winpact vessel overview\" decoding=\"async\" height=\"848\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-liquid-detail.webp?v=1792813449\" width=\"930\"\u003e\u003c\/a\u003e\u003cfigcaption\u003eDetail: stirred glass and air-lift vessel examples.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cfigure class=\"wp-supplied-detail\"\u003e\u003ca aria-label=\"Open larger Winpact vessel illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-heated-solid-detail.webp?v=1792813450\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Detail of heated and solid-state vessel examples in the Winpact vessel overview\" decoding=\"async\" height=\"848\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-vessel-heated-solid-detail.webp?v=1792813450\" width=\"1406\"\u003e\u003c\/a\u003e\u003cfigcaption\u003eDetail: heated and solid-state vessel examples.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cul class=\"wp-vessel-legend\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e1–2:\u003c\/strong\u003e Stirred glass vessel examples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3–4:\u003c\/strong\u003e Air-lift vessel examples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5:\u003c\/strong\u003e Heating-blanket format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6:\u003c\/strong\u003e Heating-base format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7:\u003c\/strong\u003e Solid-state format\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"wp-small\"\u003eThe positioning angles shown apply to the illustrated 5 L solid-state design. Available sizes, heating and sensing depend on the selected configuration.\u003c\/p\u003e\u003c\/section\u003e\n\u003cdiv class=\"wp-table-wrap\"\u003e\n\u003ctable data-wp-mobile-table=\"true\"\u003e\n\u003ccaption\u003eIllustrative 5 L working-volume choices\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eVessel configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWorking \/ total\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSelection consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eJacketed dish-bottom\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.8 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eThermostat-based temperature control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eSingle-wall + blanket\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.8 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eDry heating; family extends to 20 L working\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eAir-lifter\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 7 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eDraft tube and micro-sparger; no agitation motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003ePlain-bottom + heating base\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.7 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eBase-heated arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Vessel configuration\" scope=\"row\"\u003eSolid-state\u003c\/th\u003e\n\u003ctd data-wp-column=\"Working \/ total\"\u003e5 \/ 6.8 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"Selection consideration\"\u003eSpecialist configuration; confirm sensing and handling needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eSingle-wall air-lifters have no temperature control; jacketed versions are available. Vessel bodies are borosilicate glass with 316L stainless-steel headplates and fittings.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-solid-visual-title\" class=\"wp-section wp-tint\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eA different cultivation format\u003c\/p\u003e\n\u003ch2 id=\"wp-solid-visual-title\"\u003eTake a closer look at solid-state fermentation.\u003c\/h2\u003e\n\u003cp\u003eThe 5 L FS-V-SA05P is a specialist alternative to the liquid-culture vessels. Its assembly supports vessel positioning and harvesting as well as mixing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-two-cards\"\u003e\n\u003cdiv class=\"wp-solid-visual\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: FS-V-SA05P 5 L solid-state vessel and handling assembly\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-ai_solid-v2.webp?v=1792811357\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-V-SA05P 5 L solid-state vessel and handling assembly\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-ai_solid-v2.webp?v=1792811357\" width=\"1200\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eFS-V-SA05P 5 L solid-state vessel and handling assembly.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-solid-visual\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: Manufacturer feature graphic of FS-V-SA05P solid-state tilting and harvesting positions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-solid_motion-v2.webp?v=1792811355\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Manufacturer feature graphic of FS-V-SA05P solid-state tilting and harvesting positions\" height=\"1200\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-solid_motion-v2.webp?v=1792811355\" width=\"1200\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eManufacturer feature graphic: the illustrated 5 L design supports 0–90° culture positioning and 120° harvesting. This does not describe every solid-state size.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-solid-caption\"\u003e\n\u003ch3\u003eSpecify the material and handling needs.\u003c\/h3\u003e\n\u003cp\u003eTell us the substrate characteristics, intended capacity and mixing needs. pH and DO sensing are optional in the published solid-state configuration, rather than assumed liquid-culture inclusions.\u003c\/p\u003e\n\u003cbutton class=\"wp-button\" data-wp-open=\"\" type=\"button\"\u003eDiscuss solid-state options\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-heating-title\" class=\"wp-section wp-split wp-reverse\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003cimg alt=\"FS-05 with two glass vessels, one fitted with a red heating blanket\" height=\"1000\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-mixed.webp?v=1792798227\" width=\"1000\"\u003e\n\u003cfigcaption\u003eA mixed arrangement illustrates different heating approaches on the same controller.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eMake the specification practical\u003c\/p\u003e\n\u003ch2 id=\"wp-heating-title\"\u003ePlan the complete bench setup.\u003c\/h2\u003e\n\u003cp\u003eMost listed controlled vessel configurations operate from 5°C above coolant temperature to 60°C; base-heated vessels extend to 90°C. These are configuration-specific ranges, not a universal 5–90°C claim.\u003c\/p\u003e\n\u003cp\u003eThe FS-05 requires 210–230 V, 50–60 Hz supply. Plan for dry, oil-free, filtered air at 0.5–2 bar and water at 0.4–1 bar. Supplied cooling water must be at least 15°C below the operating setpoint.\u003c\/p\u003e\n\u003cp\u003eController dimensions are 400 × 549 × 740 mm (W × L × H). Add space for both vessels, tubing, utilities and access—and check autoclave clearance with the condenser attached.\u003c\/p\u003e\n\u003cbutton class=\"wp-button wp-button-secondary\" data-wp-open=\"\" type=\"button\"\u003eCheck my bench and utilities\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-controls-title\" class=\"wp-section wp-split\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003cimg alt=\"Annotated FS-05 controller showing screen, pumps, USB connection, power switch and flowmeters\" height=\"1182\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-anatomy.webp?v=1792798228\" width=\"1000\"\u003e\n\u003cfigcaption\u003eController anatomy: A touchscreen; B pumps; C USB; D power; E flowmeters; F front panel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eControl with context\u003c\/p\u003e\n\u003ch2 id=\"wp-controls-title\"\u003eKeep routine adjustments close at hand.\u003c\/h2\u003e\n\u003cp\u003eThe touchscreen brings process settings and pump control into one interface. Built-in pumps run at 0–65 rpm in 1 rpm increments; 15-step programming supports structured process sequences.\u003c\/p\u003e\n\u003cp\u003eUSB export and Ethernet remote communication help connect bench work with review. An external PC can network up to 16 FS-05 controllers for up to 32 vessels—not 32 vessels directly connected to one controller.\u003c\/p\u003e\n\u003cp\u003eChoose advanced capabilities deliberately: EZScript, external pumps and additional analytical devices are options to discuss with your configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-pump-detail-title\" class=\"wp-section wp-split wp-detail-feature\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: FS-05 eight built-in pump heads and two flowmeters, original detail\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-pump_detail-v2.webp?v=1792811354\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"FS-05 eight built-in pump heads and two flowmeters, original detail\" height=\"456\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-pump_detail-v2.webp?v=1792811354\" width=\"466\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eFS-05 close-up: eight pump heads, with four assigned to each vessel channel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eLook at the details\u003c\/p\u003e\n\u003ch2 id=\"wp-pump-detail-title\"\u003eDedicated feeds for each experiment.\u003c\/h2\u003e\n\u003cp\u003eThe two banks of four built-in pump heads give each vessel its own pumping capacity. Assign them to acid, base, antifoam and substrate according to the selected process.\u003c\/p\u003e\n\u003cp\u003eTell us how many separate feeds you expect to use. If your work needs additional feeds, external pumps are a configuration discussion—not something to infer from the photograph.\u003c\/p\u003e\n\u003cbutton class=\"wp-button wp-button-secondary\" data-wp-open=\"\" type=\"button\"\u003ePlan my feeds\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-software-title\" class=\"wp-section wp-software\"\u003e\n\u003ch2 id=\"wp-software-title\"\u003eSee the controls, one screen at a time.\u003c\/h2\u003e\n\u003cp\u003eExplore the shared Winpact interface with individual views instead of a compressed screenshot strip.\u003c\/p\u003e\n\u003cdiv class=\"wp-interface-cards\"\u003e\n\u003carticle class=\"wp-interface-card\"\u003e\n\u003cfigure class=\"wp-screen-photo\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact manual-control screen, original manufacturer screenshot\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_manual-v2.webp?v=1792811357\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact manual-control screen, original manufacturer screenshot\" height=\"269\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_manual-v2.webp?v=1792811357\" width=\"333\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact interface view.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eManual process control\u003c\/h3\u003e\n\u003cp\u003eA view of individual process parameters and their control settings.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-interface-card\"\u003e\n\u003cfigure class=\"wp-screen-photo\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact sequence-control screen, original manufacturer screenshot\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_sequence-v2.webp?v=1792811358\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact sequence-control screen, original manufacturer screenshot\" height=\"269\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_sequence-v2.webp?v=1792811358\" width=\"333\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact interface view.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSequence planning\u003c\/h3\u003e\n\u003cp\u003eA view of programmed steps for a structured process sequence.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"wp-interface-card\"\u003e\n\u003cfigure class=\"wp-screen-photo\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact pump-control screen, original manufacturer screenshot\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_pumps-v2.webp?v=1792811359\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact pump-control screen, original manufacturer screenshot\" height=\"269\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-screen_pumps-v2.webp?v=1792811359\" width=\"334\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact interface view.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePump settings\u003c\/h3\u003e\n\u003cp\u003eA view of pump controls and feed settings for the selected process.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eShared interface examples. Optional functionality, including EZScript, is selected with the configuration. Open any screen image for its full-size source view.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-remote-view-title\" class=\"wp-section wp-split\"\u003e\n\u003cfigure class=\"wp-media\"\u003e\u003ca aria-label=\"Open larger image: Shared Winpact remote interface, manufacturer screenshot; computer not included\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-remote_screen-v2.webp?v=1792811354\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Shared Winpact remote interface, manufacturer screenshot; computer not included\" height=\"381\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-remote_screen-v2.webp?v=1792811354\" width=\"645\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eWinpact remote-interface view. External PC and network equipment are not included.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eConnect the bench to review\u003c\/p\u003e\n\u003ch2 id=\"wp-remote-view-title\"\u003eA closer look at remote monitoring.\u003c\/h2\u003e\n\u003cp\u003eFS-05 supports Ethernet remote communication. The published architecture allows an external PC to connect up to 16 FS-05 controllers, representing up to 32 vessel channels.\u003c\/p\u003e\n\u003cp\u003eInclude your networking and data-review needs in the enquiry so that software, interfaces and any required external equipment can be scoped together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-package-title\" class=\"wp-section wp-tint\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eA clear scope of supply\u003c\/p\u003e\n\u003ch2 id=\"wp-package-title\"\u003eSpecify what you need. Know what is optional.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-two-cards\"\u003e\n\u003cdiv class=\"wp-card\"\u003e\n\u003ch3\u003eBasic liquid-culture configuration\u003c\/h3\u003e\n\u003cp\u003eController, rotameter and built-in pumps; selected vessel assembly; pH, DO, temperature and foam\/level sensing. Stirred vessels specify a brushless motor, impellers and baffles, with condenser and sparger.\u003c\/p\u003e\n\u003cp\u003eA start-up kit lists silicone tubing, clamps, metal connector and autoclavable disc filters. Final quantities follow the agreed two-vessel bill of materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-card\"\u003e\n\u003ch3\u003eConfigure separately\u003c\/h3\u003e\n\u003cp\u003eVessel sizes and heating arrangements; water circulator\/chiller; ORP, optical density, gas mixing, oxygen enrichment, mass-flow control, off-gas analysis, lighting, external pumps and EZScript.\u003c\/p\u003e\n\u003cp\u003eBlankets or bases accompany the correspondingly named vessel configuration—not every vessel. Solid-state sensing differs from liquid-culture configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-card\" data-wp-brochure-refinement=\"process-options\" style=\"margin-top:24px\"\u003e\n\u003ch3\u003eMatch the options to the job\u003c\/h3\u003e\n\u003cul class=\"wp-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen-control needs:\u003c\/strong\u003e describe whether the process uses air, oxygen enrichment or mixed gases. External oxygen and gas mixing require the appropriate optional hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent feeds:\u003c\/strong\u003e list acid, base, antifoam and nutrient feeds separately. FS-05 provides four built-in pump heads per vessel; additional feeding lines require a configured expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional monitoring:\u003c\/strong\u003e tell us if ORP, off-gas measurements, optical density, lighting or remote monitoring are needed. These are separate selection decisions, not blanket standard inclusions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferent conditions in each vessel:\u003c\/strong\u003e specify both working volumes and any differences in temperature, mixing, gas strategy and sensing so that both channels can be quoted together.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-compare-title\" class=\"wp-section\" id=\"wp-compare\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eFind your fit\u003c\/p\u003e\n\u003ch2 id=\"wp-compare-title\"\u003eFS-05, FS-06 or FS-07?\u003c\/h2\u003e\n\u003cp\u003eChoose by experimental layout, vessel range and expansion needs—not model number alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-card\" data-wp-brochure-refinement=\"model-selection\" style=\"margin:24px 0\"\u003e\n\u003ch3\u003eChoose the controller around the experiment\u003c\/h3\u003e\n\u003cul class=\"wp-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFS-05 Parallel:\u003c\/strong\u003e two independently controlled vessels from one controller. Choose it when paired runs are central to your work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFS-06 One:\u003c\/strong\u003e one vessel, three built-in pumps and a narrower controller footprint, with compatible working-volume options up to 10 L. Basic liquid-culture sensing is included in the published standard package.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFS-07 Evo:\u003c\/strong\u003e one vessel with four built-in pumps, compatible working-volume options up to 20 L and a published solid-state configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMore than one FS-06 or FS-07 can be used when separate controllers are appropriate. Tell us both the total vessel count and whether you need two vessels operated from a single controller.\u003c\/p\u003e\n\u003ch3\u003eWhen FS-06 needs the EPM expansion module\u003c\/h3\u003e\n\u003cp\u003eThe FS-06 brochure identifies selected pH-Stat and DO-Stat feeding functions, expanded oxygen\/gas control, ORP, a second external pump, and pump flow\/total-volume calculation as expansion-module-dependent. The relevant devices must also be specified. Ordinary onboard programmable control is not the same as this optional expansion.\u003c\/p\u003e\n\u003cp\u003eShare the capabilities you need; the final quote will identify the controller, module and accessory combination rather than assume every illustrated accessory is compatible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-table-wrap\"\u003e\n\u003ctable data-wp-mobile-table=\"true\"\u003e\n\u003ccaption\u003eWinpact controller comparison\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFS-05 Parallel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFS-06 One\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFS-07 Evo\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eVessels per controller\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e2\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e1\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eWorking-volume family\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e0.5–20 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e0.5–10 L\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e0.5–20 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eTouchscreen \/ built-in pumps\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e10.4 in \/ 8\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e8 in \/ 3\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e10.4 in \/ 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eController W × L × H, mm\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003e400 × 549 × 740\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003e250 × 510 × 500\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003e400 × 600 × 740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eSolid-state configuration\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003eAvailable\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003eNot supported\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth data-wp-column=\"Feature\" scope=\"row\"\u003eMass-flow \/ off-gas analysis\u003c\/th\u003e\n\u003ctd data-wp-column=\"FS-05 Parallel\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-06 One\"\u003eNot supported\u003c\/td\u003e\n\u003ctd data-wp-column=\"FS-07 Evo\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eFS-06 includes basic process sensing; some other expansions require its optional EPM module. EPM does not add a second vessel or extend it to 20 L.\u003c\/p\u003e\n\u003csection aria-labelledby=\"wp-fs06-image-heading\" class=\"wp-fs06-comparison-visual\" data-wp-addition=\"fs06-comparison\"\u003e\u003cp class=\"wp-eyebrow\"\u003eAlternative model · FS-06 One\u003c\/p\u003e\n\u003ch3 id=\"wp-fs06-image-heading\"\u003eConsidering a single-vessel Winpact bioreactor?\u003c\/h3\u003e\n\u003cp\u003eThe FS-06 One controls one vessel and has three built-in pumps. The FS-05 Parallel controls two vessels with eight built-in pumps. Use the comparison above to choose the experimental layout you need.\u003c\/p\u003e\n\u003cfigure\u003e\u003ca aria-label=\"Open full FS-06 One vessel and networking illustration\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-fs06-overview.webp?v=1792813451\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cpicture\u003e\u003csource media=\"(max-width:760px)\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-fs06-controller-detail.webp?v=1792813451\"\u003e\u003cimg alt=\"Winpact FS-06 One single-vessel bioreactor system illustration\" decoding=\"async\" height=\"1104\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/winpact-fs06-overview.webp?v=1792813451\" width=\"1792\"\u003e\u003c\/picture\u003e\u003c\/a\u003e\u003cfigcaption\u003eFS-06 One illustrated with vessel-format and networking examples. Vessel sizes and options vary by controller.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cp class=\"wp-small wp-fs06-mobile-note\"\u003eController detail shown for phone readability. Open the image to view the full vessel and networking illustration.\u003c\/p\u003e\u003c\/section\u003e\n\u003cfigure class=\"wp-media wp-size\"\u003e\u003cimg alt=\"Front-profile comparison of FS-05, FS-06 and FS-07 controller widths and heights\" height=\"750\" loading=\"lazy\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-size.webp?v=1792798230\" width=\"1000\"\u003e\n\u003cfigcaption\u003eFront profiles only; use the dimension table for controller depth and allow additional installed-system space.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv class=\"wp-actions\"\u003e\n\u003cbutton class=\"wp-button wp-button-secondary\" data-model=\"FS-06\" data-wp-open=\"\" type=\"button\"\u003eAsk about FS-06\u003c\/button\u003e\u003cbutton class=\"wp-button wp-button-secondary\" data-model=\"FS-07\" data-wp-open=\"\" type=\"button\"\u003eAsk about FS-07\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-resources-title\" class=\"wp-section wp-tint\" id=\"wp-resources\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eLook closer\u003c\/p\u003e\n\u003ch2 id=\"wp-resources-title\"\u003eWatch the system. Review the details.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-video\"\u003e\u003ciframe loading=\"lazy\" src=\"https:\/\/www.youtube.com\/embed\/SdttlanNEV0\" title=\"Winpact Parallel Fermentation System — official Major Science video\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp class=\"wp-small\"\u003eOfficial Major Science overview of the Winpact Parallel Fermentation System.\u003c\/p\u003e\n\u003cdiv class=\"wp-two-cards\"\u003e\n\u003ca class=\"wp-resource\" href=\"https:\/\/www.majorsci.com\/rwd1661\/store\/F1\/FS-05.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan class=\"wp-eyebrow\"\u003ePDF · FS-05\u003c\/span\u003e\n\u003ch3\u003eFS-05 product brochure \u003cspan aria-hidden=\"true\"\u003e↗\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eReview controller specifications and vessel choices.\u003c\/p\u003e\n\u003c\/a\u003e\u003ca class=\"wp-resource\" href=\"https:\/\/www.majorsci.com\/rwd1661\/store\/F1\/Brochure-004-Fermentor.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan class=\"wp-eyebrow\"\u003ePDF · Brochure 004\u003c\/span\u003e\n\u003ch3\u003eBioreactor \u0026amp; fermentor guide \u003cspan aria-hidden=\"true\"\u003e↗\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eCompare the wider Winpact controller family.\u003c\/p\u003e\n\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-faq-title\" class=\"wp-section\" id=\"wp-faq\"\u003e\n\u003cdiv class=\"wp-section-heading\"\u003e\n\u003cp class=\"wp-eyebrow\"\u003eBefore you configure\u003c\/p\u003e\n\u003ch2 id=\"wp-faq-title\"\u003eQuestions worth asking.\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wp-faq-grid\"\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eCan both vessels run different experiments?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Each vessel can run the same or a different experiment, using compatible sizes, types and heating arrangements. Specify both channels together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eDoes 5 L mean total vessel capacity?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. Here, 5 L means working volume. Total capacity varies: 6.7 L for a plain-bottom base-heated vessel, 6.8 L for dish-bottom examples and 7 L for an air-lifter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWhich setup suits gentle mixing?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eDiscuss air-lift vessels or pitched-blade impellers for your culture. Air-lifters use gas circulation without an agitation motor; stirred-vessel speed ranges depend on size and impeller choice.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWhat gets sterilised in the autoclave?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe selected vessels are autoclavable, not the controller. This is not an in-situ SIP system. The PT100 temperature probe is non-autoclavable; confirm the preparation procedure and chamber clearance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWill I need a separate chiller?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThat depends on your setpoint and available cooling water. Check the required coolant temperature, flow arrangement and heat load; an external circulator\/chiller is a separately configured option.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eAre all software features included?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eOnboard control, USB export and Ethernet communication are documented. Advanced EZScript is optional. Confirm remote software and external PC requirements in the quotation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eAre these PDFs operating manuals?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo: they are product brochures. Manufacturer instruction and service manuals are accessed through its Member Download Center; request the appropriate documentation for your configured system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"wp-faq-card\"\u003e\n\u003csummary\u003eWhat should I send for a useful quotation?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eShare organism or culture type, working volume for each vessel, agitation and temperature needs, gas strategy, sensing, available utilities and autoclave dimensions. Include any feed or analysis options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection aria-labelledby=\"wp-next-title\" class=\"wp-closing\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"wp-eyebrow\"\u003eYour next experiment starts with the right configuration\u003c\/p\u003e\n\u003ch2 id=\"wp-next-title\"\u003eTell us what you want to compare.\u003c\/h2\u003e\n\u003cp\u003eBlue Tiger Scientific can help frame a two-vessel specification around your culture, bench and process goals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbutton class=\"wp-button\" data-wp-open=\"\" type=\"button\"\u003eRequest configuration advice\u003c\/button\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Major Science","offers":[{"title":"2 × 0.5 L jacketed vessel kits · 220 V","offer_id":53155427320106,"sku":"BTS-FS05-2XAS5P-220","price":58512.0,"currency_code":"USD","in_stock":true},{"title":"2 × 1 L jacketed vessel kits · 220 V","offer_id":53217828864298,"sku":"BTS-FS05-2XA01P-220","price":58544.0,"currency_code":"USD","in_stock":true},{"title":"2 × 3 L jacketed vessel kits · 220 V","offer_id":53217828897066,"sku":"BTS-FS05-2XA03P-220","price":59827.0,"currency_code":"USD","in_stock":true},{"title":"2 × 5 L jacketed vessel kits · 220 V","offer_id":53217828929834,"sku":"BTS-FS05-2XA05P-220","price":65331.0,"currency_code":"USD","in_stock":true},{"title":"2 × 10 L jacketed vessel kits · 220 V","offer_id":53217828962602,"sku":"BTS-FS05-2XA10P-220","price":69543.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/bts-winpact-fs05-hero.webp?v=1792798224"}],"url":"https:\/\/bluetigerscientific.com\/collections\/major-science-bioreactors-pumps.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}