{"title":"IKA","description":"\u003cp\u003eIKA laboratory instruments from Blue Tiger Scientific.\u003c\/p\u003e","products":[{"product_id":"ika-c-mag-hs-7-digital-magnetic-hotplate-stirrer","title":"IKA C-MAG HS 7 digital Magnetic Hotplate Stirrer, 120 V","description":"\u003cdiv id=\"bts-ika-hs7\" style=\"font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;max-width:1400px;margin:0 auto;width:100%;box-sizing:border-box;\"\u003e\n\u003csection style=\"padding:24px;background:#F1F7F3;border:1px solid #B7D0BF;border-radius:10px;\"\u003e\u003cp style=\"font-size:.85rem;color:#245B45;letter-spacing:.08em;font-weight:600;\"\u003eIKA • C-MAG HS 7 DIGITAL • 0003487001 • 120 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);line-height:1.15;color:#13314E;font-weight:600;\"\u003eHeat the plate. Control the liquid. Know the difference.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:22px;align-items:center;\"\u003e\n\u003cdiv style=\"flex:1 1 280px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eBring controlled heating and magnetic mixing to routine research preparation. The IKA C-MAG HS 7 digital pairs a chemically resistant ceramic surface with an included PT 1000.60 sensor, so you can regulate temperature in the liquid rather than relying on the hotplate setting alone.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor one vessel at a time, with stirring capacity up to 10 L of water. This US configuration includes three IKAFLON stirring bars, making the instrument, sensor and starter bar selection a single clearly defined purchase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cfigure style=\"flex:1 1 280px;min-width:0;margin:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"638\" alt=\"IKA C-MAG HS 7 digital ceramic hotplate stirrer with LCD temperature display and separate temperature and speed controls\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;border-radius:8px;\"\u003e\u003cfigcaption style=\"font-size:.85rem;line-height:1.5;margin-top:8px;\"\u003eManufacturer photograph of the instrument. Included sensor and stirring bars are listed below, but are not shown.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e10 L\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eMaximum stirring volume, water\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e50–500 °C\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eHeating plate range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e100–1,500 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eStirring speed range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;border:1px solid #e0e0e0;padding:16px;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;color:#13314E;font-size:1.3rem;\"\u003e180 × 180 mm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eCeramic plate\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWhat arrives with catalog 0003487001?\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;margin:10px 0;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKA C-MAG HS 7 digital, 120 V \/ 50–60 Hz\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × PT 1000.60 stainless-steel temperature sensor\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKAFLON 20 magnetic stirring bar\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKAFLON 30 magnetic stirring bar\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003e1 × IKAFLON 40 magnetic stirring bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eVessels, a sensor-support stand and clamp, and other accessories are not listed in IKA’s standard delivery scope. Arrange secure sensor positioning appropriate to your vessel. MINISTAR and MICROSTAR overhead stirrers are separate instruments, not included parts or verified add-on accessories for this hotplate.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eChoose it for the job, not just the maximum temperature\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eRoutine heated preparation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA practical fit for research buffer and reagent preparation when your liquid, vessel and process are suitable for magnetic stirring and hotplate heating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eTemperature-sensitive workflows\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse the supplied PT 1000.60 to control the liquid temperature. IKA specifies ±0.5 K control accuracy in the medium with PT1000; actual results still depend on a suitable, well-mixed setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eLow-viscosity mixing\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe 10 L rating is based on water. Viscosity, vessel geometry and stir-bar coupling determine usable capacity. For difficult, viscous loads, evaluate a separately configured overhead stirrer instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003ePlate temperature is not sample temperature\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA hotplate transfers heat through the vessel before it reaches the liquid. Reading the plate temperature does not tell you the temperature of the whole sample. The sensor changes where the instrument measures and controls.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWITHOUT THE SENSOR\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIn mode B or C, heating without PT1000 uses the plate temperature target. The liquid may be cooler and may respond more slowly. Do not treat a plate setpoint as a verified sample temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWITH THE INCLUDED SENSOR\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003ePT 1000.60 measures in the liquid. The target is the desired medium temperature, and the actual-temperature display reports the sensor reading. Keep the sensor at least 20 mm immersed, securely held and clear of the stirring bar.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRead the numbers correctly.\u003c\/strong\u003e The medium’s actual-temperature display resolves 0.1 K. That is different from the specified ±0.5 K control accuracy. Temperature setpoint increments are 1 K. Stirring speed is adjusted with the 0–6 scale; this model does not provide a numeric RPM display.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eWill it fit your bench?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cfigure style=\"flex:1 1 240px;min-width:0;margin:0;\"\u003e\u003cdiv role=\"img\" aria-label=\"Top-view footprint diagram. Instrument body 215 mm wide and 330 mm deep; ceramic plate 180 by 180 mm. Overall height 105 mm.\" style=\"max-width:280px;margin:auto;background:#EFF3F7;border:2px solid #13314E;border-radius:8px;padding:18px;box-sizing:border-box;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:.9rem;font-weight:600;margin-bottom:12px;\"\u003eBODY WIDTH 215 mm\u003c\/div\u003e\n\u003cdiv style=\"border:2px solid #245B45;background:white;aspect-ratio:1;display:flex;align-items:center;justify-content:center;font-size:1rem;line-height:1.6;\"\u003eCERAMIC PLATE\u003cbr\u003e180 × 180 mm\u003c\/div\u003e\n\u003cdiv style=\"padding:15px 0 4px;font-size:.9rem;\"\u003eBody depth 330 mm\u003cbr\u003eOverall height 105 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigcaption style=\"font-size:.85rem;line-height:1.5;margin-top:12px;text-align:center;\"\u003eSimplified footprint guide. Not a vessel-size or clearance drawing.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAllow room beyond the 215 × 330 mm body for safe access, cables, sensor support and the vessel. The manual calls for at least 100 mm from walls and adjacent equipment and 800 mm of free space above the instrument.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe current IKA product data specifies a 180 × 180 mm ceramic plate and a 15 kg maximum load. Load and mixing volume are separate limits: neither is a guarantee that every vessel or viscous sample will work.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse a level, dry, fire-resistant, non-slip work surface and a grounded supply matching the 120 V nameplate. The instrument is rated IP21, not for immersion or washdown.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eA repeatable setup, from first mix to cool-down\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e1 • Prepare safely\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eRead the manual and assess the chemicals and vessel. With the device off and unplugged for accessory installation, secure the sensor support. Connect the PT1000 with power off. Place the stir bar in a suitable vessel and keep the probe at least 20 mm immersed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e2 • Build stable circulation\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eStart with the speed control at its left stop. Increase gradually to create stable circulation, not splashing or vessel movement. Use the supplied bar that couples reliably in your vessel; maximum supported bar length is 80 mm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e3 • Set the liquid target\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSelect the appropriate operating mode, confirm the sensor reading, then set heat. Factory mode A requires PT1000 for heating. Let the mixed sample equilibrate before recording results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003e4 • Shut down and cool\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSwitch heating off and allow the plate and vessel to cool. HOT indicates a plate above 50 °C while the unit remains powered in stirring or standby. A dark display after unplugging is not evidence that the surface is cool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eChoose the restart behavior deliberately\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe three operating modes change what happens after power is removed. Choose the mode as part of your laboratory procedure, not as a substitute for supervision.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;margin:10px 0;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMode A, the factory setting: heating requires PT1000; the temperature target resets to 0 °C and heating is off at power-on. A configurable HI TEMP value limits the adjustable target.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMode B: settings are retained after switch-off or a power interruption, with automatic restart behavior. Heating without the sensor is possible.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMode C: retains the mode B behavior and locks settings against adjustment. Return to A or B to change settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe independent safety circuit is fixed at 550 °C. It is not an adjustable solvent-specific cutoff. The family safety flyer also describes features of other IKA stirrers; do not assume every family-level feature applies to this model.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor trained laboratory use only. Do not use in explosive atmospheres. Evaluate flammable liquids and ignition risks using your lab’s risk assessment and the manual. The surface, sensor and vessel can all remain hot after heating stops.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eIf the result is not what you expected\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eThe bar loses coupling\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eReduce speed and check vessel centering, bar selection and viscosity. Increasing speed can make decoupling worse. E11 indicates a blocked motor; the manual directs a bar change or lower viscosity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eThe displayed temperature seems wrong\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eConfirm whether the display is reading the plate or PT1000. Check immersion and stable mixing. E5 concerns the sensor not being in the medium; do not treat this error as a comprehensive boil-dry guarantee.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;padding:20px;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eAn error stops the run\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSwitch off and correct the stated cause before restarting. E1 concerns a missing sensor in mode A, E3 internal overheating and E6 a defective sensor. Stop use and seek service if a fault persists.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;font-weight:600;color:#245B45;margin:0 0 18px;line-height:1.25;\"\u003eComplete the preparation workflow\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/heathrow-scientific-erlenmeyer-flasks-borosilicate-glass-graduated-narrow-neck\" style=\"color:#245B45;font-weight:600;\"\u003eHeathrow borosilicate Erlenmeyer flasks\u003c\/a\u003e offer a separate vessel-selection route. Check the selected flask’s dimensions, temperature limits and method suitability; this link is not a blanket fit or heating-compatibility claim.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/wire-lab-drying-rack\" style=\"color:#245B45;font-weight:600;\"\u003eHeathrow 90-position wire lab drying rack\u003c\/a\u003e supports the wash-and-dry stage after preparation. It is separate bench equipment, not a hotplate accessory.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:40px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:20px 0;font-family:Open Sans,sans-serif;font-weight:300;color:#333;line-height:1.15;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included with IKA C-MAG HS 7 digital 0003487001?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 120 V instrument, one PT 1000.60 stainless-steel sensor and one each of the IKAFLON 20, 30 and 40 stirring bars. Vessels and sensor-support hardware are not listed in the standard scope.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs 0003487001 the US voltage version?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes. IKA’s current US technical data identifies 0003487001 as 120 V, 50\/60 Hz, with 1020 W power input. Do not confuse it with other regional versions or assume universal voltage.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 500 °C rating mean my sample reaches 500 °C?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The current plate heating range is 50–500 °C. The liquid temperature depends on the sample, vessel and heat transfer. With the supplied PT 1000.60 immersed, the device controls to the measured medium temperature rather than substituting plate temperature for sample temperature.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes digital mean the instrument displays RPM?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Temperature is displayed digitally, but speed is adjusted using a 0–6 scale across a specified 100–1500 rpm range. Do not choose this model expecting a numeric RPM readout.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan it stir 10 L of a viscous liquid?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe 10 L maximum is specified for water. Usable capacity for more viscous liquids depends on the sample and vessel, not volume alone. A separately selected overhead-stirring system may be more suitable; IKA’s MINISTAR and MICROSTAR recommendations do not establish accessory compatibility.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat happens after a power interruption?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThat depends on the mode. In factory mode A the heat target resets to 0 °C and heating is off at power-on. Modes B and C retain settings and have automatic restart behavior. Review the manual before selecting either retained-settings mode.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow do I know when the plate is safe to touch?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eHOT appears when the plate is above 50 °C while powered in stirring or standby. Do not rely on this warning after unplugging or loss of power. Allow the plate, sensor and vessel to cool before handling.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs this a clinical device, and is supplier stock confirmed?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThis listing is for research laboratory use, not diagnostic or medical use. Supplier availability and dispatch timing must be confirmed for the destination. IKA’s public page requires login to see availability; neither a listed price nor the 5 kg instrument weight establishes stock, freight or packed shipping weight.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53395441877290,"sku":"BTS-0003487001","price":1104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-c-mag-hs7-digital.webp?v=1793390099"},{"product_id":"ika-t-25-digital-ultra-turrax-disperser-drive","title":"IKA T 25 digital ULTRA-TURRAX Disperser, 100–120 V, Drive Only","description":"\u003cdiv id=\"bts-ika-t25\" style=\"width:100%;box-sizing:border-box;max-width:1400px;margin:0 auto;font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;\"\u003e\n\u003csection style=\"padding:24px;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;color:#245B45;letter-spacing:.07em;\"\u003eIKA T 25 DIGITAL ULTRA-TURRAX • 0003725001 • US 100–120 V\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);line-height:1.15;color:#13314E;font-weight:600;\"\u003eHigh-shear preparation starts with the right drive. Results depend on the right tool.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eTurn a nonuniform liquid sample into a workable research preparation with rotor-stator dispersion. The classic IKA T 25 digital ULTRA-TURRAX gives you an LED speed readout, stepless adjustment from 3,000 to 25,000 rpm and electronic speed control for batch homogenizing, emulsifying and dispersing.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eThis listing is for the drive only.\u003c\/strong\u003e Choose a compatible dispersing tool, stand, clamp and suitable vessel separately. The guide below explains three reusable tool choices so you do not mistake a broad 1–2,000 mL water-based range for the working range of one universal shaft.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507 1200w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1200\" height=\"1200\" alt=\"IKA T 25 digital ULTRA-TURRAX classic drive with a separately sold dispersing tool shown in the manufacturer photograph\" style=\"width:100%;max-width:420px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer photograph. The fitted dispersing tool shown is not included. This order is the T 25 digital drive, not a complete stand-and-tool system.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e3,000–25,000 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eStepless speed adjustment\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e1–2,000 mL\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eH₂O range across suitable tools\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e800 W \/ 500 W\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eMotor input \/ output rating\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 160px;min-width:0;padding:16px;border:1px solid #e0e0e0;border-radius:6px;box-sizing:border-box;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.2rem;color:#13314E;\"\u003e100–120 V\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003e50\/60 Hz US configuration\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat are you buying, and what completes the setup?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eIncluded: the drive\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eOne IKA T 25 digital ULTRA-TURRAX, catalog 0003725001. The manual also lists its extension arm, hexagon socket screw, DIN 911 screwdriver and operating instructions. This is not a preconfigured stand-and-tool kit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose separately: the tool\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA compatible S 25 dispersing tool is required. Choose its water-based working range, head diameter, immersion requirements, seal and wetted materials for your method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose separately: support\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse suitable support and vessel restraint for the setup. IKA lists stands, a boss-head clamp and a strap clamp as accessories. They are not included in this drive-only order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhere the T 25 digital earns its place\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eLiquid sample homogenization\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eA fit for research preparations that need intensive local shear rather than simple bulk circulation. Tool selection and the starting sample determine the achievable result.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eEmulsions and dispersions\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse an appropriate rotor-stator element to work on liquid-liquid emulsions or solid-liquid dispersions. Confirm chemistry and process limits instead of selecting by RPM alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eEnvironmental and formulation research\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA identifies wastewater homogenization and laboratory-research dispersion among the applications. Develop a suitable method for sample volume, viscosity, heat sensitivity and the selected tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHow the tool creates high shear\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-principle-readable.webp?v=1793401789 1200w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1200\" height=\"1000\" alt=\"Simplified rotor-stator principle: sample enters axially and exits radially through the stator slots while the rotor turns inside\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal explanatory schematic based on the manufacturer’s rotor-stator description. Not an exact-tool cutaway or dimensional drawing.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe motor turns the rotor inside a stationary stator. Sample is drawn axially into the head, then forced radially through the rotor-stator arrangement. Strong shear develops in the narrow working gap.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThat is why a disperser is not interchangeable with a magnetic stirrer. A stirrer is often appropriate for dissolving or bulk mixing; a rotor-stator disperser is chosen when the preparation calls for intensive shear, dispersion or emulsification.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eIntake: sample enters along the tool axis.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eProcessing: the rotating rotor works inside the fixed stator.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eOutflow: processed liquid exits radially and recirculates in the vessel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eSpeed, head design, solids, sample volume and processing time work together. A high RPM value alone does not establish the final particle or droplet size.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhich dispersing tool do I need?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThese are three manufacturer-listed reusable S 25 N options for the classic T 25 digital. They are not included, are not interchangeable at every volume, and are not selectable purchase variants of this drive listing. Water-based ranges are starting points, not universal guarantees for every sample.\u003c\/p\u003e\n\u003cdiv style=\"border:1px solid #B7D0BF;border-radius:8px;padding:20px;margin:0 0 18px;box-sizing:border-box;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool8.webp?v=1793401507 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"600\" alt=\"S 25 N - 8 G dispersing head, catalog 0001024200, optional tool sold separately\" style=\"width:100%;max-width:480px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer close-up: S 25 N - 8 G. Optional tool, not included with the drive.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eS 25 N - 8 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCatalog 0001024200\u003c\/strong\u003e\u003cbr\u003eWorking volume: 1–50 mL H₂O\u003cbr\u003eStator diameter: 8 mm\u003cbr\u003eImmersion depth: 27–85 mm\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eSmall-volume preparations.\u003c\/strong\u003e A useful starting point when your water-like sample volume is small and the vessel allows the specified immersion. Do not substitute the larger 25 mm head just because the drive is rated up to 2 L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #B7D0BF;border-radius:8px;padding:20px;margin:0 0 18px;box-sizing:border-box;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool18.webp?v=1793401508 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"600\" alt=\"S 25 N - 18 G dispersing head, catalog 0000593400, optional tool sold separately\" style=\"width:100%;max-width:480px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer close-up: S 25 N - 18 G. Optional tool, not included with the drive.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eS 25 N - 18 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCatalog 0000593400\u003c\/strong\u003e\u003cbr\u003eWorking volume: 10–1,500 mL H₂O\u003cbr\u003eStator diameter: 18 mm\u003cbr\u003eImmersion depth: 40–165 mm\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eA broad middle range.\u003c\/strong\u003e Consider this middle-size tool when its range, immersion and vessel geometry match your method. The overlapping volume range with other heads does not make their performance identical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #B7D0BF;border-radius:8px;padding:20px;margin:0 0 18px;box-sizing:border-box;\"\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-tool25.webp?v=1793401507 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"600\" alt=\"S 25 N - 25 G dispersing head, catalog 0001713300, optional tool sold separately\" style=\"width:100%;max-width:480px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eManufacturer close-up: S 25 N - 25 G. Optional tool, not included with the drive.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eS 25 N - 25 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eCatalog 0001713300\u003c\/strong\u003e\u003cbr\u003eWorking volume: 50–2,000 mL H₂O\u003cbr\u003eStator diameter: 25 mm\u003cbr\u003eImmersion depth: 40–165 mm\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eLarger research batches.\u003c\/strong\u003e This example reaches the drive family’s 2 L water-based upper range. Check the sample depth, clearance, viscosity and required circulation rather than choosing solely by vessel capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe immersion values above are published tool specifications, not a universal startup instruction. Follow the drive and tool manuals together. For operation near a tool’s lower published immersion limit, have IKA confirm your vessel and fill geometry before use. Maintain at least 10 mm between the tool and vessel bottom, as required by the drive manual.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eAll three examples list AISI 316L stainless steel and PTFE as medium-contact materials. Their N-type construction is not rated for vacuum operation. A vacuum or pressure process requires a specifically suitable sealed tool and complete system, not just a different speed setting.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFibrous material?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eEvaluate the separately listed saw-tooth ST tools for cutting and tearing fibrous material. Do not assume the ordinary G examples shown above have the same geometry or suitability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eFine emulsions or closed systems?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFine F tools and sealed KV\/KD designs have different application limits. Review the exact element data with IKA before choosing a tool for a specific fineness, vacuum or pressure requirement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eBuild a supported, restrained setup\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-stand.webp?v=1793401508 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"1000\" alt=\"IKA R 1825 plate stand, catalog 0003160000, optional support not included\" style=\"width:100%;max-width:360px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eR 1825 plate stand, catalog 0003160000. Optional, not included. Manufacturer photograph with surrounding white space normalized.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSupport the drive and secure the vessel\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe drive’s extension arm is 13 mm in diameter and 160 mm long. IKA’s accessory selection includes the R 1825 plate stand, the R 182 boss-head clamp and the RH 3 strap clamp. Confirm the complete mounting arrangement for your vessel and tool before ordering.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThis instrument is for stand-mounted operation, not handheld use. The R 1825 stand supports the assembly; the R 182 boss-head clamp accommodates its 16 mm rod and the drive’s 13 mm arm. The RH 3 is a separate vessel-restraint accessory. The manual requires glass vessels to be secured, and at least 10 mm of clearance between the tool and vessel bottom.\u003c\/p\u003e\n\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-clamp.webp?v=1793401507 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"462\" alt=\"IKA R 182 boss-head clamp, catalog 0002657700, optional accessory\" style=\"width:100%;max-width:440px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eR 182 boss-head clamp, catalog 0002657700. Optional, not included. RH 3 strap clamp, catalog 0003008600, is a separate vessel-restraint choice.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eA practical workflow for repeatable preparation\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e1 • Match the method\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eDefine sample volume, viscosity, solids, materials compatibility and temperature sensitivity. Select the shaft and vessel as a pair, using the tool’s immersion limits rather than the drive’s overall capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e2 • Assemble with power isolated\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFollow the instrument and selected tool instructions for mounting and installation. Check that the tool is secured, the support is stable and the vessel cannot rotate or move.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e3 • Use short, controlled runs\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003ePlace the tool correctly in the liquid before operating. Start at the lowest speed and increase as needed without splashing. The three S 25 N tool manuals limit a run to one minute; seconds may be sufficient. Record tool, volume, RPM and time for repeatability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003e4 • Stop, cool and clean\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eHigh shear introduces heat. Monitor temperature-sensitive preparations and stop when the method requires. Switch off and disconnect power before disassembly or cleaning, then follow the tool-specific cleaning instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAvoid the three most common selection mistakes\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eDrive duty is not tool run time.\u003c\/strong\u003e The drive is rated for 100% ON time, but the S 25 N tools shown here are not intended for continuous operation. Their manuals specify a maximum one-minute run. Do not use the motor’s duty rating to justify a longer tool run.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDo not run the dispersing tool dry. The circulation opening must remain in the medium, with the specified immersion maintained.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDo not confuse the drive’s 5–40 °C ambient rating with a tool’s medium-temperature limit. Chemistry, seals, vessel and tool all have their own limits.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eDo not keep extending run time to chase a guaranteed fineness. Temperature rise, air entrainment and tool wear may become the limiting factors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse only within the instrument and tool manuals. This page is for research laboratory use, not clinical or diagnostic use. Do not use this drive in explosive atmospheres.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eClassic T 25 digital or an EASY CLEAN model?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThis page: classic T 25 digital\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCatalog 0003725001. LED speed display, 3,000–25,000 rpm and 800 W input \/ 500 W output. Choose a separately supplied, compatible S 25 tool. This is the established classic drive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eEASY CLEAN digital \/ control\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThese are separate instruments. Do not transfer their brushless-motor, cleaning, interface or temperature-sensing claims to this classic model. If your workflow needs those functions, request an exact-model comparison before buying.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eRelated equipment for the preparation bench\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-c-mag-hs-7-digital-magnetic-hotplate-stirrer\" style=\"color:#245B45;font-weight:600;\"\u003eIKA C-MAG HS 7 digital hotplate stirrer\u003c\/a\u003e supports heated magnetic mixing in a separate workflow. It does not replace the T 25’s high-shear action and is not offered here as a compatible disperser support.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/heathrow-scientific-glass-beakers-durable-borosilicate-lab-beakers\" style=\"color:#245B45;font-weight:600;\"\u003eHeathrow borosilicate glass beakers\u003c\/a\u003e provide vessel options to review. Check the chosen vessel’s internal dimensions, condition and method suitability; no blanket fit with every S 25 tool is implied.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:40px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:20px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat is included with T 25 digital ULTRA-TURRAX 0003725001?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThis listing supplies the classic T 25 digital drive in the US 100–120 V configuration. The dispersing tool is not included. Stands, clamps, vessel restraints and vessels must be selected separately; this is not a complete stand-and-tool kit.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhich tool lets the T 25 work with small sample volumes?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA lists the S 25 N - 8 G, catalog 0001024200, for 1–50 mL of water-based sample. Its stator diameter is 8 mm and specified immersion depth is 27–85 mm. The actual sample and vessel must allow suitable immersion and circulation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan a single shaft process the entire 1–2000 mL range?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The drive’s range covers suitable different tools. Examples are S 25 N - 8 G 0001024200 for 1–50 mL, S 25 N - 18 G 0000593400 for 10–1500 mL and S 25 N - 25 G 0001713300 for 50–2000 mL, all specified for H₂O.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan this setup run continuously because the drive is rated 100% ON time?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. Drive duty and tool run time are separate limits. The manuals for S 25 N - 8 G, -18 G and -25 G specify non-continuous operation and a maximum one-minute run. Follow the more restrictive tool and sample limits, even though the motor’s permissible ON time is 100%.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs the classic T 25 digital the same as T 25 EASY CLEAN?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. They are different IKA instruments. This page is for classic catalog 0003725001. Do not assume EASY CLEAN brushless, interface, cleaning or temperature-sensing features are included. Tool compatibility must be checked for the exact drive and element.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan the S 25 N tools shown here run under vacuum?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. IKA marks the S 25 N - 8 G, -18 G and -25 G examples as unsuitable for vacuum operation. A vacuum or pressure method requires an appropriately rated sealed tool, vessel and complete setup. The drive alone does not establish a system pressure rating.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan the tool run dry or touch the vessel bottom?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eDo not run the dispersing tool dry. Keep the circulation opening and the required length of the tool immersed, and keep the head clear of the vessel wall and bottom. Switch off before removing the tool from the liquid or changing the setup, following the manual.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eHow do I prevent heating and cross-contamination between samples?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eHigh-shear processing adds heat, so monitor temperature and develop a suitable speed and run time for the sample. Clean reusable tools according to their instructions and your laboratory procedure. Separately selected disposable tools are single-use, not a reason to promise zero contamination in every workflow.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53396356563242,"sku":"BTS-0003725001","price":3010.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-t25-drive.webp?v=1793401507"},{"product_id":"ika-s-25-n-18-g-dispersing-tool-0000593400","title":"IKA S 25 N - 18 G Dispersing Tool for T 25 | 0000593400","description":"\u003cdiv id=\"bts-ika-s25n18g\" style=\"font-family:Open Sans,sans-serif;font-weight:300;color:#26332C;max-width:1400px;margin:0 auto;width:100%;box-sizing:border-box;\"\u003e\n\u003csection style=\"padding:24px;border:1px solid #B7D0BF;border-radius:10px;background:#F1F7F3;\"\u003e\u003cp style=\"font-size:.85rem;font-weight:600;letter-spacing:.07em;color:#245B45;\"\u003eIKA S 25 N - 18 G • 0000593400 • REUSABLE DISPERSING TOOL\u003c\/p\u003e\n\u003ch2 style=\"font-size:clamp(1.7rem,4vw,2.6rem);font-weight:600;color:#13314E;line-height:1.15;\"\u003eGive your T 25 a tool matched to the sample.\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe S 25 N - 18 G adds an 18 mm rotor-stator head to a compatible IKA drive for batch dispersing, emulsifying and wet crushing. Its published 10–1,500 mL water-based working range makes it a middle-size option between the smaller 8 mm and larger 25 mm examples in the S 25 N family.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eTool only, not a complete homogenizer.\u003c\/strong\u003e Catalog 0000593400 is a reusable stainless-steel\/PTFE dispersing tool. The drive, stand, mounting hardware and sample vessel are separate. It is manufacturer-confirmed for the classic T 25 digital we sell.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-tool.webp?v=1793410870\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-tool.webp?v=1793410870\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-tool.webp?v=1793410870\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-tool.webp?v=1793410870 1000w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1000\" height=\"600\" alt=\"IKA S 25 N - 18 G dispersing tool 0000593400, manufacturer close-up of its stainless-steel head\" style=\"width:100%;max-width:600px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eExact manufacturer head close-up. This listing is the S 25 N - 18 G tool, not the motor drive or a complete stand-mounted system.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;padding:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.25rem;color:#13314E;\"\u003e10–1,500 mL\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003ePublished H₂O working range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.25rem;color:#13314E;\"\u003e18 mm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eStator diameter\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.25rem;color:#13314E;\"\u003e25,000 rpm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003eMaximum permitted speed\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 150px;min-width:0;box-sizing:border-box;padding:16px;border:1px solid #e0e0e0;border-radius:6px;\"\u003e\n\u003cstrong style=\"display:block;font-size:1.25rem;color:#13314E;\"\u003e194 mm\u003c\/strong\u003e\u003cspan style=\"font-size:.9rem;\"\u003ePublished shaft length\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhat arrives with 0000593400?\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA’s tool manual lists the following standard delivery for the ordered S 25 N tool:\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eS 25 N - 18 G dispersing tool\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eShaft key and flat key for the documented service procedure\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eMesh bag for collecting small parts during cleaning\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eHook for hanging the service card\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eTechnical information and short instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual covers several related tools. The additional 25 F-specific key and the S 25 NK bearing-remover accessory are listed only for their corresponding models, not as extra equipment supplied with this S 25 N - 18 G. A motor drive, stand, boss-head clamp and vessel are not included.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eWhy this head, rather than just any S 25 shaft?\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-head-detail.webp?v=1793410870\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-head-detail.webp?v=1793410870\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-head-detail.webp?v=1793410870\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-head-detail.webp?v=1793410870 500w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"500\" height=\"400\" alt=\"Detail crop of the S 25 N - 18 G stator slots and circulation opening\" style=\"width:100%;max-width:500px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003ePhone-readable detail crop from the same manufacturer photograph. It shows the working head, not a different tool variant.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eAn 18 mm stator around a 12.7 mm rotor\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA specifies a 0.3 mm rotor-stator gap and a maximum circumferential speed of 16.6 m\/s. These are tool-specific dimensions and limits, not settings that can be changed by selecting a different number on the drive.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe stationary stator surrounds the rotating rotor. Sample passes through the working region and is subjected to high shear. The circulation opening and bearing need liquid during operation; this is not a dry-milling attachment.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eN identifies the PTFE slide-bearing construction. The tool can be cleaned and reused, but its bearings and working edges need inspection and maintenance. G is the coarse\/general-purpose designation, not the same head geometry as a fine F or saw-tooth ST model.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eChoose the tool by volume and method\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eSmaller samples: S 25 N - 8 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCatalog 0001024200, published for 1–50 mL H₂O with an 8 mm stator. Consider it when your small sample and vessel cannot support the depth or circulation required by an 18 mm tool. Sold separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eThis listing: S 25 N - 18 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCatalog 0000593400, 10–1,500 mL H₂O, 18 mm stator. A middle-range tool for a suitable liquid batch. Check the sample chemistry, vessel opening, depth and circulation, not just nominal vessel capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eLarger batches: S 25 N - 25 G\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eCatalog 0001713300, published for 50–2,000 mL H₂O with a 25 mm stator. A separate larger-head option; do not assume it produces the same result as the 18 G at an overlapping volume.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eWater-based working ranges are manufacturer reference values, not a guarantee for every viscosity, solid content or vessel. This tool is for batch operation under ambient-pressure conditions; the N construction is not a vacuum-rated sealed shaft.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eConfirm immersion and bottom clearance together\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-clearance.webp?v=1793410870\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-clearance.webp?v=1793410870\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-clearance.webp?v=1793410870\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-clearance.webp?v=1793410870 1200w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1200\" height=\"1000\" alt=\"Conceptual vessel diagram showing the required minimum 10 mm gap beneath the tool head\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eOriginal setup concept based on the drive manual. Not a scale drawing, supplied vessel or universal vessel-fit guarantee.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe S 25 N - 18 G tool data lists an immersion range of 40–165 mm. Its 194 mm shaft length is a different dimension; do not treat the entire shaft as the usable immersion range.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe classic T 25 drive manual adds a 45 mm minimum shaft immersion and requires at least 10 mm clearance from the vessel bottom. Follow the tool and drive instructions together. If you intend to operate near the tool’s lower published limit, have IKA confirm the vessel and fill geometry before use.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA does not provide one universal minimum vessel internal diameter for this tool in the sources reviewed. An 18 mm stator diameter does not mean an 18 mm vessel is suitable. Allow the required clearance and circulation, secure glass vessels and never let the head contact the wall or bottom.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eHow rotor-stator processing differs from ordinary stirring\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe rotating rotor draws sample axially into the head, then forces it radially through the stator arrangement. Local shear acts on the preparation while liquid circulates through the vessel.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse it when your research method calls for dispersion, emulsification or wet crushing in a liquid batch. A magnetic stirrer’s bulk mixing action is different, and the two tools should not be treated as interchangeable just because both rotate.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA lists ultimate-fineness reference ranges of 10–50 µm for suspensions and 1–10 µm for emulsions. They are not guaranteed final particle or droplet sizes for every formulation. Starting material, concentration, vessel, speed and duration affect the result.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-principle.webp?v=1793410870\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-principle.webp?v=1793410870\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-principle.webp?v=1793410870\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-principle.webp?v=1793410870 1200w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1200\" height=\"1000\" alt=\"Generic rotor-stator principle with axial intake and radial outflow, not a dimensional cutaway of this tool\" style=\"width:100%;max-width:700px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eSimplified explanatory schematic. Key facts are repeated in HTML so they remain accessible on phones and to assistive technology.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eUse short runs, then inspect the result\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;\"\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003ePrepare with power isolated\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eUse only an approved compatible drive and fit the tool according to both manuals. Inspect for damage, confirm secure mounting and vessel restraint, and position the head correctly in liquid before starting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eStart at the lowest speed\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIncrease gradually as the method requires. Never exceed 25,000 rpm. Stop if the setup splashes, vibrates, makes unusual noise or releases increasing liquid from the upper side rinsing opening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eOne minute is the limit\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe tool manual specifies non-continuous operation and a maximum one-minute run; often a few seconds suffice. The T 25 motor’s 100% ON-time rating does not override this tool limit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 240px;min-width:0;border:1px solid #B7D0BF;border-radius:8px;background:#F1F7F3;padding:20px;box-sizing:border-box;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eMonitor sample temperature\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eShear adds heat. Longer processing is not automatically better and can raise sample temperature substantially. Develop speed and duration for the sample, rather than running until an assumed fineness is reached.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eReusable does not mean maintenance-free\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRinsing is not a substitute for disassembly.\u003c\/strong\u003e IKA’s manual calls for prompt separation and cleaning of the tool after working. Running it in a suitable cleaning solvent can remove much of the residue, but does not replace the documented cleaning procedure.\u003c\/p\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eSwitch off the drive, disconnect mains power and let a hot tool cool before removal.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eUse the supplied service keys and follow the manual. The stator has a left-hand thread; do not apply a generic tightening direction or force every joint the same way.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eInspect the slotted PTFE bearing and working edges. Abrasive media can round the edges more quickly, reduce dispersing effectiveness and introduce wear debris into the sample.\u003c\/li\u003e\n\u003cli style=\"font-size:1rem;line-height:1.7;padding:4px 0;\"\u003eReassemble in the documented order. Do not overtighten the rotor, which can damage the thread or teeth.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe wetted materials are AISI 316L and PTFE. IKA lists pH 2–13, solvent suitability and a maximum medium working temperature of 180 °C. Confirm the actual sample chemistry and process conditions; none of these individual limits is a blanket validation for every chemical mixture.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eCleaning and sterilization: tool, not drive\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThe manual permits sterilization of the complete S 25 N tool and describes damp heat at 121 °C and 2 bar positive pressure, suitable chemical procedures, and hot air at 160–190 °C for approximately 30 minutes. Select and validate the method for your laboratory process, remove disinfectant residues as instructed, and follow the full manual.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eThese procedures apply to the S 25 N dispersing tool, not to the T 25 motor housing. The tool is reusable equipment, not a presterile disposable. Wearing parts and damage from improper use or insufficient care are excluded by the tool manual’s warranty terms; IKA assesses manufacturer warranty claims.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003ePair it with the correct drive\u003c\/h2\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;align-items:center;gap:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\u003cfigure style=\"margin:0;min-width:0;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-drive.webp?v=1793410870\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-drive.webp?v=1793410870\u0026amp;width=400 400w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-drive.webp?v=1793410870\u0026amp;width=700 700w, https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-drive.webp?v=1793410870 1200w\" sizes=\"(max-width: 600px) 100vw, 600px\" width=\"1200\" height=\"1200\" alt=\"Classic IKA T 25 digital drive with an optional tool fitted; drive sold separately\" style=\"width:100%;max-width:380px;height:auto;object-fit:contain;display:block;margin:0 auto;border-radius:8px;\" loading=\"lazy\"\u003e\u003cfigcaption style=\"font-size:.87rem;line-height:1.5;color:#526158;margin-top:10px;\"\u003eCompatible parent equipment shown for context only. The T 25 drive, stand and vessel are not included in this tool order.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 300px;min-width:0;\"\u003e\n\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eManufacturer-confirmed: classic T 25 digital\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA’s exact S 25 N - 18 G product description and compatibility list identify the classic T 25 digital ULTRA-TURRAX, US catalog 0003725001. This tool is an accessory, not a replacement motor.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/ika-t-25-digital-ultra-turrax-disperser-drive\" style=\"font-weight:600;color:#245B45;\"\u003eShop the compatible IKA T 25 digital drive\u003c\/a\u003e. Its page explains the separately selected support hardware and broader tool choices.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eIKA also lists additional compatible T 25 variants. Match the exact drive and tool instructions before ordering; this S 25 N tool does not acquire EASY CLEAN or temperature-sensing features merely because a compatible drive offers them.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"padding:26px 0;border-bottom:1px solid #e0e0e0;\"\u003e\u003ch2 style=\"font-size:1.45rem;line-height:1.25;font-weight:600;color:#245B45;margin:0 0 18px;\"\u003eReview the vessel before you run\u003c\/h2\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003e\u003cstrong\u003eRelated workflow:\u003c\/strong\u003e \u003ca href=\"https:\/\/bluetigerscientific.com\/products\/heathrow-scientific-glass-beakers-durable-borosilicate-lab-beakers\" style=\"font-weight:600;color:#245B45;\"\u003eHeathrow borosilicate glass beakers\u003c\/a\u003e offer vessel options to assess. Check the selected beaker’s internal dimensions, usable fill depth and method suitability, and provide the glass-vessel restraint required by the drive manual. This is not a blanket compatibility claim for every beaker size.\u003c\/p\u003e\n\u003cp style=\"font-size:1rem;line-height:1.7;margin:0 0 14px;\"\u003eFor trained research laboratory use only. Not for clinical or diagnostic use. Do not use a damaged tool, run it dry, touch rotating parts or use the drive in an explosive atmosphere.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"border-top:1px solid #e0e0e0;margin-top:40px;padding-top:20px;\"\u003e\u003cdiv style=\"width:100%;padding:20px 0;font-family:Open Sans,sans-serif;font-weight:300;line-height:1.15;color:#333;\"\u003e\n\u003ch3 style=\"font-size:1.1rem;font-weight:600;margin:0 0 16px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWill 0000593400 fit the classic IKA T 25 digital?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eYes. IKA names T 25 digital as suitable in the exact S 25 N - 18 G product description, and lists US drive 0003725001 in its compatibility section. The tool is sold separately from the motor drive, stand and vessel.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhat sample volume is the S 25 N - 18 G designed for?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eIKA specifies 10–1500 mL H₂O for catalog 0000593400. This is a water-based working range, not a guarantee for every viscous or solid-containing preparation. Vessel opening, depth, circulation and sample properties also matter.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eIs an 18 mm stator the same as a minimum 18 mm vessel diameter?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The 18 mm value is the stator’s outside diameter, not a manufacturer-approved minimum vessel ID. Provide the opening, circulation and wall\/bottom clearance required by both manuals, and restrain the vessel appropriately.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eWhy does the tool list 40 mm immersion while the drive manual says 45 mm?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThese are different published instructions that must be considered together. The tool data states 40–165 mm immersion, while the classic T 25 drive manual specifies at least 45 mm shaft immersion and a 10 mm bottom gap. Have IKA confirm geometry when planning use near the lower limits; do not use the tool table alone as a startup instruction.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I run this tool continuously on a T 25 motor?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. The tool manual specifies non-continuous use, normally seconds, with a maximum one-minute run. A drive rated for 100% ON time does not remove the tool’s limit. Processing also heats the sample.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eDoes the 180 °C rating apply to the motor or all chemicals?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. It is the published maximum working-medium temperature for this tool. The classic T 25 drive has a separate 5–40 °C ambient rating. Check the wetted PTFE\/AISI316L, pH range and actual chemical compatibility before using a method.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan this S 25 N tool work under vacuum?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eThe standard N tools shown in IKA’s selection literature are for open-batch, ambient-pressure use, not vacuum operation. Choose a specifically suitable sealed tool and complete setup for a vacuum or pressure method; do not infer a system rating from the drive alone.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #e0e0e0;border-radius:8px;margin:0 0 10px;background:#fff;\"\u003e\u003csummary style=\"cursor:pointer;padding:14px 16px;font-size:1rem;font-weight:600;list-style-position:inside;\"\u003eCan I just rinse it between samples or put the entire drive in an autoclave?\u003c\/summary\u003e\u003cdiv style=\"padding:0 16px 14px;\"\u003e\u003cp style=\"font-size:.97rem;line-height:1.6;margin:0;\"\u003eNo. IKA calls for prompt tool disassembly and cleaning; a solvent rinse does not replace that procedure. The manual’s sterilization methods concern the S 25 N tool, not the T 25 motor housing. Use a validated cleaning method suitable for your samples and laboratory procedure.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IKA","offers":[{"title":"Default Title","offer_id":53396804043050,"sku":"BTS-0000593400","price":2100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/1579\/4474\/files\/ika-s25n18g-tool.webp?v=1793410870"}],"url":"https:\/\/bluetigerscientific.com\/collections\/ika.oembed","provider":"Blue Tiger Scientific","version":"1.0","type":"link"}